Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL Works |
| 2 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 3 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 4 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball bearing hinges is excluded). |
| 5 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately). |
| 6 | 12 mm cement plaster of mix : |
| 7 | 1:4 (1 cement: 4 fine sand) |
| 8 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as permanufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 9 | On concrete work/ plastered work |
| 10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | Providing and fixing UPVC windows with 3 tracks having stainless steel moveable jali shutter, fixed and openable sliding shutters having Single Glass Unit consisting of 6 mm thk EVO toughened glass. The moveable shutters shall be lockable with key and shall have handles for easy operation of sliding, the sliding shutters shall be mounted on tracks with metal strip on which the rollers shall roll at bottom of the openable windows. All sections of the frame and sash shall be reinforced in accordance with the system supplier’s recommendations using galvanized mild steel in a single continuous length. The profile material must be pristine white high impact modified window grade UPVC and must be colorfast and conform to EN12608:2003 code. The profile shall be a hollow 3-chamber (across depth) profile with a outer wall thickness of minimum 2.4mm only. The outer profile shall have a front to back depth of minimum 80mm platform. The profile shall be uniform and free from foreign bodies, cracks or marks. The window units shall be designed with all corner joints, transom joints and mullion joints being mitered and fusion welded. All excess material is to be neatly trimmed and neatly feature grooved/raised nib finish at corners, transom joints and mullion joints. The finished product shall be free all sharp edges, burrs and the like that may be hazardous to the user. Reinforcement shall be made from galvanised steel of minimum1.5 mm thickness as per strength requirement.All beads will be cut at the correct degree recommended by the manufacturer. Glass retention clips must be fitted in accordance with the System supplier’s recommendations.The weather seals are to be fitted in continuous lengths and grooves. The joints in the vent weather seal are to be positioned at the bottom and in the outer frames at the top. All work shall be carried out as per drawing & direction of Engineers- in-charge.the rates quoted shall include the cost fixing with fasteners, filling the gaps with silicon sealant of 795 grade, all the above mentioned works, any scaffolding, frame work, civil work required will be provided by civil contractor.& any other items if required for sealing, structural stability & commissioning of the building making it air/water tight complete in all respects.Note : For uPVC frame and sash extruded profiles minus 10% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 12 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 13 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 14 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 15 | In cement mortar |
| 16 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading at NIPER campus dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 17 | Providing and fixing SS Ball Bearing Hinges of 100 X 75x3 mm inluding cutting into position fixing etc complete with stainless steel screws (All Hardware shall be ofSS304 Grade of Dorma/ Dline /yale /hettich / Stanley/ Blum make and should begot approved from Architect / Engineer In- charge before installation) |
