| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 3 | Supplying and laying in the specified pattern of interlocking concrete block pavements(ICBP) with concrete blocks (with concrete grade as specified as per table 1 of IS 15658 : 2006) manufactured from BIS license manufacturer, with spacer nib (small protruding profiles on the vertical face of a paver block used as device for keeping minimum joint gap in between the paving blocks, as per Cl. No 3.26 of IS: 1568) and specified size and shape with aspect ratio the ratio of length t othickness of a paver block, as per cl.no.3.3 of IS: 15658) as per table 2 of IS: 1568 with flexural strength/breaking load as per annexure g of IS:1568, on the prepared base as certified CBR as per table 1 of IRC SP 63 2018 or else as of 25-35 mm thick (grading of the building sand as per clause 6.5.1 of IRC SP-63) paver block with joint filling sand and completing the edges with cut blocks as perCL.No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap.60 mm thicki) Color Decorative |
| 4 | Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in-Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compactedand curing the morter joints for atleast 3 days including cost and carriage of all materials complete. |
| 5 | Supplying and layingcement Concrete channel 300x300x100 mm as per drawing of m 25 Grade ready mix concrete on 150 mm thick foundation of ordinary M 15 grade concrete having 50 mm projection beyond the channel (One side) complete as per Direction of EIC. |
| 6 | Cement concrete with graded jhama khoa (30 mm size) excluding shutteringIn ground floor and foundation.(a) 1:3:6 proportion |
| 7 | Supplying and stacking of good earth (adequate forhorticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) |
| 8 | Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%). |
| 9 | Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart . |
| 10 | Supplying and Planting of different plant / trees ( Supplyingwell grown plants bushy and healthy, minimum height asspecified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.ii) Rangon chineese / kamini of size not less than 20cm |
| 11 | vi) Duranta healthy plant of big size |
| 12 | xiv) Acalypha species ( Red/Green) of height 30cm-90cm inearthen pots of size 25cm. |
| 13 | xxiv) Hibiscus Rosa Sinensis of height 60 cm to 75 cm inearthen pots of size 35 cm. |
| 14 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as perdirection of Engineer in charge |
| 15 | Supplying of10 Sqmm, 4 Core XLPEinsulated Aluminium conductor armoured cables of 1.1KV grade as per IS 7098 (Part.1) 1988 Size: 10 Sqmm, 4 Core |
| 16 | Laying of one No. cable upto 35 Sqmm. In underground trench 460mm wide x 760mm average depth. With brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. Cable Size: 10 Sq.mm , 4 core |
| 17 | Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985(Dia) [PE - 63]A. 6 Kg / Sq.Cm. (Working Pressure)Dia - 50mm |
| 18 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring or dust & moisture-proof entry of XLPE/PVC armoured cables.Size: 10 sqmm, 4 core. |
| 19 | Finishing the end of following XLPE/PVCarmoured cables by crimping method including supplying and fixing solderless socket (Dowels make), taps, anticorrosive paste & jointing materilas.i) 4 core, 10 Sqmm. |
| 20 | Supplying & Erection of medium size feeder pillar box of Size (1200 x 750 x 450 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C |
| 21 | Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and direction of E.I.C.b) For medium size feeder pillar box. |
| 22 | Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages(a) Solid GI wire(iv) No. 10 SWG |
| 23 | Supplying and fixing 240/415V MCB of Breaking Capacity 10KA & C characteristics on din rail of existing DBs and necessary connection.6-32A (SP), Make: Legrand/seimens/Schneider |
| 24 | Supplying and drawing 1.1KV Single Core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required from terminal box at Bottom end to the respective LED fittings.1.b) 3 x 22/0.3(1.5 sqmm.) |
| 25 | Supply and fixing of greenline V2 street light (115 watt) complete with all accessories to be fixed/ projected from the wall of the building or on pole incl. making holes/providingClamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI- Medium) quality 1.5 mts. Average length having suitable bend S&F necy. length 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending gooddamages to wall incl. painting etcMake:- Crompton, 120 watt. |
| 26 | Supply & fixing M.S. loop box (10 SWG) of size 269 x 219 x 125mm having almirah type cover complete with special type locking arrangement including supply & fixing 200mm x 150mm x 6mm backlite sheet 1 No. 4-way ebonite connector block. 1 No. 15 Amp fuse unit (BPC/Juvas/ Havells make) fitted inside the box and suitable size danger board riveted on cover of the box outside & fixing the box with pole by means of M.S.Clamps of 25mm x 6mm of suitable length and encasing the box by 1:2:4 cement concrete with graded stone chip (19mm down). The depth of the concrete should be 60cm x 45cm x 45cm including Plasteringand neat cementing and supply & fixing 2Nos compression gland of suitable size and making all necessary connection as required. |
| 27 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars 415V 200A X 50 X 5 mm |
| 28 | Supplying and fixing 240/415V MCB of Breaking Capacity 10KA & C characteristics on din rail of existing DBs and necessary connection63A(FP)Make: Legrand/seimens/SchneiderRef: PWD(Elec.) sch 2017, Pg.D-6, Item-7Make: Legrand/seimens/SchneiderRef: PWD(Elec.) sch 2017, Pg.D-6, Item-7 |
| 29 | Supply and fixing of 240/230 volt, 50 Hz, T.P., powercontactor (Make: L & T/ABB/Schneider/Simence/ GE) havingcontact block of the following range.g) 50-85Amp |
| 30 | Supply and delivery of Electronic Timer suitable for 240/ 360/ 415V, 50 Hz(Make: L&T/ABB/Schneider/Simence/GE/Minilic) of the following time (Second) range:b) 12.0 to 120.0 |
| 31 | Supplying and drawing 1.1KV Single Core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection at Feeder piller box.1.o) 4 x 80/0.4 (10 sqm) |
| 32 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the groundlevel as below:(a) By ISI-Medium GI pipe |
| 33 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Soft Soil |
| 34 | Construction of foundation of existing pole below G.L. having Each 1171.00of dimension of 0.6 x 0.6 x 0.6 mtr (2’x 2’x2’) with graded stone chips (19mm down) in cement concrete proportion of 6:3:1 after necessary excavation including scraping . |
| 35 | Supply and fixing of Town Glow Post Top IP66/IK10 Post Top lantern with symmetric Light distribution complete with all accessories to be fixed on suitable pole incl. bolts and nuts incl. making drilled holes etc. to fixing up the landscape lighting pole complete.Make:- Philips, 50 Watt./ Crompton, 45 watt. |
| 36 | Supplying of LED lamps (40 W)Make:- Philips, 40.0 Watt, Base B22/E27, 4000 Lm |
| 37 | Add GST@18% on Sl. No. 1 to 33 |
| 38 | Add labour cess @1% on Sl. No. 1 to 34 |