Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-01-2025 | Extension of Bid Submission | Date | 31-01-2025 |
| 2 | 10-01-2025 | MODIFICATION OF SOME ITEMS IN BOQ AND TENDER DOCUMENT | Other | 24-01-2025 |
| 3 | 04-01-2025 | Extension of Date for Pre Bid Meeting | Date | 24-01-2025 |
| Sl. No. | Item Description |
| 1 | PART-A (Nagar Palika Parishad Bulandshahr water supply Reorganization schemeZone- 1) |
| 2 | Civil Work |
| 3 | Construction ofUNDER GROUND RESERVOIR,750 KLin M-30 grade of concrete. |
| 4 | Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 750 KL capacity awith main components, excluding cost of soil testing. |
| 5 | All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 |
| 6 | Minimum depth of foundation below original ground level will be 4.5M |
| 7 | Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) |
| 8 | The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 7 M.T.sqm. |
| 9 | Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. |
| 10 | Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. |
| 11 | Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 |
| 12 | C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. |
| 13 | Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . |
| 14 | Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. |
| 15 | Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works |
| 16 | Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). |
| 17 | Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. |
| 18 | Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 19 | Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). |
| 20 | Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. |
| 21 | Supply & laying of 80mm cement interlocking tiles for approach road including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 22 | Construction of 300x300mm size drain including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 23 | Laying of Rising Main pipe line & appurtenent works |
| 24 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 25 | Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete. |
| 26 | D.I. pipe Class-K-9 |
| 27 | 200 mm dia |
| 28 | 450 mm dia |
| 29 | Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 30 | D.I. pipe Class-K-9 |
| 31 | 200 mm dia |
| 32 | 450 mm dia |
| 33 | Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work. |
| 34 | C.I.D/F Sluice Valve IS 780-1984 |
| 35 | 450 mm dia |
| 36 | THRUST BLOCK |
| 37 | Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. |
| 38 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 39 | CC Road |
| 40 | Bituminous Road |
| 41 | Interlocking Road |
| 42 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 43 | CC Road |
| 44 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 45 | Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) |
| 46 | Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) |
| 47 | Sluice Valve Chamber (Masonary Type) |
| 48 | Laying of Distribution pipe line & other appurtenent works |
| 49 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 50 | Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. |
| 51 | HDPE Pipe (PE-100) |
| 52 | 110 mm dia |
| 53 | 140 mm dia |
| 54 | 160 mm dia |
| 55 | DI Pipe Class K-7 |
| 56 | 200 mm dia |
| 57 | 250 mm dia |
| 58 | 300 mm dia |
| 59 | Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 60 | HDPE Pipe (PE-100) |
| 61 | 110 mm dia |
| 62 | 140 mm dia |
| 63 | 160 mm dia |
| 64 | DI Pipe Class K-7 |
| 65 | 200 mm dia |
| 66 | 250 mm dia |
| 67 | 300 mm dia |
| 68 | Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. |
| 69 | (A) C. I. Sluice Valveas per latest IS specifications |
| 70 | 100 mm dia |
| 71 | 125 mm dia |
| 72 | 150 mm dia |
| 73 | 200 mm dia |
| 74 | 250 mm dia |
| 75 | Scour Valve 80 mm dia |
| 76 | Air Valve 20 mm dia |
| 77 | Fire Hydrants 80 mm dia |
| 78 | Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. |
| 79 | Sluice Valve Chamber (Masonary Type) |
| 80 | Sluice Valve Chamber (Surface Box Type) |
| 81 | Fire Hydrant Chambers |
| 82 | Air Valve Chambers |
| 83 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 84 | B.O.E. |
| 85 | C.C. Interlocking Tiles Road |
| 86 | C.C. Road |
| 87 | Bituminous Road |
| 88 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 89 | B.O.E Road (60% old and 40% new Bricks) |
| 90 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 91 | P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. |
| 92 | CC Road (100mm thickness of1:2:4 cement concrete ) |
| 93 | P.C.C. 1:4:8 in cement , course sand and 40mm thick stone ballast |
| 94 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 95 | Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. |
| 96 | (250 -350mm dia) upto 3.0 M |
| 97 | (90-100mm dia) upto 3.0 M |
| 98 | Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. |
| 99 | For 90 mm to 500mm dia (HDPE Pipe) |
| 100 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 101 | B.O.E. |
| 102 | C.C. Interlocking Tiles Road |
| 103 | C.C. Road |
| 104 | Bituminious Road |
| 105 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 106 | B.O.E Road (60% old and 40% new Bricks) |
| 107 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 108 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 109 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 110 | Maintenance works |
| 111 | Repairing of OHT 680KL/18 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. |
| 112 | Repairing of OHT 2200KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. |
| 113 | Repairs of Existing Pump House including Supply of all materials, labour, T&P, complete |
| 114 | Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. |
| 115 | Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete |
| 116 | E & M Work |
| 117 | E/M WORK OVER EXISTING TUBEWELL NO.1(SHAMSHAAN GHAT NEAR KALI NADI) AT ZONE- 1A |
| 118 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 119 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH (pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect. (suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 120 | Replacement of damaged control and power wiring due to shifting of all equipement from defucnt TW No. 20 to Shamshaan Ghat TW |
| 121 | Dismantling of existing pumping plant for installation of water level indicator. |
| 122 | Installation of existing pumping plant including commissioning & testing complete. |
| 123 | Shifting of all SCADA instruments from TW No. 20 to rebore TW Shamshaan Ghat near Kali Nadi |
| 124 | Restoration and repairing of old SCADA system equipement de-shifting on shamshaan ghat TW from TW No. 20 with all required materials complete in all respect. |
| 125 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 126 | E/M WORK OVER EXISTING TUBEWELL NO. 2 WATER WORKS CAMPUS (MAMAN CHOWKI ) |
| 127 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 128 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH (pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect. (suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 129 | Replacement of damaged control and power wiring of tubewell |
| 130 | Dismantling of existing pumping plant for installation of water level indicator. |
| 131 | Installation of existing pumping plant including commissioning & testing complete. |
| 132 | Restoration and repairing of old SCADA system equipement with all required materials complete in all respect. |
| 133 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 134 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANKUPARKOT 680 KL (ZONE 1A) |
| 135 | Motor operated Actuators with Sluice valve of size 250 mm. at distribution line. |
| 136 | CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia. |
| 137 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 138 | CE/UL Certified suitable capacity UPS with batteries. |
| 139 | CE & UL certified Radar type level transmitter for OHT |
| 140 | SITC Booster pump set 200 m3/hr & differential head 10mtincluding Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 100 m3/hr with 5.5 KW motor. (2w+1s) |
| 141 | TW Construction of 02 Nos. New & 01 No. Rebore for Zone - (1B+3A) |
| 142 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 143 | Transportation, Erection and Dismantling of Rig Machine |
| 144 | Drilling of 600mm size bore from GL to 60 BGL |
| 145 | Drilling of 500mm size bore from |
| 146 | (i) 60M BGL to 100MBGL |
| 147 | (ii) 100M BGL to 150MBGL |
| 148 | Tubewell Assembly |
| 149 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 150 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 151 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 152 | Supply of pea gravel |
| 153 | Logging of bore hole by departmental / approved electric logger. |
| 154 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 155 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 156 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 157 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 158 | Development of Tubewell by compressor |
| 159 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 160 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 161 | Development of Tubewell by O.P. Unit |
| 162 | Transportation, Installation and Dismantling of 3 Cusec O.P. Unit & Yield Test. |
| 163 | Development of Tubewell by 3 Cusec Capacity by O.P. Unit |
| 164 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 165 | E/M WORK OVER EXISTING TUBEWELL No.-1 (MACHLI BAZAR TW No. 28) & T.W.-2 ( RADHA NAGAR TW No. 30) AT ZONE-(1B+3A) |
| 166 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 167 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 168 | Replacement of damaged control and power wiring due to shifting of all equipement. |
| 169 | Dismantling of existing pumping plant for installation of water level indicator. |
| 170 | Installation of existing pumping plant including commissioning & testing complete. |
| 171 | Restoration and repairing of old SCADA system equipement with all required materials complete in all respect. |
| 172 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 173 | PUMPING PLANT OVER A REBORE TUBEWELL AT ZONE (1B+3A) TW-1 (MOHANKUTITW NO. 29) |
| 174 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1600 LPM, 30m head, 20 HPorsuitable capacity. |
| 175 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 176 | 01 KVAR UPS at TW Panel |
| 177 | 150 mm size motor operated actuator with Sluice valve |
| 178 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 179 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 180 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 181 | CE & UL certified pressure transmitter |
| 182 | CE & UL certified Surge protector for above control panel |
| 183 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 184 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 185 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 186 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 187 | Copper cable size 2x3cx4 sq mm. flat for 18 m extra column pipe. |
| 188 | SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. |
| 189 | PUMPING PLANT OVER ANEW TUBEWELL AT ZONE (1B+3A) TW-1 & 2 |
| 190 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1600 LPM, 30m head, 20 HPorsuitable capacity. |
| 191 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 192 | 01 KVAR UPS at TW Panel |
| 193 | 150 mm size motor operated actuator with Sluice valve |
| 194 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 195 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 196 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 197 | CE & UL certified pressure transmitter |
| 198 | CE & UL certified Surge protector for above control panel |
| 199 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 200 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 201 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 202 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 203 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 204 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 205 | SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. |
| 206 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK STAND ALONE AT MOHAN KUTI NEAR MAMAN CHOWKI 2200 KL ZONE (1B+3A) |
| 207 | Motor operated Actuators with Sluice valve of size 500 mm. at distribution line. |
| 208 | CE & UL certified Electomagnetic Flowmeter for OHT line size 500 mm. dia. |
| 209 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 210 | CE/UL Certified suitable capacity UPS with batteries. |
| 211 | CE & UL certified Radar type level transmitter for OHT |
| 212 | S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. |
| 213 | PumpSet at C.W.R: |
| 214 | Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3500 LPM, 36 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 50 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. |
| 215 | Soft starter 45 KW or suitable size as per site requirement. |
| 216 | Cast iron pipes & specials. |
| 217 | Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. |
| 218 | Sluice Valve : |
| 219 | DI Sluice Valve 200 mm with actuator |
| 220 | Reflex Valve |
| 221 | DI DF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: |
| 222 | 200 mm dia |
| 223 | 250 mm dia |
| 224 | DI Dismantling joints |
| 225 | 200 mm dia |
| 226 | 250 mm dia |
| 227 | Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. |
| 228 | Automatic Chlorinating Plant |
| 229 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 230 | CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia. |
| 231 | L.T. Panel BoardConforming to IEC-60439 |
| 232 | L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. |
| 233 | 02 No. incoming feeder from two Nos. Transformer with following details:- |
| 234 | 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. |
| 235 | One set of current transformer of ratio 400/5A |
| 236 | One No. CT operated ammeter 0-400A with ammeter |
| 237 | One No. Voltmeter 0-500 V with voltmeter |
| 238 | One No power factor meter 0.5 lag/ 1-0.5 lead |
| 239 | One No Surge arrestor Relay & One no. UV/OV Relay |
| 240 | One No frequency meter. |
| 241 | Total Nos. of Outgoing feeder as follows- |
| 242 | MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. |
| 243 | Ammeter with selector switch. |
| 244 | Single phasing preventer. |
| 245 | Sets of timer and relays for overload and underload. |
| 246 | 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. |
| 247 | 01 Nos. 63 Amps. MCCB as Misc. load |
| 248 | 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. |
| 249 | 01 No. required 30 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. |
| 250 | Power and control cables |
| 251 | 1100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) |
| 252 | Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. |
| 253 | EARTHING |
| 254 | Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. |
| 255 | Lighting system: |
| 256 | Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. |
| 257 | S/F of 72 watt LED with lumen reflector. |
| 258 | Feeder pillar for lighting |
| 259 | Supply and laying of 4x16mm2 Al. armoured cable. |
| 260 | Internal electrification with fixtures. |
| 261 | S/F 1200 mm ceilingFan for LT Room |
| 262 | S/F of exhaust Fan for LT Room, VCB room. |
| 263 | Earthing of street light pole (SOR-41) |
| 264 | Painting of street light (P5-634) |
| 265 | Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) |
| 266 | 12 mm thick rubber mating for safe working on. |
| 267 | Tools |
| 268 | Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 |
| 269 | Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well |
| 270 | Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\"x 12\", make- Taparia)Plier (250mm, make-Taparia) |
| 271 | Chain wrench (12\"x18\", make Taparia) Pipe wrench (1200mm, make Taparia) |
| 272 | Installation of above equipments ,Pumsets and Panels etc. complete. |
| 273 | Testing of pumping plantand Panels etc. complete at works |
| 274 | Commissioning of pumping plantsand Panels etc. complete |
| 275 | Chequered plate of required size so as to cover all trenches. |
| 276 | Power Distribution Transformer : |
| 277 | Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. |
| 278 | Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. |
| 279 | Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. |
| 280 | Installation , testing and Commissioning of Transformer complete. |
| 281 | H.T. Switch Gear Panel : |
| 282 | Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- |
| 283 | Incommer Feeder- 01 No. |
| 284 | 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. |
| 285 | Outgoing Feeder- 02 Nos. |
| 286 | outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. |
| 287 | DC Supply |
| 288 | SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. |
| 289 | Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. |
| 290 | S/F of XLPE cable End termination box |
| 291 | Indoor end termination box. |
| 292 | Earthing ofH.T Panel as per IS & IER. |
| 293 | Testing & Commissioning of HT Panel etc. |
| 294 | Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. |
| 295 | Commissioning of All sub station equipments etc. complete in all respect. |
| 296 | OTHER REQUIRED ITEMS |
| 297 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 298 | Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp |
| 299 | CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet |
| 300 | CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. |
| 301 | CE & UL certified Surge protector for control panel |
| 302 | CE & UL certified pressure transmitter for each pump |
| 303 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 304 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 305 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 306 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 307 | Complete cabling for ZPS including all power and control cable of all equipments at ZPS |
| 308 | Security Surveillance IP Camera with Recorer |
| 309 | Installation, commissioning & testing for CWR |
| 310 | S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE (1B+3A) |
| 311 | REBORE TUBEWELL No. - 1 (MOHANKUTITW NO. 29) ZONE (1B+3A) |
| 312 | Dismantling of existing pumping plant for installation of SCADA equipements. |
| 313 | Shifting of all SCADA instruments from Mohan Kuti TW to New Rebore TW |
| 314 | Restoration and repairing of old SCADA system equipement de-shifting on new rebore TW with all required materials complete in all respect. |
| 315 | Installation, commissioning & testing for one tubewell |
| 316 | Trial run for three month period for tubewell |
| 317 | NEW T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) ZONE (1B+3A) |
| 318 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 319 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 320 | Installation, commissioning & testing for one tubewell |
| 321 | Trial run for three month period for tubewell |
| 322 | COST OF INTEGRATION |
| 323 | Cost of integration of Tubewells, OHT & CWR with MCS/ LCS |
| 324 | S.I.T.C OF SCADA SYSTEM FOR EXISTING STAND ALONE OVERHEAD TANKUPARKOT 680 KL (ZONE 1A) |
| 325 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 326 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 327 | S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK STAND ALONE AT MOHAN KUTI NEAR MAMAN CHOWKI 2200 KL ZONE (1B+3A) |
| 328 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 329 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 330 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 1A |
| 331 | 03 Month trial & run of Pumping Plant for 02 Nos. existing tubewell & 01 no. booster pump including liquid Chlorine, Operating Staff. Excluding Electricity Charges. |
| 332 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE (1B+3A) |
| 333 | 03 Month trial & run of Pumping Plant for 01 No. new tubewell, 01 no rebore tubewell & 02 nos existing tubewell including Operating Staff. Excluding Electricity Charges. |
| 334 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR. |
| 335 | 03 Month trial & run of Pumping Plant for 01 No. new tubewell & CWR including liquid Chlorine, Operating Staff. Excluding Electricity Charges. |
| 336 | PART-B (Nagar Palika Parishad water supply Reorganization scheme Zone-02) |
| 337 | Civil Work |
| 338 | Construction ofRCC Overhead Tank of 2300 KL Capacity at 24 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete.(Zone-2B) |
| 339 | Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer\"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2300 KL capacity at 24 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 8 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 8 T/m2 as per testing report than the design of OHT shall be done at B.C 8 T/m2 and depth 2.50m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 340 & 341 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 339 (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). |
| 340 | Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar\"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. |
| 341 | Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe-500 mm dia;DMA -1 Outlet pipe-300mm diaDMA -2 Outlet pipe-300mm diaDMA -3 Outlet pipe-300mm diaDMA -4 Outlet pipe-450mm Over flow pipe -400 mm dia Wash out pipe-100 mm dia .The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. |
| 342 | Construction ofRCC Overhead Tank of 2200 KL Capacity at 24 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from nearby existing approach road level) in M-30 grade of concrete. (Zone-2C) |
| 343 | Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer\"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2200 KL capacity at 24 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as7 T/m2and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 8 T/m2 and depth 3.0m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 344 & 345 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 343. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). |
| 344 | Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar\"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. |
| 345 | Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe-400 mm dia;DMA -1 Outlet pipe-300mm diaDMA -2 Outlet pipe-350mm diaOver flow pipe -400 mm dia Wash out pipe-100 mm dia .t.The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work (till handing over and defect liability period of 12 months after handing over or date of shedule complision whichever is later) to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. |
| 346 | Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 800 KL capacity awith main components, excluding cost of soil testing. |
| 347 | All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 |
| 348 | Minimum depth of foundation below original ground level will be 4.5M |
| 349 | Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) |
| 350 | The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 8 M.T.sqm. |
| 351 | Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. |
| 352 | Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. |
| 353 | Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 |
| 354 | C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. |
| 355 | Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . |
| 356 | Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. |
| 357 | Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works |
| 358 | Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). |
| 359 | Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. |
| 360 | Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 361 | Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). |
| 362 | Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. |
| 363 | Supply & laying of 80mm cement interlocking tiles for approach road including 100 mm thick P.C.C. 1:6:12supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 364 | Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-C |
| 365 | Laying of Rising Main pipe line & appurtenent works |
| 366 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 367 | Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete |
| 368 | D.I. pipe Class-K-9 |
| 369 | 200 mm dia |
| 370 | 450 mm dia |
| 371 | Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 372 | D.I. pipe Class-K-9 |
| 373 | 200 mm dia |
| 374 | 450 mm dia |
| 375 | Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work |
| 376 | C.I.D/F Sluice Valve IS 780-1984 |
| 377 | 200 mm dia |
| 378 | 450 mm dia |
| 379 | THRUST BLOCK |
| 380 | Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. |
| 381 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 382 | B.O.E. Road |
| 383 | Bituminous Road |
| 384 | Interlocking Road |
| 385 | Cement Concrete Road |
| 386 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 387 | B.O.E Road (Using 60% old & 40% New) |
| 388 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 389 | Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) |
| 390 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 391 | Sluice Valve Chamber (Masonary Type) |
| 392 | Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) |
| 393 | Laying of Distribution pipe line & other appurtenent works |
| 394 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 395 | Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. |
| 396 | HDPE Pipe (PE-100) |
| 397 | 110 mm dia |
| 398 | 140 mm dia |
| 399 | 160 mm dia |
| 400 | DI Pipe Class K-7 |
| 401 | 200 mm dia |
| 402 | 250 mm dia |
| 403 | 300 mm dia |
| 404 | 350 mm dia |
| 405 | 400 mm dia |
| 406 | 450 mm dia |
| 407 | 500 mm dia |
| 408 | Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 409 | HDPE Pipe (PE-100) |
| 410 | 110 mm dia |
| 411 | 140 mm dia |
| 412 | 160 mm dia |
| 413 | DI Pipe Class K-7 |
| 414 | 200 mm dia |
| 415 | 250 mm dia |
| 416 | 300 mm dia |
| 417 | 350 mm dia |
| 418 | 400 mm dia |
| 419 | 450 mm dia |
| 420 | 500 mm dia |
| 421 | Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. |
| 422 | (A) C. I. Sluice Valveas per latest IS specifications |
| 423 | 100 mm dia |
| 424 | 125 mm dia |
| 425 | 150 mm dia |
| 426 | 200 mm dia |
| 427 | 250 mm dia |
| 428 | Scour Valve 80 mm dia |
| 429 | CI Single ball type Air Valve 20 mm dia |
| 430 | Fire Hydrants 80 mm dia |
| 431 | Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. |
| 432 | Sluice Valve Chamber (Masonary Type) |
| 433 | Sluice Valve Chamber (Surface Box Type) |
| 434 | Fire Hydrant Chambers |
| 435 | Air Valve Chambers |
| 436 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 437 | B.O.E. |
| 438 | C.C. Interlocking Tiles Road |
| 439 | C.C. Road |
| 440 | Bituminous Road |
| 441 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 442 | B.O.E Road (60% old and 40% new Bricks) |
| 443 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 444 | CC Road (100mm thickness of1:2:4 cement concrete ) over P.C.C. 1:4:8 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. |
| 445 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 446 | Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. |
| 447 | For up to 1.5 M wide |
| 448 | For up to 1.5 M to 3.0 M wide |
| 449 | For above 3.0 M wide |
| 450 | Making New Water House Connection with Distribution main excluding Dismantling & permanent reinstatement in all types of road but including supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. |
| 451 | For 90 mm to 500mm dia (HDPE Pipe/ DI ) |
| 452 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 453 | B.O.E. |
| 454 | C.C. Interlocking Tiles Road |
| 455 | C.C. Road |
| 456 | Bituminous Road |
| 457 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 458 | B.O.E Road (60% old and 40% new Bricks) |
| 459 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 460 | CC Road (100mm thickness of1:2:4 cement concrete ) over P.C.C. 1:4:8 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. |
| 461 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 462 | Maintenance works |
| 463 | Repairing of OHT 2000KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. |
| 464 | Repairs of Existing Pumphouse cum clorenating room Including Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. |
| 465 | Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. |
| 466 | Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete |
| 467 | E & M work |
| 468 | ZONE - 2A |
| 469 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2A, T.W.-1 ( AVAS VIKAS FIRST TW 31), & T.W.-2 ( AVAS VIKAS FIRST TW 32), |
| 470 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1500 LPM, 55m head, 30 HP |
| 471 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 472 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 473 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 474 | Replacement of damaged control and power wiring at tubewell of all equipement at pump house & OHT |
| 475 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 476 | Dismantling of existing pumping plant |
| 477 | Installation of above pumping plant including commissioning & testing complete. |
| 478 | Repairing and overholing of actuator including all labour etc. complete. |
| 479 | PUMPING PLANT OVER A EXISTNG TUBEWELL AT ZONE 2A, T.W.-3 (AVAS VIKAS OLD OHT CAMPUS REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW No. 11), |
| 480 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 2000 LPM, 55m head, 40 HP |
| 481 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 482 | 01 KVAR UPS at TW Panel |
| 483 | 150 mm size motor operated actuator with Sluice valve |
| 484 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 485 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 486 | CE & UL certified pressure transmitter |
| 487 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 488 | CE & UL certified Surge protector for above control panel |
| 489 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 490 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 491 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 492 | Dismantling of existing pumping plant |
| 493 | Installation of above pumping plant including commissioning & testing complete. |
| 494 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANKAWAS VIKAS 1st 2200 KL (ZONE 2A) |
| 495 | Repairing of Motor operated Actuators with Sluice valve of size 350 mm. at distribution line. |
| 496 | Repairing of CE & UL certified Electomagnetic Flowmeter for OHT line size 350 mm. dia. |
| 497 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 498 | CE/UL Certified suitable capacity UPS with batteries. |
| 499 | Zone-2B |
| 500 | New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine |
| 501 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 502 | Transportation, Erection and Dismantling of Rig Machine |
| 503 | Drilling of 600mm size bore from GL to 60 BGL |
| 504 | Drilling of 500mm size bore from |
| 505 | 60M BGL to 100MBGL |
| 506 | 100M BGL to 150MBGL |
| 507 | Tubewell Assembly |
| 508 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 509 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 510 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 511 | Supply of pea gravel |
| 512 | Logging of bore hole by departmental / approved electric logger. |
| 513 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 514 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 515 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 516 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 517 | Development of Tubewell by compressor |
| 518 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 519 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 520 | Development of Tubewell by O.P. Unit |
| 521 | Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. |
| 522 | Development of Tubewell by 2 Cusec Capacity by O.P. Unit |
| 523 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 524 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2B, TW No.-1(HARISHCHANDER NAGAR TW No. 10) & T.W.-2 ( BABUPURA TW No. 14) |
| 525 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 30m head, 15 HP |
| 526 | Soft starter with RS-485 port-400V Class15 Kw rating |
| 527 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 528 | Replacement of damaged control and power wiring at tubewell of all equipement at pump house & OHT |
| 529 | SITC of 03 Phase Servo Voltage Stabilizer 25 KVA. |
| 530 | Dismantling of existing pumping plant |
| 531 | Installation of above pumping plant including commissioning & testing complete. |
| 532 | Repairing and overholing of actuator including all labour etc. complete. |
| 533 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2B, TW No.3 (REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW DEVIPURA BANDH) |
| 534 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 30m head, 15 HP |
| 535 | Soft starter with RS-485 port-400V Class15 Kw rating |
| 536 | 01 KVAR UPS at TW Panel |
| 537 | 150 mm size motor operated actuator with Sluice valve |
| 538 | Capacitor Bank 10 KVAR with Relay |
| 539 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 540 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 541 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 542 | CE & UL certified pressure transmitter |
| 543 | CE & UL certified Surge protector for above control panel |
| 544 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 545 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 546 | Copper cable size 2x3cx4 sq mm. flat for 18 m extra column pipe. |
| 547 | SITC of 03 Phase Servo Voltage Stabilizer 20 KVA. |
| 548 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 2B, T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) |
| 549 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accessories with nut bolt ,rubber packing etc 2000 LPM, 30m head, 25 HP |
| 550 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 551 | 01 KVAR UPS at TW Panel |
| 552 | 150 mm size motor operated actuator with Sluice valve |
| 553 | Capacitor Bank 10 KVAR with Relay |
| 554 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 555 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 556 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 557 | CE & UL certified pressure transmitter |
| 558 | CE & UL certified Surge protector for above control panel |
| 559 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 560 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 561 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 562 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 563 | SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. |
| 564 | ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK AT LADIES THANA 2200 KL (ZONE 2B) |
| 565 | Motor operated Actuators with Sluice valve of size 500 mm. at distribution line. |
| 566 | CE & UL certified Electomagnetic Flowmeter for OHT line size 500 mm. dia. |
| 567 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 568 | CE/UL Certified suitable capacity UPS with batteries. |
| 569 | S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. |
| 570 | Pump Set at C.W.R: |
| 571 | Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 4000 LPM, 38 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 60 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. |
| 572 | Soft starter with RS-485 port-400V Class55 KW rating or above as per site requirement. |
| 573 | Cast iron pipes & specials. |
| 574 | Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. |
| 575 | Sluice Valve : |
| 576 | Sluice Valve 200 mm with actuator |
| 577 | Reflex Valve |
| 578 | CIDF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: |
| 579 | 200 mm dia |
| 580 | 300 mm dia |
| 581 | CI Dismantling joints |
| 582 | 200 mm dia |
| 583 | 300 mm dia |
| 584 | Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. |
| 585 | Automatic Chlorinating Plant |
| 586 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 587 | CE & UL certified Electomagnetic Flowmeter at common header size 300 mm. dia. |
| 588 | CE / UL approved Pressure Transmitter for each pump. |
| 589 | L.T. Panel BoardConforming to IEC-60439 |
| 590 | L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. |
| 591 | 02 No. incoming feeder from two Nos. Transformer with following details:- |
| 592 | 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. |
| 593 | One set of current transformer of ratio 400/5A |
| 594 | One No. CT operated ammeter 0-400A with ammeter |
| 595 | One No. Voltmeter 0-500 V with voltmeter |
| 596 | One No power factor meter 0.5 lag/ 1-0.5 lead |
| 597 | One No Surge arrestor Relay & One no. UV/OV Relay |
| 598 | One No frequency meter. |
| 599 | Total Nos. of Outgoing feeder as follows- |
| 600 | MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. |
| 601 | Ammeter with selector switch. |
| 602 | Single phasing preventer. |
| 603 | Sets of timer and relays for overload and underload. |
| 604 | 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. |
| 605 | 01 Nos. 63 Amps. MCCB as Misc. load |
| 606 | 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. |
| 607 | 01 No. required 40 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. |
| 608 | Power and control cables |
| 609 | 1100 V grade, 3 core 70mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) |
| 610 | Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. |
| 611 | EARTHING |
| 612 | Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. |
| 613 | Lighting system: |
| 614 | Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. |
| 615 | S/F of 72 watt LED with lumen reflector. |
| 616 | Feeder pillar for lighting |
| 617 | Supply and laying of 4x16mm2 Al. armoured cable. |
| 618 | Internal electrification with fixtures. |
| 619 | S/F 1200 mm ceilingFan for LT Room |
| 620 | S/F of exhaust Fan for LT Room, VCB room. |
| 621 | Earthing of street light pole (SOR-41) |
| 622 | Painting of street light (P5-634) |
| 623 | Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) |
| 624 | 12 mm thick rubber mating for safe working on. |
| 625 | Tools |
| 626 | Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 |
| 627 | Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well |
| 628 | Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\"x 12\", make- Taparia)Plier (250mm, make-Taparia) |
| 629 | Chain wrench (12\"x18\", make Taparia) Pipe wrench (1200mm, make Taparia) |
| 630 | Installation of above equipments ,Pumsets and Panels etc. complete. |
| 631 | Testing of pumping plantand Panels etc. complete at works |
| 632 | Commissioning of pumping plantsand Panels etc. complete |
| 633 | Chequered plate of required size so as to cover all trenches. |
| 634 | Power Distribution Transformer : |
| 635 | Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. |
| 636 | Supply and laying of 1100 voltage grade ,2x3.5Cx 95 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. |
| 637 | Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. |
| 638 | Installation , testing and Commissioning of Transformer complete. |
| 639 | H.T. Switch Gear Panel : |
| 640 | Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- |
| 641 | Incommer Feeder- 01 No. |
| 642 | 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. |
| 643 | Outgoing Feeder- 02 Nos. |
| 644 | outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. |
| 645 | DC Supply |
| 646 | SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. |
| 647 | Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. |
| 648 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 649 | Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp |
| 650 | CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet |
| 651 | CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. |
| 652 | CE & UL certified Surge protector for control panel |
| 653 | CE & UL certified pressure transmitter for each pump |
| 654 | Complete cabling for ZPS including all power and control cable of all equipments at ZPS |
| 655 | Security Surveillance IP Camera with Recorer |
| 656 | S/F of XLPE cable End termination box |
| 657 | Indoor end termination box. |
| 658 | Earthing ofH.T Panel as per IS & IER. |
| 659 | Testing & Commissioning of HT Panel etc. |
| 660 | Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. |
| 661 | Commissioning of All sub station equipments etc. complete in all respect. |
| 662 | Zone-2C |
| 663 | New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine |
| 664 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 665 | Transportation, Erection and Dismantling of Rig Machine |
| 666 | Drilling of 600mm size bore from GL to 60 BGL |
| 667 | Drilling of 500mm size bore from |
| 668 | 60M BGL to 100MBGL |
| 669 | 100M BGL to 150MBGL |
| 670 | Tubewell Assembly |
| 671 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 672 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 673 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 674 | Supply of pea gravel |
| 675 | Logging of bore hole by departmental / approved electric logger. |
| 676 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 677 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 678 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 679 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 680 | Development of Tubewell by compressor |
| 681 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 682 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 683 | Development of Tubewell by O.P. Unit |
| 684 | Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. |
| 685 | Development of Tubewell by 2 Cusec Capacity by O.P. Unit |
| 686 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 687 | PUMPING PLANT OVER A REBORE TUBEWELL AT ZONE-2C, T.W.-1 (Avas vikas TW 21) |
| 688 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 57m head, 40 HP |
| 689 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 690 | 01 KVAR UPS at TW Panel |
| 691 | 150 mm size motor operated actuator with Sluice valve |
| 692 | Capacitor Bank 10 KVAR with Relay |
| 693 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 694 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 695 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 696 | CE & UL certified pressure transmitter |
| 697 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 698 | CE & UL certified Surge protector for above control panel |
| 699 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 700 | Copper cable size 2x3cx10 sq mm. flat for 18 m extra column pipe. |
| 701 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx50 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 702 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 703 | SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. |
| 704 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 2C, T.W.-1 & 2 |
| 705 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 57m head, 40 HP |
| 706 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 707 | 01 KVAR UPS at TW Panel |
| 708 | 150 mm size motor operated actuator with Sluice valve |
| 709 | Capacitor Bank 10 KVAR with Relay |
| 710 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 711 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 712 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 713 | CE & UL certified pressure transmitter |
| 714 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 715 | CE & UL certified Surge protector for above control panel |
| 716 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 717 | Copper cable size 2x3cx10 sq mm. flat for 18 m extra column pipe. |
| 718 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx50 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 719 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 720 | SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. |
| 721 | ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK AT IPS 3 CAMPUS SHANTI NIKETAN2200 KL (ZONE - 2C) |
| 722 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line. |
| 723 | CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia. |
| 724 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too. |
| 725 | CE/UL Certified suitable capacity UPS with batteries. |
| 726 | SCADA SYSTEM FOR ALL TW OF ZONE-2 WITH CWR |
| 727 | (A) ZONE- 2A EXISTING TUBEWELL NO. T.W.-1 ( AVAS VIKAS FIRST TW 31), & T.W.-2 ( AVAS VIKAS FIRST TW 32), |
| 728 | Repairing & overholing of all existing scada automation related equipement including restatoration of existing RTU/PLC panels with all required material complete in all recpect. |
| 729 | (B) ZONE- 2A EXISTING T.W.No.-3 ( AVAS VIKAS OLD OHT CAMPUS REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW No. 11), |
| 730 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 731 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 732 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 733 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 734 | Installation, commissioning & testing for one tubewell |
| 735 | Trial run for three month period for tubewell |
| 736 | (A) ZONE- 2B EXISTING TUBEWELL NO. TW No.-1 (HARISHCHANDER NAGAR TW No. 10) & T.W.-2 ( BABUPURA TW No. 14) |
| 737 | Repairing & overholing of all existing scada automation related equipement including restatoration of existing RTU/PLC panels with all required material complete in all recpect. |
| 738 | (B) ZONE- 2B EXISTING TW No.3 (REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW DEVIPURA BANDH) |
| 739 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 740 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 741 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 742 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 743 | Installation, commissioning & testing for one tubewell |
| 744 | Trial run for three month period for tubewell |
| 745 | (C) ZONE- 2B NEW T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) |
| 746 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 747 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 748 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 749 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 750 | Installation, commissioning & testing for one tubewell |
| 751 | Trial run for three month period for tubewell |
| 752 | (A) ZONE- 2C REBORE TUBEWELL NO. 01(Avas vikas TW 21) |
| 753 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 754 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 755 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 756 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 757 | Installation, commissioning & testing for one tubewell |
| 758 | Trial run for three month period for tubewell |
| 759 | (B) ZONE- 2C NEW TUBEWELL 2 NOS. (TW NO. 1 & 2) |
| 760 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 761 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 762 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 763 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 764 | Installation, commissioning & testing for one tubewell |
| 765 | Trial run for three month period for tubewell |
| 766 | (C) COST OF INTEGRATION |
| 767 | Cost of integration of Tubewells and OHT with MCS/ LCS |
| 768 | S.I.T.C OF SCADA SYSTEM FOR C.W.R. HAVING 03 NO. PUMPS |
| 769 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 770 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 771 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 772 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 773 | Installation, commissioning & testing for CWR |
| 774 | S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK AWAS VIKAS 1st2200 KL AT (ZONE 2A) |
| 775 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 776 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 777 | Renovation / Restoration of SCADA at existing OHT |
| 778 | CE & UL certified Radar type level transmitter for OHT |
| 779 | S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT LADIES THANA 2200 KL AT 2200 KL (ZONE 2B) |
| 780 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 781 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 782 | CE & UL certified Radar type level transmitter for OHT |
| 783 | S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT IPS 3 CAMPUS SHANTI NIKETAN2200 KL (ZONE - 2C) |
| 784 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 785 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 786 | CE & UL certified Radar type level transmitter for OHT |
| 787 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 2A |
| 788 | 03 Month trial & run of Pumping Plant for 03 Nos. existing tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges. |
| 789 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 2B |
| 790 | 03 Month trial & run of Pumping Plant for 02 Nos. new tubewells & 02 nos. existing tubewells including Operating Staff. Excluding Electricity Charges. |
| 791 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR OF ZONE 2B |
| 792 | 03 Month trial & run of Pumping Plant for 01 No. CWR including liquid Chlorine & Operating Staff. Excluding Electricity Charges. |
| 793 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3C |
| 794 | 03 Month trial & run of Pumping Plant for 02 Nos. new tubewells & 01 no. rebore tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges. |
| 795 | PART-C (Nagar Palika Parishad water supply Reorganization scheme Zone-03) |
| 796 | Civil Work |
| 797 | Construction ofRCC Overhead Tank of 2400 KL Capacity at 26 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete.(Sub Zone-3c) |
| 798 | Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer\"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2400 KL capacity at 26 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 7 T/m2 and depth 2.50m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosedITEM 799 & 800 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 798. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). |
| 799 | Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar\"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. |
| 800 | Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe- 450 mm dia;DMA -1 Outlet pipe-400mm diaDMA -2 Outlet pipe-400mm diaOver flow pipe - 500 mm dia Wash out pipe-100 mm dia .The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. |
| 801 | Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 800 KL capacity awith main components, including cost of soil testing. |
| 802 | All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 |
| 803 | Minimum depth of foundation below original ground level will be 4.5M |
| 804 | Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) |
| 805 | The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 8 M.T.sqm. |
| 806 | Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. |
| 807 | Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. |
| 808 | Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 |
| 809 | C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. |
| 810 | Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . |
| 811 | Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. |
| 812 | Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works |
| 813 | Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). |
| 814 | Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. |
| 815 | Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 816 | Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). |
| 817 | Construction of 300 x 300 mm size drain inwater works compoundincluding supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge |
| 818 | Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. |
| 819 | Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-C |
| 820 | Supply & laying of 80mm cement interlocking tiles for approach road including 100 mm thick P.C.C. 1:6:12supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 821 | Laying of Rising Main pipe line & appurtenent works |
| 822 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 823 | Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete. |
| 824 | D.I. pipe Class-K-9 |
| 825 | 200 mm dia |
| 826 | 450 mm dia |
| 827 | Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 828 | D.I. pipe Class-K-9 |
| 829 | 200 mm dia |
| 830 | 450 mm dia |
| 831 | Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work. |
| 832 | C.I.D/F Sluice Valve IS 780-1984 |
| 833 | 200 mm dia |
| 834 | 450 mm dia |
| 835 | THRUST BLOCK |
| 836 | Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. |
| 837 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 838 | Bituminous Road |
| 839 | Interlocking Road |
| 840 | Cement Concrete Road |
| 841 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 842 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 843 | Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) |
| 844 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 845 | Sluice Valve Chamber (Masonary Type) |
| 846 | Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) |
| 847 | Laying of Distribution pipe line & other appurtenent works |
| 848 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 849 | Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. |
| 850 | HDPE Pipe (PE-100) |
| 851 | 110 mm dia |
| 852 | 140 mm dia |
| 853 | 160 mm dia |
| 854 | DI Pipe Class K-7 |
| 855 | 200 mm dia |
| 856 | 250 mm dia |
| 857 | 300 mm dia |
| 858 | 350 mm dia |
| 859 | 400 mm dia |
| 860 | Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. |
| 861 | HDPE Pipe (PE-100) |
| 862 | 110 mm dia |
| 863 | 140 mm dia |
| 864 | 160 mm dia |
| 865 | DI Pipe Class K-7 |
| 866 | 200 mm dia |
| 867 | 250 mm dia |
| 868 | 300 mm dia |
| 869 | 350 mm dia |
| 870 | 400 mm dia |
| 871 | Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. |
| 872 | (A) C. I. Sluice Valveas per latest IS specifications |
| 873 | 100 mm dia |
| 874 | 125 mm dia |
| 875 | 150 mm dia |
| 876 | 200 mm dia |
| 877 | 250 mm dia |
| 878 | Scour Valve 80 mm dia |
| 879 | CI Single ball type Air Valve 20 mm dia |
| 880 | Fire Hydrants 80 mm dia |
| 881 | Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. |
| 882 | Sluice Valve Chamber (Masonary Type) |
| 883 | Sluice Valve Chamber (Surface Box Type) |
| 884 | Fire Hydrant Chambers |
| 885 | Air Valve Chambers |
| 886 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 887 | B.O.E. |
| 888 | C.C. Interlocking Tiles Road |
| 889 | C.C. Road |
| 890 | Bituminous Road |
| 891 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 892 | B.O.E Road (60% old and 40% new Bricks) |
| 893 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 894 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 895 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 896 | Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. |
| 897 | For up to 1.5 M wide |
| 898 | For up to 1.5 M to 3.0 M wide |
| 899 | For above 3.0 M wide |
| 900 | Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. |
| 901 | For 90 mm to 500mm dia (HDPE Pipe/ DI ) |
| 902 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 903 | B.O.E. |
| 904 | C.C. Interlocking Tiles Road |
| 905 | C.C. Road |
| 906 | Bituminous Road |
| 907 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 908 | B.O.E Road (60% old and 40% new Bricks) |
| 909 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 910 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 911 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 912 | Maintenance works |
| 913 | Repairing of OHT 2250KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. |
| 914 | Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. |
| 915 | Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete in all respect. |
| 916 | E & M work |
| 917 | Zone 3 |
| 918 | Zone-3B |
| 919 | New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine |
| 920 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 921 | Transportation, Erection and Dismantling of Rig Machine |
| 922 | Drilling of 600mm size bore from GL to 60 BGL |
| 923 | Drilling of 500mm size bore from |
| 924 | 60M BGL to 100MBGL |
| 925 | 100M BGL to 150MBGL |
| 926 | Tubewell Assembly |
| 927 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 928 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 929 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 930 | Supply of pea gravel |
| 931 | Logging of bore hole by departmental / approved electric logger. |
| 932 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 933 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 934 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 935 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 936 | Development of Tubewell by compressor |
| 937 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 938 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 939 | Development of Tubewell by O.P. Unit |
| 940 | Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. |
| 941 | Development of Tubewell by 2 Cusec Capacity by O.P. Unit |
| 942 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 943 | PUMPING PLANT OVER AEXISTING (REBORE) TUBEWELL N0.-1 AT ZONE-3B(SHIVPURI) TUBEWELL CONSTRUCTED BY NAGAR PALIKA PARISHAD, BULANDSHAHR AND TO BE COMMISSIONED BY THEM |
| 944 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 945 | 01 KVAR UPS at TW Panel |
| 946 | 150 mm size motor operated actuator with Sluice valve |
| 947 | Capacitor Bank suitable capacity KVAR with Relay |
| 948 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 949 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 950 | CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. |
| 951 | CE & UL certified pressure transmitter |
| 952 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 953 | CE & UL certified Surge protector for above control panel |
| 954 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 955 | Complete cabling of tubewell including all power and control cables of all equipment at pump house. |
| 956 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 957 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 958 | SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. |
| 959 | Dismantling of existing pumping plant |
| 960 | Installation of above pumping plant including commissioning & testing complete. |
| 961 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 3B T.W.-1 & 2 |
| 962 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 55m head, 40 HP orsuitable capacity. |
| 963 | Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. |
| 964 | 01 KVAR UPS at TW Panel |
| 965 | 150 mm size motor operated actuator with Sluice valve |
| 966 | Capacitor Bank suitable capacity KVAR with Relay |
| 967 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 968 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 969 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 970 | CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. |
| 971 | CE & UL certified pressure transmitter |
| 972 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 973 | CE & UL certified Surge protector for above control panel |
| 974 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 975 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 976 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 977 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 978 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 979 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 980 | SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. |
| 981 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2250 KL (ZONE 3B) |
| 982 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3B |
| 983 | CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3B |
| 984 | Motor operated Actuators with Sluice valve of size 350 mm. at distribution line of DMA-2 ofsub zone 3B |
| 985 | CE & UL certified Electomagnetic Flowmeter of size 350 mm of DMA-2 ofsub zone 3B |
| 986 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 |
| 987 | CE/UL Certified suitable capacity UPS with batteries. |
| 988 | CE & UL certified Radar type level transmitter for OHT |
| 989 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2200 KL OFSUB ZONE (1B+3A) FOR(ZONE-1) |
| 990 | Sub Zone 1B OF SUB(1B+3A) FOR ZONE -1 |
| 991 | Motor operated Actuators with Sluice valve of size 300 mm. at distribution line of DMA-1 ofsub zone 1B |
| 992 | CE & UL certified Electomagnetic Flowmeter of size 300 mm of DMA-1 ofsub zone 1B |
| 993 | Sub Zone 3A OF SUB(1B+3A) FOR ZONE -1 |
| 994 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3A |
| 995 | CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3A |
| 996 | Motor operated Actuators with Sluice valve of size 300 mm. at distribution line of DMA-2 ofsub zone 3A |
| 997 | CE & UL certified Electomagnetic Flowmeter of size 300 mm of DMA-2 ofsub zone 3A |
| 998 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 |
| 999 | Zone-3C |
| 1000 | New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine |
| 1001 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 1002 | Transportation, Erection and Dismantling of Rig Machine |
| 1003 | Drilling of 600mm size bore from GL to 60 BGL |
| 1004 | Drilling of 500mm size bore from |
| 1005 | 60M BGL to 100MBGL |
| 1006 | 100M BGL to 150MBGL |
| 1007 | Tubewell Assembly |
| 1008 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 1009 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 1010 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 1011 | Supply of pea gravel |
| 1012 | Logging of bore hole by departmental / approved electric logger. |
| 1013 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 1014 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 1015 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 1016 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 1017 | Development of Tubewell by compressor |
| 1018 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 1019 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 1020 | Development of Tubewell by O.P. Unit |
| 1021 | Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. |
| 1022 | Development of Tubewell by 2 Cusec Capacity by O.P. Unit |
| 1023 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 1024 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE - 3C TW-1 (CWR CAMPUS) & 2, 3 , 4 |
| 1025 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1900 LPM, 29m head, 20 HP orsuitable capacity. |
| 1026 | Soft starter with RS-485 port-400V Class15 Kw rating or above as per site requirement. |
| 1027 | 01 KVAR UPS at TW Panel |
| 1028 | 150 mm size motor operated actuator with Sluice valve |
| 1029 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1030 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 1031 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1032 | CE & UL certified pressure transmitter |
| 1033 | CE & UL certified Surge protector for above control panel |
| 1034 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 1035 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 1036 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 1037 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 1038 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 1039 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 1040 | SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. |
| 1041 | ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK 2200 KL (ZONE 3C ) |
| 1042 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3C |
| 1043 | CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3C |
| 1044 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-2 ofsub zone 3C |
| 1045 | CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-2 ofsub zone 3C |
| 1046 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 |
| 1047 | CE/UL Certified suitable capacity UPS with batteries. |
| 1048 | CE & UL certified Radar type level transmitter for OHT |
| 1049 | S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. |
| 1050 | PumpSet at C.W.R: |
| 1051 | Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3700 LPM, 40 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 60 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. |
| 1052 | Soft starter with RS-485 port-400V Class55 KW rating or above as per site requirement. |
| 1053 | Cast iron pipes & specials. |
| 1054 | Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. |
| 1055 | Sluice Valve : |
| 1056 | DI Sluice Valve 200 mm with actuator |
| 1057 | Reflex Valve |
| 1058 | DI DF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: |
| 1059 | 200 mm dia |
| 1060 | 250 mm dia |
| 1061 | DI Dismantling joints |
| 1062 | 200 mm dia |
| 1063 | 250 mm dia |
| 1064 | Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. |
| 1065 | Automatic Chlorinating Plant |
| 1066 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1067 | CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia. |
| 1068 | L.T. Panel BoardConforming to IEC-60439 |
| 1069 | L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. |
| 1070 | 02 No. incoming feeder from two Nos. Transformer with following details:- |
| 1071 | 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. |
| 1072 | One set of current transformer of ratio 400/5A |
| 1073 | One No. CT operated ammeter 0-400A with ammeter |
| 1074 | One No. Voltmeter 0-500 V with voltmeter |
| 1075 | One No power factor meter 0.5 lag/ 1-0.5 lead |
| 1076 | One No Surge arrestor Relay & One no. UV/OV Relay |
| 1077 | One No frequency meter. |
| 1078 | Total Nos. of Outgoing feeder as follows- |
| 1079 | MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. |
| 1080 | Ammeter with selector switch. |
| 1081 | Single phasing preventer. |
| 1082 | Sets of timer and relays for overload and underload. |
| 1083 | 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. |
| 1084 | 01 Nos. 63 Amps. MCCB as Misc. load |
| 1085 | 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. |
| 1086 | 01 No. required 30 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. |
| 1087 | Power and control cables |
| 1088 | 1100 V grade, 3 core 70mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) |
| 1089 | Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. |
| 1090 | EARTHING |
| 1091 | Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. |
| 1092 | Lighting system: |
| 1093 | Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. |
| 1094 | S/F of 72 watt LED with lumen reflector. |
| 1095 | Feeder pillar for lighting |
| 1096 | Supply and laying of 4x16mm2 Al. armoured cable. |
| 1097 | Internal electrification with fixtures. |
| 1098 | S/F 1200 mm ceilingFan for LT Room |
| 1099 | S/F of exhaust Fan for LT Room, VCB room. |
| 1100 | Earthing of street light pole (SOR-41) |
| 1101 | Painting of street light (P5-634) |
| 1102 | Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) |
| 1103 | 12 mm thick rubber mating for safe working on. |
| 1104 | Tools |
| 1105 | Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 |
| 1106 | Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well |
| 1107 | Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6\"x 12\", make- Taparia)Plier (250mm, make-Taparia) |
| 1108 | Chain wrench (12\"x18\", make Taparia) Pipe wrench (1200mm, make Taparia) |
| 1109 | Installation of above equipments ,Pumsets and Panels etc. complete. |
| 1110 | Testing of pumping plantand Panels etc. complete at works |
| 1111 | Commissioning of pumping plantsand Panels etc. complete |
| 1112 | Chequered plate of required size so as to cover all trenches. |
| 1113 | Power Distribution Transformer : |
| 1114 | Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. |
| 1115 | Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. |
| 1116 | Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. |
| 1117 | Installation , testing and Commissioning of Transformer complete. |
| 1118 | H.T. Switch Gear Panel : |
| 1119 | Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- |
| 1120 | Incommer Feeder- 01 No. |
| 1121 | 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. |
| 1122 | Outgoing Feeder- 02 Nos. |
| 1123 | outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. |
| 1124 | DC Supply |
| 1125 | SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. |
| 1126 | Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. |
| 1127 | S/F of XLPE cable End termination box |
| 1128 | Indoor end termination box. |
| 1129 | Earthing ofH.T Panel as per IS & IER. |
| 1130 | Testing & Commissioning of HT Panel etc. |
| 1131 | Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. |
| 1132 | Commissioning of All sub station equipments etc. complete in all respect. |
| 1133 | OTHER REQUIRED ITEMS |
| 1134 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 1135 | Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp |
| 1136 | CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet |
| 1137 | CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. |
| 1138 | CE & UL certified Surge protector for control panel |
| 1139 | CE & UL certified pressure transmitter for each pump |
| 1140 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1141 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1142 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 1143 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 1144 | Complete cabling for ZPS including all power and control cable of all equipments at ZPS |
| 1145 | Security Surveillance IP Camera with Recorer |
| 1146 | Installation, commissioning & testing for CWR |
| 1147 | All SCADA SYSTEM ON TW ZONE 3B& 3C |
| 1148 | S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE 3B |
| 1149 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1150 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1151 | Installation, commissioning & testing for tubewell |
| 1152 | Trial run for three month period for tubewell |
| 1153 | NEW TUBEWELL AT ZONE-3B T.W.-1 & 2 |
| 1154 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1155 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1156 | Installation, commissioning & testing for tubewell |
| 1157 | Trial run for three month period for tubewell |
| 1158 | S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE 3 C TW-1 (CWR CAMPUS) & 2, 3 , 4 |
| 1159 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1160 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1161 | Installation, commissioning & testing for tubewell |
| 1162 | Trial run for three month period for tubewell |
| 1163 | COST OF INTEGRATION |
| 1164 | Cost of integration of Tubewells, OHT & CWR with MCS/ LCS |
| 1165 | All SCADA SYSTEM ON OHT ZONE 3B& 3C |
| 1166 | S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK 2250 KL AT (ZONE 3B) |
| 1167 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 1168 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 1169 | Renovation / Restoration of SCADA at existing OHT |
| 1170 | S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT 2200 KL (ZONE 3C) |
| 1171 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 1172 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 1173 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3B |
| 1174 | 03 Month trial & run of Pumping Plant for 01 Nos. existing tubewell & 02 nos. new tubewells including liquid Chlorine, Operating Staff. Excluding Electricity Charges. |
| 1175 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3C |
| 1176 | 03 Month trial & run of Pumping Plant for 03 Nos. new tubewells including Operating Staff. Excluding Electricity Charges. |
| 1177 | 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR. |
| 1178 | 03 Month trial & run of Pumping Plant for 01 No. CWR including liquid Chlorine & 01 no. new tubewell, Operating Staff. Excluding Electricity Charges. |
| 1179 | PART - D (Nagar Palika Parisad Bulandshahr Reorganization Scheme Zone 5) |
| 1180 | CIVIL WORK |
| 1181 | Construction ofRCC Overhead Tank of 1900 KL Capacity at 20 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete. |
| 1182 | Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer\"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 1900 KL capacity at 20 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 7 T/m2 and depth 3.0m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 1183 & 1184 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 1182. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). |
| 1183 | Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar\"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. |
| 1184 | Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-400 mm dia in inlet;DMA 1- 400 mm dia in outlet; DMA 2- 400 mm dia in outletDMA 3- 250 mm dia in outlet, 100 mm dia in wash out.The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height.Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. |
| 1185 | Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works |
| 1186 | Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). |
| 1187 | Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. |
| 1188 | Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 1189 | Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). |
| 1190 | Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. |
| 1191 | Supply & laying of 80mm cement interlocking tiles for approach road including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. |
| 1192 | Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-Charge. |
| 1193 | Laying of Rising Main pipe line & appurtenent works |
| 1194 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 1195 | Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete |
| 1196 | D.I. pipe Class-K-9 |
| 1197 | 200 mm dia |
| 1198 | Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 1199 | D.I. pipe Class-K-9 |
| 1200 | 200 mm dia |
| 1201 | Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work |
| 1202 | C.I.D/F Sluice Valve IS 780-1984 |
| 1203 | 200 mm dia |
| 1204 | THRUST BLOCK |
| 1205 | Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. |
| 1206 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 1207 | Cement Concrete Road |
| 1208 | Bituminous Road |
| 1209 | Interlocking Road |
| 1210 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 1211 | Cement concrete Road (100mm thickness of 1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 1212 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 1213 | Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) |
| 1214 | Sluice Valve Chamber (Masonary Type) |
| 1215 | Laying of Distribution pipe line & other appurtenent works |
| 1216 | Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 1217 | Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. |
| 1218 | HDPE Pipe (PE-100) |
| 1219 | 110 mm dia |
| 1220 | 140 mm dia |
| 1221 | 160 mm dia |
| 1222 | DI Pipe Class K-7 |
| 1223 | 200 mm dia |
| 1224 | 250 mm dia |
| 1225 | 300 mm dia |
| 1226 | 400 mm dia |
| 1227 | Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work |
| 1228 | HDPE Pipe (PE-100) |
| 1229 | 110 mm dia |
| 1230 | 140 mm dia |
| 1231 | 160 mm dia |
| 1232 | DI Pipe Class K-7 |
| 1233 | 200 mm dia |
| 1234 | 250 mm dia |
| 1235 | 300 mm dia |
| 1236 | 400 mm dia |
| 1237 | Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. |
| 1238 | (A) C. I. Sluice Valveas per latest IS specifications |
| 1239 | 100 mm dia |
| 1240 | 125 mm dia |
| 1241 | 150 mm dia |
| 1242 | 200 mm dia |
| 1243 | 250 mm dia |
| 1244 | Scour Valve 80 mm dia |
| 1245 | Air Valve 20 mm dia |
| 1246 | Fire Hydrants 80 mm dia |
| 1247 | Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. |
| 1248 | Sluice Valve Chamber (Masonary Type) |
| 1249 | Sluice Valve Chamber (Surface Box Type) |
| 1250 | Fire Hydrant Chambers |
| 1251 | Air Valve Chambers |
| 1252 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 1253 | B.O.E. |
| 1254 | C.C. Interlocking Tiles Road |
| 1255 | C.C. Road |
| 1256 | Bituminous Road |
| 1257 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 1258 | B.O.E Road (60% old and 40% new Bricks) |
| 1259 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 1260 | CC Road (100mm thickness of1:2:4 cement concrete ) |
| 1261 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 1262 | Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. |
| 1263 | (100 -40mm dia) upto 3.0 M |
| 1264 | (90-100mm dia) upto 3.0 M |
| 1265 | Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. |
| 1266 | For 90 mm to 500mm dia (HDPE Pipe/DI) |
| 1267 | Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. |
| 1268 | B.O.E. |
| 1269 | C.C. Interlocking Tiles Road |
| 1270 | C.C. Road |
| 1271 | Bituminous Road |
| 1272 | Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. |
| 1273 | B.O.E Road (60% old and 40% new Bricks) |
| 1274 | Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. |
| 1275 | Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) |
| 1276 | Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) |
| 1277 | Maintenance works |
| 1278 | Repairing of OHT 2200KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. |
| 1279 | Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. |
| 1280 | Interconnection in existing distribution main with supply of all materials,specials,labour,t7p including dismantling and reinstatement of all types of road ect complete in all respect. |
| 1281 | E & M work |
| 1282 | Construction of Tubewell for Zone - 5A & 5B |
| 1283 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. |
| 1284 | Transportation, Erection and Dismantling of Rig Machine |
| 1285 | Drilling of 600mm size bore from GL to 60 BGL |
| 1286 | Drilling of 500mm size bore from |
| 1287 | (i) 60M BGL to 100MBGL |
| 1288 | (ii) 100M BGL to 150MBGL |
| 1289 | Tubewell Assembly |
| 1290 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 1291 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 1292 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 1293 | Supply of pea gravel |
| 1294 | Logging of bore hole by departmental / approved electric logger. |
| 1295 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 1296 | Lowering of 300mm dia pipe from GL to 54m deep BGL. |
| 1297 | Lowering of 200mm dia pipe from 54 to 100m deep BGL. |
| 1298 | Lowering of 200mm dia pipe from 100 to 135m deep BGL. |
| 1299 | Development of Tubewell by compressor |
| 1300 | Transportation, Installation and Dismantling of 250 PSI Compressor |
| 1301 | Development of Tubewell by 250 PSI Capacity Air compressor |
| 1302 | Development of Tubewell by O.P. Unit |
| 1303 | Transportation, Installation and Dismantling of 3 Cusec O.P. Unit & Yield Test. |
| 1304 | Development of Tubewell by 3 Cusec Capacity by O.P. Unit |
| 1305 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 1306 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-5A, T.W.-1 (CHANDPUR TW NO. 24 OHT CAMPUS) & T.W.-2 (NEAR FCI GODOWN TW NO. 27) |
| 1307 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 55m head, 25 HP orsuitable capacity. |
| 1308 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 1309 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1310 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1311 | Replacement of damaged control and power wiring at tubewell of all equipment at pump house. |
| 1312 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1313 | SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. |
| 1314 | Dismantling of existing pumping plant |
| 1315 | Repairing & overholing of actuator including all labour etc complete. |
| 1316 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 5A, T.W.-1 |
| 1317 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 55m head, 25 HP orsuitable capacity. |
| 1318 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 1319 | 01 KVAR UPS at TW Panel |
| 1320 | 150 mm size motor operated actuator with Sluice valve |
| 1321 | Capacitor Bank 10 KVAR with Relay |
| 1322 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1323 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 1324 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1325 | CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. |
| 1326 | CE & UL certified pressure transmitter |
| 1327 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1328 | CE & UL certified Surge protector for above control panel |
| 1329 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 1330 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 1331 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 1332 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 1333 | SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. |
| 1334 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE 5B, T.W.-1 (AMBA ENCLAVE) |
| 1335 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1400 LPM, 53m head, 30 HP orsuitable capacity. |
| 1336 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 1337 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1338 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1339 | Replacement of damaged control and power wiring at tubewell of all equipment at pump house. |
| 1340 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1341 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 1342 | Dismantling of existing pumping plant |
| 1343 | Repairing & overholing of actuator including all labour etc complete. |
| 1344 | PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE 5B, T.W.-2 MANSAROVAR COLONY (TW CONSTRUCTED BY NAGAR PALIKA PARISHAD BSR) |
| 1345 | SITC of Submersible Pumping Plant with 24m column pipe assembly, NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1400 LPM, 53m head, 30 HP orsuitable capacity. |
| 1346 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 1347 | 01 KVAR UPS at TW Panel |
| 1348 | 150 mm size motor operated actuator with Sluice valve |
| 1349 | Capacitor Bank 10 KVAR with Relay |
| 1350 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1351 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 1352 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1353 | CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. |
| 1354 | CE & UL certified pressure transmitter |
| 1355 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1356 | CE & UL certified Surge protector for above control panel |
| 1357 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 1358 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 1359 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 1360 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 1361 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 1362 | PUMPING PLANT OVER A NEW TUBEWELL AT ZONE-5B, T.W.-1 (PROPOSED OHT CAMPUS) |
| 1363 | SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1500 LPM, 53m head, 30 HP orsuitable capacity. |
| 1364 | Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. |
| 1365 | 01 KVAR UPS at TW Panel |
| 1366 | 150 mm size motor operated actuator with Sluice valve |
| 1367 | Capacitor Bank 10 KVAR with Relay |
| 1368 | 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. |
| 1369 | CE/UL approved manufacturer\"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. |
| 1370 | CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. |
| 1371 | CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. |
| 1372 | CE & UL certified pressure transmitter |
| 1373 | SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 1374 | CE & UL certified Surge protector for above control panel |
| 1375 | Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) |
| 1376 | Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . |
| 1377 | Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. |
| 1378 | Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. |
| 1379 | SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. |
| 1380 | ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2200 KL (ZONE 5A) |
| 1381 | Repairing and Overhauling of Motor operated Actuators with Sluice valve of size 300 mm. at distribution line with all required material complete in all respect at DMA-1 |
| 1382 | Repairing and Overhauling of CE & UL certified Electomagnetic Flowmeter for OHT line size 300 mm. dia. with all required material complete in all respect at DMA-1 |
| 1383 | Motor operated Actuators with Sluice valve of size 300 mm. at distribution line with all required material complete in all respect at DMA-2 |
| 1384 | CE & UL certified Electomagnetic Flowmeter for OHT line size 300 mm. dia. with all required material complete in all respect at DMA-2 |
| 1385 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 1386 | CE/UL Certified suitable capacity UPS with batteries . |
| 1387 | ELECTRICAL / MECHANICAL WORK FOR NEW OVERHEAD TANK 1900 KL (ZONE 5B) |
| 1388 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution lineat DMA-1 |
| 1389 | CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia at DMA-1 |
| 1390 | Motor operated Actuators with Sluice valve of size 400 mm. at distribution line at DMA-2 |
| 1391 | CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia at DMA-2 |
| 1392 | Motor operated Actuators with Sluice valve of size 250 mm. at distribution line at DMA-3 |
| 1393 | CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia at DMA-3 |
| 1394 | Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. |
| 1395 | CE/UL Certified suitable capacity UPS with batteries . |
| 1396 | SITC OF SCADA SYSTEM FOR ZONE- 5A EXISTING T.W.-1 (CHANDPUR TW NO. 24 OHT CAMPUS) & T.W.-2 (NEAR FCI GODOWN TW NO. 27) |
| 1397 | Repairing & overhauling of all existing scada automation related equipement including restoration of existing RTU / PLC panel with all required material coplete in all respect. |
| 1398 | ZONE- 5A NEW TW NO. 1 |
| 1399 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1400 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1401 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 1402 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 1403 | Installation, commissioning & testing for tubewell |
| 1404 | Trial run for three month period for tubewell |
| 1405 | SITC OF SCADA SYSTEM FOR ZONE- 5B EXISTING T.W.-1 (AMBA ENCLAVE) |
| 1406 | Repairing & overhauling of all existing scada automation related equipement including restoration of existing RTU / PLC panel with all required material coplete in all respect. |
| 1407 | ZONE- 5B EXISTING T.W.-2 MANSAROVAR COLONY (TW CONSTRUCTED BY NAGAR PALIKA PARISHAD BSR) |
| 1408 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1409 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1410 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 1411 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 1412 | Installation, commissioning & testing for tubewell |
| 1413 | Trial run for three month period for tubewell |
| 1414 | ZONE- 5B NEW TUBEWELL No. 1 (PROPOSED OHT CAMPUS) |
| 1415 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. |
| 1416 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. |
| 1417 | CE & UL certified 7\" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. |
| 1418 | Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) |
| 1419 | Installation, commissioning & testing for tubewell |
| 1420 | Trial run for three month period for tubewell |
| 1421 | COST OF INTEGRATION |
| 1422 | Cost of integration of Tubewells and OHT with MCS/ LCS |
| 1423 | S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANKAT (ZONE 5A) |
| 1424 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 1425 | Renovation / Restoration of SCADA at existing OHT |
| 1426 | CE & UL certified Radar type level transmitter for OHT |
| 1427 | S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANKAT (ZONE 5B) |
| 1428 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 1429 | G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . |
| 1430 | CE & UL certified Radar type level transmitter for OHT |
| 1431 | 03 MONTH TRAIL & RUN OF PUMPING PLANT (Zone 5A & 5B) |
| 1432 | 03 Month trail & run of Pumping Plant for 06 Nos. tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy