| 1 | P& F M.S.Black pipe heavy confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of following Dia 80 mm, 4.85 mm Thick |
| 2 | P& F M.S.Black pipe heavy confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of following Dia 125 mm,8 mm Thick |
| 3 | P& F M.S.Black pipe heavy confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of following Dia 150 mm,4.85 mm Thick |
| 4 | Providing and fixing/Replacementof M.S Black pipe(9.5 mm thickness) confirming to IS 3589with required nut bolts & packing sheets etc complete as required of following Dia 250 mm ,9.5 mm thick |
| 5 | Providing and fixing/Replacementof M.S Black pipe(9.5 mm thickness) confirming to IS 3589with required nut bolts & packing sheets etc complete as required of following Dia 200 mm ,9.5 mm thick |
| 6 | Providing and fixing/Replacementof M.S Black pipe(9.5 mm thickness) confirming to IS 3589with required nut bolts & packing sheets etc complete as required of following Dia 300 mm ,9.5 mm thick |
| 7 | Replacement of Swing type Non return Valve of CI body with Door ,bronze to ubber rings confirming to IS 5312 (part 1&2) ,PN1.6 complete as required NRV 80 MM |
| 8 | Replacement of Swing type Non return Valve of CI body with Door ,bronze to ubber rings confirming to IS 5312 (part 1&2) ,PN1.6 complete as required NRV 150MM |
| 9 | P& Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia 80 mm (10 mm thickness) |
| 10 | P& Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia 125 mm (20 mm thickness) Rating PN 16 |
| 11 | P& Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia 150 mm(10 mm thickness) |
| 12 | P& Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia 200 mm (20 mm thickness) |
| 13 | Providing and fixing of MS Flange with required nutbolts & packing sheets etc. complete as required of following dia 250 mm (20 mm thickness) |
| 14 | P& Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia 300 mm (25 mm thickness) |
| 15 | P&F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia. 80 mmshort bend c-class |
| 16 | P&F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia. 125 mmshort bend c-class |
| 17 | P&F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia. 150 mmshort bend c-class |
| 18 | Providing and fixing of MS Bend with required nutbolts & packing sheets etc. complete as required of following dia 250 mm (8 mm thick ) length 0.5 m |
| 19 | P& Fof M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia 300 mm, 8 mm thick, length 0.75 m |
| 20 | P &F of Ball Valve with Flange Confirming to IS-9890, rating PN 16 (Three piece design) of following size Ball valve 80 mm , class 125 |
| 21 | Supplying, fixing, testing and commissioning of non rising spindle sluice valve of CI Body with wedge bronze ring confirming to IS 14846 and SS, ISI 6603 marked complete PN 1.6 Complete as required. (80 MM) |
| 22 | Providing and fixingof Cast Iron Non risingsluice valve of 125MM Flanged end as per ISBody coverIS -14846 , body dome - wedge-CI IS 210 ,GR FG260 Body & Wedge Rings -Bronze IS 318 GR :LTB2 Spindle -SS IS 6603 Gr 12Cr 12 gland Packing -Greasy Jute Packing fasteners - CS IS 1367 , CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 16) |
| 23 | Supplying, fixing, testing and commissioning of non rising spindle sluice valve of CI Body with wedge bronze ring confirming to IS 14846 and SS, ISI 6603 marked complete PN 1.6 Complete as required. (150 MM) |
| 24 | Supply installation testing and commissioning of Fully Automatic Star Delta Starter in existing panel with SPP and overload relay feature i/c connections etc. complete as required 25 hp 3-phase 415V 50 Hz motor. |
| 25 | Supply installation testing and commissioning of Fully Automatic Star Delta Starter in existing panel with SPP and overload relay feature i/c connections etc. complete as required 40 hp 3-phase 415V 50 Hz motor. |
| 26 | SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having minimum Discharge of 40 m3/hr at Head- 15 Mtrs, RPM - 1450 RPM (syn) having suction and delivery size 80 mm dia. mounted on a common base frame coupled with Min. 5 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Casing- C.I., Impeller- C.I., Shaft- 40C8 complete with coupling, coupling guard and foundation bolts. |
| 27 | SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having minimum Discharge of 350 m3/hr at Head- 15 Mtrs, RPM - 1450 RPM (syn) having suction and delivery size 150 mm dia. mounted on a common base frame coupled with Min. 40 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. asPacking: Gland Casing- C.I., Impeller- C.I., Shaft- 40C8 complete with tyrecoupling, coupling guard and foundation bolts. |
| 28 | P&F of Onload changeover switch four pole in existing cubicle panel with advance neutral conforming to IS:13947 (Part-3) including drilling holes in cubicle panel, making connections, etc. complete as required of 250 A |
| 29 | P&F of 4 pole Switch Disconnector in existing Cubical Panel conforming to IEC:60947-3 complete as required of 250 A |
| 30 | Providing and fixing of four pole MCCB havinng rating capacity of 63 Amp and breaking capacity of 10 KA (Icu) with thermomagnetic release and terminal spreader in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 31 | SITC of power distribution board made out of 1.6 mm steel sheet, epoxy powder coated , specially designed AL bus bar for 400A to 630A with heat shrinkable colour coded sleeves suitable for accomodating MCCB\"S MCB\"S/Isolators as incoming and outgoing as required (without MCCB\"s/MCB\"s/Isolators) complete with digital meter Module, including voltmeter, Ammeter with selector switch,CT, control fuse and indicating lights including connections as required (confirms to IS:8623) |
| 32 | Supplyof XLPE insulatedPVC sheathed Aluminium conductor armouredcable1.1 KV conformingto IS 7098/ (Part-I) ofsize 3.5 core 240 sqmm |
| 33 | Supplyof XLPE insulatedPVC sheathed Aluminium conductor armouredcable1.1 KV conformingto IS 7098/ (Part-I) ofsize 4 core 50 sqmm |
| 34 | Supplyof XLPE insulatedPVC sheathed Aluminium conductor armouredcable1.1 KV conformingto IS 7098/ (Part-I) ofsize 4 core 16 sqmm |
| 35 | Supplyof XLPE insulatedPVC sheathed Aluminium conductor armouredcable1.1 KV conformingto IS 7098/ (Part-I) ofsize 4 core 10 sqmm |
| 36 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 37 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 38 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas required. Above 185 Sq mm and Up to 400 sq.mm |
| 39 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas required.Above 35 sq. mm and upto 95 sq. mm |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open ductas required.Up to 35 sq.mm |
| 41 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 3½ X 240 sq. mm (62mm) |
| 42 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 4 X 16 sq. mm (28mm) |
| 43 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 4X50 sq. mm(35 mm) |
| 44 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 4 X 10 sq. mm (25 mm) |
| 45 | Providing and fixing following rating and breaking capacityand pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 50kA, FPMCCB |
| 46 | Providing and fixing following rating and breaking capacity MCCB with adjustable thermal & adjustable magnetic setting with rotary handle in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 A, 36kA, FPMCCB |
| 47 | Providing and fixing following rating and breaking capacity MCCB with adjustable thermal & adjustable magnetic setting with rotary handle in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A, 36kA, FPMCCB |
| 48 | Providing and fixing following rating and breaking capacity MCCB with adjustable thermal & adjustable magnetic setting with rotary handle in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 kA,TPMCCB |
| 49 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 50 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 51 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 52 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 53 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 54 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |