| 1 | Construction of storm water drain from MCD pry. School no.3 to maleria office and up to culvert near B-block Dakshinpuri in ward no. 165(Madangir)/SZ. |
| 2 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 4 | 110.25.1:Excavation in nalla/drains in running condition including taking out and disposal of excavated silt/sludge/rubbish/earth mixed malba etc. from the drain, culvert and other similar conditions under sumberged/foul condition within 50 metre lead and 1.5 m lift, blocking drain in the required length by placing sand filled bags and pumping out water including removal of stone, brick bats, cloating material etc. before excavation. a) Open nalla |
| 5 | 110.18:Providing and laying compacted bed of dry brick aggregate of 40/50 mm thick nominal size in required thickness including spreading, well ramming, consolidating and grouting with Jamuna sand including finishing smooth etc. complete as per direction of Engineer-in-charge (compacted thickness to be measure for the purpose of payment) |
| 6 | 6.1.2:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) |
| 9 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 11 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 12 | 19.6.5:Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:450 mm dia R.C.C. pipe |
| 13 | 110.12:P/F precast R.C.C. stab/grating 70mm thick manufactured with CC 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) reinforced with 96 kg/m3 of R.C.C including lapping all four side with M.S. sheet 1.6 mm thick & fixing in position complete. (Drain covers with or without holes) |
| 14 | 1.1.1_05:Disposal of materials by mechanical transportincluding loading ,unloading and stacking lime ,moorum, buildingrubbish for lead 5 km |