| Sl. No. | Item Description |
| 1 | B-44/1.8 Earth work in excavation by mechanical means ( Hydraulic excavator) /manual meansin foundation trenches or drains(not exceeding 1.5m in width or 10sqm in plan) including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter.All kinds of soil. |
| 2 | B-54/3.1.6 Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth level1:4:8 (1Cement :4 Course Sand :8Graded stone aggregate 40 mm nominal size |
| 3 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand)(B/5.1.2) |
| 4 | B-65/5.2.2 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 5 | B-54/3.1.1Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). |
| 6 | B-55/3.2.1 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). |
| 7 | B-55/3.2.2 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). |
| 8 | B-61/ 4.10.3 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : (b)Columns, pillars, posts and struts etc. |
| 9 | B-56/3.8 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : |
| 10 | B-98/9.1Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | B-98/9.2 Structural steel work riveted, bolted orwelded in built up sections, trusses and framed work , including cutting, hoisting (height up to 10 m), fixing In position and applying a priming coat of approved steel primer all complete: |
| 12 | B-99/9.8P&F steel gate grating and grills made of angles tees square bars or other flats black pipe with holdfast and fittings complete as per design and drawing incl. cutting welding and fabrication with priming coat of red oxide |
| 13 | B-103/9.33+9.35 Add or deduct for each wire line over basic item Extra for using galvanized barbed wire instead of black barbed wire. Mtr. |
| 14 | B-139/12.3.2Plaster on new surface on walls in Cement Sand Mortar 1:6 incl. Racking of joint etc. complete fine finished 20mm thick |
| 15 | B-139/12.3.3Plaster on new surface on walls in Cement Sand Mortar 1:6 incl. Racking of joint etc. complete fine finished 12 mm thick |
| 16 | B-144/12.35.1 Colour washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a base coat of white washing with lime. |
| 17 | B-145/12.42Finishing walls with Acrylic smooth exterior paint of required shade including all scaffolding New work(Twoor more coat applied @ 1.67ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10sqm) |
| 18 | S-247/3.16.4 P&F rigid PVC pipe (IS 4985 mark) class IInd /4 Kg P.SqCM ) approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant 110mm dia |
| 19 | B-146/12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work |
| 20 | B-62/4.13.3Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermomechanically treated bars (As per relevent IS Code ) |
| 21 | B-66/5.7.3Half brick masonry in foundation & plinth using bricks ofdesignation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 22 | B-66/5.8.3Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 23 | B-99/9.9Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design). |
| 24 | B-48/1.25 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. |
| 25 | B-128/11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.40mmthickwith20mmthicknominalsizeaggregate. |
| 26 | B-56/ 3.7.1Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of waterproofcompound complete as per specification : 50 mm thick |
| 27 | B-93/8.13.2.1 Providing and fixing external grade board solid core single/ Double leaf flush door shutters IS: 2202 (Part-II)1996 marked using Phenolformal dehyderesin in glue both sides with approved stainless steelfittings complete as per annexure \"A\" :Commercial Veneer both side.30 MM |
| 28 | B-90/8.4.2.3 Providing and fixing fully panelled/partly panelled/double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\" and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :30 mm thick Shesham wood grade I |
| 29 | B-59/4.3 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 30 | B-61/4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 31 | B-61/4.10.2 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 32 | B-72/6.17.3 Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone 25 to 30mm thick. |
| 33 | B-132/11.18.2 Kota stone slab flooring 25 mm thick over 20 mm (average) thick baselaid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :slab area up to 2001 to 5000 Sq.Cm. ( B-60 / 11.18.2 ) |
| 34 | B-132/11.19.1 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3coarse sand) and jointed with grey cement slurry mixed with pigmentto match the shade of the slabs, including rubbing and polishingcomplete :slab up 1 to 2000Sq. Cm |
| 35 | B-131/11.17.3 Chequered precast cement concrete tiles 22 mm thick in footpath &courtyard jointed with neat cement slurry mixed with pigment to matchthe shade of tiles including rubbing and cleaning etc. complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) :.Dark shade using ordinary cement. |
| 36 | B-109/10.24 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 37 | B-101/9.19.3 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :(a)Windows side hung /Ventilators top or centre hung (openable) |
| 38 | B-102/9.26 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 39 | B-102/9.27 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 40 | B-100/ 9.13Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 27.5cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design. (Clear openable area to be measured for payment). |
| 41 | B-98/9.5 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 42 | B-107/10.17.1 Grading roof for water proofing treatment with water proofing compound : Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 43 | B-143/12.34.1 White washing with lime to give an even shade including all scaffolding: New work (three or more coats) |
| 44 | B-55/3.3.1 Providing and fixing upto floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1: 3 (1 cement : 3 coarsesand) cost of required centering, shuttering and finishing smooth with6 mm thick cement plaster 1: 3 (1 cement : 3 fine sand) on exposedsurface, including all T & P, curing etc. complete :M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 45 | B-109/10.24 Providing & laying broken glazed titles on roof (broken glazed tiles not less than 9 Kg/Sqm.) on top of hot bitumen @ 1.7 Kg/Sqm. [1.40Kg of VG-40 (30/40) grade and 0.30 Kg/Sqm. Of VG-10 (80/100)]grade and joints filled with cement mortar 1:2 (1 cement : 2 marble dustmixed with water proofing compund all complete as per direction ofEngineer-in-Charge. |
| 46 | B-50/1.35.3 Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameterholes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarsesand) to match the existing floor. With Chlorpyriphos/Lindane E.C.20% with 1% concentration. |
| 47 | S-217/1.2.2 P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : 580x440 mm. |
| 48 | S-221/1.36.3 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 550mm x 400mm |
| 49 | S-223/1.45.1P & F Looking Mirrors with P.V.C. frame of approved makeas per direction of Engineer-in-charge Size 500x400mm |
| 50 | S-223/1.47.4 P&F towel rail or ring of approved quality /make: C.P. brass towel rail with brackets 600x20 mm |
| 51 | S-240/2.37.2(a)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one stepCPVC solvent cement and testing of joints complete as per direction ofEngineer-in-Charge. (Internal work Exposed on wall) :20 mm dia nominal bore. |
| 52 | (b) ____do_____25 mm dia nominal bore. S-240/2.37.3 |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings, this included jointing of pipes & fittingswith one step CPVC solvent cement, trenching refilling & testing ofjoints complete as per direction of Engineer-in-Charge. (External work) :(a) 20 mm dia nominal bore.(S-240/2.39.2) |
| 54 | ____do____(b) 25 mm dia nominal bore. (S-240/2.39.3) |
| 55 | Making connection of G.I. distribution branch with G.I. main including all fitting.Up to 25 mm dia (S-235/2.3.1 ) |
| 56 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (a) C.P. Brass bib cock, 15 mm nominal bore. (S-232/2.7.3) |
| 57 | (b) -do- Long body, 15 mm nominal bore weight not less than 690 gm.B628 (S-232/2.7.4) |
| 58 | P & F Stop cock (IS:8931 Mark) superior quality & of approved make :(a) C.P. Brass 15 mm nominal bore. (S-232/2.8.4) |
| 59 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia S-256/3.44.2 |
| 60 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make single Tee with Door 110 mm dia S-258/3.45.17(ii) |
| 61 | _____do____Vent Cowel 110mmS-259/3.45.30 |
| 62 | _____do____Door Bend S-257/3.45.6(II) |
| 63 | _____do____Pipe ClipS-258/3.45.12(II) |
| 64 | _____do____Nahni Trap without Jali 4\"S-259/3.45.26 |
| 65 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 75mm dia S-256/3.44.1 |
| 66 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.(S-18 /2.33 )500 (liters capacity). |
| 67 | P & F Full-way valve(IS:778 Mark) or wheel valve of approved make :( S-233 /2.15.1 )(A) Gun-metal 15mm nominal bore |
| 68 | (B)Gun-metal 25mm nominal bore (S-233 /2.15.3) |
| 69 | P & F Flush Cock/Flush Valve (IS:9758 Mark) or WC of approved quality make C.P. brass Half-turn exposed 25 mm nominal bore. : .(S-233/2.14.7) |
| 70 | P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts up to length 450 mm. (S-233/2.13.3) |
| 71 | P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete :Brass wt. Not less than 300 gm,15mm.. (S-232/2.11.1) |
| 72 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40 mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete as per Rajasthan P.W.D. specifications : (Width W=Diameter of pipe in Cm+40 Cm.)(Excluding cost of pipe).100mm dia S.W. pipe (S-243/3.2.1) |
| 73 | Construction of manhole in all type of soil inner size 90 X 60Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cementconcrete 1:5:10 in foundation, 20 mm thick inside plaster inCM 1:6, finished with floating neat cement, 50mm thick M-15grade C.C. flooring, making channels, 80mm thick stone slabcovering with 40mm thick M-15 grade C.C. flooring, Cementcover with frame of 450mm dia, earthwork etc. complete asper design including disposal of surplus earth within 50 mtr.lead. Depth up to 0.5 M (S-250/3.19.1) |
| 74 | Construction of chamber in all type of soil with 300 mm thickmasonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mmthick insider plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, earthwork etc. complete as perdesign including disposal of surplus earth within a lead of 50 mtr.Inside size 300 × 300 mm depth upto 0.5 M Cement cover with frame.(S-251/3.21.1) |
