Tender For Provn Of Amf Panel And Lt Panel With Associated Accessories For Standby Power Supply To Cpss Building, Pump House And Perimeter Security Lights At 5 Afsb Under Ge (Af) Borjhar
Tender Overview
Project Description
Provn Of Amf Panel And Lt Panel With Associated Accessories For Standby Power Supply To Cpss Building, Pump House And Perimeter Security Lights At 5 Afsb Under Ge (Af) Borjhar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Jan-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-Jan-2025 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for connecting of 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 240 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified including taking out existing unserviceable cable from trenches, floor, ducts, poles or roads complete all as directed |
| 2 | All as per item Srl No 1.00 here in before but for of size 3.5 core 95 sq mm. |
| 3 | All as per item Srl No 1.00 here in before but for of size 3.5 core 120 sq mm. |
| 4 | All as per item Srl No 1.00 here in before but for of size 3.5 core 300 sq mm. |
| 5 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in soft/ loose soil for laying of cable etc complete all as specified and directed by Engr in charge. |
| 6 | Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. |
| 7 | Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed. |
| 8 | M&L for returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. |
| 9 | M&L for removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. |
| 10 | M & L of GI pipe 80 mm dia bore light gradewith all fittings for cable protection, and fixed complete to wall, panel, pole or laid in trenches and road crossingcomplete. |
| 11 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 150 Sqmm, Indoor/ Outdoor type |
| 12 | All as per item Srl No 11.00 here in before but for of size 300 to 400 sq mm. |
| 13 | S&F OnLoad Change Over Switch (in sheet steel enclosure) 315 Amps 415 Volts,50 Hz, 4 pole complete all as specified and directed. Make : L&T/ Siemens/ABB |
| 14 | S&F OnLoad Change Over Switch (in sheet steel enclosure) 125 Amps 415 Volts,50 Hz, 4 pole complete all as specified and directed. Make : L&T/ Siemens/ABB |
| 15 | S&F OnLoad Change Over Switch (in sheet steel enclosure) 100 Amps 415 Volts,50 Hz, 4 pole complete all as specified and directed. Make : L&T/ Siemens/ABB |
| 16 | Supply, install, testing, commissioning of LT AMF Panel for 500 KVA DG Set , IP-65 typeoutdoor type made out of 3.15mm thick CRCAsheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) all as specified and directed. The panel box should have enamelled danger notice plate of 1.6 mm thick, duly painted with two coats of enamel paint over a coat of red oxide primer (internally &externally) on thesurface all as specified and directed by Engr-in-Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty stainless steel door hinges and totally enclosed dust proof and vermin prooffront and backopening with locking arrangements incl necessary control circuit connection and necessary cable connection by lugs and glands incl provision to accommodate battery separately and the following electrical items, Microprocessor based Control and annunciator Unit or Genset Controller Unit for auto or manual starting of diesel generating set & to enemerate alarm to protect the generator against out of range voltage, out of range frequency, over load, low oil pressure, high temperature, low battery voltage including necessary control circuit connection / probe connection from DG Set to control panel-01 No Note : Rate quoted shall inclusive necessary foundation for fixing AMF Panel |
| 17 | Supply, install, testing, commissioning of LT AMF Panel for 63 KVA DG Set , IP-65 typeoutdoor type made out of 3.15mm thick CRCAsheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) all as specified and directed. The panel box should have enamelled danger notice plate of 1.6 mm thick, duly painted with two coats of enamel paint over a coat of red oxide primer (internally &externally) on thesurface all as specified and directed by Engr-in-Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty stainless steel door hinges and totally enclosed dust proof and vermin prooffront and backopening with locking arrangements incl necessary control circuit connection and necessary cable connection by lugs and glands incl provision to accommodate battery separately and the following electrical items , Microprocessor based Control and annunciator Unit or Genset Controller Unit for auto or manual starting of diesel generating set & to enemerate alarm to protect the generator against out of range voltage, out of range frequency, over load, low oil pressure, high temperature, low battery voltage including necessary control circuit connection / probe connection from DG Set to control panel - 01 No Note : Rate quoted shall inclusive necessary foundation for fixing AMF Panel |
| 18 | Supply, install, testing, commissioning of LT AMF Panel for 35 KVA DG Set , IP-65 typeoutdoor type made out of 3.15mm thick CRCAsheet supported and fixed on structural frame, factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) all as specified and directed. The panel box should have enamelled danger notice plate of 1.6 mm thick, duly painted with two coats of enamel paint over a coat of red oxide primer (internally &externally) on thesurface all as specified and directed by Engr-in-Charge. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty stainless steel door hinges and totally enclosed dust proof and vermin prooffront and backopening with locking arrangements incl necessary control circuit connection and necessary cable connection by lugs and glands incl provision to accommodate battery separately and the following electrical items , Microprocessor based Control and annunciator Unit or Genset Controller Unit for auto or manual starting of diesel generating set & to enemerate alarm to protect the generator against out of range voltage, out of range frequency, over load, low oil pressure, high temperature, low battery voltage including necessary control circuit connection / probe connection from DG Set to control panel. 01 No Note : Rate quoted shall inclusive necessary foundation for fixing AMF Panel |
| 19 | Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (manufactured from CPRI type tested manufacturer i.e. Indo Asian/BCH/L&T/Havells) Indoor type made out of 2 mm thick CRCAsheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032(internally &externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front& back door opening, locking arrangements. The Panel should have provision/ accommodation of the following electrical items :- Note : Rate quoted shall inclusive necessary foundation for fixing AMF Panel |
| 20 | INDICATING DEVICES:-(a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No(b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No(c) LED type panel indicator lamp Make - L&T/ Schneider/ Siemens = 03 Nos(d) LCD multifunction meter, Make - ABB/ Siemens/ Legrand/ Schneider/L&T-01 No.BUS BAR:-(e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete =01 SetINCOMING:- (f) Moulded case circuit breaker 320-400 Amps 415 Volts (Vertically Placed),4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T= 01 Nog) 400 A , 4P change over switch front operated-01 No |
| 21 | OUTGOING:-(g) Moulded case circuit breaker 250-315 Amps 415 Volts (Vertically Placed),4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T= 01 No(h) Moulded case circuit breaker 100-125 Amps 415 Volts (Vertically Placed),4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T= 03 No (j) Miniature circuit breaker 63 Amps 230 Volts (Vertically Placed),TPN10 KA breaking capacity,C Curve Make - Siemens/ ABB/ Legrand/L&T= 03 No Note : i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled. |
| 22 | Earthing complete with GI earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25m depth below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to copper strip 25x4 mm mm dia by means of brass nut, bolt, washer & protection pipe for earth lead from the earthing plate to the DB/ main switch/ Panel, (25 mm bore, Light grade), watering pipe from plate to earthing pit (20 mm bore, medium grade), funnel with wiremesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type BI reinforced with 6mm dia TMT rod and suitable handle of 8mm dia TMT rod incl necessary earth work as shown in SSR Part 1 plate No.5 as specified & directed. Note:- i) The copper strip and protection pipe beyond 7.5 m length shall be measured and paid separately. However, earthwork and PCC work for the same is deemed to be included in this rate. ii) The desired value of earth resistanceshould be less than 2Ω , on testing after completion if the desired earth resistance is not obtained; the earthing will be redone at no extra cost, otherwise it will not be measured and paid tothe contractor. iii) Form work of size 0.9m X0.9m X 0.6m for pouring charcoal & salt is deemed to be included in this rateiv) During earth work if surface water found at site, the cost for dewatering through pumpset is deemed to be included in this rate. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued