| 1 | Supply, installation, testing and commissioning of following capacity standard make openwell submersible motor pump set for operation on 3 phase 415 volts, 50Hz AC supply. The pump should be of following discharge capacity, head and delivery size and suitable for installation in the exisiting sump as per details below:-Working Liquid : Clear water.Head Range : 40 MDischarge : 360 LPSRating :5.5 KW / 7.5 HP, 3 Phase 415 VoltsMethod of Starting : DOL Starter.(Starter not included)(MR) |
| 2 | Supply, installation, testing and commissioning of following capacity standard make multi stage submersible motor pump set for operation on 3 phase 415 volts, 50Hz AC supply. The pump should be of following discharge capacity, head and delivery size and suitable for installation in the exisiting sump as per details below:-Working Liquid : Clear water.Head Range : 180 MDischarge : 3000 LPHRating :4.0 HP, 3 Phase 415 VoltsMethod of Starting : DOL Starter.(Starter not included) (MR) |
| 3 | Erection of the 7.5 HP borewell submersible pumpset and 50 mm dia HDPE pipe from bore well of depth upto 500 mtrs, etc., complete as required.(MR) |
| 4 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 50 mm dia (OD- 50 mm nominal)(MR) |
| 5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal dia Pipes (DSR No - 18.9.6) |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)(DSR No -14.16.1) |
| 7 | Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (Screwed ned) :50mm(DSR No -18.17.4 ) |
| 8 | Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (Screwed ned) :40mm(DSR No -18.17.3) |
| 9 | Providing and fixing gun metal non- return valve of approved quality (Screwed end) :40mm(DSR No - 18.19.3.2) |
| 10 | Providing and fixing gun metal non- return valve of approved quality (Screwed end) :50mm(DSR No -18.19.4.2) |
| 11 | Supplying and fixing of Outdoor type panel with in-built DOL starter 1 No. 32 A 3P MCB, Over Load Protection, single phase preventor, selector switch 3 Nos with suitable angle iron frame of size 35mm x 35mm x 5mm i/c connections etc. as required. (MR) |
| 12 | Supplying and fixing of indoor type panel board with in-built 7.5 HP DOL starter 2 Nos. 32 A TP MCB, 2 Nos. 100A FP MCB 1 No. indication lamp, voltmeter 1 No. / ammeter 2Nos., selector switch 3 Nos. single phase preventor 2 Nos. with suitable angle iron frame of size 50mm x 50mm x 5mm i/c connections etc. as required. (MR) |
| 13 | Supply and laying of PVC insulated copper 3 x 4 Sqmm flat submersible cable as required (MR) |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 25 sqmm (28mm) (MR) |
| 15 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm (DSR No -7.1) |