| 1 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 2 | 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 3 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 4 | 1:5:10 (1 cement : 5 coarse sand(zone-III) including manufactured sand derived from Recycled concrete aggregate (RCA) up to 25% : 10 graded stone aggregate 40 mm nominal size including Recycled aggregate (RA)). |
| 5 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 6 | Extra for concrete work in superstructure above floor V level for each four floors or part thereof. |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. |
| 8 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 9 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. |
| 10 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 12 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. |
| 14 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 15 | 250x16 mm |
| 16 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 17 | 250x10 mm |
| 18 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 19 | 100 mm |
| 20 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 21 | Providing and fixing 1st quality rectified ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 23 | (i)Single socketed pipes. |
| 24 | 110 mm diameter |
| 25 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 26 | 110 mm bend |
| 27 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 28 | 110 mm |
| 29 | 12 mm cement plaster of mix : |
| 30 | 1:6 (1 cement: 6 fine sand) |
| 31 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 32 | 1:6 (1 cement: 6 fine sand) |
| 33 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 34 | Two coats. |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 37 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 38 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 39 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 40 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 41 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 42 | a) With cement mortar 1:4 (1 cement : 4 fine sand). |
| 43 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 44 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 45 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 46 | In cement mortar |
| 47 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 48 | Of area 3 sq. metres and below |
| 49 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 50 | For thickness of tiles 10 mm to 25 mm |
| 51 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 52 | 75 to 80 mm dia pipe. |
| 53 | 100 mm dia pipe |
| 54 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 55 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 56 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 57 | W.C. pan with ISI marked white solid plastic seat and lid |
| 58 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 59 | Kitchen sink without drain board |
| 60 | 610x510 mm bowl depth 200 mm. |
| 61 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm incl cutting and making good the walls and floors wherever required : |
| 62 | Range of two half stall urinals |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 64 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 65 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 66 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 67 | Rectangular shape 453x357 mm |
| 68 | Rectangular shape 1500x450 mm |
| 69 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 70 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 71 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 73 | 20 mm nominal outer dia. Pipes. |
| 74 | 25 mm nominal outer dia .Pipes. |
| 75 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 76 | 25 to 40 mm nominal bore |
| 77 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 78 | 30 cm length |
| 79 | 15 mm nominal bore |
| 80 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 81 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 82 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 83 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 84 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 85 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: |
| 86 | (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. |
| 87 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 88 | (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 89 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 90 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. |
| 91 | The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 92 | Note :- (1) The elevational area of the scaffolding shall be measured for payment purpose. |
| 93 | (2) The payment will be made once only for execution of all items for such works. |
| 94 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 95 | 25 mm average thickness |
| 96 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 97 | Bars upto 12 mm diameter |
| 98 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 99 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 100 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. |
| 101 | Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 102 | 12 mm average thickness. |
| 103 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). |
| 104 | Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 105 | Frame size 65 x 100 mm |
| 106 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 107 | 30 mm thick |
| 108 | Dismantling 20 to 25mm dia GI pipeline incl stacking of dismantled pipes within 50m lead as per direction of Engineer in charge. |
| 109 | Providing and fixing CP Brass health faucet with CP pipe with holder of 15mm nominal bore nozzle jet and handle of approved quality and make adjacent to WC as per the directions of engineer in charge. (Nothing extra paid)., as directed by the Engineer-in-charge. |
| 110 | Providing and fixing C.P. brass two way (2in1) bib/ stop cock of approved quality conforming to IS standards and weighing not less than 690 gms. a)15 mm nominal bore |
| 111 | Providing and fixing rectangular shaped urinal partition with 8mm thickfrosted glassof size 900mm x 450mm incl chrome finish cleats complete as per direction of Engineer-in-charge |
| 112 | Providing and fixing unplasticised Rigid PVC floor trap conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including cost of cutting and making good the walls and floors : (a) 100 mm inlet and 75 mm outlet |
| 113 | Providing & fixing Type BSWR PVC pipes by cutting, removing, replacingincluding jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 and with solvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant. |
| 114 | 110mm diameter |
| 115 | 75mm diameter |
| 116 | Providing & fixing sanitary fittings/ accessories with new PVC SWR fittings /accessories including cutting, replacing, jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 117 | Plain Bend |
| 118 | 110mm diameter |
| 119 | 75mm diameter |
| 120 | Tee with door |
| 121 | 110X110X110 |
| 122 | 75X75X75 |
| 123 | Y- with door |
| 124 | 110mm diameter |
| 125 | 75mm diameter |
| 126 | Providing and fixing 32 mm dia PVC rigid pipe forwash basin as waste pipe. The pipe shall be of length upto 600mm including P.V.C. waste fittings, P.V.C bend, union etc and fixing the pipewith clamps on wall surface, all as per site requirement, . All complete as directed by the Engineer in charge. |
| 127 | Providing and fixing 32 mm dia PVC rigid pipe forUrinal basin as waste pipe. The pipe shall be of length upto 450mm basin including all P.V.C.fittings, like P.V.C bend etc and fixing the pipewith clamps on wall surface, all as per site requirement, . All complete as directed by the Engineer in charge. |
| 128 | Providing and fixing 50 mm dia rigid PVC pipe as drain pipe near urinal basins. The pipe shall be fitted on the wall surface with necessary clamps at suitable intervals. Necessary diameter PVC \"TEE\" (REDUCER TEE) shall be fixed in this pipe line and arrangements shall be made such that the 32 mm dia waste pipe from the urinal basins shall be fixed properly in this 50 mm dia pipe ensuring proper draining. All complete and as per directions of the Engineer - in - charge. The 50 mm dia pipe shall be measured for payment and nothing extra shall be paid on any account. |
| 129 | Supply, fixing 8mm thick grid PVC false ceiling tiles of size 600x600mm of approved texture, design and patterns in true horizontal level suspended on interlocking level metal powder coated T-Grid sleek frame work Connected to ceiling with GI wire and anchor fastener at every junction and also including cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed all complete as per direction of Engineer-in-charge. |
| 130 | Extra for providing Aluminium louvers frame of 100mm width for ventilators with adjusting system for glass louvers etc., complete as per direction of Engineer in charge(Louvered glass will be paid separately, length of aluminum frame is measured for payment) |
| 131 | Providing and fixing CP brass grating of approved quality and colour. (a)Circular type.(i) 100 mm nominal dia. |
| 132 | Carrying of dismantled materials manually by head load from fifth floor to Ground floor and dumping at ground floor for further disposal as directed by Engineer-in-Charge. |
| 133 | Dismantlingpowder coated / anodized aluminium partitions, doors and other frames including proper numbering, loading and unloading and stacking by placing at the required place in the building premises etc. all operations complete as directed by the Engineer-in-charge . (Area of partition is measured for payment) |
| 134 | Fixingpowder coated / anodized aluminum partitions and doors at all levels & heights with available materials at stores after making required sections as per the drawing for powder coated aluminum sections , particle board, glass panels and snap on beading including fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides wherever required etc,all operations completeas perthe directions of the Engineer-in-charge. |