| 18 | Providing and fixing SS tower bolt of 300 mm height inluding cutting into position fixing etc complete with stainless steel screws (All Hardware shall be of SS 304 Grade of Dorma/ Dline /yale /hettich / Stanley/ Blum make and should be got approved from Architect / Engineer In-charge before installation) |
| 19 | Providing and fixingtubular handle MS barpowder coated 50 micron outer dia 16mm,long with SS screws etc complete as per direction of Engineer-in-Charge. |
| 20 | Providing and applying pencil epoxy coving at joints of walls and chowkhats with convavity on the exposed surface as per satisfaction of the Engineer-in-Charge. |
| 21 | Providing and applying homogenous vinyl coving at the joints of walls and floors & joints of ceiling and wall of radius 75mm with concavity on the exposed surface as per the pattern shown in the drgs/ requirements as per satisfaction of the Engineer-in-Charge of min 2.00 mm thick anti static, anti microbial (bactreia/fngus), no wax, no polish, phthalate free, low VOC type suitbale for use in hospitals/ labs etc of armstrong/ gerfloor/progressive/ LGincluding cost of adhesive of approved quality, making of cove at the corner, pvc welding of all joints and as per approved colour by Engineer-in-Charge.epoxy . |
| 22 | Providing & fixing of homogenous vinyl flooring 2.00 mm thick anti static, anti microbial (bactreia/fngus), no wax, no polish, phthalate free, low VOC type suitbale for use in hospitals/ labs etc of armstrong/ gerfloor/progressive/ LGincluding cost of adhesive of approved quality , pvc welding of all joints and as per approved colour by Engineer-in-Charge. |
| 23 | Electrical |
| 24 | In lab work tables - Providing, fixing and commissioning of computer network and UPS wiring on/neartable/wall using LEGRAND/ AMP/ TYCO / SYSTIMAX(Blue colour for data ) make UTP cat-6 cable from with each RJ45 jack terminatedby a single cat-6 cable and provision of UPS power supply using 3x4sqmm multistrand FRLS copper wire of finolex/RR kabels/Lapp/Havells cables make from UPS Distribution board to table, a maximum of 4 nos points can be looped together for power supply. Each lab table to have 1 RJ 45 jacks with two nos 6A socket, 1 nos. 16A socket & 1 nos 6A switch & 1 nos 16A switch. UPS power supply sockets and one switch.All these mentioned points shall be provided using legrand arteor/ schneider Zencelo/ Panasonic vision of modular range of products. The rates quoted for each point shall be complete in all respects including metal boxes,face plates, conduiting, tagging, chiselling, concealing of conduits (above false ceiling, within partitions etc.), cutting of existing flooring etc., termination of computer wiring as per requirements of computer administrator duly certified from a computer network certification company, termination of electrical wiringin UPS distribution board, termination of telephone wiring etc. complete in all respects.(1 nos consists of 2x6A socket, 1x16A socket, 1 x6a switch, 1 x16a switch, 1 RJ 45 data points along with wiring for electrical supply & data with seperate PVC conduiting for data & electrical supply. no measurement of wiring shall be done). |
| 25 | Wiring for light point/fan point / exhaust fan point/ call point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRSL PVC insulated coper conductor single core etc. as required. |
| 26 | Group C |
| 27 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required from Distribution board to the first switchboard. |
| 28 | 2X1.5 sqmm. + 1X1.5 sqmm earth wire |
| 29 | 2X2.5 sqmm. + 1X2.5 sqmm earth wire |
| 30 | 2X4 sqmm. + 1X4 sqmm earth wire |
| 31 | 2.5 sqmm FRLS PVC single core wire |
| 32 | Supplying and fixing following Double door MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly wired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).Hager/ Legrand/ Panasonic /Schenider. |
| 33 | Single phase12 way (2 + 12),Double Door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Hager, Legrand, Panasonic & Schenider.) |
| 35 | Single Pole |
| 36 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Hager, Legrand, Panasonic & Schenider.) |
| 37 | 63 A |
| 38 | Providing, fixing and installing ofLinear 1200 Fixture20 W+/- 1W Suspended mounted having Extruded Aluminium black housing with HET diffuser with minimum system lumen efficacy of 110 lm/W and width<60mm, P.F.>0.95 with THD<10% ,CCT 5700 K/4000K, CRI 80.the fxtures shall be joined edge to to give a seamless lok with one single diffuser for the full set of fixtures including the end caps & hanging machanism from OEM. The Input voltage range shall be 150V to 270V .The LEDs used in the luminaire shall have CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The LED with Useful life of 50000 Hrs at L70.Fixture have Surge Protection 2.5kV-4kV . Wipro LM34-251-XXX-40/57BG2L/LT Cane G5 LINEAR PENDENTS/Trilux LC52 H1 600 OTA 52 LED 2100-840 ET 01/ Philips SP780X H LED22S-6500 PSU W5L112 OD XX.The rate quoted is for inclusive of looping wiring of 2x1.5 sqmm |
| 39 | Providing, fixing and installing of 18-20W surface Batten LED lighter, 6500K colour temperature, maximum system wattage of 20Wahving minimm 2000 lumens, useful life of 50000 Hrs (Complete LM 80 test report for LED should be submitted) , isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less that 10% should be integral to the luminaire complete with all accessories required with lamps.Panasonic Cat no -PBTM08208/ Wipro Cat. No LL20-221-XXX-65ALNE /Tisva RAY SQ PRO LED BATTEN FL1862T5R 18W 65K/ Philips : BN170C LED20S-6500 L120 PSU WH/ Trilux:TRL-X F OTA 4000-857 ET. The rate quoted is for inclusive of looping wiring of 2x1.5 sqmm |
| 40 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) , class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Havells/ Bajaj / Crompton greaves/Usha/Panasonic. |
| 41 | Supply, installation, testing and commissioning of followingsizes of cu/ GIstrip/wireclampedto walls,cable trays,busducts, cables, in recess (including cost of digging & backfilling) or on surfaceetc for equipment/ System / Lightning protectionearthing completeas required including interconnectionbetween lengthatjoints, allfixing accessoriessaddles, clamps, test joints etc.andother fixing hardware material as required for proper installation. |
| 42 | 25 x 5 mm strip of Copper |
| 43 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 44 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 45 | S/I/T/C ofAC, Gas tubing, accessories and allied Lab works to set upcellCulturelabas per BSL2 in Block I (FF) at NIPER, SAS Nagar |
| 46 | Supply/installation/testing/commissioning ofsplit Airconditioner capacity 2 TR(cooling and heating )with indoor , outdoor unit,interconnectingcopper tubing ,insulation , interconnecting wiring ,etc in completeas per siterequirement to providerated cooling as perspecifications laid : conforming to IS: 1391 ( Part 2) Latest |
| 47 | i) Standard CoolingCapacityat 100 % Load: 6300Watts Min |
| 48 | ii)Standard heating Capacity at 100 % Load : 6400 Watts Min |
| 49 | iii)Design of the Indoor and outdoor unit shall be ofsingle OEM |
| 50 | iv) Rated Voltage :single Phase 230V ± 10 %,50 Hz |
| 51 | v) Technology of airconditioner: Inverter Technology /twin rotary . DesignAmbient temp 48°C minimum . |
| 52 | vi) Rated power consumption (Range) : as per OEM Design |
| 53 | vii) Function: Cooling ,Dehumidification and Heating |
| 54 | viii) body shade –white/off whitescratchless (as per OEM ) |
| 55 | ix) BEE star rating : 3 star or higher efficiency rating (as per specifications of BEE effective from 1st July2022) |
| 56 | Indoor unit ( Wall Mounted) : |
| 57 | i) Air flow : length of air flow > 15 ft |
