Tender For Re-Insulation In Class- F And Rewinding Of Stators Of6.6 Kv Ht Motors Of 5X200 M.W, Units, Btps, Obra - Complete Rewinding Of 6.6 Kv B.F.P. Motor Stator (3500Kw, 54 Coils)With Fresh Copperand Class F Insulation & Replacement Of All Rtds 2 C, obra-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited has published Tender For Re-Insulation In Class- F And Rewinding Of Stators Of6.6 Kv Ht Motors Of 5X200 M.W, Units, Btps, Obra - Complete Rewinding Of 6.6 Kv B.F.P. Motor Stator (3500Kw, 54 Coils)With Fresh Copperand Class F Insulation & Replacement Of All Rtds 2 C. Submission Date for this Tender is 13-01-2025. Overhead Line Tenders in obra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

47022984
Tender For Re-Insulation In Class- F And Rewinding Of Stators Of6.6 Kv Ht Motors Of 5X200 M.W, Units, Btps, Obra - Complete Rewinding Of 6.6 Kv B.F.P. Motor Stator (3500Kw, 54 Coils)With Fresh Copperand Class F Insulation & Replacement Of All Rtds 2 C
Open Tender
Indian
Uttar Pradesh
Obra
13-01-2025

Tender Details

Tender For Re-Insulation In Class- F And Rewinding Of Stators Of6.6 Kv Ht Motors Of 5X200 M.W, Units, Btps, Obra - Complete rewinding of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with fresh copperand class F insulation & replacement of all RTDs 2 Complete reinsulation of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 3 Stator core re-staggering 4 Rate of new coil with fresh copper and class-F insulation for one coil only 5 Complete rewinding of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with fresh copperand class F insulation & replacement of all RTDs 6 Complete reinsulationof 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 7 Stator core re-staggering 8 Rate of new coil with fresh copper and class-F insulation for one coil only 9 Complete rewinding of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with fresh copperand class F insulation & replacement of all RTD 10 Complete reinsulation of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 11 Stator core re-staggering 12 Rate of new coil with fresh copper and class-F insulation for one coil only 13 Complete rewinding of 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with fresh copperand class F insulation & replacement of all RTDs 14 Complete reinsulationof 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs 15 Stator core re-staggering 16 Rate of new coil with fresh copper and class-F insulation for one coil only 17 Complete rewinding of 6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils)with fresh copperand class F insulation & replacement of all RTDs 18 Complete reinsulation6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs 19 Stator core re-staggering 20 Rate of new coil with fresh copper and class-F insulation for one coil only 21 Complete rewinding of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils) with fresh copperand class F insulation & replacement of all RTD 22 Complete reinsulation of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 23 Stator core re-staggering 24 Rate of new coil with fresh copper and class-F insulation for one coil only 25 Complete rewinding of 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with fresh copperand class F insulation & replacement of all RTDs 26 Complete reinsulation 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 27 Stator core re-staggering 28 Rate of new coil with fresh copper and class-F insulation for one coil only 29 Complete rewinding of 6.6 KV C.E.P.Motor Stator (220KW, 48 Coils) with fresh copperand class F insulation & replacement of all RTDs 30 Complete reinsulation of 6.6 KV C.E.P.Motor Stator (220KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs 31 Stator core re-staggering 32 Rate of new coil with fresh copper and class-F insulation for one coil only 33 Complete rewinding of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with fresh copperand class F insulation & replacement of all RTDs 34 Complete reinsulation of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs 35 Stator core re-staggering 36 Rate of new coil with fresh copper and class-F insulation for one coil only 37 Complete rewinding of 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils)with fresh copperand class F insulation & replacement of all RTDs 38 Complete reinsulationof 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs 39 Stator core re-staggering 40 Rate of new coil with fresh copper and class-F insulation for one coil only

Key Value

Document Fees
INR 1180 /-
EMD
INR 40000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail