|
| 1 | PHED O&M BSR 2020 Ch. - 2Lwering & UnloweringUnlowering of submersible pump set along with lowering pipes with depth up to 120 mtr and submersible cable with safety from tube well, checking the pump set, transportation of pump set from tube well site to storeas direction,receiving repaired / new pump set from store/ divisional store , testing the same, transportation tosite and lowering back into tube well along with submersible cable, lowering pipes,specials etc and commissioning of the tube well. The job also includes cable jointing,checking of discharge of pump set,interconnection of lowering pipe from nearby distribution pipe line,checking of starter and reporting for completion of Job or fault/problem if any. (Upto 20 Km distance run by lowering machine) |
| 2 | For three Phase pump setG.I. Double Flanged Pipe Lowering Assembly of nominal dia 50 mm |
| 3 | 65 mm |
| 4 | 80 mm |
| 5 | HDPE Pipe Lowering Assembly of nominal dia 63 mm |
| 6 | 75 mm |
| 7 | 90 mm |
| 8 | Add above item 1.1 for depth above 120 mtr for each 10 mtr depth 10% |
| 9 | Add above item 1.1 for distance run above 20 Km for each 5 Km distance run.10 % |
| 10 | For singlePhase pump set G.I. Double Flanged Pipe Lowering Assembly of nominal dia 32 mm |
| 11 | 50 mm |
| 12 | HDPE Pipe Lowering Assembly of nominal dia32 mm |
| 13 | 40 mm |
| 14 | 50 mm |
| 15 | Add above item 1.1 for depth above 120 mtr for each 10 mtr depth 10% |
| 16 | Add above item 1.1 for distance run above 20 Km for each 5 Km distance run.10 % |
| 17 | Only unlowering of submersible pump set along with lowering pipes depth up to 120 mtr and submersible cable with safety from tube well, checking the pump set,reporting and transportation of pump set from tube well site to storeas per direction. |
| 18 | For three phase pump setG.I. Double Flanged Pipe Lowering Assembly of nominal dia50 mm |
| 19 | 65 mm |
| 20 | 80 mm |
| 21 | HDPE Pipe UnLowering Assembly of nominal dia 63 mm |
| 22 | 75 mm |
| 23 | 90 mm |
| 24 | Add above item 2.1 for depth above 120 mtr for each 10 mtr depth10% |
| 25 | Add above item 1.1 for distance run above 20 Km for each 5 Km distance run.10 % |
| 26 | For singlePhase pump setG.I. Double Flanged Pipe Lowering Assembly of nominal dia 32 mm |
| 27 | 50 mm |
| 28 | HDPE Pipe Lowering Assembly of nominal dia32 mm |
| 29 | 40 mm |
| 30 | 50 mm |
| 31 | Only lowering of the submersible pump setinto tube well along with submersible cable, lowering pipes depth up to 120 mtr,specials etc and commissioning of the tube well. The job also includes cable jointing,checking of discharge of pump set,interconnection of lowering pipe from nearby distribution pipe line,checking of starter and reporting for completion of Job or fault/problem if any. |
| 32 | For three phase pump setG.I. Double Flanged Pipe Lowering Assembly of nominal dia50 mm |
| 33 | 65 mm |
| 34 | 80 mm |
| 35 | HDPE Pipe Lowering Assembly of nominal dia 63 mm |
| 36 | 75 mm |
| 37 | 90 mm |
| 38 | Add above item 3.1for depth above 120 mtr for each 10 mtr depth 10% |
| 39 | Add above item 1.1 for distance run above 20 Km for each 5 Km distance run.10 % |
| 40 | For singlePhase pump set G.I. Double Flanged Pipe Lowering Assembly of nominal dia32 mm |
| 41 | 50 mm |
| 42 | HDPE Pipe Lowering Assembly of nominal dia32 mm |
| 43 | 40 mm |
| 44 | 50 mm |
| 45 | Add above item 1.1 for depth above 120 mtr for each 10 mtr depth 10% |
| 46 | Add above item 1.1 for distance run above 20 Km for each 5 Km distance run.10 % |
| 47 | Increasing of lowering pipes intube wells including cost of nut bolts and rubber gaskets / jointing material and PVC rope and transporatation of cable and extra lowering pipe from store.. However submersible cable and extra lowering pipe shall be provided by the department at store. |
| 48 | For three phase pump setG.I. Double Flanged Pipe Lowering Assembly of nominal dia ( For incease up to 30 Mtr length of pipe)50 mm |
| 49 | 65 mm |
| 50 | 80 mm |
| 51 | HDPE Pipe Lowering Assembly of nominal dia63 mm |
| 52 | 75 mm |
| 53 | 90 mm |
| 54 | For singlePhase pump set G.I. Double Flanged Pipe Lowering Assembly of nominal dia32 mm |
| 55 | 50 mm |
| 56 | HDPE Pipe Lowering Assembly of nominal diaFor Increase 20 Mtr Assembly pipe 32 mm |
| 57 | 40 mm |
| 58 | 50 mm |
| 59 | Add above item for depth above 20 mtr or two D/F pipe assembly for each 10 mtr depth 10% |
| 60 | Add above item for distance run above 20 Km for each 5 Km distance run.10% |
| 61 | Unlowering of pump set along with lowering pipes and submersible cable with safety from Openwell For three Phase pump set having G.I double flanged/ HDPEpipe lowering asembly of size 50 mm to 80 mm, checking the pump set,reporting and transportation of pump set from tube well site to store. Add above item for distance run above 20 Km for each 5 Km distance run.10% |
| 62 | Lowering of repaired/Newpump set alongwith lowering pipes and submersible cable with safety in Openwell For three Phase pump sethaving G.I double flanged/ HDPEpipe lowering asembly of size 50 mm to 80 mm. It includes receiving repaired / new pump set from store / Work shop with in boundry area of division and testing the same, transportation tosite and commissioning. Add above item for distance run above 20 Km for each 5 Km distance run. |
| 63 | Add above item for distance run above 20 Km for each 5 Km distance run.10% |
| 64 | PHED O&M BSR 2020 Ch. - 3 Rewinding of Submersible Motor Repair Rewinding of Submersible motor includes full servicing and rewinding (wherever required) as per manufacturer\"s specification and to the satisfaction of Engineer Incharge. It includes the replacement of minor parts such as bushes (oil seal bush) Nut Bolts, washers, cable seal, gland ring, vent plug, water drain plug, etc. complete job |
| 65 | Up to 3 HP V-6 |
| 66 | Above 3HP to 5 HP V-6 |
| 67 | Above 5HP to 7.5 HP V-6 |
| 68 | Above 7-5 HP to 10 HP V-6 |
| 69 | Above 10 HP to 12.5 HP |
| 70 | V-6 |
| 71 | V-8 |
| 72 | Above 12.5 HP to 15 HP |
| 73 | V-6 |
| 74 | V-8 |
| 75 | Above 15 HP to 17.5 HP |
| 76 | V-6 |
| 77 | V-8 |
| 78 | Above 17.5 HP to 20 HP |
| 79 | V-6 |
| 80 | V-8 |
| 81 | Motor opening cable jointing & refitting charges when rewinding is not required. |
| 82 | V-6 |
| 83 | V-8 |
| 84 | Particulars of spare parts of submersible Motor Providing & Replacement of G.M./S.S. Bushes for all types of motors (per set of 4Nos.) including cost of sleeves |
| 85 | V-6 |
| 86 | V-8 |
| 87 | Providing & Replacement of thrust bearing for all types of motor. It includes cost of all components connected with thrust bearing. |
| 88 | V-6 |
| 89 | V-8 |
| 90 | Replacement of thrust plate for all types of motors |
| 91 | V-6 |
| 92 | V-8 |
| 93 | Supply and fixing spare parts for repair of pump set including cost of opening refitting, servicing, and machining, if required. It also includes the cost of nut bolt, studs, washer packing, keys etc. complete. |
| 94 | Providing & fixing of GM neck rings parts on impeller. |
| 95 | Plain Type V-6 |
| 96 | Bowel typeV-6 |
| 97 | Plain Type V-8 |
| 98 | Bowel typeV-8 |
| 99 | Providing & Fixing of GM/SS bush per piece |
| 100 | Plain Type V-6 |
| 101 | Bowel typeV-6 |
| 102 | Plain Type V-8 |
| 103 | Bowel typeV-8 |
| 104 | Providing & replacement of G.M. Impeller |
| 105 | Plain Type V-6 |
| 106 | Bowel typeV-6 |
| 107 | Plain Type V-8 |
| 108 | Bowel typeV-8 |
| 109 | Providing & replacement of Nylon Impeller |
| 110 | Plain Type V-6 |
| 111 | Bowel typeV-6 |
| 112 | Plain Type V-8 |
| 113 | Bowel typeV-8 |
| 114 | Providing & fixing CI Diffuser/ guide vans per piece |
| 115 | V-6 |
| 116 | V-8 |
| 117 | Providing & fixing Gun metal Diffuser/ guide vans per piece |
| 118 | V-6 |
| 119 | V-8 |
| 120 | Providing & fixing Nylon Diffuser/ guide vans per piece |
| 121 | V-6 |
| 122 | V-8 |
| 123 | Providing & fixing Microlone Guide per piece |
| 124 | V-6 |
| 125 | V-8 |
| 126 | Providing & fixing of CI body per piece |
| 127 | Plain Type V-6 |
| 128 | Bowel typeV-6 |
| 129 | Plain Type V-8 |
| 130 | Bowel typeV-8 |
| 131 | Pump opening & fixing including machining & all finishing work for desired performance |
| 132 | Plain Type V-6 |
| 133 | Bowel typeV-6 |
| 134 | Plain Type V-8 |
| 135 | Bowel typeV-8 |
| 136 | Impeller welding & turning (if not replaced) |
| 137 | Plain Type V-6 |
| 138 | Bowel typeV-6 |
| 139 | Plain Type V-8 |
| 140 | Bowel typeV-8 |
| 141 | Repair Rewinding of single phase Submersible motor includes full servicing and rewinding (wherever required) as per manufacturer\"s specification and to the satisfaction of Engineer Incharge. It includes the replacement of bushes (oil seal bush) Nut Bolts, washers, cable seal set, cable gland ring, vent plug, water drain plug, etc. complete. |
| 142 | up to 2 HP V-4 |
| 143 | Above 2HP to 3 HP V-4 |
| 144 | Above 3HP to 4 HP V-4 |
| 145 | Providing and fixing of spare for Single Phase submersible motor. Providing & Replacement of G.M./S.S. Bushes for all types of motors (per set of 4Nos.) including cost of sleeves |
| 146 | Providing & Replacement of thrust bearing for all types of motor. It includes cost of all components connected with thrust bearing. |
| 147 | Replacement of thrust plate for all types of motors |
| 148 | Motor opening cable jointing & refitting charges when rewinding is not required each motor |
| 149 | Proving & fixing of motor pump coupling housing set |
| 150 | Repairing of submersible single phase pump setsProviding & Fixing of GM/SS bush per piece |
| 151 | Providing & replacement ofPVC Impeller |
| 152 | Providing & fixingGM Diffuser per piece |
| 153 | Providing & fixing Microlone Guide per piece |
| 154 | Providing & fixing of Bowl per piece |
| 155 | Pump opening & fixing including machining & all finishing work for desired performance |
| 156 | Providing & fixingNRV |
| 157 | Providing & fixingD.O. |
| 158 | Providing & fixing of S.S. shaftup to 2 HP |
| 159 | Above 2HP to 4 HP |
| 160 | PHED O&M BSR 2020 Ch. - 6 Stater Panel \Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter atheadworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc.. |
| 161 | Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department |
| 162 | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) |
| 163 | 5 to 15 HP. |
| 164 | 16 to 30 HP. |
| 165 | 31 to 60 HP. |
| 166 | 61 to 100 HP. |
| 167 | 101 to 150 HP. |
| 168 | Labour charges for repairing ofsoft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) |
| 169 | 5 to 15 HP. |
| 170 | 16 to 30 HP. |
| 171 | 31 to 60 HP. |
| 172 | 61 to 100 HP. |
| 173 | 101 to 150 HP. |
| 174 | Supply & filling starter oil in oil immersed starters at site. |
| 175 | Providing spare parts for repairing of starter for 3 HP to 125 HP different type of accessories as manufacturer price list. (Payment of suppy of material required for repair of starter panel shall be done with tender premium (Above / Below) with respect to price list of manufacturer) |
| 176 | Work for fishing out fallen pump set, assembly pipes/cable etc. from tube well (Total depth of tube well more than 120 mtr & up to 500 meter)In case of failure fishing no payment shall be paid to contractor. |
| 177 | PHED BSR/2023-24/ Chapter-2/2.14/Supply& Installationof single phase Isl marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includesloweringof motor pump, installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. |
| 178 | 2.14.1) Up to 2.0 KW |
| 179 | 2.14.2)Above 2.0 KW |
| 180 | PHED BSR/2023-24/ Chapter-2/2.15/Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 181 | 2.15.1) Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 182 | 2.15.2) Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 183 | 2.15.3) 7.5 KW (10 HP) & head up to 120 mtr. |
| 184 | 2.15.4) 7.5 KW (10 HP) & head above 120 mtr |
| 185 | 2.15.5) 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 186 | 2.15.6) 9.3 KW (12.5 HP) & head above 120 mtr. |
| 187 | 2.15.7) 11 KW (15 HP) & head up to 120 mtr. |
| 188 | 2.15.8) 11 KW (15 HP) & head above 120 mtr. |
| 189 | 2.15.9)3 KW (17.5 HP) & head up to 120 mtr. |
| 190 | 2.15.10) 13 KW (17.5 HP) & head above 120 mtr. |
| 191 | 2.15.11) 15 KW (20 HP) and above, head up to 120 mtr. |
| 192 | 2.15.12) 15 KW (20 HP) and above, head above 120 mtr. |
| 193 | PHED BSR/2023-24/ Chapter-2/2.16/Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 194 | PHED BSR/2023-24/ Chapter-2/2.17/Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.2.17.1)Up to 5.00 HP |
| 195 | PHED BSR/2023-24/ Chapter-2/2.18/Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lightingarrangementetc. completesuitablefor threephasepumpset. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 196 | 2.18.1) Above5 HPand upto 10 HP |
| 197 | 2.18.2) Above 10 HP and up to 15 HP |
| 198 | 2.18.3) Above 15 HP and up to 20 HP |
| 199 | 2.18.4) Above 20 HP and up to 30 HP |
| 200 | PHED BSR/2023-24/Chapter-2/2.19/Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 201 | 2.19.1) 3 core 4.0 Sq.mm |
| 202 | 2.19.2) 3 core 6.0 Sq.mm |
| 203 | 2.19.3) 3 core 10.0 Sq.mm |
| 204 | 2.19.4) 3 core 16.0 Sq.mm |
| 205 | PHED BSR/2023-24/ Chapter-2/2.20/Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 206 | 2.20.1) 10.0 Sq.mm, 4 core |
| 207 | 2.20.2) 16.0 Sq.mm, 4 core |
| 208 | 2.20.3) 25.0 Sq.mm, 3.5 core |
| 209 | 2.20.4) 35.0 Sq.mm, 3.5 core |
| 210 | PHED BSR/2022-23/ Chapter-2/2.21/Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 211 | PHED BSR/2022-23/ Chapter-2/2.22/Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. |
| 212 | PHED BSR/2022-23/Chapter-2/2.23/Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 213 | 2.23.1) 125 mm dia |
| 214 | 2.23.2) 150 mm dia |
| 215 | 2.23.3) 200 mm dia |
| 216 | 2.23.4) 250 mm dia |
| 217 | PHED BSR/2023-24/ Chapter-2/2.24/Providing & Lowering in tube well ISI marked GI Pipe “B\" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 218 | 2.24.1) 32 mm dia |
| 219 | 2.24.2) 50 mm dia |
| 220 | 2.24.3) 65 mm dia |
| 221 | 2.24.4) 80 mm dia |
| 222 | PHED BSR/2023-24/Chapter-2/2.25/Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. |
| 223 | 2.25.1) 40 mm dia |
| 224 | 2.25.2) 50 mm dia |
| 225 | 2.25.3) 63 mm dia |
| 226 | 2.25.4) 75 mm dia |
| 227 | 2.25.5) 90 mm dia |
| 228 | PHED BSR/2023-24/ Chapter-2/2.26/Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. |
| 229 | 2.26.1) 50 mm dia |
| 230 | 2.26.2) 65 mm dia |
| 231 | 2.26.3) 80 mm dia |
| 232 | PHED BSR/2023-24/ Chapter-2/2.27/Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 233 | PHED BSR/2023-24/Chapter-2/2.28/Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15 mm dia CI quarter turn heavy duty Bib Cocks four nos. of superior quality and approved make, including interconnections complete job. |
| 234 | 2.28.1) 1000 litres capacity |
| 235 | 2.28.2) 2000 litres capacity |
| 236 | PHED BSR/2023-24/Chapter-2/2.29/Fabrication & Fixing M.S. Stand of specified class of angle iron Lshaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect. |
| 237 | PHED BSR/2022-23/ Chapter-2/2.30/Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes |
| 238 | 2.30.1) 65 mm dia |
| 239 | 2.30.2) 80 mm dia |
| 240 | PHED BSR/2023-24/ Chapter-2/2.31/Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe. |
| 241 | PHED BSR/2023-24/Chapter-2/2.32/Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover. |
| 242 | PHED BSR/2023-24/ 1.4 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 243 | HDPE PE-80PN-675 mm dia |
| 244 | 90 mm dia |
| 245 | PHED BSR/2023-24/Chapter-6/6.1/Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 246 | 6.1.1 - Manually Operated CI Sluice valve of Class PN-1.0 6.1.1.1 -80 mm HW |
| 247 | 6.1.1.2 - 100 mm HW |