| 58 | ii) Cooling Coil Row : 2/3 nos, 100%copper |
| 59 | iii) Sound Level : below 45 dB |
| 60 | iv) Filter : anti bacterial |
| 61 | v) Louver Swing : 3D |
| 62 | vi)fan motor options: Auto /low/medium/High |
| 63 | vii) Remote control (as per OEM standard ) |
| 64 | viii) body shade –white/off whitescratchless (as per OEM) |
| 65 | Outdoor Unit: |
| 66 | i) Compressor type : DC/ AC Inverter-return cooled /Twin Rotary or equivalent as per OEMdesigned) |
| 67 | ii) Expansion Valve : motorized electronic. |
| 68 | iii) Refrigerant piping thickness : (1/4”/ 3/8\"\" – liquid line and 5/8” –gas line) with standardthickness & length of 3 mtr.of copper tubing with insulation as per OEM standard. |
| 69 | iv)Refrigerant :R-32/as per OEM standard |
| 70 | v) Max current : As per OEM standard |
| 71 | vi) Interconnecting wiring in between outdoor and indoor as per standarad specification and length -3 mtr. |
| 72 | vii) Condensing Coils - 100% copper |
| 73 | viii)body – Powder coated shade whitescratchless (as per OEM) |
| 74 | Warranty Period : 01 year of complete Unit with all spares and 05 years minimumfor compressor & PCB’s |
| 75 | Note : 1) Additional featuresif any as per the OEM standards (inclusive ) |
| 76 | Providing, installation, commissioning and testing at siteElectronic voltage stabilizer, single phase ,50 Hz, IC tech, copper wound , as perIS : 8448:1989 Latest, Voltage fluctuationrange : 170to 270 V(minimum), Digital displayAmmeter/Voltmeter, built in thermal protection, under and over voltage cut out ,standard length of wire 3cx2.5mm2 warranty period – 2 years |
| 77 | Capacity 5 KVA |
| 78 | Providing, installation, commissioning and testing of Copper Tubing 20 Gwith nitriletube insulation 6mm thickincluding fittings etc as applicable in addition to the standard lengthof 3mprovided by OEM |
| 79 | Copper Tubing set(5/8”+3/8\"or 1/4”) |
| 80 | S/I/T/Cof following sizes of FRLS PVC insulated copper conductor, multi corewire laying withelectrical tie in tray , copper thimbledend connections as per the standard sizesfrom indoor to outdoor unitsand from main supply point to stablizer on wall / pvc conduit as per site requirment to the satisfaction of Engineer-in-charge , NIPER . |
| 81 | 3 core x 2.5mm² |
| 82 | 4 core x 2.5mm² |
| 83 | Providing, installation, commissioning and testing at site PVC moulded MCB DP with indicator, single phase, 50 Hz. As per site requirement . |
| 84 | Capacity - 32 amp |
| 85 | Supply and installing following size of perforated hot dipped galvanised iron cable tray (Galvanisation thickness not less than 50 micron) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling/ mounted on wall with G.I. suspendereds including G.I. bolts & nuts. etc. as required. |
| 86 | size 100 x 50 x 1.6mm |
| 87 | size 150 x 50 x 1.6mm |
| 88 | Supply and installing following size of tray covers made from perforated hot dipped galvanised iron sheet 20 G(Galvanisation thickness not less than 50 micron )bended and cutto size . Cover to be screwed to the tray at distance of 0.3 mtr with . Self tapping steel screws 3/4\"\". |
| 89 | size 100 x 20 x 1.6mm |
| 90 | size 150 x 20 x 1.6mm |
| 91 | Providing, installation of wall mounted MS stand heavy duty , powder coated made fromMS Sheet 12 G duly bended to size for installation of outer unit of split ACon wall compelte with nuts ,bolts,washers, horizontal and vertical angle supports, dash fastenersdia ½”x 4”length - 6nos ,rubber pads -4 nos to fit with the outer unit (as per OEM standard) as per site requirement to the satisfaction of Engineer-in- charge. |
| 92 | Support frame size as per OEM (Horizontal/Vertical ) |
| 93 | Providing and fixing of MS work,riveted,bolted or welded inbuiltup sections, and frame work including cutting,hoisting,fixing in position and applying priming coat of approved steel primer all complete as per site requirement |
| 94 | size 40x40x4mm |
| 95 | Minorworks such as making hole in wall /frame with drill machinebit/chisel & hammer as required for laying of copper tubing, cable and drain line and making good the same with cement replastering /white cement jointsand color washingas per site requirement to the satisfaction of Engineer-in-charge. |
| 96 | Extended yearlywarranty period for repair and maintenance AC services inclusive of all spares such as PCB for indoor and outdoor units. Cooling coils, blower motor, Condensor coil, Condensor fan motor, Refrigerant , compressor, remote etc for complete unit at site for 02 nounitsfor period of 2 years effective fromexpiry of 1st year of warranty . |
| 97 | Gas Tubing |
| 98 | Supply laying testing and commissioning of Stainless steel (SS) Grade304 tubing with color coded pvc sleeves etc. for distribution of gases O2,Co2 , LP gas from Gas cylinders -3 nos . of cap 7cum at G.floor to Lab at 2nd Floor , Block I. The tubing should becapable to withstand the gas pressure of minimum 20 bar in closed loop circuitwith leak proof joints as required at site to the satisfaction of the user . |
| 99 | 1/8\" (3.18 mm) × 0.085\" (2.1 mm) |
| 100 | S/I/T/C of SS 304 grade fittings along with the Gas tubing to provideleak proof joints end to end points i.e from Gas cylidersat G.Floorthruthe Manifold tolabat 2nd floor and to the equipment thru valvegas valvein use in labas per site requirement to the satisfaction of the user /inspection authority.. |
| 101 | SS Nutdia 1/8\", SS Tee dia 1/8\", SS Ferrules 1/8\", Gas valve 1/4\" |
| 102 | S/I/T/C of G.I. powder coated ( 150 micron) tray duly bend to size and with cover duly fixed with SS 1/8\"\" x 1/2\"\" screws on tray at 2 ft. distance. |
| 103 | 80x20x1 mm thick |
| 104 | S/I/T/C of high pressure gas manifold system ( Manual) for04 noscylindersmade from SS body & brass crome plated fittings to fit with the SS tubing dia 1/8\"\" to with stand the in letgas pressure ofmaximum 300 bar, complete with side pressure gauge dia 100 mm with range maximum 300 bar ,heavy duty mounting bracket fixed on wall to provide leakproof supply of gasfrom cyliders tothe end point inrespective Lab. |
| 105 | Two way type (suitable for two gas cylinders) |
| 106 | PVC casing caping for SS tubing ( 1/8\"\") |
| 107 | Size- 1/8\"\" |
| 108 | Pig tails SS braided for end to end connection for O2, Co2gastubing 1 mtr. Length |
| 109 | For 1/8\"\" SS tubing |
| 110 | Gas Cylinder mounting brackets ( powder coated) with chain size 25mm MS for cylinders duly mounted with cage/ wall. |
| 111 | 100x100x3 mm thick |
| 112 | Supply, installation and testing of Gas regulator with SS body, SS diaphram double stage complete with SS gauges, knob type gaspressure regulator suitable for with standing inlet gas pressure of maxmum 300 bar and to be fitted withcylinders capacity 7 cum for leak proof joint. Make Esab |
| 113 | Oxygen Gas |
| 114 | Co2 Gas |
| 115 | Supply, installation and testing of standard size ISI certified Zinc alloyLPG regulator ,singlestage to be fitted with LPG cylinder complete online, knob type with all fittings as required and suitable for with standing inlet gas pressure of maxmum 20 barfor leak proof joint along withbrass Gas regulatingValve /knobof size dia 1/4\" at end point in lab . |
| 116 | standard size |
| 117 | Supply and installation of Cylinder cage for 3 nosgas cylinders Cap-7 cum and LPGcylindermade from MS sheet 22 gauge thick with ventilationand locking arrangement for 2 nos. of doors. Skeleton frame made from 65x25x2.5 mm thick rectangular pipe and with ms mesh size 40x40x2 mm. top side to be covered with ms sheet 20 gauge. full cage to be powder coated of required shade. Design( Assembly type as per drg ). |
