Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #46718301

Tender For Special Repair/ Replacement Of Pipeline Ci Line To Di Line (Phase-Ii) At Af Stn Awantipur

Issued by Statutory Bodies & Commissions/Committees · Srinagar, Jammu And Kashmir
Tender Value
29.08 Lakhs
Estimated cost
Bid Submission
13 Jan 2025
0 days left
EMD
58160
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu And Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair/ Replacement Of Pipeline Ci Line To Di Line (Phase-Ii) At Af Stn Awantipur; 1 Taking up U/S CI water main(incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 100 mm bore for laying /rerouting of serviceable pipe after cleaning, complete all as specified and directed. 2 All as per item 1 above but 150 mm dia bore, complete all as specified and directed. 3 M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 100 mm with Spigot & Socket end, Class K-7 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) with Ethylene Propylene Diene Monomer (EPDM) rubber gasket conforming to IS:5382 of Bulb-Type-2 as per IS:5382; Heel- Type-5, as per IS:5382 will be supplied. Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. 4 All as per item 3 above but 150 mm dia bore, complete all as specified and directed. 5 M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 150 mm with welded flanged ends, Class K-9 conforming to IS: 8329/2000 with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000), with rubber gasket nut bolts washers complete 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. Excavation work shall be carried out in civil land necessary permission has to be accorded by contractor. No other payments shall be paid on this account. Work may be carried out on any terrain or inclinations. 6 Buring out lead joint in position, including removing old lead of size 100 mm bore, complete all as specified and directed. 7 Buring out lead joint in position, including removing old lead of size 150 mm bore, complete all as specified and directed. 8 Buring out lead joint in position, including removing old lead of following size 200 mm bore, complete all as specified and directed. 9 M&Lfor run laid laid joint for follwing size of CI pipe of size 100 mm bore, complete all as specified and directed. 10 M&Lfor run laid laid joint for follwing size of CI pipe of size150 mm bore, complete all as specified and directed. 11 M&Lfor run laid laid joint for follwing size of CI pipe of size200 mm bore, complete all as specified and directed. 12 M&Lfor ruber gasket joint/ tyton jointfor DI pipe of size100 mm bore, complete all as specified and directed. 13 M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 150 mm bore. Complete all as specified and as directed. 14 M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 200 mm bore, complete all as specified and directed. 15 Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed. 16 Taking down carefully cast iron sluice valve of size 150 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed. 17 Taking down carefully cast iron sluice valve of size 100 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed. 18 Taking down carefully cast iron sluice valve of size 80 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed. 19 M&L for painting of Valve Chamber plastered portion with cement base and steel portion with synthetic enamel paint of any size, complete all as specified and as directed. 20 Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm bore from 80 mm bore, complete all as specified and as directed. 21 S&F Cast iron gate sluice valve of size 100 mm dia Stainless steel stemPN- 1.6 (Flanged) conforming to IS 14846 hand wheel operated, complete all as specified and as directed. 22 All as per Item No 21 Above but 150 mm dia, complete all as specified and as directed. 23 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 15 mm dia, complete all as specified and as directed. 24 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 20 mm dia, all as specified and directed. 25 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 25 mm dia, all as specified and directed. 26 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 40 mm dia, all as specified and directed. 27 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 50 mm dia, all as specified and directed. 