| 1 | Safe carriage, loading-unloading with proper stacking of following materialfrom ESC-Daliganjto Work Site/JE -Dump Store |
| 2 | Cable HT XLPE 33 KV 3x300 Sqmm |
| 3 | Cable HT XLPE 11 KV 3x185 Sqmm |
| 4 | ACSR Dog Conductor |
| 5 | Cable Box O/D 33 KV 3x300 XLPE |
| 6 | Cable Box ST. Th. 33 KV 3x300 XLPE |
| 7 | STP 11 Mtr Long |
| 8 | Disc Insulator (B&S Type) 70 KN 33 KV |
| 9 | 11 KV Cable Box I/D 3x185 Sqmm XLPE |
| 10 | 11 KV Cable Box O/D 3x185 Sqmm XLPE |
| 11 | Cable Box ST. Th. 11 KV 3x185 XLPE |
| 12 | Laying of 11 kV 3x185 Sq. mm Single circuit in normal soil by digging of trench of size 900 mm deep 500 mm wide.The cable will be laid in between two rows of first class bricks after spreading 3” local sand at the bottom of the trench and packing of cable with local sand from each side and covered with bricks (Only cable will be provided by the department). |
| 13 | Hoisting of 33 KV 3x300Sq. Mm XLPE cable on existing pole. Cable will be passed through GI Pipe 6 inch Dia. (All the materials will be arranged by the contractor). |
| 14 | High Pressure testing of 11 KV 3x185 sqmm. XLPE cable with DC voltage at 18 KV with hold up to 5 minutes.(All the material will be arranged by the contractor). |
| 15 | Laying of 33 kV 3x185 Sq. mm Single circuit in normal soil by digging of trench of size 900 mm deep 500 mm wide.The cable will be laid in between two rows of first class bricks after spreading 3” local sand at the bottom of the trench and packing of cable with local sand from each side and covered with bricks (Only cable will be provided by the department). |
| 16 | Hoisting of 11 KV 3x185Sq. Mm XLPE cable on existing pole. Cable will be passed through GI Pipe 6 inch Dia. (All the materials will be arranged by the contractor). |
| 17 | High Pressure testing of 33 KV 3x300 sqmm. XLPE cable with DC voltage at 18 KV with hold up to 5 minutes.(All the material will be arranged by the contractor). |
| 18 | Stringing of ACSR Dog Conductor. All the materials supplied by contractor except ACSR Dog Conductor) |
| 19 | Fabrication erection of substation type Double pole structure on 11 Mtr long ST pole including mounting of one no. top channel of size 100x50 mm 2.25m, 01 nos. dropper angle with clams and nut bolts, with fixing of necessary clamps, accessories required, grouting in 1:4:8 cement sand, brick ballast and making of plinth 300mm above ground level. The pole will be planted on the stone pad of size 300x300x7.5 mm ST pole shall be supplied by the deptt. |
| 20 | Earthing of 11 ST poles as per RESPO norms. (All the materials supplied by contractor) |
| 21 | Supply & Fixing of 11 KV RMU (Three Way RMU with 02 No LBS and 01 Breaker) with proper fencing, earthing & grouting.(All the material will be arranged by the contractor). |
| 22 | Fixing of of following Materials |
| 23 | Cable Box O/D 33 KV 3x300 XLPE |
| 24 | Cable Box ST. Th. 33 KV 3x300 XLPE |
| 25 | Disc Insulator (B&S Type) 70 KN 33 KV |
| 26 | 11 KV Cable Box I/D 3x185 Sqmm XLPE |
| 27 | 11 KV Cable Box O/D 3x185 Sqmm XLPE |
| 28 | Cable Box ST. Th. 11 KV 3x185 XLPE |
| 29 | Supply & Fixing of HDPE Pipe |