Tender For Improvement In Electrical Infrastructure In Certain Smqs At Old Project Area
Tender Value
27 Lakhs
Estimated cost
Bid Submission
10 Jan 2025
0 days left
EMD
54000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
manauri → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Improvement In Electrical Infrastructure In Certain Smqs At Old Project Area
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete removing material to store of keeping in safe custody or for taking creditand making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 2 | Material and labour for point wiring includingconcealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM diawith 1.5 Sqmm FRLS insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixingsuch as switches, sockets and fan regulators etc and fixing with brass screws/cup washer and including FRLS insulated & unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 Sqmm as continous earth wire complete including making good the disturbed surfaces for the following:- Note:-Quoted rate shall be included cost of cheasesing, cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site requiredmatchingwith existed surface and blank plate to be cover up to extra gap in mountingboard in given module /make / model etc. |
| 3 | All as per item No. 2.00 above but One light / Fan point controlled by one way indepdentswitch complete all as specified and directed. |
| 4 | All as per item No. 2.00 above but One Bell pointcontrolled by one way indepdentswitch complete all as specified and directed. |
| 5 | All as per item No. 2.00 above butOne 3 pin 5 Amps socket out let point on same board controlled by one switch complete all as specified and directed. |
| 6 | All as per item No. 2.00 above butOne 3 pin 5 Amps socket out let point on independent board controlled by one switch complete all as specified and directed. |
| 7 | All as per item No. 2.00 above but point wiring for 15 Amps socket using 2.5 Sqmm copper cable for phase and neutrl and 2.5 Sqmm as earth wire complete all as specified and directed. |
| 8 | S&Fmodular switch , one way 6 Amps 1 module complete all as specified and directed. |
| 9 | S&F modular switch, one way 16 Amps 1 module complete all as specified and directed. |
| 10 | S&Fmodular bell push6 Amps 1 modulecomplete all as specified and directed. |
| 11 | S&F modular socket 6 A, 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 12 | S&Fmodular socket 16 A, 3/5 pin combined 2 modulecomplete all as specified and directed. |
| 13 | S&Fceiling rose surface type 65 MM x 50 MM, 2 to 3 terminal. complete all as specified and directed. |
| 14 | S&Fin replacement modular fan regulator step type 120 W 2 module complete all as specified and directed. |
| 15 | S&F in replacement white cover plate with frame 2 module complete all as specified and directed. |
| 16 | S&F in replacement white cover plate with frame 3 module complete all as specified and directed. |
| 17 | S&F in replacement white cover plate with frame 4module complete all as specified and directed. |
| 18 | S&F in replacementwhite cover plate with frame 6module complete all as specified and directed. |
| 19 | Supply and fix sheet metal enclosure withdistribution board TPN, 4 poles ,double door, 4 way with 240 Amps ratedbus bar vertcal type withMCCB 4 pole 100 Amps 415 volt thermal megnatic base operated as incomer incl concealed in surface of wall and making all connection using gland , thembles in required size including taking down to old unsv DBs in any make/ model/ way etc with accessories complete all as specified and directedNote; Quoted rate shall be included cost of MCCB , cutting plastering , colouring to surface of wall to be concealedetcall site requiredmatching with existing surface complete all as specified and as directed. |
| 20 | M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size not less than 25 mm dia with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring including taking out to old unsv sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmmwith one run of PVC conduit pipe shall be measured agaist one unit. (ii)Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed. |
| 21 | All as per item No. 15.00 above but three run of4 Sqmm for phase ,neutral and earth wire with suitable size not less than 20 mm dia concealed PVC conduit pipe complete all as specified and directed. |
| 22 | S&FSingle pole and neutral enclosure with a two pin and earth plug and socket20Amp 240V, for AC boxwith one single pole MCB of 20 Amp complete all as specified and directed. |
| 23 | S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unsv DBs in any make/ model/ way etc with accessories complete all as specified and directed. |
| 24 | S&F MCB , SPN, 2 pole 220 volts , 40 Amps , \"C\" Curve 10 KA complete all as specified and directed. |
| 25 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 26 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth leadusing galvanised earth lead wire 4.0mm dia means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. |
| 27 | Item No 21 Contd(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.(iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 28 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |
AI Tender Summary
Tender Timeline
Dec 18, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJan 10, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 13, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer