| 1 | Excavating inpost holes( or similar holes) each n exc0.50 cum, getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C2, using 40mm graded stone aggregate,asin foundation filling & mass concrete complete all as specified and directed. |
| 3 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165and similar workcomplete all as specified and directed. |
| 5 | S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm longcomplete all as specified anddirected. |
| 6 | M&L forMild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wirecomplete all as specified and directed. |
| 8 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed. (each line wire to be measured) |
| 9 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 10 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 11 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 12 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 13 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 14 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortaretc complete all as specified and directed |
| 15 | Demolition of cement concretein ground floorand paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed. |
| 16 | Dismantling of fencing anytypecomplete all as specified and directed. |
| 17 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Posts embedded in Concrete, brick work, masonry, etccomplete all as specified and directed. |
| 18 | M&L for 75mm thick PCC 1:3:6 type C1(Using 20mm graded stone aggregate) as in plinth protectionfinishedeven and smoothwithout using extra cement complete all as specified and directed. |
| 19 | M&L for exterior grade(Lequre coated), coloured glossyfinish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thickset, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. completeincluding provision of 20mm screed in cement moertar 1:6, complete all as specified and directed. |
| 20 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; completeall as specified and directed. |
| 21 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for preparing plastered or unplastered old surface of walls including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss efflorescent salts and trading oil and greasy spots and applying one coat of white (Lime) wash on wall complete all as specified and directed. |
| 23 | M&L for applying two coat of white washing (Lime wash white) including prepration of old decorated plastered/ unplastered surface of walls by brooming down, scraping, cleaning and removing smoke soot, moulds, moss and efflorescence complete all as specified and directed |
| 24 | M&L for preparing plastered or unplastered old surface of ceiling including brooming down or scrapping down with steel wire brushes, smoke soot, moulds, moss efflorescent salts and trading oil and greasy spots and applying one coat of white (Lime) wash on ceiling complete all as specified. |
| 25 | M&L for preparation of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of height upto 25Mtrs from ground level complete all as specified and directed. |
| 26 | M&L for for complete removal of existing treatment of wall and preparing surface of walls applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over existing surfaces of height upto 25Mtrs from ground level complete all as specified and directed. |
| 27 | M&L for repair of existing discontinued down roof and earthing aluminium /GI strip by providing newAluminium/GI Strip through PVC conduit 40 mm bore alongwith GI clamps made by 32x3 mm flat ironwithtwo numbers of anchor bolts of size 80mmx102mm by drilling of brick/RCC wall incluing masonary work as required for making good the disturbed surface complete all as specified and directed.Note: (a) All the materials required to complete the work at site such as wooden plugs, Nut, bolt, Washers, shaddles, fixing screw GI Clamps PVC conduit etc shall be provided by the contractor and deemed to be included in quoted rate.(b) The contracor provide03 nos of GI clamp in each RM of PVC conduit and03 Nos of insulator in each RM of GI/ Al strip for fixing on wall /roof. |
| 28 | Supply only aluminium strip 25 x 3 mm including replacement of insulating blocks complete all as specified and directed. |
| 29 | Supply only Galvanised iron strip 25x4 mm as continuity conductor complete all as specified and directed. |
| 30 | Supply and fixingAir termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 31 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screw complete all as specified and directed. |
| 32 | S&F in replacement of Air Termination rod 300mm longconnected with GI pipe 40 mm dia (Medium grade) two meterlength fixing the same with the help ofclamp 4 sets of suitable size including anchor bolt 100mm long 6 nos including allfixing accessories to fixed at the top of the bldg complete all as specified and directed. |
| 33 | Material and labour in repairs ofearth pit of earthing including replacement of broken RCC cover by new 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including formwork complete all as specified and directed. |
| 34 | M & L for testing of earth resistance of existing earth pit as and when required using earth resistance testing equipments as directed by the GE and producing the test result for recording purpose complete all as specified and directed.Note: (i) Testing of each earth pit shall be measured as one unit. (ii) All test result to be entered into a register properly bound and covered and to be submitted to the Engr-In-Charge duly sign by user rep.(iii) For the purpose of testing, contractor shallarranged the all necessary equipments and apparatus/ instruments at his own cost without any extra claim. |
| 35 | M&L for testing of lightning conductor for its continuityseparately of each test point to using meggerand other necessary tools, plants and equipments including rectification of the discontinuity complete all as specified and directed. Note: (i) Before testing the continuty of the lightening conductor disconnect all the conductor from test point.(ii)Testing of each pointshall be measured as one unit. (iii) All test result to be entered into a register properly bound and covered and to be submitted to the Engr-In-Charge duly sign by user rep.(iv) For the purpose of testing, contractor shallarranged the all necessary equipments and apparatus/ instruments at his own cost without any extra claim. |
| 36 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 32 mm bore light grade GI pipe for protection of earth lead including provision ofconcrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing earthing complete all as specified and directed. |
| 37 | M&L in replacement for Advance Maintenance Free ASEEL-39 zinc & alloy coated GI safe earthing electrode with pipe in pipe technology of not less than 76.20 mm outer dia and 41.9 mm inner dia and three meterlength, The electrode should be ofgalvinised with zinc(80 -100 micron) and alloy ( 200 - 250 micron) coated along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg BackFill compoundto provide maximum contact between the electrode and BackFill Compound. Backfill compound should be eco-frendly and having RoHs certification .GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC (1:2:4 type B-1) cover, ofsize 450 x 450 mm complete all as specified and directed. Zinc and alloy coated safe earthing electrode complete all as specified and directed. Note:(i) For earth electrode, excavation to be done of size not less than3M x 0.75M X 0.75M and excatied soil to be replace with good quality/highly conductive soil, rate for the same shall be deemed to be included in the quoted rate. (ii) Earth Resistance should be less than 2 ohm.(iii) All earth connection to be done using special steel nut bolt. |
| 38 | Material and labour in repairs ofPCC block size 300x200x150 mm use (1:2:4) type B1with two coats synthetic enamel paint (Brown) first qualityincluding replacement of insulator mounted on itcomplete all as specified and directed. |
| 39 | Taking down old unserviceable PTL and bollardlight fittings of any type/modelincluding associated accessories from wall / other similar situation and keep in safe costudy for depositing thesame in MES store yard complete all as specified and directed. |
| 40 | Supply andfixing decorative LED post top light fitting white diffuser moon type 200 mm dia luminaires made up of high grade unbreakable polycarbonate material lamp B22 base including LED bulb 9 watt complete with all accessories duly prewired and connecting to junction box and testing complete all as specified and as directed. |
| 41 | Supply andfixing LED Post top light fittting luminaires 40/45 Watts IP 65 type made in die-cast aluminium housing with decorative opal/clear polycarbonate diffuser complete with control gear box suitable for 50 mm dia post and all accessories duly prewired and connecting to junction box and testing complete all as specified and directed. |
| 42 | Supply only PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 1.5 Sqmm 3 Core (Nominal Area) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed. |
| 43 | Supply and fixing pole mounted SMC junction box/bus bar chamber for loop IN/OUT connection of street light cable of size 295x195x100 mm high heat distoration temperature, non-fusing , shockproff, rustproof, 100 % weatherproof, fire retardant- class FV-O as per IS 11731 Part-II and suitable locking arragement with three phase and neutral aluminium busbar of size 20X3 mm of length 170 mm wrapped with PVC sleeves with maintained the colour code, MCB DIn rail channel for mouting of one no MCB SP and provision of making holes with GI nuts, bolts & washers for cable connections mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and fixed on pole steel/PCC with suitable two nos flat iron clamp 25x4 mm with nuts and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) and dismantling of old unserviceable one complete all as specified and as directed.complete all as specified and directed.Make: Sintex , Cat No: GSJB3020 or equivalent model as listed in list of make. |
| 44 | S & F in replacement power contactor single pole,40Amps capacity panel mounting with entry terminals,including dismantling old one complete all as specified and directed. Make: L & T Cat No: CS 94992 or equivalent as listed in list of make. |
| 45 | M & L forCross arms, bracing, supports, clamps and back plate, fabricated from structural steel sectionincluding nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 46 | Supply,laying & fixing double wall corrugated (DWC) pipes ofsize 50 mm outer dia conforming to IS 16205 (Part-24) including all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc complete all as specified and directed. |
| 47 | M&L for taking out old unserviceable cable of any size , GI pipe protection, bricks including separating serviceable bricks & set aside and removing un-serviceable bricks from position complete all as specified and directed. |
| 48 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm2core with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed.(NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule \"A\" part). |