28 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 80 mm dia, all as specified and directed. 29 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 100 mm dia, all as specified and directed. 30 Supply and laying of galvanised steel water tubing medium grade (in replacement) trenches/ wall/ floor with all fittings, including connections such as union elbow, GI sockets, GI Unions, reducer, Tees or any connected accessories as required at site of size 15 mm bore, complete all as specified and as directed. 31 All as per Item No 30 Above butBore of pipe 20 mm, complete all as specified and as directed. 32 All as per Item No 30 Above butBore of pipe 25 mm, complete all as specified and as directed. 33 All as per Item No 30 Above but Bore of pipe 40mm, complete all as specified and as directed. 34 All as per Item No 30 Above but Bore of pipe 50mm, complete all as specified and as directed. 35 All as per Item No 30 Above but Bore of pipe 80mm, complete all as specified and as directed. 36 All as per Item No 30 Above but Bore of pipe 100mm, complete all as specified and as directed. 37 S&F gun metal globe valve (in replacement) with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and as directed. Make:- Zoloto, Audcu, L&T 38 All as per Item No 37 Above butBore of pipe 20mm, complete all as specified and as directed. 39 All as per Item No 37 Above butBore of pipe 25mm, complete all as specified and as directed. 40 All as per Item No 37 Above but Bore of pipe 40mm, complete all as specified and as directed. 41 All as per Item No 37 Above but Bore of pipe 50mm, complete all as specified and as directed. 42 Taking out existing U/S NRV of size 80-150 mm bore, complete all as specified and as directed. 43 Suply and fixing cast iron NRV flanged end of size 150 mm dia with all fitting and accessories, complete all as specified and as directed. 44 All as per item 43 above but 100 mm dia, complete all as specified and as directed. 45 All as per item 43 above but 80 mm dia, complete all as specified and as directed. 46 M&L for construction of valve chambers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame40x40x6 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface, complete all as specified and as directed.Note:- Brick work, PCC, Earthwork, Plaster, Pointing, Steel work is included in this item. 47 M&L for cement concrete PCC 1:2:4 type B1 in plain cement concrete 20 mm graded coarse aggregate, complete all as specified and as directed. 48 M&L for road cutting and making good the same by PCC 1:2:4 or bitumen, complete all as specified and as directed 49 M&L for excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and width and getting out, complete all as specified and as directed by Engr-in-Charge. 50 M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge. 51 M&L for removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge. 52 M&L for Lagging of exposed pipe by providing all around of pipe 40 mm thick bounded mineral wool performed SNAPON pipe section of density 144 Kg/M3 conforming to IS-9842,covered completely by chicken mesh net 25 guage 20mm mesh and reinforced with 1mm galvanised wire applied spirally @15cm centre to centre and providing 5mm thick smooth evenly. Plaster layers of composition consisting of 85% magnesia asbestos and plaster of paris mortar 1:6 of required strength to suit exposed weather condition under sub zero temperature for 15mm dia pipe, complete all as specified and as directed by Engr-in-Charge. 53 All as per Srl item No. 52 above, but size 20 mm dia, complete all as specified and as directed by Engr-in-Charge. 54 All as per srl item No. 52 above, but size 25 mm dia, complete all as specified and as directed by Engr-in-Charge. 55 All as per Srl item No. 52 above, but size 40 mm dia, complete all as specified and as directed by Engr-in-Charge. 56 M&L DI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross (all socket and spiogat collars caps and plug for the pipe socket & spigot of the following size upto 150 mm dia, complete all as specified and as directed.(Note:- Work includes lead /gasket for fitting of necessary size) 57 Note:-An amount of Rs.4,31,400.00 on account of credit schdule for Sch A Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Jan-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-Jan-2025

BOQ

Name of Work: SPECIAL REPAIR/ REPLACEMENT OF PIPELINE CI LINE TO DI LINE (PHASE-II) AT AF STN AWANTIPUR
Sl. No. Item Description
1Taking up U/S CI water main(incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 100 mm bore for laying /rerouting of serviceable pipe after cleaning, complete all as specified and directed.
2All as per item 1 above but 150 mm dia bore, complete all as specified and directed.
3M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 100 mm with Spigot & Socket end, Class K-7 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) with Ethylene Propylene Diene Monomer (EPDM) rubber gasket conforming to IS:5382 of Bulb-Type-2 as per IS:5382; Heel- Type-5, as per IS:5382 will be supplied. Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site.
4All as per item 3 above but 150 mm dia bore, complete all as specified and directed.
5M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 150 mm with welded flanged ends, Class K-9 conforming to IS: 8329/2000 with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000), with rubber gasket nut bolts washers complete 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. Excavation work shall be carried out in civil land necessary permission has to be accorded by contractor. No other payments shall be paid on this account. Work may be carried out on any terrain or inclinations.
6Buring out lead joint in position, including removing old lead of size 100 mm bore, complete all as specified and directed.
7Buring out lead joint in position, including removing old lead of size 150 mm bore, complete all as specified and directed.
8Buring out lead joint in position, including removing old lead of following size 200 mm bore, complete all as specified and directed.
9M&Lfor run laid laid joint for follwing size of CI pipe of size 100 mm bore, complete all as specified and directed.
10M&Lfor run laid laid joint for follwing size of CI pipe of size150 mm bore, complete all as specified and directed.
11M&Lfor run laid laid joint for follwing size of CI pipe of size200 mm bore, complete all as specified and directed.
12M&Lfor ruber gasket joint/ tyton jointfor DI pipe of size100 mm bore, complete all as specified and directed.
13M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 150 mm bore. Complete all as specified and as directed.
14M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 200 mm bore, complete all as specified and directed.
15Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed.
16Taking down carefully cast iron sluice valve of size 150 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed.
17Taking down carefully cast iron sluice valve of size 100 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed.
18Taking down carefully cast iron sluice valve of size 80 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed.
19M&L for painting of Valve Chamber plastered portion with cement base and steel portion with synthetic enamel paint of any size, complete all as specified and as directed.
20Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm bore from 80 mm bore, complete all as specified and as directed.
21S&F Cast iron gate sluice valve of size 100 mm dia Stainless steel stemPN- 1.6 (Flanged) conforming to IS 14846 hand wheel operated, complete all as specified and as directed.
22All as per Item No 21 Above but 150 mm dia, complete all as specified and as directed.
23Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 15 mm dia, complete all as specified and as directed.
24Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 20 mm dia, all as specified and directed.
25Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 25 mm dia, all as specified and directed.
26Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 40 mm dia, all as specified and directed.
27Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 50 mm dia, all as specified and directed.
28Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 80 mm dia, all as specified and directed.
29Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 100 mm dia, all as specified and directed.
30Supply and laying of galvanised steel water tubing medium grade (in replacement) trenches/ wall/ floor with all fittings, including connections such as union elbow, GI sockets, GI Unions, reducer, Tees or any connected accessories as required at site of size 15 mm bore, complete all as specified and as directed.
31All as per Item No 30 Above butBore of pipe 20 mm, complete all as specified and as directed.
32All as per Item No 30 Above butBore of pipe 25 mm, complete all as specified and as directed.
33All as per Item No 30 Above but Bore of pipe 40mm, complete all as specified and as directed.
34All as per Item No 30 Above but Bore of pipe 50mm, complete all as specified and as directed.
35All as per Item No 30 Above but Bore of pipe 80mm, complete all as specified and as directed.
36All as per Item No 30 Above but Bore of pipe 100mm, complete all as specified and as directed.
37S&F gun metal globe valve (in replacement) with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and as directed. Make:- Zoloto, Audcu, L&T
38All as per Item No 37 Above butBore of pipe 20mm, complete all as specified and as directed.
39All as per Item No 37 Above butBore of pipe 25mm, complete all as specified and as directed.
40All as per Item No 37 Above but Bore of pipe 40mm, complete all as specified and as directed.
41All as per Item No 37 Above but Bore of pipe 50mm, complete all as specified and as directed.
42Taking out existing U/S NRV of size 80-150 mm bore, complete all as specified and as directed.
43Suply and fixing cast iron NRV flanged end of size 150 mm dia with all fitting and accessories, complete all as specified and as directed.
44All as per item 43 above but 100 mm dia, complete all as specified and as directed.
45All as per item 43 above but 80 mm dia, complete all as specified and as directed.
46M&L for construction of valve chambers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame40x40x6 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface, complete all as specified and as directed.Note:- Brick work, PCC, Earthwork, Plaster, Pointing, Steel work is included in this item.
47M&L for cement concrete PCC 1:2:4 type B1 in plain cement concrete 20 mm graded coarse aggregate, complete all as specified and as directed.
48M&L for road cutting and making good the same by PCC 1:2:4 or bitumen, complete all as specified and as directed
49M&L for excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and width and getting out, complete all as specified and as directed by Engr-in-Charge.
50M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge.
51M&L for removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
52M&L for Lagging of exposed pipe by providing all around of pipe 40 mm thick bounded mineral wool performed SNAPON pipe section of density 144 Kg/M3 conforming to IS-9842,covered completely by chicken mesh net 25 guage 20mm mesh and reinforced with 1mm galvanised wire applied spirally @15cm centre to centre and providing 5mm thick smooth evenly. Plaster layers of composition consisting of 85% magnesia asbestos and plaster of paris mortar 1:6 of required strength to suit exposed weather condition under sub zero temperature for 15mm dia pipe, complete all as specified and as directed by Engr-in-Charge.
53All as per Srl item No. 52 above, but size 20 mm dia, complete all as specified and as directed by Engr-in-Charge.
54All as per srl item No. 52 above, but size 25 mm dia, complete all as specified and as directed by Engr-in-Charge.
55All as per Srl item No. 52 above, but size 40 mm dia, complete all as specified and as directed by Engr-in-Charge.
56M&L DI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross (all socket and spiogat collars caps and plug for the pipe socket & spigot of the following size upto 150 mm dia, complete all as specified and as directed.(Note:- Work includes lead /gasket for fitting of necessary size)
57Note:-An amount of Rs.4,31,400.00 on account of credit schdule for Sch \"A\" Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.

AI Tender Summary

OUR REF NO 46718301
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.08 Lakhs
LAST DATE 13-01-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair/ Replacement Of Pipeline Ci Line To Di Line (Phase-Ii) At Af Stn Awantipur; 1 Taking up U/S CI water main(incl all fitting) with spigot & socket /MS pipe or any other type of pipe or lead joint incl burning out joint & recovering lead from pipe of 100 mm bore for laying /rerouting of serviceable pipe after cleaning, complete all as specified and directed. 2 All as per item 1 above but 150 mm dia bore, complete all as specified and directed. 3 M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 100 mm with Spigot & Socket end, Class K-7 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) with Ethylene Propylene Diene Monomer (EPDM) rubber gasket conforming to IS:5382 of Bulb-Type-2 as per IS:5382; Heel- Type-5, as per IS:5382 will be supplied. Pursuant to clause 15.5.1 of IS8329, 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. 4 All as per item 3 above but 150 mm dia bore, complete all as specified and directed. 5 M&L for laying of Centrifugally Cast (Spun) Ductile Iron Pressure Pipes 150 mm with welded flanged ends, Class K-9 conforming to IS: 8329/2000 with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on external surfaces . The standard lengths of the pipes are 5.5 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000), with rubber gasket nut bolts washers complete 10% of pipes in each size, may be supplied in shorter lengths on surface/ over masonary pillar and connection to old or new position, complete all as specified and directed. Note: DI fitting /lead joint / Tyton joint will be measured and paid seperately all the dismanted / demolished /taking down material shall be reused or removed from site. Excavation work shall be carried out in civil land necessary permission has to be accorded by contractor. No other payments shall be paid on this account. Work may be carried out on any terrain or inclinations. 6 Buring out lead joint in position, including removing old lead of size 100 mm bore, complete all as specified and directed. 7 Buring out lead joint in position, including removing old lead of size 150 mm bore, complete all as specified and directed. 8 Buring out lead joint in position, including removing old lead of following size 200 mm bore, complete all as specified and directed. 9 M&Lfor run laid laid joint for follwing size of CI pipe of size 100 mm bore, complete all as specified and directed. 10 M&Lfor run laid laid joint for follwing size of CI pipe of size150 mm bore, complete all as specified and directed. 11 M&Lfor run laid laid joint for follwing size of CI pipe of size200 mm bore, complete all as specified and directed. 12 M&Lfor ruber gasket joint/ tyton jointfor DI pipe of size100 mm bore, complete all as specified and directed. 13 M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 150 mm bore. Complete all as specified and as directed. 14 M&Lfor ruber gasket joint/ tyton jointfor DI pipe upto size 200 mm bore, complete all as specified and directed. 15 Taking down carefully cast iron sluice valve of size 200 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed. 16 Taking down carefully cast iron sluice valve of size 150 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and directed. 17 Taking down carefully cast iron sluice valve of size 100 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed. 18 Taking down carefully cast iron sluice valve of size 80 mm bore from CI water mains, dismantling parts and reassembling, replacement of stainless spindle for sluice valve, class PN 1.0, and repacking stuffing box of sluice valve spindle, refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc., complete all as specified and as directed. 19 M&L for painting of Valve Chamber plastered portion with cement base and steel portion with synthetic enamel paint of any size, complete all as specified and as directed. 20 Taking out existing U/S CI sluice valve of any size any pattern up to 200 mm bore from 80 mm bore, complete all as specified and as directed. 21 S&F Cast iron gate sluice valve of size 100 mm dia Stainless steel stemPN- 1.6 (Flanged) conforming to IS 14846 hand wheel operated, complete all as specified and as directed. 22 All as per Item No 21 Above but 150 mm dia, complete all as specified and as directed. 23 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 15 mm dia, complete all as specified and as directed. 24 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 20 mm dia, all as specified and directed. 25 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 25 mm dia, all as specified and directed. 26 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 40 mm dia, all as specified and directed. 27 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 50 mm dia, all as specified and directed. 28 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 80 mm dia, all as specified and directed. 29 Taking up or down GI tubing and connection fixed to wall or laid in trenches of size 100 mm dia, all as specified and directed. 30 Supply and laying of galvanised steel water tubing medium grade (in replacement) trenches/ wall/ floor with all fittings, including connections such as union elbow, GI sockets, GI Unions, reducer, Tees or any connected accessories as required at site of size 15 mm bore, complete all as specified and as directed. 31 All as per Item No 30 Above butBore of pipe 20 mm, complete all as specified and as directed. 32 All as per Item No 30 Above butBore of pipe 25 mm, complete all as specified and as directed. 33 All as per Item No 30 Above but Bore of pipe 40mm, complete all as specified and as directed. 34 All as per Item No 30 Above but Bore of pipe 50mm, complete all as specified and as directed. 35 All as per Item No 30 Above but Bore of pipe 80mm, complete all as specified and as directed. 36 All as per Item No 30 Above but Bore of pipe 100mm, complete all as specified and as directed. 37 S&F gun metal globe valve (in replacement) with iron handle screwed both ends for iron pipe and fixed of size 15 mm bore, complete all as specified and as directed. Make:- Zoloto, Audcu, L&T 38 All as per Item No 37 Above butBore of pipe 20mm, complete all as specified and as directed. 39 All as per Item No 37 Above butBore of pipe 25mm, complete all as specified and as directed. 40 All as per Item No 37 Above but Bore of pipe 40mm, complete all as specified and as directed. 41 All as per Item No 37 Above but Bore of pipe 50mm, complete all as specified and as directed. 42 Taking out existing U/S NRV of size 80-150 mm bore, complete all as specified and as directed. 43 Suply and fixing cast iron NRV flanged end of size 150 mm dia with all fitting and accessories, complete all as specified and as directed. 44 All as per item 43 above but 100 mm dia, complete all as specified and as directed. 45 All as per item 43 above but 80 mm dia, complete all as specified and as directed. 46 M&L for construction of valve chambers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work 150 mm thickPCC 1:4:8 Type D2 as in foundation, PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4,and angle iron frame40x40x6 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface, complete all as specified and as directed.Note:- Brick work, PCC, Earthwork, Plaster, Pointing, Steel work is included in this item. 47 M&L for cement concrete PCC 1:2:4 type B1 in plain cement concrete 20 mm graded coarse aggregate, complete all as specified and as directed. 48 M&L for road cutting and making good the same by PCC 1:2:4 or bitumen, complete all as specified and as directed 49 M&L for excavation in trenches in soft/loose soil not exceeding 1.5 m in depth and width and getting out, complete all as specified and as directed by Engr-in-Charge. 50 M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge. 51 M&L for removal of excess soil from site n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge. 52 M&L for Lagging of exposed pipe by providing all around of pipe 40 mm thick bounded mineral wool performed SNAPON pipe section of density 144 Kg/M3 conforming to IS-9842,covered completely by chicken mesh net 25 guage 20mm mesh and reinforced with 1mm galvanised wire applied spirally @15cm centre to centre and providing 5mm thick smooth evenly. Plaster layers of composition consisting of 85% magnesia asbestos and plaster of paris mortar 1:6 of required strength to suit exposed weather condition under sub zero temperature for 15mm dia pipe, complete all as specified and as directed by Engr-in-Charge. 53 All as per Srl item No. 52 above, but size 20 mm dia, complete all as specified and as directed by Engr-in-Charge. 54 All as per srl item No. 52 above, but size 25 mm dia, complete all as specified and as directed by Engr-in-Charge. 55 All as per Srl item No. 52 above, but size 40 mm dia, complete all as specified and as directed by Engr-in-Charge. 56 M&L DI bend any type radius and angle tapers any type straght bend increacing decreacing or double socket etc) tee pipe single branch y juction double branch cross (all socket and spiogat collars caps and plug for the pipe socket & spigot of the following size upto 150 mm dia, complete all as specified and as directed.(Note:- Work includes lead /gasket for fitting of necessary size) 57 Note:-An amount of Rs.4,31,400.00 on account of credit schdule for Sch A Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
Basic Detail
Tender No GE (AF) AWA-55/2024-25
Bidding Type Tender
Location
City Srinagar
State Jammu And Kashmir
Key Dates
Publish Date 06 Jan 2025
Submission Date 13 Jan 2025
Open Date 15 Jan 2025
Finance
Tender Value 29.08 Lakhs
Tender Fee 500
EMD 58160
Exemption Available
Document List
cca8cd59-0adf-4653-bfc3-9a34b7a50694.html
BOQ_771079.xls
Tender55.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 06, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 13, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 13, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 15, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

cca8cd59-0adf-4653-bfc3-9a34b7a50694.html

xls

BOQ_771079.xls

pdf

Tender55.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender