Youth Affairs and Sports and Culture Statutory Bodies & Commissions/Committees Closing in 0 days TDR #46713895

Bids Are Invited For Supply, Installation, Testing And Commissioning Of Two-Way Full Range Passive Loudspeaker System Composed By Dual 6 Neodymium Magnet Direct Radiating 1.5-Inch Voice Coil Or Better And One Titanium Diaphragm Neodymium Magnet Tweeter

Issued by Statutory Bodies & Commissions/Committees · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jan 2025
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Bids Are invited for Supply, Installation, Testing and Commissioning of Two-way full range passive loudspeaker system composed by dual 6 neodymium magnet direct radiating 1.5-inch voice coil or better and one titanium diaphragm neodymium magnet tweeter with I-inch voice coil diameter or better, 400 W continuous power in musical program or better, 200W RMS Power or better, Nominal impedance 82 or better, Sensitivity SPL (1W/1m): 95 dB higher, Maximum SPL (continuous/1m): 121 dB or higher, Maximum SPL (peak/1m): 124 dB or higher, Crossover frequency 3k4 Hz, Frequency response (-10dB) 62 Hz-20 kHz or better, Directivity (-6dB) 70 (H) x 70° (V) or better, Multilayer birch plywood with high resistant black Polyurea Supply, Installation, Testing and Commissioning of Passive subwoofer composed by one direct radiating 3-inch voice coil, 12 subwoofer band- pass tuned enclosure or better, 1000 W continuous power in musical program or better, RMS Power: 500W or better, Nominal Impedance: 8 2 or better, SPL(1W/1m): 96 dB or better, Maximum SPL (continuous/1m)126 dB or better, Maximum SPL (peak/1m): 129 dB or better, Crossover frequency (recommended )80 Hz/90 Hz/100 Hz, Frequency Response (- 10dB): 38 Hz-130 Hz or better, Directivity (H x V) Omnidirectional or better, Multilayer birch plywood with high resistant black Polyurea coating or better all complete as per specification. Supply, Installation, Testing and Commissioning of Two Channel Amplifier High Dynamic Power technology or better, Class AB amplifier with 600+ 600 W @ Stereo 42 power output or better, Voltage Gain 32 dB or better, Input Sensitivity 1.25 V or better, Input Impedance 20k 2 or better, Slew Rate +/-12 V/us or better, Output Power (1 kHz 0.1% THD) or better, Stereo 82/350+350 W or better, Stereo 40/600+600 W or better, Stereo 22/850+850 W or better, Bridge 82/1200 W or better, Bridge 4 2/1700 W or better, Frequency Response 20 Hz-20 kHz (0/-1 dB) or better, Damping Factor (1 kHz @ 82): 300 or better, Crosstalk 60 dB or better, S/N Ratio (A-weighted): 104 dB (A) or better, Mains 220-240 V AC 50/60 Hz or better, Detachable front panel gives access to the limiters threshold adjust or better, as per specification. Total Quantity : 345

AI Tender Summary

OUR REF NO 46713895
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 07-01-2025
Authority
Authority Name Ministry Of Culture
Work Description Bids Are invited for Supply, Installation, Testing and Commissioning of Two-way full range passive loudspeaker system composed by dual 6 neodymium magnet direct radiating 1.5-inch voice coil or better and one titanium diaphragm neodymium magnet tweeter with I-inch voice coil diameter or better, 400 W continuous power in musical program or better, 200W RMS Power or better, Nominal impedance 82 or better, Sensitivity SPL (1W/1m): 95 dB higher, Maximum SPL (continuous/1m): 121 dB or higher, Maximum SPL (peak/1m): 124 dB or higher, Crossover frequency 3k4 Hz, Frequency response (-10dB) 62 Hz-20 kHz or better, Directivity (-6dB) 70 (H) x 70° (V) or better, Multilayer birch plywood with high resistant black Polyurea Supply, Installation, Testing and Commissioning of Passive subwoofer composed by one direct radiating 3-inch voice coil, 12 subwoofer band- pass tuned enclosure or better, 1000 W continuous power in musical program or better, RMS Power: 500W or better, Nominal Impedance: 8 2 or better, SPL(1W/1m): 96 dB or better, Maximum SPL (continuous/1m)126 dB or better, Maximum SPL (peak/1m): 129 dB or better, Crossover frequency (recommended )80 Hz/90 Hz/100 Hz, Frequency Response (- 10dB): 38 Hz-130 Hz or better, Directivity (H x V) Omnidirectional or better, Multilayer birch plywood with high resistant black Polyurea coating or better all complete as per specification. Supply, Installation, Testing and Commissioning of Two Channel Amplifier High Dynamic Power technology or better, Class AB amplifier with 600+ 600 W @ Stereo 42 power output or better, Voltage Gain 32 dB or better, Input Sensitivity 1.25 V or better, Input Impedance 20k 2 or better, Slew Rate +/-12 V/us or better, Output Power (1 kHz 0.1% THD) or better, Stereo 82/350+350 W or better, Stereo 40/600+600 W or better, Stereo 22/850+850 W or better, Bridge 82/1200 W or better, Bridge 4 2/1700 W or better, Frequency Response 20 Hz-20 kHz (0/-1 dB) or better, Damping Factor (1 kHz @ 82): 300 or better, Crosstalk 60 dB or better, S/N Ratio (A-weighted): 104 dB (A) or better, Mains 220-240 V AC 50/60 Hz or better, Detachable front panel gives access to the limiters threshold adjust or better, as per specification. Total Quantity : 345
Basic Detail
Tender No GEM/2024/B/5708831
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 16 Dec 2024
Submission Date 07 Jan 2025
Open Date 03 Jan 2025
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
doc00635220241214081408_2024-12-14-19-20-44_1d9908a38e7fdc01299e9373b9eade84.pdf
7251163_Boq_0.xlsx
5d27ec96-ad1c-4772-a44a-a7c60be10451.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 16, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 07, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 03, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

doc00635220241214081408_2024-12-14-19-20-44_1d9908a38e7fdc01299e9373b9eade84.pdf

xlsx

7251163_Boq_0.xlsx

pdf

5d27ec96-ad1c-4772-a44a-a7c60be10451.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders