Repairing And Replacement Of Some Miscellaneous Items And Other Electrical Works At Cmo Building, Kmc.p-1 SUPPLY PHILIPS LEDTUBE, MODEL NO: MAS LEDTUBE 1200MM 18W865 T81-2100LM [I&W WAYS SCHEDULE 2022, P-113, I-5.3 F.23] 2 SUPPLYING OF APPROVED MAKE PEDESTAL FAN OSCILLATING TYPE WITH BASE, BLADES, GUARD, SPEED REGULATOR ETC. AC 230-250 VOLTS.500MM SWEEP. [I& WAYS SCEDULE 2022, P-115,1-5.3 6.2.1] 3 GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OF WINDOW/ SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC. IF ANY.1.5 TR [I&W WAYS SCHEDULE 2022, P-117, I-5.3 H.5.2] 4 ERECFION AND INSTALLATION OF BODR COOLING AND CONDENSING UNIT FOR 1.5 TON SAC AT RESPECTIVE LOCATION ON WALL ALONG WITH TERMINATION OF REFRIGERANT LINE AS PER DIRECTION OF EIC MENDING GOOD D*RNAGE TO ORIGINAL FMISH. 5 SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF SUCTION/DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0/1.5 TR/2 TR/3 TR CAPACITY INCLUDING BRAZING, NITRILE RUBBER INSULATION 6/9MM THICK CLASS O, ETC COMPLETE AS REQUIRED.COPPER TUBE 3/8 [I&W WAYS SCHEDULE 2022, P-117,1-5.3 H.4.2] 6 SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF SUCTION/DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0/1.5 TR/2 TR/3 TR CAPACITY INCLUDING BRAZING, NITRILE RUBBER INSULATION 6/9MM THICK CLASS O, ETC COMPLETE AS REQUIRED.COPPER TUBE 5/8 [I&W WAYS SCHEDULE 2022, P-117,1-5.3 H.4.2] 7 OPENING THE CEILING FAN TESTING, CHECKING AND RE-WINDING BY SUPPLYING SUPER ENAMELLED COPPER WIRE OF APPROPRIATE GAUGE, MINILEX PAPER, MICA SHEET, CHANGING THE LOOPS, OVERHAULING, BACKING, VARNISHING, RE-FITTING AND USING AND MEASURING R.P.M. FOR CEILING FAN ABOVE 36 SWEEP UP TO 60 SWEEP. [I&W WAYS SCHEDULE 2022, P-116, 1-5.3 G.9] 8 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire brand (approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy, fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 9 GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OF WINDOW/ SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC.1.5 TR [I&W WAYS SCHEDULE 2022, P-117,1-5.3 H.5.2] 10 GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OF WINDOW/ SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC.2.0 TR [I&W WAYS SCHEDULE 2022,P-117,1-5.3 H.5.3] 11 Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. 12 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A FP 13 Schedule of Rates FOR Wiring in PVC Insulated and Sheathed Wire in El Conduits/ Gl Conduits By single core stranded Copper conductor Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in El conduit/Gl conduit and painting 3x6 sqmm wire in 19 mm conduit incl. S&F 2x10 SWG GI ECC El Conduit 14 BUILDING WORKS (C) Brickworks, Concrete Works etc A. BRICK WORKS 7. Brick work with 1st class bricks in cement mortar (1:4) (b) In superstructure, ground floor. (3rd Corrigenda & addenda dated 04.06.2018) 15 BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. A. ORIGINAL WORKS 1. M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg./m. or 15% of weight for finished structal members weighing less than 22.5 Kg./m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m./2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m (3rd Corrigenda & addenda dated 04.06.2018) 16 Supply and delivery of MCCBs with thermal magnetic release breaking capacity Thermal release rang 200-250A, Breaking capacity Icu at 415V AC, 50Hz, 50KA, 4 pole 17 Supply & delivery of the following 50 Hz, AC, Direct on Line Starter of continuous duty in sheet steel enclosure (make L&T/ABB/SCHNEIDER):7.5 HP Three Phase (Max. Relay range 20-32 Amp)