| 49 | Relaying of old serviceable UG cable of any size obtained from item no 47.00 complete as specified and directed. |
| 50 | Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete as specified and directed. |
| 51 | Returning filling including spreading levelling watering & well Ramming in layers not exc 25 cm complete as specified and directed. |
| 52 | Removing excavatedmaterial not exceeding 50 mtr & deposited where direceted at a level not exceeding 1.5 mtr above the ground level complete as specified and directed. |
| 53 | M/L for bricks common burnt sub class B designation for protection of cable complete as specified and directed. |
| 54 | Relaying of old serviceablebrick as in cable protection complete as specified and directed. |
| 55 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete as specified and directed. |
| 56 | Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3½core XLPE, armoured, Aluminium conductor cable of size 10 to 16 sqmm complete as specified and directed. |
| 57 | Ditto all as per item 56.00 but of size 25 to 35 sqmm. |
| 58 | Supply and fixing in repair epoxy resin 4 way terminal connector with nuts, bolts and washer for 16 sqmm UG cable including fixing to stret light junction box complete as specified and directed. |
| 59 | M&L for alignment of galvanised lantern carriage arrangement for luminaires of high mast pole any size and any location with the help of hydra or other source which are locked/disalignment due to windcomplete as specified and directed. |
| 60 | M&L for rewinding of reversibleMotor capacity 1.5 HP any makeused for lowering and hosting the carriage of luminaires for repair complete as specified and directed. |
| 61 | M&Lin replacement of Motor capacity 1.5 HP for hosting and loweing of lantern carriage for repair oflight from high mast pole complete as specified and directed. |
| 62 | Supply and fixing in reapir PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 4 Sqmm 5 Core (Nominal Area) from pole junction box to light fitting of High mast pole with suitable size copper cable lugs and connector all complete as specified and directed. |
| 63 | Supply and fixing in repair LED type 4 watt single aviation light SLE ALS LDR SEN IP 65on high mast pole/water tank/high rising building complete all as specified and directed. |
| 64 | All as per item ser No 63.00 above but cap 8 Watt double aviation light all as specified and directed. |
| 65 | Supply and fixing of information board duly fabricated with flexo sheet of high grade quality and writing/printing of information/picture/drawing/layout plan over flexo sheet duly structure framed made out 25x25 mm mild steel rectangular iron pipe and fixed with suitable screws/paste including dismantling of old unsv information board complete as specified and directed. |
| 66 | Supply and fixing laminated and Illuminated Glow Sign Board made out of 2.00 mm thick Flexo printed sheet of approved quality of different size one side luminous front with frame made out 25x25 mm mild steel rectangular iron pipe covered with 20 guage (0.090 mm) PGI sheet on back, sides, top & bottom, aluminium channel 25x25x1.5 mm thick and back side totally enclosed water tight cubical for housing 2 nos LED 9 watt tube light fitting with electronic driver with complete prewired per sqm with connecting lead in common connection with 3 core sheathed wire from junction box to glow sign board (Approx 10 mtrs) and computerized designed letters, figures, pictures, drawings, map etc as directedincluding dismantling of old unserviceable glow sign board complete as specified and directed. |
| 67 | Supply and fixing in repair of glow sign boardmade of 3 mm bakelite sheet blue colour in front side including cutting the bakelite sheet as per size of letter ( size of font decided by GE ) back side of blue colour bakelite sheet fixed 2 mm thick acrylic sheet white colourandfixed LED 9 strip with driverof suitabe wattagefor luminaries at night vision. Outer frame of board should be made out of 3 mm thick flat iron and galvanised iron sheetand back side of the board should be covered with(0.90 mm) PGI sheet on back sides ,top & bottom with support of 4x32 mm flat iron duly welded with out frame of glow sign board complete as specified and directed. Note : The contractor will submitted a sample for approval of GE before place order. |
| 68 | M&L earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision ofconcrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing complete as specified and directed. |
| 69 | S &F in repair of digital loadcell for weighbridge of capacity 60 ton including taking down old one complete as specified and directed. |
| 70 | S&F in repair of box pcb with surge protection for weighbridge including taking down old one complete as specified and directed. |
| 71 | S&F for USB Communication modulefor weighbridge including taking down old one complete as specified and directed. |
| 72 | S&F for Additional display PCB for weighbridge taking down old one complete as specified and directed. |
| 73 | Supply and fixingAir termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 74 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75x 25mm drilled and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screw complete all as specified and directed. |
| 75 | Supply only aluminium strip 25 x 3 mm including replacement of insulating blocks complete all as specified and directed. |
| 76 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 80,555.00 (refer Tender Srl Page No 28). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |