|
| 1 | Earth work in excavation by mechanical means(Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in-Charge. 2.6.1 All Kinds of soil |
| 2 | Filling in available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layer not exceeding 20cm in depth consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 3 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidation and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level: 4.1.61:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size). |
| 6 | Providing and lying in position specified grade of reinforced cement concrete, excluding the cost of centering , shuttering ,finishing and reinforcement - All the work up to plinth level: 5.1.11:1.5 :3( Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforced cement concrete work in in beams, suspended floors, roofshaving slope up to 150 landings,balconies,shelves,chajjas, lintels,bands,plain window sills,staircases and spiral stair cases upto floorfive level excluding the cost of centering, shuttering, finishing and reinforcement,with1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and string courses,fillets, columns,pillars,piers,abutments,posts and centering,shuttering,finishing & reinforcement: 5.2.1 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 9 | Reinforcement for R.C.C. work includingstraightening,cutting,bending, placing in position and binding all complete.5.20.1 Thermo-Mechanically Treated bars |
| 10 | Formwork for Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1.Foundation,footings,bases of columns etc.and mass concrete. |
| 11 | 5.9.6.Columns, Pillars, Piers,Abutments, Posts and Struts. |
| 12 | 5.9.5.Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | 5.9.3.Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Brick work with 1st class common brunt clay F.P.S. (non modular) bricks in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 15 | Half brick masonry with 1st class common brunt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in6.9.2 Cement mortar 1:4 (1 cement:4 coarse sand) |
| 16 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid separately:9.1.3.Local best quality Tolhao wood |
| 17 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 9.5.2. Local best quality Tolhao wood 9.5.2.2.30 mm thick shutters |
| 18 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 19 | Providing and fixingISI marked oxidised M.S. sliding door bolts with screws etc. complete 9.36.2. 250x16mm |
| 20 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete: 9.37.4 100x10mm |
| 21 | 150x10mm |
| 22 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete: 9.39.3. 75mm |
| 23 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.2.1.40 mm thick with 20 mm niminal size stone aggregate. |
| 24 | 12mm cement plasterof mix:-13.1.1. 1:4 (1 cement : 4 fine sand) |
| 25 | 15mm cement plaster on rough side of single or half brick wall of mix:-13.8.1.1:3 (1 cement : 3 fine sand) |
| 26 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade:- |
| 27 | Finishing walls with water proofing cement paint of required shade: 13.32.1.New work (Two or more coats applied @ 3.84 kg/10sqm) |
| 28 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge 17.2.110mm dia. |
| 29 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge17.1.75mm dia. |
| 30 | Providing and fixing 100mm HCI bent of required degree with access door, insertion rubber washer 3mm thick bolt and nuts complete |
| 31 | Providing and fixing 50mm HCI bent of required degree with access door, insertion rubber washer 3mm thick bolt and nuts complete |
| 32 | Providing and fixing MS holder bat clamps of approved design to 100mm HCI pipe socket i/c costing of hole and making good the wall etc. |
| 33 | Providing and fixing MS holder bat clamps of approved design to 50mm HCI pipe socket i/c costing of hole and making good the wall etc. |
| 34 | Providing and fixingwhite vitreous China water closet squatting panIndian type 450mm |
| 35 | Providing and fixing white vitreous China pedestal type (European type/wash down type) water closet pan. |
| 36 | White Vitreous China Flat back wash basin of size 450x300mm with single 15mm C.P. brass pillar tap |
| 37 | WATER SUPPLY |
| 38 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.17.7.2.20mm nominal outer dia Pipes (Internal work) |
| 39 | 17.7.1. 15mm nominal outer dia Pipes |
| 40 | Providing and fixing brass bib cock of approved quality:7.11.1.15mm nominal bore |
| 41 | Providing and fixing ball valve (brass) of approved quality, high or low pressure with plastic floats complete:17.14.3.25mm nominal bore |
| 42 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 17.8.2. 20mm nominal outer dia Pipes (External work) |
| 43 | Providing and placing on tarrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 44 | IEI WORKS |
| 45 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5mm2 FR PVC insulatedcopper cond. S/C cable in surface/ recessed PVC conduitwith modular type switch, modular platesuitable size GI- box and earthing the point with 1.5mm2 FR PVC insulated copper. cond. S/C cableetc.as reqd. |
| 46 | 1.Group A |
| 47 | 2.Group B |
| 48 | 3.Group C |
| 49 | S/F (following modular type switch/socket) on the existing switch switch box/cover i/c connection etc. as reqd. |
| 50 | i) 15/16 amps switch. |
| 51 | ii) 15/16 amps socket outlet. |
| 52 | iii) 5/6 amps switch. |
| 53 | iv) 5/6 amps socket outlet. |
| 54 | S/F (following size/ modules) G.I. Box along with modular base and cover plate for modular switch in recessas reqd. |
| 55 | 1. 1 or 2 module (75mmX 75mm) |
| 56 | 2. 4 module (125mmX 75mm) |
| 57 | S/F 305mm sweep exhaust fan complete with all accessoties i/c connection etc as reqd. |
| 58 | Supply of PVC sleeve |
| 59 | S/F 5 amp. to 32 amp. Rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd. |
| 60 | S/F 63amp double pole 240V isolator in the existing MCBDB complete with connection, testing and commissions etc. as reqd. |
| 61 | providing 1 No. of water pump.(i. 1.5 Hp. Pump.) |