| 1 | Decription of items |
| 2 | Earth work in excavation, DSR_2023_2.6.1 |
| 3 | Surface dressing of the ground including removing vegetationAll kinds of soil ,, DSR_2023_2.28.1 |
| 4 | Finishing walls with Acrylic Smooth exterior paint Old work (Two or more coat , DSR_2023_13.111.2 |
| 5 | Painting with synthetic enamel paint One or more coats on old work , DSR_2023_13.99.1 |
| 6 | Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete. , DSR_2023_13.91 |
| 7 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , DSR_2023_13.8 |
| 8 | Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs,, DSR_2023_22.23 |
| 9 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes,110 mm diameter , DSR_2023_12.41.2 |
| 10 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conformingto IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°,110 mm bend.,, DSR_2023_12.42.5 |
| 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge,With cement mortar 1:4 (1 cement : 4 fine sand),, DSR_2023_14.1.1 |
| 12 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : |
| 14 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) , DSR_2023_5.1.2 |
| 15 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources, DSR_2023_5.2.2 |
| 17 | Centering and shuttering including strutting, propping etc. and removalof form for |
| 18 | Foundations, footings, bases of columns, etc. for massconcrete , DSR_2023_5.9.1 |
| 19 | Columns, Pillars, Piers, Abutments, Posts and Struts, DSR_2023_5.9.6 |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position a |
| 21 | Steel reinforcement for R.C.C. work, DSR_2023_5.22.6 |
| 22 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete, DSR_2023_10.2 |
| 23 | Brick work Cement mortar 1:4, DSR_2023_13.7.2 |
| 24 | 12 mm cement plaster 1:4, DSR_2023_13.7.2 |
| 25 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge, DSR_15.7.4 |
| 26 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat ofapproved steel primer,, DSR_2023_10.5.1 |
| 27 | Providing and fixing ACP Board, DSR_2023_2631 |
| 28 | Providing and fixing M.S. Tubular frames for doors, windows, ventilatorsand cupboard with rectangular/ L-Type sections, made of 1.60 mm thickM.S. Sheet, joints mitred, welded and grinded finish, with profiles ofrequired size, including fixing of necessary butt hinges and screws andapplying a priming coat of approved steel primer. |
| 29 | Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size), DSR_2023_10.15.1 |
| 30 | Taking out existing wooden door shutter, repair by cutting, paintingetc. and refixing of repaired door shutters to existing door frames,including replacement of hinges with screws, etc. as required, allcomplete as per the direction of the Engineer-in-charge, DSR_2023_14.85 |
| 31 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead, DSR_2023_15.12.1 |
| 32 | Wall painting with acrylic emulsion paint, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required,to achieve even shade and colour, DSR_2023_13.82.2 |
| 33 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with \"S\" or \"P\" trap including dismantling of oldWC seat and \"S\" or \"P\" trap at site complete with all operationsincluding all necessary materials, labour and disposal of dismantledmaterial i/c malba, all complete as per the direction of Engineer-incharge. |
| 34 | Orissa pattern W.C Pan of size 580x440 mm, DSR_2023_14.80.2 |
| 35 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require: |
| 36 | White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps, DSR_2023_17.7.1 |
| 37 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge, DSR_2023_17.22a |
| 38 | Providing and fixing solid plastic seat with lid for pedestal type W.C.pan complete |
| 39 | White solid plastic seat with lid, DSR_2023_17.20.1 |
| 40 | Providing and fixing P.V.C. low level flushing cistern with manuallycontrolled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. |
| 41 | 10 litre capacity - White, DSR_2023_17.18.1 |
| 42 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrick honey comb shaft with bricks and S.W. drain pipe 100 mmdiameter, 1.8 m long complete as per standard design, DSR_2023_19.32.1 |
| 43 | Providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of W.C., kitchen and thelike consisting of, DSR_2023_22.3 |
| 44 | Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retainingwalls of the basement, water tanks, roof slabs, podiums, reservior,sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystallineslurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integralcrystalline slurry : 1 part water) for horizontal surfaces and applyingthe same from negative (internal) side with the help of synthetic fiberbrush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than90% compared with control concrete as per DIN 1048 and resistantto 16 bar hydrostatic pressure on negative side. The crystalline slurryshall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification andthe direction of the engineer-in-charge. The product performance shallcarry guarantee for 10 years against any leakage., DSR_2023_22.3.1 |
| 45 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters. |
| 46 | 30 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws, DSR_2023_9.20.2 |
| 47 | 35 mm thick factory made Solid panel PVC Door shutter, made out ofsingle piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, havingstyles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out ofwhich 75 mm shall be flat and 20 mm shall be tapered (on both side),having one side thickness of 15 mm integrally extruded on the hingeside of the profile for better screw holding power, including reinforcingwith MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails tobe mitered cut & joint with the help of PVC solvent cement, self drivenself tapping screws & M.S. rectangular pipes bracket of size 190 mm X100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner.Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x35 mm, out of which 75 mm to be flat and 20 mm to be tapered at bothends, having 15 mm solid core in middle of rail section integrallyextruded, fixing the styles & rails with the help of solvent and self drivenself tapping screws of 125 mm x 11 mm, including providing 5 mmSingle piece solid PVC extruded sheet inserted in the door as panel, allcomplete as per manufacturer\"s |
| 48 | Non decorative finish (matt finish), DSR_2023_9.142.1 |
| 49 | Providing and fixing PVC Door Frame of size 50x47 mm with a wallthickness of 5 mm (± 0.2 mm), made out of single piece extruded PVCprofile, with mitred cut joints and joint with 2 nos of PVC bracket of size190 mm x 100 mm long arms of cross section size 35 x 15 mm & selfdriven self taping screws, the vertical door profiles to be reinforced with40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDMrubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile.The door frame to be fixed to the wall using 8 x100 mm long anchorfasteners complete, all as per manufacturer\"s specification and directionof Engineer -in- charge, DSR_2023_9.141 |
| 50 | Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheetscomplete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. |
| 51 | 0.63 mm thick with zinc coating not less than 275 gm/ m², DSR_2023_12.1.3 |
| 52 | Providing fitting & fixing Piller Cock of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (JAQUAR/hindware) |
| 53 | Providing and fixing C.P. brass long nose bib cock of approved qualityconforming to IS standards and weighing not less than 810 gms(JAQUAR/hindware), DSR_2023_18.50.1 |
| 54 | Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931(JAQUAR/hindware), DSR_2023_18.52.1 |
| 55 | Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:8931(JAQUAR/hindware), DSR_2023_18.53.1 |
| 56 | Providing and fixing Hand faucetof approved quality conforming to IS:8931(JAQUAR/hindware) |
| 57 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete, DSR_2023_17.28.2.1 |
| 58 | Providing and fixing uplasticised PVC connection pipe with brassunions :, DSR_2023_18.21.2.1 |
| 59 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. |
| 61 | 20 mm nominal dia Pipes, DSR_2023_18.7.2 |
| 62 | 25 mm nominal dia Pipes, DSR_2023_18.7.3 |
| 63 | Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing,Rectangular shape 453x357 mm, DSR_2023_17.32.2 |
| 64 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conformingto IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matchingpigments etc., complete, DSR_2023_11.38 |
| 65 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead., DSR_2023_15.23.1 |
| 66 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete, DSR_2023_8.31 |
| 67 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank, DSR_2023_18.48 |