| 1 | Supply Installation & Testing Commissioning of 5 H.P Borewell Submersible Pump set in exisiting borewell used on three Phase suitable for discharge of Flow Range-40-190 LPMat a total head of 120-32mtrs. Working on 415 volts A.C. supply etc. complete as reqd. |
| 2 | Supply Installation & Testing Commissioning of 5 H.P Horizontal Open Well submersible pump set used on 3 Phase AC Supply capable to deliver 400-180 LPM at a head of 36-48 Mts. in the existing Sump/open well i/c connection , lowering as required. |
| 3 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 4 | 40 mm |
| 5 | Lifting & Lowering Submersible Pump Set along with G.I. pipe upto 5 HP damage and defective pump set from existing UG sump with the help of chain and pulley block i/c cartage from site to workshop as reqd. |
| 6 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 7 | 40 mm Dia |
| 8 | 50 mm Dia |
| 9 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 10 | 40 mm Dia |
| 11 | 50 mm Dia |
| 12 | Supplying and fixing 3 x 4 sq.mm sizes flat copper conductor submersible PVC insulated PVC sheathed 1.1 KV grade cable i/c connection & testing etc. complete as reqd. (ISI marked). |
| 13 | Supplying and Fixing of PVC coated steel wire rope 8 mm dia complete with shackles for fixing of pump set during and after lowering of pump set to avoid slippage complete as reqd |
| 14 | Fabrication, Installation, Testing and Commissioning of floor mounting double door minimum 300 mm depth with locking arrangement front and rear openable, totally enclosed,compartmentalized,dust, vermin proof and outdoor type Feeder Pillar (IP54) fabricated out of 2mm thick cold rolled carbon annealed sheet steel, (minimum) surface area 0.50 Sq.Mtr, suitable size bus bar, powder coated paint of approved shade after 7 tank cleaning process and 1 no 20x3mm GI strips throughout the width of feeder pillar consisting two earth studs on each strip complete with provision for incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing angle iron frame made of (40mm X 40mm X 5 mm thick ) angle iron, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 etc complete as reqd. |
| 15 | (Drawing shall be got approved from Engineer-incharge before fabrication) |
| 16 | (For 5 HP Submersible Pump) |
| 17 | a) 32 Amp TP MCCB with rotary handle -1 No |
| 18 | b) single phase preventor-1 no |
| 19 | c) 18 Amp ,TP AC3 duty contractor-1 no. |
| 20 | d) O/L relay 9-15-1 no. |
| 21 | e) Aux contact block 2 NO+2NC-1 No |
| 22 | f) 2 A ,SP,MCB-1 No |
| 23 | g) Indicating lamp (R-Y-B) with fuse - 1set |
| 24 | h) Start/stop push buttom-1 set |
| 25 | i)voltmeter(0-500), ammeter (0-30amp)- 1 set |
| 26 | j) ON/OFF Indication LED Type-1set |
| 27 | k) Danger Notice plate : 1 No. |
| 28 | Fabrication, Installation, Testing and Commissioning of floor mounting double door minimum 300mm depth with locking arrangement front and rear openable, totally enclosed,compartmentalized,dust, vermin proof and outdoor type Feeder Pillar (IP54) fabricated out of 2mm thick cold rolled carbon annealed sheet steel, (minimum) surface area 1.50 Sq.Mtr, 200 A TPN Al. bus bar, powder coated paint of approved shade after 7 tank cleaning process and 1 no 20x3mm GI strips throughout the width of feeder pillar consisting two earth studs on each strip complete with provision for incoming and outgoing switchgears including making connections/ inter connections with lugs/ thimble for switchgears and control wiring with 2.5 sq.mm PVC insulated FRLS copper conductor cable, including providing angle iron frame made of (40mm X 40mm X 5 mm thick ) angle iron, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 etc complete as reqd. |
| 29 | (Drawing shall be got approved from Engineer-incharge before fabrication) |
| 30 | (For 4 Nos. 5 HP Open well Submersible Pump) |
| 31 | Incomer: |
| 32 | a) 150 Amp 16KA TP MCCB- 1 No. |
| 33 | Digital Ammerter (0-250A) with selector switch- 1 No. |
| 34 | Digital Volt merter (0-500A) with selector switch- 1 No. |
| 35 | Indication LED Lamp RYB- 3 Nos. |
| 36 | 150/5A CT Class 1- 3 Nos. |
| 37 | 6A SP MCB- 3 Nos. |
| 38 | Out goining: |
| 39 | a) 32 Amp TP MCCB - 4 Nos. |
| 40 | b) Single phase preventor- 4 Nos. |
| 41 | c) 18 Amp ,TP contractor 220 V- 4 Nos. |
| 42 | d) O/L relay 9-15-4 Nos. |
| 43 | e) Add on Block 2 NO+2NC- 4 Nos. |
| 44 | f) 6A ,SP,MCB-12 Nos |
| 45 | g) Indicating lamp (R-Y-B) with fuse - 12 Nos. |
| 46 | h) Start/stop push buttom- 8 Nos. |
| 47 | i) Auto Manual Selector Switch- 4 Nos. |
| 48 | Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV gradein the existing RCC/ HUME / METAL pipe as required |
| 49 | a) 4 x 25 sq.mm |
| 50 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 51 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 52 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 53 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 54 | 4 X 25 sq. mm (28mm) |