| 1 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 4 mtrs. height made from 3 mm thick HR Steel plate having bottom dia of 130 mm & top dia of 70 mm complete with window sleeve type cover arrangement at a height of 1.5 mtrs. from the base for cable termination block etc. and galvanized base plate of size 200 mm x 200 mm x 12 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination.a) Supply & fixing 6 mm thick laminated mounted sheet inside the window i/c providing mounting arrangement etc. complete as reqd.b)Supply and fixing 63 amps. terminal block suitable for 16 sq. mm conductor- 4 Nos.on DIN channel i/c pdg. and fixing DIN channel of suitable lengthon the existing laminated sheet. c)Supply & fixing of 6 amp. SP MCB \"C\" characteristics Curve - 2 Nos, earth stud -1 Nos, welded at suitable height one nos washers, springs washers & nuts.d)Cable supports clamps suitable for 4 x 16 sq. mm cable. |
| 2 | Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size300 mm (L) X 300mm wide and 900mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia1000mm long (approx.) 4 Nos. and reinforcement ring of cold twisted bar of 8mm dia -1200mm (approx..) 6 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing 40 mm dia (O.D.) DWC, HDPE pipe of 0.3 mtrs. length for cable entry & exit as reqd. |
| 3 | Supplying and Fixing 4 Nos. 16 mm dia. X 450mm long GI foundation bolt(EN8 grade) with nuts,washer including 2 Nos. template of 3 mm thick size 200mmX200mm with 4 Nos. 20mm dia holes to match with PCD of Pole base plate as reqd. |
| 4 | Supplying, installation, testing & commissioning of Following wattage Top Maintainable Street Light LED fitting (IP-66) made up of pure polyster powder coated pressure die cast aluminium with LEDs haveoptical grade polycarbonate lens & electronic driver for better distribution of light on existing street light pole with power factor≥0.95, THD≤10%, CRI≥70% ,system efficacy ≥120 Lm/W & CCT-3000K with 4KV internal surge protectioni/c makingconnection etc. complete as required. |
| 5 | 120 Watt Street Light Fitting |
| 6 | Fabrication, supplying & fixing of Designer single/double/tripple over hangPU Painted bracket made out of Suitable dia etc. complete as required.(Design as per approved sample). |
| 7 | Supply, installation, testing & commissioning of 60 Watt Decorative LED Fixture, Made with cast aluminium body with cast aluminium four arm, casting thickness is not less than 5mm. Fixture is provided with cast aluminium heat sinks in upper part of fixture, metallic PCB mounted on it and powered by high power Led’s. Fixture dimension are Height -not less than 875mm, Perimeter≥400mm, Gross weight≥19 Kgs. Fixture shall be powder coated /polyurethane painted in Italiancapcicoatgraphitegrey colour . Manufacturer should have BIS approval (R- Number) for post top fixtures. (Note : drawing must be approved by the Engineer-in-Charge before supply of material). |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 9 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Supplying and Laying of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following size in HUME/ DWC Pipe/ Metal Pipe/ RCC Pipe etc. as required. |
| 11 | 4X16 Sq. mm. |
| 12 | 4X10 Sq. mm. |
| 13 | Supplying and drawing following size of PVC insulated Aluminium conductor multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd. |
| 14 | 3 core 2.5 sq.mm Al cable |
| 15 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within50 metres lead as per direction of Engineer-in-charge :bituminous road |
| 16 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. |
| 17 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 18 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 20 | Drilling of hole in top of existing decorative pole & bottom of existing fitting, then Supplying & fixing of 12mm & 100mm long bolt with nut i/c welding of bolt with nut to protect the fitting against theft etc. complete as req. |
| 21 | Welding of base plate of existing 4mtr Decorative Pole with nut of foundation bolt to protect the pole against theft etc. complete as reqd. |