| 118 | Size 6\"Lx4\"Wx7\"H |
| 119 | Differential Pressure Guages |
| 120 | S/I/T/C of differntial pressureGuages with SS304 grade sheet 22G cover box as per size of guage including fittings ,plastic tubings of required size , includingcutting of wall/finishingto size and fixing as per site requirement for measuring differential pressure in Labto the satisfaction of the user /inspection authority . |
| 121 | Pressure range : 0-10 mmwater |
| 122 | Type of Guage : Analog |
| 123 | Connection size/type:1/2 inches , NPT |
| 124 | Dial type : dry |
| 125 | Tube: PTFE for inletand outlet 200mm length each |
| 126 | Mounting flush type |
| 127 | Preferred Make :Dwyer/Magnehelic/Sensocon/ equivalent branded |
| 128 | Size : 100mm dial |
| 129 | Biometric system |
| 130 | Password protected Access control, wall mounted ,confirming to IEC60950-1:2005(2nd edition)standard of ERTL (which is part of STQC) |
| 131 | Reader Type: Proximity,Pin, Card |
| 132 | Screen size :2.5 inch |
| 133 | CPU 32 bitCPU,digital signal processor |
| 134 | Finger print sensor- optical sensor |
| 135 | USB disk |
| 136 | LED -2 nos |
| 137 | key board - feather touch ( withback light)as per OEM |
| 138 | Communication interface : USB/TCPIP(10/100Mbps |
| 139 | 3G supported : SIM card |
| 140 | Finger touch sensor |
| 141 | voice output : multicolor LEDand LCD including buzzer |
| 142 | RTC |
| 143 | user capacity : 1000 finger+1000 pin minimum |
| 144 | identify mode : FP,password and its combination |
| 145 | USB disk link :enroll data,log |
| 146 | Matching speed: 1:2000 .<= 0.8 s |
| 147 | verification time:< 1sec |
| 148 | Finger rotation :360 deg |
| 149 | operating Voltage :5 VDC/12V DC |
| 150 | Humidity :20-80 % |
| 151 | External inputs and outputs :Exit switch and door sensor |
| 152 | Preferred brands:Hikvision/Godrej/secureye/equivalent branded |
| 153 | Air curtain |
| 154 | S/I/T/C of Air curtaincomplete with required fittings, accessoriesetc asrequired at siteto the satisfaction of the user/inspection authority |
| 155 | Air velocity : 9-11 m/s |
| 156 | Noise level < 70 DB |
| 157 | Copper high speed motorcontinuous operation run 5000 hrs |
| 158 | Speed Control : thru remote control |
| 159 | Full steel cabinet :SS304 |
| 160 | Preferred Make Totaline/Carrier/Mitsubishi/equivalent branded |
| 161 | Door size : 4 Ft |
| 162 | Air purifier |
| 163 | S/I/T/C of Air purifier complete with required fittings, accessoriesetc required at siteto the satisfaction of the user/inspection authority |
| 164 | Filtration stages , minimum 3 stage (pre filter,HEPA filter,activated carbon filteretc) |
| 165 | PM2.5 Display and color indicator |
| 166 | CADR -250 minimum |
| 167 | color - white ,Air changes per Hour: 3 |
| 168 | Lab Floor area 300 sq ft approx |
| 169 | Hepa life min 15000 hrs |
| 170 | Noise level 45dB max |
| 171 | fan speed - 3 steps minimum |
| 172 | Preferred Make : phillips/MI/carrier/equivalent branded |
| 173 | Fly Catcher |
| 174 | S/I/T/C of Fly /insect catcher complete withblue tubes, grid with current , required fittings, accessoriesetc required at siteto the satisfaction of the user/inspection authority |
| 175 | Floroscent Tube watt : 18 watts |
| 176 | Tubes : 2 nos |
| 177 | High voltage mesh |
| 178 | covered area :300 sq ft |
| 179 | Metal powdered coated body |
| 180 | Makes : phillips/Fly o flash/iBell/equivalent branded |
| 181 | size :650x90x282 mm +-10 % |
| 182 | UV Light with Fitting |
| 183 | S/I/T/C of UV light of specified wattage for tissue culture Lab complete with fittings and fixing and electrical connections at site |
| 184 | Length : 36 inches |
| 185 | Mounting: ceiling mounted |
| 186 | Preferred Make: phillips/Havell\"s/equivalent branded |
| 187 | Wattage: 30W |
| 188 | Fire extinguishers |
| 189 | S/I/T/Cof ABCdry powdertype in MS cylinderpowder coatedpost office red shade with control valves,handle,hopper, wall mounted with clamps in completeetcconfirming to IS 4308(2003) . Preferred Makes safex/Eco/equivalent branded |
| 190 | ABC type 4 Kg |
| 191 | PART - A2 |
| 192 | AIR HANDLING UNIT (DOUBLE SKIN) |
| 193 | S/I/T/C ofAHU complete in all respects as per site requirements with specifications as below |
| 194 | BODY |
| 195 | Double Skin AIR HANDLING UNIT Comprising of Framework Assembled Out of Extruded AluminIum Thermal Break Profiles and Perralumin Nylon Glass, Fibre Reinforced Corner Joints Having Double Skin Sandwich Panels Injected with PUF 43 mm,PUF insulation panel of density 40 ± 2 Kg/m³,Panel inner sheetGI 0.6 mm and outer sheet 0.6 mm Pre Painted GI .Drain pan SS 304 (18 swg).Base Section (GI).Limit switch, Marine light, |
| 196 | FILTERS WITH FILTER SECTION(MAKE-TRUE AIR,THEMODYNE or equivalent brand ,) |
| 197 | Pre FilterEU-4]: Flangetype,Al. const.,Washable HDPE,90% down to 10µ With Mixing.Fine filter[EU-5]: AHU mounted,Flange type,AL construction, to remove particles down to 5Microns with an efficiency of 95 %.Hepa Filter[EU-6] : AHUmounted , Al construction,to remove particles down to 3 microns , an efficiency of 99.97 % |
| 198 | DXCOIL |
| 199 | Casing:G.I.sheet/MOC Tube:0.4mm thick,12.5mm dia,Copper,Hydraulically tested at 250psi./MOC Fins:0.16 mm thick,Aluminum,12 fins/inch properly bonded with tube/Face Velocity:@500FPM/6Row Deep |
| 200 | HEATER as per OEM Design |
| 201 | PLUG FAN |
| 202 | Make:Nicotra / Rosenberg |
| 203 | Type: Plug Fan |
| 204 | MOTOR (IE-3) |
| 205 | Preferred Make : Crompton,/Bharat Bijali |
| 206 | Type:TEFC,IP:55,Foot Mounted, Poles: 2 or 4/RPM:1440/2800, Volts:3Ø,415,Mounting:Heavy duty channels,motor should move on both axis[X & Y] |
| 207 | MEGNEHELIC GAUGE(MAKE-DWYER, GALAXY, BOUMER) |
| 208 | 0-25 FOR PRE FILTER |
| 209 | 0-50 FOR FINE FILTER |
| 210 | VOLUME CONTROL DAMPERS |
| 211 | Type:Box,Aerofoil profile opposed blade,Gear driven,Low Leakage/MOC: 18 swg Extruded Aluminum./Other:Marked for Open & Closed./Location-AHU Supply, Return, Fresh air |
| 212 | U-Bend |
| 213 | AHU :- 2000 CFM SP 125 MMWG |
| 214 | CONDENSING UNIT 5.5 TR (Carrior/Voltas) |
| 215 | Distributors |
| 216 | Expansion Valve(MAKE-DANFOSS) |
| 217 | Copper Piping with Insulationfor suctin line- 7/8 \" |
| 218 | Copper Pipingfor discharge line-1/2 \" |
| 219 | Tray-GI(22 SWG) |
| 220 | Condensing Unit Stand Heavy duty |
| 221 | Dryer |
| 222 | Installation Charges |
| 223 | Relative Humidity (RH&Temperature Controller(Modle-7524) |
| 224 | Aluminium Grill & MS Black Damper |
| 225 | SIZE :- 300 X 300 mm |
| 226 | DUCTING |
| 227 | Factory / Site Fabricated GI ducting as per IS Standard with RTV sealant & 3 mm thkRubber gasket strips complete with supporting hangers, reavets, nut- bolts , threaded rod, fasteners etc.Fabrication of ducts shall be through Lock forming machines. |
| 228 | 24 Guage Ducting |
| 229 | INSULATION |
| 230 | Supplying , installation, testing & commissioning of external thermal insulation on DUCTS with Closed Cell Cross Linked Polythylene (XLPE) Foam of density 25±3 Kg/m³& thermal Conductivity not exceding 0.035 W/mK at an average Temperature of 40°C. The Material will be rated as Class O, |
| 231 | 12 MM THICK (For Return) |
| 232 | ELECTRICAL PANEL (DX& HEATER) |
| 233 | Electrical panel with RYB Indicators, (suitable capacity of MCB ),Contactors(DOL&Heater,) ,O.L.R For DOL,start/stop push button(D.O.L& VFD),Auto/Manual Selector Switch(V.F.D&D.O.L),ON/OFF Selectore Switch(DX&Heater),On/off trip(D.O.L) ,Indicatore, Electrical Panel Shall Be Totally enclosed,with Hinged Doors, Gasket .Suitable For Locking Arrangement and VFD Port. arrangement. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy