| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-12-2024 | corrig 01 | Technical Bid | 10-01-2025 |
| Sl. No. | Item Description |
| 1 | Supply of shaft encoder based rotary position sensor with digital display type gate position sensors for indication and monitoring of canal gates, including cabling and integration with PLC/ RTU/ Datalogger complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 2 | Supply of side looking ADVM (Acoustic doppler Velocity meter) for downstream discharge measurement in head /cross regulators with the bed width of (0-20m) including integration with PLC/RTU/Datalogger complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 3 | Supply of Side looking ADVM (Acoustic doppler Velocity meter) for downstream discharge measurement in head /cross regulators with the bed width of more than 20 meters including integration with PLC/RTU/Datalogger complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 4 | Supply of Battery (inbuilt/external) operated RADAR level sensor having range 0-4 m, with GSM/GPRS modem & necessary hardware for installation as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 5 | Supply of Datalogger/RTU with 8 channel input type with GPRS/GSM based telemetry including antenna, Enclosure and all necessary equipment for data transmission for remote monitoring stations, as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 6 | Supply of RTU/datalogger with 16 channel input type with GPRS/GSM based telemetry including antenna, Enclosure and all necessary equipment for data transmission for remote monitoring stations, as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 7 | Supply of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduits for cable for providing uninterrupted power supply to RTU/Datalogger system installed as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 8 | Installation, testing & commissioning of shaft encoder based rotary position sensor with digital display type gate position sensors for indication and monitoring of canal gates, including cabling and integration with PLC/RTU/Datalogger complete as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 9 | Installation, testing & commissioning of side looking ADVM (Acoustic doppler velocity meter) for downstream discharge measurement in head /cross regulators with the bed width (5- 20m) including retractable mounting frame, cabling, installation accessories and integration with PLC/RTU/Datalogger and associated civil works complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 10 | Installation, testing & commissioning of Side looking ADVM (Acoustic doppler Velocity meter) for downstream discharge measurement in head /cross regulators with the bed width of more than 20 meters, including retractable mounting frame, cabling, installation accessories and integration with PLC/RTU/Datalogger and associated civil works complete as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 11 | Installation, testing & Commissioning of Battery (inbuilt/external) operated Ultrasonic/RADAR level sensor having range 0-4m, with GSM/GPRS communication system for canal with other ancillary equipment and all necessary mounting hardware as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 12 | Installation, testing and commissioning of Datalogger/RTU with 8 channel input type with GPRS/GSM based telemetry including antenna and all necessary equipment for data transmission for remote monitoring stations, as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 13 | Installation, testing and commissioning of RTU/Data logger with 16 channel input type with GPRS/GSM based telemetry including antenna and all necessary equipment for data transmission for remote monitoring stations, as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 14 | Installation, testing & commissioning of Solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduits for cable for providing uninterrupted power supply to RTU/Datalogger system installed as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 15 | Training of the purchaser\"s personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU and Canal monitoring configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 16 | NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format with dedicated sufficient Hard Drive to have memory of at least 30 days as per technical Specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 17 | Supply of automated water level transmitter non-contact RADAR type having 0-10 m range for measuring upstream level and downstream discharge in canal across Head & cross regulator including cabling with suitable conduits and electrical fitting and mast complete as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 18 | Supply of VSAT system for communication between master and local canal Monitoring station for the IGNP canal system with necessary accessories as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 19 | Supply of LTE based Bullet Camera (Fixed Type)- IP DIGITAL Night Vision (I.R.) Outdoor Weather Resistant, 2 Mega Pixel, 72 LED Colour Camera. 6 OR 8 or 12 MM (According to site suitability) 2 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66, for monitoring the gates operation complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 20 | Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP based (DIGITAL) Camera, 500 meters. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing at cross regulator. Outdoor weather resistant IP 66 including recording and cabling required for monitoring and. As per technical specifications and as per grouping of Instruments.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 21 | Supply, engineering, and development of customized Irrigation monitoring software which shall include Canal Monitoring software for monitoring & controlling of canal operations, water scheduling, real time data logging for complete canal automation with lifetime licensed version as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 22 | Supply of industrial grade server which includes server with server rack and Industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to RTDAS System complete for Canal Systems, as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 23 | Supply of IT hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 color printer as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 24 | Supply of 80inch LED display /DLP video wall system for monitoring of Canal monitoring & Surveillance system at Canal Monitoring room as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 25 | Supply of online 3 KVA UPS with battery system for power back up of Canal monitoring control room equipment as per the technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 26 | Supply of diesel generator Set 10 KVA with 04 Earth Pits for earthing and all associated accessories at Canal monitoring control room as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 27 | Supply of Laptop & 5G/4G internet dongles along with licensed version of Client canal monitoring software for remote viewing and monitoring of IGNP Canal system as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 28 | SITC of air cooled split air conditioners complete with indoor unit(IDU), outdoor unit (ODU), surface / concealed copper refrigerant piping with insulation (ep foam pipe section) upto 3 mtr (IDU TO ODU), copper power cable up to 4 mtr (IDU TO ODU), r-22/r-410 refrigerant, remote, suitable for 400/230V +10% of 50 Hz, 1 /3 Phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ resprocating/ rotary compressor as specified. Group-1 (1.5 TR with 5-star rating of BEE ).( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 29 | Supply of chairs type 2 (castors without, type of seat and backrest - seat made of polyurethane foam and backrest made of mesh, chair type with arms, type -cantilever.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 30 | Supply of workstation (overall height of workstation partition-1200 mm, size of drawer unit (width x depth x height) - 390x440x147 (mm), depth of tabletop - 750 mm, Length of tabletop- 1200 mm).( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 31 | Supply of almirah (thickness of sides in mm - 30mm, height in mm - 1350, depth in mm - 450, width in mm - 760) inclusive all taxes( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 32 | Installation, testing & commissioning of automated water level transmitter non-contact RADAR type having 0-10 m range for measuring upstream level and downstream discharge in canal across head & cross regulator including cabling with suitable conduits and electrical fitting, mast/cantilever and associated civil works complete as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 33 | Installation, testing & commissioning of VSAT system for communication between master and local Canal monitoring control station for the IGNP canal system with necessary accessories as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 34 | Installation, testing & Commissioning & integration with NVR located at Control Room, of Bullet Camera (Fixed Type)- IP DIGITAL Night Vision (I.R.) Outdoor Weather Resistant, 2 Mega Pixel,72 LED Colour Camera. 6 OR 8 or 12 MM (According to site suitability) 2 MP Auto Iris Lens in Elegant Metal Die Cast Housing. Outdoor weather resistant IP 66 for monitoring the gates operation, complete in all respects as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 35 | Installation, testing & Commissioning of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP based (DIGITAL) Camera, 500 meters. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing at cross regulator. Outdoor weather resistant IP 66 including recording and cabling required for monitoring and. As per technical specifications and as per grouping of Instruments( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 36 | Installation, testing & commissioning of customized Irrigation monitoring software which shall include Canal monitoring software for monitoring & controlling of canal operations, water scheduling, Real time data logging for complete canal automation with lifetime licensed version as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 37 | Installation, testing & commissioning of industrial grade server which includes server with server rack and industrial grade monitor with USB, RS232/RS485, Ethernet ports, OS windows 8 or higher compatible to Canal monitoring system complete for IGNP canal systems, as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 38 | Installation, testing & commissioning of IT hardware which includes required static IP, router with modem, Switch, firewall system and A3 color printer as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 39 | Installation, testing & commissioning of 80inch LED display /DLP video wall system for monitoring of Canal monitoring & surveillance system at Canal monitoring control room as per technical specification. |
| 40 | Installation, testing & commissioning of online 3 KVA UPS with battery system for power back up of Canal monitoring control room equipment as per the technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 41 | Installation, testing & commissioning of diesel generator Set 10 KVA with 04 Earth Pits for earthing and all associated accessories at Canal monitoring control room as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 42 | Charges for high-speed synchronous internet connection (minimum 8mbps upload & download speed) & static IP for canal system for five years( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 43 | Charges for 5G/4G internet dongles for five years which is to be provided along with laptop and industrial grade computer having lifetime licensed version of client Canal monitoring software for remote viewing and monitoring of canal automation as per technical specifications.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 44 | Supply of Local Display Unit (LDU) for RTU/Data logger( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 45 | Supply Of Outdoor Display Board Unit (ODBU)( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 46 | Installation, testing & Commissioning Local Display Unit (LDU) for RTU/Data logger( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 47 | Installation, testing & Commissioning Of Outdoor Display Board Unit (ODBU)( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 48 | Supply of 55inch LED display /DLP video wall system for monitoring of RTDAS & Surveillance system at Canal Monitoring control room as per technical specification( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 49 | Installation, testing & commissioning of 55inch LED display /DLP video wall system for monitoring of Canal monitoring & surveillance system at Canal monitoring control room as per technical specification.( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 50 | Supply of Acoustic Doppler Current Profiler (ADCP) having velocity profiling range 0.4 to 40 Meters with compatible DGPS and associated peripherals, laptop along with software and with all accessories for discharge measurement of canal systems and required attachment at site, complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 51 | Supply of Acoustic Doppler Current Profiler (ADCP) having velocity profiling range 0.25 to 5 Meters with compatible DGPS and associated peripherals, laptop along with software and with all accessories for discharge measurement of canal systems and required attachment at site, complete as per technical specifications( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 52 | Installation, testing & Commissioning of Acoustic Doppler Current Profiler (ADCP) having velocity profiling range 0.4 to 40 Meters with compatible DGPS and associated peripherals, laptop along with software and with all accessories for discharge measurement of canal systems and required attachment at site, complete as per technical specifications till warranty and O&M period( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 53 | Installation, testing & Commissioning Acoustic Doppler Current Profiler (ADCP) having velocity profiling range 0.25 to 5 Meters with compatible DGPS and associated peripherals, laptop along with software and with all accessories for discharge measurement of canal systems and required attachment at site, complete as per technical specifications till warranty and O&M period( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 54 | Five Years Operation & Maintenance and Comprehensive Warranty for Canal automation system along with accessories, installed at designated locations within IGNP canal system Rajasthan after final acceptance of Canal automation system. This includes replacement of material and consumable (batteries) as and when required at bidders’ cost. The cost of communication for GSM & GPRS (SIM and internet charges) for data transmission shall be borne by bidder. Minimum Two service engineer shall be placed at each Canal monitoring Control Room for Operation of Canal Canal monitoring system for entire warranty of period five years( Referance-F.36(Misc)37/Tech/ACE/IGNP) |
| 55 | Earth work in excavation by machanical means( Hydraulic excavator) /manual means in foundation trenches or drains ( not exceeding 1.5mtr in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 Mtr. Including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr. all kinds of soil. |
| 56 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 57 | Brick masonary with common burnt clay FPS (Non Modular) bricks of class designation7.5 in ,:foundation and plinth with Cement mortar 1:6 ( 1 Cement : 6 Coarse sand). |
| 58 | Plaster on new surface on walls in cement sand mortar 1 : 4 including raking of joints etc. complete fine finish: 12 mm thick. |
| 59 | Providing & fixing precast cement concrete coping 1:2 :4 mix 50mm thick complete as per specification : |
| 60 | Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete :300mm dia Internal |
| 61 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia Add extra for excavating trench for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 Mtr. but not exceeding 3 Mtr |
| 62 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 63 | Supply of fiberglass reinforced plastic (FRP) Gauge plate for accurate measurement of water level, moulded and sandwiched with MS strip both side finish, front side engraved and moulded computerized marking of bands and figures covered in radium, eye pleasent colour combination, laminated with high abrasion grade polyurethene, provision of MS pressed channel for gauge plate more than60 cm width etc.15 cm wide |
| 64 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).. |
| 65 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 66 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 67 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 68 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 69 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 70 | Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 71 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 72 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.110 mm dia |
| 73 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. Single Bend w/o Door 87.5° 110 MM dia |
| 74 | P & F ms sheet single leaf door shutters in angle iron frame 35×35×5 mm suitably diagonally braced with 25×3 mm flat ironabove and below lock rail of size 50×5 mm beading extra including all fittings , as per direction of engg. In charge but excluding cost of chokhats including two coats of anti corrosive red oxide primer paint. . |
| 75 | P&F steel glazed doors, windows and ventilators shutters of standard rolled steel section joint mitred and welded with steel 13×3 mm lugs 10 cm. long embedded in cement concrete blocks 15×10×10 cm of 1:3:6 ( 1- Cement : 3- coarse sand : 6 - graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and fittings except neccessary hinges of pivots steel handles and peg stay etc. as required. Windows side hung. /Ventilators top or centre hung(openable) |
| 76 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on New Work |
| 77 | Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge :Profile B |
| 78 | Brick on edge flooring with bricks of class designation 75 including cement slurry& pointing in CM (1 : 3) etc. complete laid on20 mm thick bed of :Cement Sand Mortar 1 : 4 |
| 79 | 40mm thick marble chips flooring rubbed and polished to granolithic finish under layer 31mm thick cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nominal size) including fixing of dividing strip (excluding the cost of strips) and top layer 9mm thick with marble chips of approved colour & 4mm to 7mm nominal size laid in cement marble chips2 : 3 (2 cement: 3 marble chips) by volume including cement slurry etc. completeWhite cement without any pigment |
| 80 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 81 | Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding. |
| 82 | Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision New |
| 83 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this |
| 84 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduitand amp; its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheetsand amp; Electrical/ Wiring accessories refer Chapter E - 04, E - 05and amp; E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - On board |
| 85 | S and amp;F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR - 20 mm |
| 86 | Supplying and drawing FR PVC insulatedand amp; unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 87 | Pand amp; F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 1.2 mm thickM. S. Sheet boxes -200mm x 150mm x 60mm |
| 88 | Pand amp; F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR |
| 89 | Providingand amp; Fixing of modular type 12W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screwsand amp; silver alloy contact tipwith IP-2rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR - 5 step fan regulator 2 Module 36dgree rotating |
| 90 | Providingand amp; Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium bodyand amp; Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ;and amp; Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer AnnexureAattached with this BSR . -1200 mm Sweep BEE 1 Star rated (service valueand gt;=4.0 toand lt; 4.5 ) |
| 91 | Providingand amp; Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports and amp; All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator - 30 A / 40 A rating |
| 92 | Providingand amp; Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 Aand amp; above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports and amp; All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) - 6 A to 32 A rating |
| 93 | Providingand amp; Fixing of IP 20 boxmade outfrom 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating andsuitable for mounting LED tubeincludingside covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer AnnexureAattached with this BSR . -Suitable for 4 LED Tube shape fixturefor single rod |