Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #46749380

Tender For Provision Of Compound Wall For Technical Buildings (Under Wp-12) At Naob, Rambilli Near Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · rambilli, Andhra Pradesh
Tender Value
39.75 Crore
Estimated cost
Bid Submission
10 Mar 2025
0 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rambilli → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Provision Of Compound Wall For Technical Buildings (Under Wp-12) At Naob, Rambilli Near Visakhapatnam Provision Of Compound Wall For Technical Buildings (Under Wp-12)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Jan-2025 Postponement Date 17-Feb-2025
2 06-Feb-2025 Postponement2 Date 03-Mar-2025
3 20-Feb-2025 Postponement3 Date 10-Mar-2025
4 20-Feb-2025 Revised BOQ BOQ 10-Mar-2025

BOQ

Name of Work: PROVISION OF COMPOUND WALL FOR TECHNICAL BUILDINGS AT NAOB (WP-12), RAMBILLI NEAR VISAKHAPATNAM.
Sl. No. Item Description
1Surface dressing n. exc 15 cm in depthand getting out insoft/loose soil including disposal of soil to a distance not exceeding 50 Mts etc., complete all as specified and as directed by the Engineer-in-Charge.
2All as per Item No. 1 here-in-before butinhard/dense soil complete.
3Clearance of jungle in proposed alignment for compound wall/structure including cutting of bushes any girth, shurbs, trunks, stump roots, branches of trees, grass weed including required excavation, removal and disposal of unserviceable materials and rubbish to a distance not exceeding 50 Mts etc., complete all as specified and as directed by the Engineer- in-Charge.
4Excavating in post holes (or similar holes) in any type of soil each n exc 0.5 Cu.m., getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm, watering and removing surplus soil to outside MD land as directed by GVMC and making good surface complete all as specified and as directed by the Engineer- in-Charge.
5Excavation over areas n. exc. 1.5m deep for foundations, beams, Pile capsand getting out insoft /loose soil complete all as specified and as directed by the Engineer-in-Charge.
6All as per Item No. 5 here-in-before butinsoft/ disintegrated rockl complete.
7Excavation in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc.,n exc 10 sq m on plan and getting out in soft/loose soil all as specified and as directed by the Engineer-in-Charge.
8All as per Item No. 7 here-in-before but exc.1.5m andup to 3.00m in depth complete.
9All as per Item No. 7 here-in-before butinsoft/ disintegrated rockl complete.
10Removal of excavated material to a distance n. exc. 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
11Returning, filling in including, spreading, levelling, watering and well ramming in layers n. exc. 25cm thick complete all as specified and as directed.
12Material & labour for drilling or boring for 800mm nominal dia. bored cast-in-situ piles, through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting DMC (Direct Mud Circulation) method with perennial water and disposal of drilling/bored materials to a distance n.exc 50m. and depositing where directed complete all as specified and as directed by Engineer-in-Charge.
13All as per Item No. 12 here-in-before but 600mm nominal dia
14Notes for Item Nos. 12 to 13 :-(i) The depth of boring for piles shall be measured from existing ground/sea bed level/river bed top (as per soundings/reduced levels taken at the commencement of work) to the approved founding level.(ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE by contractor at his own cost. The distance mentioned in description of item shall be the shortest distance from the centre of the building.(iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes.(iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt.The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles.Nothing extra shall be paid.(v) The rates quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
15Carrying out initial load tests on test pilesin land as per standard procedure laid down in IS-2911 by static load test method including compressive strength including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and directed by GE and submission of reports for a test load of 2.50 times of design load (Design load 55 MT) in non-working areas in the vicinity, including the cost of new piles for 800mm dia with specification as same as working pile etc all as specified and directed.
16All as per Item No. 14 here-in-before but 600mm nominal dia. for a test load of 2.50 times of design load (Design load 55 MT).
17Carrying out routine load test (working pile) in land as per standard procedure given in IS-2911 (Part IV) 1985 by static test method for 800mm dia. Piles for a test load of 1.50 times of design load (Design load 55 MT) complete all as specified and as directed by Engineer-In-Charge
18All as per Item No. 16 here-in-before but 600mm nominal dia. for a test load of 1.50 times of design load (Design load 55 MT).Note for item No. 16 & 17:- The pile shall be selected by the GE. The method of testing adopted by the contractor shall be as approved by Accepting Officer.
19M&L forPCC 1:3:6 type C2 (using 40mm graded Granite stoneaggregate) as in foundation filling, mass concrete and underneath pile caps, beams, plinth protectionetc. complete all as specified and as directed by the Engineer-in-Charge.
20M&L forPCC 1:4:8 type D2 (using 40mm graded Granite stoneaggregate) as in foundation filling, mass concrete and underneath pile caps, beams, plinth protectionetc. complete all as specified and as directed by the Engineer-in-Charge.
21M&L for Providing, cement concrete (1:2:4) type B1 (using 20mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, surface channel benching/ haunching and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge.
22M&L for reinforced cement concrete (Ready mix concrete) by design mix M-40 grade (Using 20mm graded stone aggregate) as in bore holes using Portland slag cement and admixture conplast SP-430 A2 or equivalent for piles in tremie methodincluding necessary dewatering, formwork, concrete mixed in RMC plant, transporting, placing, compacting, vibrating etc., complete all as specified and directed by the Engineer-in-Charge.
23Notes:-(i) Design mix shall be as per IS-456-2000 and max size of aggregate shall not exceed 20mm and the slump shall be 150 to 180mm.(ii) Reinforcement shall be measured and paid separately.(iii) Unit rate shall be deemed to include interalia for preliminary design mix, works test cubes as specified.(iv) Minimum cement content shall be 400 Kg/ Cu.m. of concrete for M40 (Piles) using Portland slag cement with minimum slag content of 50% (fifty percent) which ever is higher.(v) Admixture shall be added as per manufacturer instructions. The rate for Admixture Conplast SP-430 A2 or Equivalent shall be deemed to be included in the quoted rate.(vi) The unit rate shall be deemed to include carrying out non-destructive integrity test for 100% of the total number of piles as per IS 14893-2001 shall be done by GovernmentEngineering College / IIT Chennai in the presence of contractor and the test results shall be vetted by the same authorities. Cost of testing including in the quoted rates.(vii) In case at the time of mix design cement content is increased beyond minimum content givenno extra payment will be made.(viii) Standard manufactured cover blocks as per IS should be used, site cast cover blocks not be used.
24M&L for reinforced cement concrete of grade M-40 (Design mix using 20mm graded stone aggregate) using ready mix concrete including supply and mixing of admixtures, as infoundations, including rafts, footings, foundation beams, plinth beams, bases for columns, pile caps, suspended floor beams & slabs, plinth protection, basement slabs, under-reamed piles etc. using Portland slag cement and handling, conveyance, errection with alignment in true position complete all as specified and as directed by the Engineer-in-Charge.
25All as per item No. 22 here-in-before but as in columns, Pillars, piers, vertical bands, posts and struts etc complete.
26All as per item No. 22 here-in-before but as in floor beams, brace beams, roof beams, cantilevers, bressumers, middle beams, lintels over 1.5m span and lintel bands etc complete.
27All as per item No. 22 here-in-before butas in retaining wall, basement wall, perapet and railings exc. 60cm in height, newels, balustrade, wall and the like complete.
28M&L for reinforced cement concrete pre cast beams of grade M-40 (Design mix using 20mm graded stone aggregate)using ready mix concrete including supply and mixing of admixtures, includes the feeding, mixing, moulds, formwork, shifting and placing of pre cast units, loading of item from stack yard, shifting to location and errection with alignment in true position complete all as specified and directed by the Engineer-in-Charge.
29All as per item No. 26 here-in-before but as in wall panels to compound wall complete.
30All as per item No. 26 here-in-before but as in columns to compound wall complete.
31Notes for item Nos. 22 to 28:(i) Minimum cement content shall be 400 Kg/Cu.m. of concrete for pile caps, suspended floor beams, slabs and footings, platform (Covered under item No. 22) and cement content shall be 360 Kg/Cu.m. of other concrete items for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered under item Nos. 23 to 28.(ii) Design mix shall be as per IS-456-2000.Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mmto 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes.(iv) Reinforcement shall be measured and paid for separately.(v) In case at the time of mix design cement content is increased beyond minimum content given above,no extra payment will be made.(vi) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks shall not be used
32Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut of level and disposal to distance of exc. 50 m but n. exc. 250 m and depositing where directed.
33M&L for Use and waste steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
34M&L for Use and waste steel formwork to sides, faces ofvertical walls, water tanks, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter and the likefor fair finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
35All as per item No. 31 here-in-before but to sides of pillars, posts, struts, columns, stanchions and the like complete.
36M&L forreinforcement in any situation usingCorrosion resistant TMT steel bars of grade Fe-500D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
37All as per item No. 33here-in-before 6mm dia and upto 8mm dia bars complete.Note for Item Nos. 33 & 34:- The lap length of reinforcement will be measured and paid under relavent items as per SSR/ IS
38M&L for providing and installing MS liner for bored cast-in-situ concrete piles with necessary stiffeners, driving shoe with continuous welding including cutting, bending welding etc. confirming to Fe 410-W (Gde E-250 Quality A) as per manufacturers instructions complete all as specified and as directed by the Engineer-in-Charge.Notes:-(i) Rate shall beinclusiveofcuttingthelineratcutofflevel. The rate is deemed to include for cutting, removal and salvage value of the material so obtained.(ii) MSlinershallbedrivenupto10m from cut off level.(iii) MS liner will be measured and paid up to the cut off level only of pile. Additional MS liner if used for convenience of construction shall be included in the rates quoted. Nothing extra shall be paid separately on this account.
39Supply and fix framed work as in doors or gates of angleor other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or othercovering, running rails and guides) and hanging; also fastening and fixing GdeE-165 (Fe-290) complete all as specified and as directed by the Engineer-in-charge.
40S&F mild steeljoist , channel, angle or tee sections fixed independently without connecting plates etc cut to length if required & confirming toFe 410-W (Gde E-250) quality B complete all as specified and as directed by the Engineer-in-charge.
41S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentconfirming to Fe-410-W (Gde E-250 quality B) complete all as specified and as directed by the Engineer-in-charge.
42S&F concertina coil fencing with punched tape concertina coil. 610mm dia 7 to 8 coils per running meter, upto 7m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00m apart and with horizontal R.B.T reinforced barbed wire, stud tied with GI staples and GI clips -to retain horizontal and including barbed wire 04 nos on each side of \"Y\" angle and 02 nos on vertical of \"Y\" angle, With necessary \"bolts or GI barbed wire tied to angle iron; with reinforced barbed tape (R.T.B)/ spring core thick wire of high tensile strength of 165kg/Sqmm with tape (0.52mm thick) and Weight 43.478gm/meter (cost of MS angle, CC blocks shall be paid separately) complete all as specified and as directed by the Engineer-in-charge.Note:-(i) After stretching the coil, the length of compound wall on which it has been stretched shall be measured as one RM.(ii) Provn of \"Y\" shaped MS angle shall be measured and paid separately.
43S&F PVC coated GI chain link fencing 100mmx100mm aperture,4mm dia including binding with MS round bar complete all as specified and directed by the Engineer-in-Charge.Note: MS round bar shall be measured and paid separately under relevant items
44Supply and Fix 25 mm thick bitumastic pad complete all as specified and as directed by the Engineer-in-Charge.
45M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over one coat of primer complete all as specified and as directed by the Engineer-in-charge.
46M&L forpreparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
47Total Amount in Figures
48Quoted Amount in Words

AI Tender Summary

OUR REF NO 46749380
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.75 Crore
LAST DATE 10-03-2025
Authority
Authority Name Military Engineer Services
Work Description Provision Of Compound Wall For Technical Buildings (Under Wp-12) At Naob, Rambilli Near Visakhapatnam Provision Of Compound Wall For Technical Buildings (Under Wp-12)
Basic Detail
Tender No DDG CE V TOKEN 08 OF 2023- 2024
Bidding Type Tender
Location
City rambilli
State Andhra Pradesh
Key Dates
Publish Date 20 Feb 2025
Submission Date 10 Mar 2025
Open Date 17 Mar 2025
Finance
Tender Value 39.75 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
18456f54-23e4-4afe-b61b-cf34f19cd96e.html
3449WP12CwallDrgs.pdf
3449WP12CwallIP.pdf
3449WP12CwallTender.pdf
BOQ_771331.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 20, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 17, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 03, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 10, 2025
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 10, 2025
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 10, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 17, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

18456f54-23e4-4afe-b61b-cf34f19cd96e.html

pdf

3449WP12CwallDrgs.pdf

pdf

3449WP12CwallIP.pdf

pdf

3449WP12CwallTender.pdf

xls

BOQ_771331.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender