| 1 | Supply, laying, jointing and testingin repairs XPLE insulated, armoured heavy duty electirc cable with aluminium conductor, 1100 volts grade, cross-sectionalarea 50 Sqmm 3.5 core in trenches, through pipe, under culvert or in air complete using existing cable cushioning and cable protection complete all as specified and directed. |
| 2 | All as per item Ser No 01 above but 95 Sqmm 3.5 Core |
| 3 | All as per item Ser No 01 above but 120 Sqmm 3.5 Core |
| 4 | All as per item Ser No 01 above but 150 Sqmm 3.5 Core |
| 5 | All as per item Ser No 01 above but 185 Sqmm 3.5 Core |
| 6 | S&F in repairs LT Busbar panel board with 4 Pole 40A MCCB for street light, breaking capacity 16KA, outdoor type door cubical type, slopy roof front back both side opening, pedastal mounted overall size not less than 600 x 450 x 25mm, CPRI approved, IP-54 having independent compartment for bus bar, incoming feeder and each outgoing feeders dust and vermin proof and lockable, factory made fabricated out of 3.15mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with 4 Nos aluminium bus bar of 150 Amps rating for 3 phase and bus bar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supportedon epoxy insulators 01 set including necessary copper cables of suitable size for MCCB/ inter connections, common earth bus bar of GI strip 32 x 6mm at bottom with independent plates at bottom for each outgoing and incoming cables in cabel alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing all accessories :-NOTE :- (a) All MCCBs will be measured and paid separately under relevant item of this schedule.(b) Rates of interconnecting copper/ aluminium cable along with necessary copper/ aluminium lugs are inclusive in the quoted rate.(c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval/ Layout/ Drawing/ General arrangements for panel from AGE (I) prior to commencement of work.(d) Cost for connecting of existing old underground cable of any size/ type to new incoming/ outgoing terminals by cutting the required length. Addition/ altration and provision of necessary cable lugs, cable glands, nuts & bolts etc shall be included in the quoted rates. |
| 7 | Earthing complete with GI earth plate of size 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below normal ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, protection pipe 15mm dia light grade upto 7.5mtrand salt etc. and connected to earthing test point including dismantling of old unserviceable earthing and takingn out material, complete all as specified and directed including testing after completion. |
| 8 | S&F of MCCB 4 pole, current rating 40 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity of 16 KA at 415 V, 50 Hz, complete all as specified and directed. |
| 9 | All as per item No 08 above but 4 pole 200 Amps having breaking capacity 36 KA |
| 10 | All as per item No 08 above but 4 pole 160 Amps having breaking capacity 36 KA |
| 11 | All as per item No 08 above but 4 pole 100 Amps having breaking capacity 16 KA |
| 12 | Supply, fixing & laying in repair GI pipe light grade 50mm bore in trench, under floor, wall and on pole for cable protection, complete all as specified and directed. |
| 13 | Excavation in trenches, in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cables, erection of poles, stays etc. and getting out, complete all as specified and directed. |
| 14 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed. |
| 15 | Removal of excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point. |
| 16 | Sand cushioning to under ground cable using fine sand (8cm before & 15cm after laying of cable) complete all as specified and directed.NOTE :- Punned thickness shall be measured and paid. |
| 17 | Brick sub class \"B\" of standard size for protection of cable, brick laid across the cable all as specified. |
| 18 | Supply, installing, testing and commissioning street light distribution boards maximum load 6 KW, Digital 24 hour capacity, 230 volts, made out of CRCA sheet with front openable door fitted with necessary hinges, door locking by panel lock and provision for Pad locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & botls etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers, complete suitable for accomodating and including provision of following switchgears/ components :-(a) Incoming MCB 40 Amp SPN - 01 No.(b) 3 pole contactor 32 Amp - 01 No.(c) Timer switch digital type, 24 hour - 01 No.(d) Auto/ Manual selector switch - 01 No. |
| 19 | Supply and fixing in repairs LED street light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 20 | Supply and fixing in repairs LED street light fitting 90 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 21 | Supply and fixing in repairs LED street light fitting 120 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 22 | NOTE :-An amount of Rs. 44,097.00 on account of Credit Schedule for Schedule \"A\" Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |