| 1 | Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness below or above ground level, removal of rubbish and debris outside MOD land complete all as directed. |
| 2 | M&L for plain cement concrete1:4:8 type D2 using 40mm graded aggregate as in sub base of floor, foundation, filling and mass concrete complete |
| 3 | M&Lfor 50 mm thick Cement concrete typeB-2, 1:2:4 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and directed. |
| 4 | M&L for chequered cement concrete tile machine pressed PU coated with grey cement and pigment of size 300x300x19/20mm laid over screed bedding layer 15 mm thick in CM 1:6 complete all as specified and directed. |
| 5 | S&F factory made PCC kerb stone of size 600x250x100mm thick as in sides of paths, jointed in CM 1:4,including dismantling of old stones complete all as directed |
| 6 | M&L preparation of newor previously untreated surfaces of brick, stone, concrete asbestos or plaster surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paint over a coat of priming paint ( plaster coat) complete. |
| 7 | M&L for framed workin repairs such as grills,gate, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. |
| 8 | M&L for preparation of new steel Surfaces of any description, over10cm in width or girth,not otherwise described and appying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed |
| 9 | S&F Cast Iron soil waste and vent pipes 100mm borein any length with or without ears, with cement joints , fixed to walls, including taking down old unserviceable pipe complete all as directed. |
| 10 | S & F Cast Iron soil waste and vent pipes 75mm borein any length with or without ears, with cement joints , fixed to walls, including taking down old unserviceable pipe complete all as directed. |
| 11 | S & FCI bends/T/Y of (any radius) with doorsuitable for 100mm bore pipeincluding taking down old unserviceable bend complete all as directed. |
| 12 | S & FCI bends /T/Y of (any radius) with door cover suitable for 75mm bore pipeincluding taking down old unserviceable bend complete all as directed. |
| 13 | S&F in repairs PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls as in rain water pipes complete all as directed |
| 14 | S & F in repairsPVC (SWR) bends 110mm bore any radius for rain water pipes complete all as directed |
| 15 | S&F 150 mm PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls including all fittings (such as bends, elbows, Tee, short pieces, connectors, backnuts, diminishing pieces, caps,plugs and unions etc)complete all as directed. |
| 16 | S & F in repairsPVC (SWR) bends 150mm bore any radius for rain water pipes complete all as directed |
| 17 | M & L for Brick work with sub class \"B\" old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4)including demolition of old brick work complete all as directed. |
| 18 | M & L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick/Stone or concrete surfaces, finished even and smooth without using extra cement complete all as directed. |
| 19 | M&L for preparation of Newlyplasteredsurfaceand applying two coats of exterior antifungal exterior paint as per manufacturers instructions over a coat of true care exterior wall primer over two coats of external birla putty 1.5mm thick each layer each to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed by Eng-in-charge. Make:- APEX ULTIMA of ASIAN PAINT/ WEATHER COAT SMOOTH (BERGER PAINTS)/ WEATHER SHIELD MAX EXTERIOR ACRYLIC(DULUX)Note :The work will be executed on upto 4th floor cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor |
| 20 | M&L 18 mm thick granite (any colour) work as in pillars, display boards, wall cladding and like incl 15 mm thick screed bedding in CM (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitestone including grinding and polishing, rounding of edges andincluding dismantling old work complete, all as specified and directed.Note : Granite colour approved by Engr-In-Charge. |
| 21 | Supply & fixing of UPVC windows or UPVC framed portion 3 track 3 panel sliding window with two glazed and one wire mesh sliding shutters of profile width of from 40 mm to 45 mm, limit thermal conductivity to l.3 Kcal/sqm/hr centigrade, sound insulation up to 4-0 bds, Density, 1.46 gm/ml, Tenstile strength - 43.9N/sqmm, % Elongation at break - 215, Tenstile mpduls - 2840N/Sqmm, Flexural strength - 51N/sqmm, Heat aging at 150 degrees - No surface defect, Thickness - 2 mm, Flexural moduls elasticity2200N / sqmm, double baskets & wool pile on window, multi point gear locking at different sides of frame, anti lift device on slide windows with temper proof screws with and including glazed shutter fixed with 5 mm thick plain sheet glass & wire mesh shutter with stain less steel wire cloth 304 grade stainlesssteel with 0.254 mm (30 gauge) dia of steel wire and 0.95 mm width of aperature and any hight complete all as directed by Engr-in-charge all as specified. |
| 22 | M&L for complete removal of existing treatment fromsurfaces of walls/ ceiling, washing with water and applying two coats of Premium emulsionpaint as per manufacturers instructions over a coat of primer over two coats ofputty 1.5mm thick each layer each to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed by Eng-in-charge. Note:-(i)The putty surface should be finished even smooth and dent free before application of primer, stage passing shall be taken for each building at every stage.. |