| 1 | Tentulikhunti T/W |
| 2 | Labour charges for drilling of perfectly vertical bore of 200 mm dia T/W byramming upto 450 mm dia in all type of soil from 0 to 30 mtrs.using bentonite drilling mud & labour charges forlowering of T/W assembly pipes including Well Plug & stanner pipe ,and gravel packing by the side of T/W casing etc.development of the T/W by the Air Compressorto yield sand free water complete. The cost include the cost of pilot bore and transportation of all materials i.e hand boring set. Diesel pump & accessories & digging of mud pit etc.but excluding the cost of casing pipes,,cone& gravel etc .as per direction of site Engineer in charge. |
| 3 | Labour charges for slotting of 200mm dia PVC Pipe |
| 4 | Cost of 200mm dia PVC blank pipe (sch-80) |
| 5 | Cost of 200mm dia PVC cone |
| 6 | Cost of 200mm dia PVC threaded end cap. |
| 7 | Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality including cost of gravel& Transportation from Athagarh Quarries etc all complete as per the direction of the Engineer-in-charge. |
| 8 | Cost, supplying of 200X80mm dia M.S.T/W Cap with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 9 | Earth work in hard soil for excavation of foundation including dressing and levlling the bed and depositing the soil within 50 mtr. initial lead and 1.5 mtr. initial lift as per direction of Engineer-in-charge. |
| 10 | Filling in foundation and plinth with sand wellwatered and rammed including cost of sand as per direction of Engineer-in-charge. |
| 11 | C.C(1:4:8) with 4 Cm. size H.B.G metal laying and hoistingetc. complete with curing as per direction of Engineer-in-charge |
| 12 | Cement concrete (1:2:4) for R.C.C. works with 12mm size h.g.b. chips including hoisting and laying etc. complete with curing as per direction of Engineer-in-charge |
| 13 | Providing & supplyingof M.S.Rod forfor M.S. Reinforcement for R.C.C work including cutting, bending, binding & tying the grills & placing in position including cost of binding wire etc.complete as per direction of Engineer-in-charge |
| 14 | Rigidsmooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete etc. completeforColumn baseetc |
| 15 | Rigidsmooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete etc. completefor Slab,Column,Beam etc. |
| 16 | Brick work with Fly ash bricks of(23cm x 11 cm x 8 cm )in cement mortar (1:6) in foundation and plinth with curingetc.complete as per direction of Engineer-in-charge. |
| 17 | Brick work with Fly ash bricks of size (23cm x 11 cm x 8 cm ) having crushing strength not less than 75kg./cm2 with dimensional tolerance+ 8% in cement mortar (1:6)inSuperstructurewith curingetc.complete as per direction of Engineer-in-charge. |
| 18 | 12 mm thick cement plastering with cement mortar(1:6)over brick work with curing etc.complete.as per direction of Engineer-in-charge. |
| 19 | Cement Punning over thecement plasteringwith curing etc.complete.as per direction of Engineer-in-charge. |
| 20 | Filling F & P with excavated materials, earth, moorum including watering and ramming as directed by the Engineer-in-charge. |
| 21 | 2.5 cm Artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips etc. complete with curing as per direction of Engineer-in-charge |
| 22 | Wall painting 2 coats with plastic emulsion paint of approved shade on new workto give an even shade over a coat of Primer & two coats of White washingincluding cost of paint,Primer & shell limeetc. completeas per direction of Engineer-in-charge |
| 23 | Providing ,fitting & fixingof shutter plate with 18SWG MS Sheetconfirming to IS No.6248/7framed with32mmx32mm angle ironchowkhat of following size and includingall costs,taxes etccomplete with priming & paintingas per satisfaction of Engineer-in-Charge.Window= (0.90x0.90) sq.mtr & Door=(0.90x1.80)Sqm |
| 24 | Providing electrificaton to the Pump chamber by wiring the room with required item of materials including cost ofmaterial,labour,T& P etc. complete as per direction of Engineer-in-charge. |
| 25 | Construction of Display Board with 45mm dia steel pipes 2nos with a height of 1.50mtr over the ground level having couping depth of 0.60mtrwith a width of 1mtr jointed with MS plate of size 1.00mtrx0.75mtr and painting,lettering the detail salient featuresof project over the plate having radium back ground etc. complete as per direction of Engineer-in-Charge |
| 26 | Cost of Installation lowering of Submerssible pump set, delivery fitting ,electrical installation & energisation & water trial etc.withLabour Charges for cutting, threading of G.I.Pipe, cost of cosumable materials such asNut & Bolt , Rubber Insertion,white lead paint etc. including transportation charges of T&P materials like Chain Pully Block, Tripod pipes, Chain Toungeetc. complete as per direction ofsite Engineer in-charge. . |
| 27 | Supplythe hard copy & soft copy of 3 stage Photographs of the projectandpreparation of Handing over Documents of Panipanchayat etc.completeas perdirection of site Engineer in charge. |
| 28 | Earthwork in excavation of foundation in all kind of soil with initial lead andlift including rough dressing and levelling the bed and depositing the excavated materials within initial lead at nearby the worksite for reuse including breaking clods and stacking rubble for spreading and leveling as the case may be etc complete as per direction of the Engineer-in-charge. (Excavation by mechanical means 60% & manually 40%) |
| 29 | Back Filling the Pipe line trenches with excavated materials in layers not exceeding 0.30m including breaking clods within initial lead including leveling the tranches as the case may be etc complete as per direction of the Engineer-in-charge. |
| 30 | Conveyance of 160 mm outer dia High Density Polythylene Pipes of specified material grade & pressure ratingfrom Factory outlet to working site andSupplying all materials, labour, T&P forjointing of 200 mm outer dia High Density Polythylene Pipes by butt fusion welding method as per speciication & laying in tranches including testing including all cost etc complete as per direction of the Engineer-in-charge |
| 31 | Cost, Supplying of ISI marked 160mm Ø High Density Polythelene (HDPE) PipesPE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST |
| 32 | 5 HP/3.75 KW Energy efficiency Submersible pumpset of total head 25 mtr having 500 LPM discharge of reputed brand with BEE 3 Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamps & 30 mtr of 4.00 sqmm flat cable andImpeller of Bronze grade LTB-2 of IS 318/1981 confirming to IS specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 33 | Automatic Star Delta starter sheet steel enclosure suitable for operation of squirrel cage Induction motor upto 10HP (8-13) with 16. Amp (AC-3) contactor at 415 volt +6%-15%, 3 phase, 50 Hz, AC supply with suitable overload relay & No volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 volt |
| 34 | 32 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company with utilisation capacity cagegory AC- 22 of approved brand ofISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 35 | 3KVAR Power ShuntCapacitor with ISI mark of of reputed approved brand ofISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 36 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098 (Pt-II) of approved brand ofISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 37 | 80mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 38 | 80mm dia G.I.Bend ( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 39 | 80mm dia G.I.Flange(Medium Duty)conforming to IS No-6392/1971 with ISI mark of reputed company including all cost, conveyance, cess etc complete but excluding cost of GST |
| 40 | 80mm dia G.I.Socket(Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 41 | 80mm dia G.I.Nipple( Medium Duty) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 42 | Cost, supplying of M.ST/W Clamp (Pair) 100mm dia with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 43 | Cost, Supplying of ISI marked 160X160X160 mm HDPE Tee spigot design 6 kg |
| 44 | 160mm slipon Flange HDPE |
| 45 | Cost, Supplying of ISI marked160 MM HDPE Tail piece 160 mm long |
| 46 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 47 | Cost, Supplying of ISI marked160 MM HDPE End Cap |
| 48 | Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9Mtrlong PSC Pole(IS: 1678-1998) with 55mm² AAA Conductor,11 KV \"V\" Cross arm(10.2 k.g. each), with required No.of 11 KV T & C Disc. Insulators 70KN in tension point &11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc.with a cut point including cost of all materials, labour transportation,inspection & commissioning etc. complete. |
| 49 | Construction anderection of 11 /0.4 KV ,25 KVA Double Pole mounted Substationwith BIS Energy Level-II transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel (9.2 kg/mtr), Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle(4.5 kg/mtr),, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 6 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for25KVA S/S, G.I.pipe earthingwith 25X5mm G.I.Flatsincluding cost of 25 KVA 11/0.4 K.V. 3 star rated Transformer , 35 Sqmm 3 ½ Core PVC Cable - 40 mtr, couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc., including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning. |
| 50 | Construction of 3 phase 4 wire Line using 8mtr long 200 kgPSC Poles with LT XLPE AB Cable of (3X35 mmSq.+ 1X25mm sq.) along with all required materials and concreting of stay/poles LT Dead end clamp, suspension clamp with I - hook, stay accessories such as Wire Insulators, clamp etc.to completepower supply as per the field condition (40m Span length) |
| 51 | Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavationof earth pits2 Nos of size 1200mm X1200mm X 3000mm for fixing of earthing pipe2 Nos of size 30mm dia X 3000 mm length with required slotting in pipes & fittings with 30 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required4mm2/2.5mm2PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge. |
| 52 | Construction ofBoundary wallof (3.60mx 3.0 )Sq.mtraround the sub station by providing4no of 35cmx35cm pillarsand restwalling withbrick masonary having proper foundation as per the drawingincluding Sand filling and metal spreading inside the boundary , Fixing of MSgrill gate of size 1.5mx1.5mwith 35x35x6mm angles and 25x6mm flatsetc. as per direction of Engineer-in-charge. |
| 53 | (i) Earthwork in excavation in hard soil within initial lead & lift includingdressing and levelling the bed etc. complete. |
| 54 | (ii) Filling of sand in foundation and plinthwell watered and rammed |
| 55 | (iii) C.C (1:4:8) using 4cm H.G metal |
| 56 | (iv) Brick work withFly ashbricks in CM (1:6) in F&P including cost, conveyance & Royaltyetc. |
| 57 | (v) C.C. (1:2:4) using 12mm HG chips at Plinth |
| 58 | (vi) 12mm thick C.P in C.M (1:6)over brick work with racking of joints |
| 59 | (vii) Filling the foundation and plinth with excavated materials |
| 60 | (viii) Cost of MS Gatewith 35x35x6 mm Angle & 25 x6 mm Flatincluding priming & Paintingetc complete |
| 61 | (ix) Metal Spreading inside the boundary |