| 75 | S-224/1.48.1 P & F Grating of approved quality/make :Stainless Steel Sheet size 125mm dia. |
| 76 | (S-252/3.22.1) Construction of Soakage well in all type of soil 300 mm thick dry masonry ,top and bottom 300 mm course in CSM 1:6,80 mm thick stone slab, jointing of slab in CM 1:3.Ralthal,Kharanja,40 mm thick M-15 grade C.C. flooring, earth work complete as per approved including disposal of earth with in a lead 50 mtr.Size 300 Cm. dia. Outside &300 Cm depth |
| 77 | (S-253/3.27.1) Construction of septic Tank in all types of soil with 40 Cm.thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nosstone foot rests of approved design ,two No. 450 mm dia eachFerro cement cover with frame, earth work etc. complete asper approved drawing including disposal of surplus earthwithin a lead of 50 mtr:- Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/cbothways including shuttering complete in all respect |
| 78 | (S-225/1.54.1) P & F Shower arm 15mm dia of approved quality/make. 1.54.1 C.P.brass heavy & superior quality 150mm Projection |
| 79 | P & F Inlet Connection (Angle Valves) Superior quality, ofapproved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked (S-233/2.12.1) |
| 80 | (S-225/1.54.1)P&F Shower arm 15mm dia of approved quality/ make.C.P. brass heavy & superior quality 150mm projection. |
| 81 | S-221/1.38.1P & F Kitchen & Lab. Sink of approved make with C.I.brackets duly painted, 40 mm C.P. waste coupling, C.P. Brasschain with rubber plug, 40 mm G.I. waste pipe up-to floorlevel complete including cutting and making good the wall &floor :Fire clay glazed kitchen sink (I.S 771-1985 Marked) size 600x 450 x 250mm |
| 82 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand)(B/12.5) |
| 83 | R-10.4(I) /A1 Direction and Place Identification signs with size more than 0.9 sqm size board.Retro-reflectorised Traffic Signs.Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape of required shade and colour.Supported and welded on 47 mm x 47mm of 12 SWG Squaretube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Specification upto 0.9 sqm size board |
| 84 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexiblecopper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot DippedGalvanizedModularBoxwithearthterminal,10AModular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3wayconnector,screws, makingconnections,testingetc.asrequired. Forspecificationofcopper Conductor, PhenolicLaminatedsheet\"s& Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additionaltechnicalparametersofproduct/workreferAnnexure\"A\" attached with thisShort point (up to 3 mtr.)Code--1.1.1 |
| 85 | Medium Point Code-1.1.2 |
| 86 | Long PointCode-1.1.3 |
| 87 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copperearthconductor1.1kVgrade(IS:694) in recessedISImarked MMS(IS:9537P -III )PVC conduit&it\"sISI marked(IS:3419- 1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc.asrequired. Forspecificationofcopper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.On board.Code-1.3.1 |
| 88 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexistingsurfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure \"A\" attached with this BSR2 x 2.5 Sqm.Code-4.1.6 |
| 89 | 2 x 4.0 Sq.mmCode-4.1.11 |
| 90 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III)PVCconduitalongwith ISImarked(IS:3419-1988)accessoriesas required in recess including cuttingthewall,coveringconduitand making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR -25mm Code-1.4.2 |
| 91 | Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Code-7.36 |
| 92 | Providing& FixingofISImarkedsurfacetype buzzer(IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All asperpreapprovedbyEngineerincharge. Foradditionaltechnical parametersofproducts/work ,refer Annexure\"A\"attachedwiththis Code-7.24 |
| 93 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR1170mm(+/-10%) LED batten with min. lumen output 2200 lm Code-17.1.1 |
| 94 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . LED Street Light fixture with Minimum lumen output 7500 lm. Code-18.12.4 |
| 95 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Code-5.9 |
| 96 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) Code-15.7.3 |
| 97 | Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I.Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR.20 mm Dia. Code-18.18.1 |
| 98 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.6 A to 32 A rating Code-6.1.1.2 |
| 99 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947- III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Double pole isolator. 63 A rating. Code-6.2.1.2 |
| 100 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Metal door (single phase) IK-09 and IP-43 with Metal end box. 8 Way (8+2) Code-6.10.1.3 |
| 101 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR.15 Watt Code-17.9.4 |
| 102 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR. Code-7.12 |
| 103 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Code-7.13 |
| 104 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam freelid suitablefor safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensureto enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Code-14.2 |
| 105 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .10 SWG G.I. ( Hot Dipped ) Wire. Code-14.6.9 |