| Sl. No. | Item Description |
| 1 | GENERAL SUMMARYNOTE: Schedule ‘A’ Part - I to XVII are prepriced by MES under Ser No. 2.00to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed in Schedule ‘A’ Part - I , inserted by MES. |
| 3 | Lumpsum price worked out by the contractor for “EARTHWORK & SITE CLEARANCE” as listed in Schedule ‘A’ Part - II , inserted by MES. |
| 4 | Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III, inserted by MES. |
| 5 | Lumpsum price worked out by the tenderer for \"INTERNAL WATER SUPPLY\"as listed in Schedule ‘A’ Part-IV, inserted by MES. |
| 6 | Lumpsum price worked out by the tenderer for \"ROAD, PATH AND HARD STANDING\" as listed in Schedule ‘A’ Part- V, inserted by MES. |
| 7 | Lumpsum price worked out by the tenderer for\"SEWAGE DISPOSAL\" as listed in Schedule ‘A’ Part- VI, inserted by MES. |
| 8 | Lumpsum price worked out by the tenderer for\"AREA DRAINAGE\" as listed in Schedule ‘A’ Part- VII, inserted by MES. |
| 9 | Lumpsum price worked out by the tenderer for \"EXTERNAL ELECTIRFICATION\" as listed in Schedule ‘A’ Part- VIII, inserted by MES. |
| 10 | Lumpsum price worked out by the tenderer for \"EXTERNAL WATER SUPPLY\" as listed in Schedule ‘A’ Part- IX, inserted by MES. |
| 11 | Lumpsum price worked out by the tenderer for \"FIRE FIGHTING\" as listed in Schedule ‘A’ Part- X, inserted by MES. |
| 12 | Lumpsum price worked out by the tenderer for \"WATER COOLER\" as listed in Schedule ‘A’ Part- XI, inserted by MES. |
| 13 | Lumpsum price worked out by the tenderer for \"HEATING, VENTILATION & AIR CONDITIONING\" as listed in Schedule ‘A’ Part- XII, inserted by MES. |
| 14 | Lumpsum price worked out by the tenderer for \"LIFT - PASSENGER & GOODS\" as listed in Schedule ‘A’ Part- XIII, inserted by MES. |
| 15 | Lumpsum price worked out by the tenderer for \"FIRE ALARM & PUBLIC ADDRESS SYSTEM\" as listed in Schedule ‘A’ Part- XIV, inserted by MES. |
| 16 | Lumpsum price worked out by the tenderer for \"LIGHTNING PROTECTION\" as listed in Schedule ‘A’ Part- XV, inserted by MES. |
| 17 | Lumpsum price worked out by the tenderer for \"CCTV SYSTEM\" as listed in Schedule ‘A’ Part- XVI, inserted by MES. |
| 18 | Lumpsum price worked out by the tenderer for \"DEMOLITION & DISMANTLING\" as listed in Schedule ‘A’ Part- XVII, inserted by MES. |
| 19 | Subtotal |
| 20 | NOTE:Schedule ‘A’ Part - XVIII (miscellaneous) arenot prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6. |
| 21 | INTERNAL ELECTRIFICATION |
| 22 | Supply and fixing of Industrial luminaire- 40W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size |
| 23 | Supply and fixing of Industrial luminaire- 20W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size |
| 24 | Supply and fixing of Surface mounted Round luminaire- 12W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size |
| 25 | Supply and fixing of Highbay luminaire - 120W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 26 | Supply and fixing of Highbay luminaire - 80W LED. complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 27 | Supply and fixing of Aviation lighting fixture complete in all respectwith all assories as required. |
| 28 | Supply and fixing of Fire Exit Sign (illuminated)with LED,with upto 3 Hrs Battery Backup.Exit Sign |
| 29 | Supply and fixing WALL FAN ( 450MM sweep) complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 30 | Supply and fixing Flameproof WALL FAN ( 450MM sweep) complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 31 | Supply and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts,with 200 Amps rated bus bar double door on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 32 | S&L Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 32 Amp MCB |
| 33 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray corrosion resistent polyester flame retardent (Galvanisation thickness not less than 50 microns) withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required of following sizes:- |
| 34 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 35 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 36 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 37 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 38 | 600 mm width X 75 mm depth X 2.0 mm thickness |
| 39 | 750 mm width X 75 mm depth X 2.0 mm thickness |
| 40 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 41 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 42 | Telephone socket outlet |
| 43 | RJ 45 cat 6 jack point |
| 44 | INTERNAL WATER SUPPLY |
| 45 | Providing and fixing white vitreouschina Floor mountedwatercloset of size 360x650x800 mm of approved shapeincluding providing and fixing vitreouschinacistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting, nuts, boltsand gasket etc complete. Make: Jaquar OPS-WHT-15751UFP ,Cistern-OPS-WHT-15201 |
| 46 | Providing & Fixing white vitreous china wash basin forundercounter mounting, specially fabricatedbrackets, painted white, Brass Tap, 32mm C.P.waste,connection pipe & rubber adopter for waste connection, complete including cutting and making good thewalls, wherever required Complete in all respect..Wash Basin : Jaquar -Cat No :- CNS-WHT-705 & 15mm C.P. brass tap (Make - Jaquar, FLR - 5011N) |
| 47 | Providing and fixing white vitreous china Battery based infrared sensor operated urinal of approx. size 485x 310 x 710 mm having pre & post flushing with water (250 ml &500 ml consumption ), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer- in- charge. Make: Jaquar -Cat No :- URS-WHT-13255 |
| 48 | Providing and fixing stainless steel sink with drain board withC.I. brackets, duly painted white 40mm C.P. waste,C.P. brass chain and rubber plug, rubberadapterfor waste connection complete including cuttingandmaking goodthe walls wherever required. Make - Jayana, Jupiter CAT No. - SBSD 11 (DX), Glossy |
| 49 | Providing and fixingBottle trap for wash basin with 25mm minimum water seal,complete including cutting and making good thewalls, wherever required Complete in all respect. Make - Jaquar, CAT No.- ALD-769L |
| 50 | Providing and Fixing ofP.V.C wasteFlexible pipe 40 mm dia for sink and Urinalincluding PVC waste fittings complete including cutting and making good thewalls, wherever required Complete in all respect. |
| 51 | Providing and Fixing C.P brass towel rail complete with C.P brass brackets fixed to wooden cleats with C.P. brass screws. Make - Jaquar (Continental), CAT No.- ACN-1101N |
| 52 | Providing & fixing uplasticised PVC connection pipe of 45 cm long and 15 mm bore with brass unions |
| 53 | Providingand fixing C.P. brass angle valve 15mm diafor basin mixer and gyser points of approved quality conforming to IS : 8931. Make - Jaquar, CAT No. - FON-40053 |
| 54 | Providing and fixing C.P brass toilet paper holder .Make :- Jaquar, CAT No.:- ACN-1155N |
| 55 | Providing & fixingLiquid soap containerof standard shapewith bracket of the same material with snap fitting of approved quality and colour. Make - Jaquar, CAT No.- CAN-1135N |
| 56 | Providing & fixing 15 mm bore Sink cock of approved quality and colour. Make - Jaquar, CAT No.- 5309N |
| 57 | Providing & fixingCP brass Health faucet with 1.5M S.S. Flexible Tube with wall hook including screws, nut, bolts, cutting wall/floor and making good the same whatever required Complete in all respect.Make :- Jaquar, Allied, CAT No.- ALD-573 |
| 58 | Providing and Fixing C.P. Brass bib cockincluding wall fange, connections, screws, nut, bolts, cutting wall/floor and making good the same whatever required Complete in all respect. Make - Jaquar, CAT No.- FLR 5037N |
| 59 | Providing & Fixing C.P. wall mount double Robe Hook fixed to wooden cleats with C.P. brass screws, cutting wall/floor and making good the same whatever required Complete in all respect. Make :-Jaquar, CAT No.- CAN-1161N |
| 60 | Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector Complete in all respect. Make MacAlpine Model No MAC 1 |
| 61 | Providing & Fixing hand drier of best quality, to be operated with 230 volts, single phase, with fully hygienic condition, with all accessories including cutting and making good the walls, wherever required. |
| 62 | Supply, installation , testing commissioning of PP 110 mm dia (Polyproplene) Mineral rainforced low noise Soil & Waste solution as per EN 12056 and DIN 1986-100, with density 1.9 g/cm3.Along with new patented blue seal elastomeric seal is made from EPDM (EN 681-1) PP mineral(Astolan) filled Low noise system should has a fire classification DIN 4102-B2/EN13501 . Product should have a chemical resistance of pH 2-12 and is a complete sound protection system according to DIN 4109. Sound levels of not more than 16DB(A) as per VDI 4100 at a flow rate of 4 l/s Fire Behavior - class D s3 do. As per EN 1350 1-1 and B2(Normal flammable) according to DIN 4102-1. Working temperature -20° to 90° in continuous flow. including with push fit rubber ring sockets all necessary fittings and specials such as Bends, junctions, offsets & vent cowl. Fixing at wall/ceiling level supported by rubber line bracket & hangers etc.(Make-Wavin) |
| 63 | Supply, installation , testing commissioning of PP (Polyproplene)40/50 mm OD Pipes Mineral rainforced low noise Soil & Waste solution as per EN 12056 and DIN 1986-100, with density 1.9 g/cm3.Along with new patented blue seal elastomeric seal is made from EPDM (EN 681-1) PP mineral(Astolan) filled Low noise system should has a fire classification DIN 4102-B2/EN13501 . Product should have a chemical resistance of pH 2-12 and is a complete sound protection system according to DIN 4109. Sound levels of not more than 16DB(A) as per VDI 4100 at a flow rate of 4 l/s Fire Behavior - class D s3 do. As per EN 1350 1-1 and B2(Normal flammable) according to DIN 4102-1. Working temperature -20° to 90° in continuous flow. including with push fit rubber ring sockets all necessary fittings and specials such as Bends, junctions, offsets & vent cowl. Fixing at wall/ceiling level supported by rubber line bracket & hangers etc. .(For Indirect waste/ Wash Basin/Floor Drain ) (Make-Wavin) |
| 64 | Providing and fixing Floor Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections . (110 mm inlet & 110 mm outlet Long ht) |
| 65 | Providing and fixing110 x 50mm Floor Drain / Plain Floor trap complete in all respects. |
| 66 | Providing and fixing clean out cap plug (FCO /COP ) 110 mm diafor cleaning of same material. (Make-Wavin) |
| 67 | ROAD PATH & HARD STANDING |
| 68 | M & L 150 mm thick (compacted thickness) WMM in two 75mm thick each layers with laying, sporeading (with paver finisher only) and compacting base course of graded stone aggregate and granular material confirming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each, consolidateed, incl pre-mixeing the material with water of OMC in mechanical mixer (Pug Mill), carrage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/base course and compacting with power vibratory roller to achieve the desired density complete as per MORT & H specification clause-406 incl all material, labour, machinery, lighting, guarding and maintenance of diversion . |
| 69 | EXTERNAL ELECTRIFICATION |
| 70 | HT 6.6KV/11KV Dual voltage HT VCB , 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA,overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp with and including following:-. |
| 71 | One (1) Nos. 6.6KV/ 11KV 630 Amps. 350MVA, 18.6kA for 1sec. Electrically/ manually operateddraw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. |
| 72 | One (1) Multifunction Meter showing all Electrical Paramater ie Volt, Ampere, kw, kVA, P.F., kWH etc. |
| 73 | One (1) digital type ammeter with 6.6KV/ 11kV Cast resin CTs for metering (50/25 /5-5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB. |
| 74 | One (1) voltmeter (0-15KV) with VSS. |
| 75 | One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue). |
| 76 | One (1) set of Red/ Green indicating lamp for close and open position. |
| 77 | One (1) No. amber indicating lamp for auto trip. |
| 78 | One (1) No. clear indicating lamp for trip circuit healthy. |
| 79 | One (1) blue indicating lamp for spring charged. |
| 80 | One (1) strip heater to prevent absorption of moisture. |
| 81 | One (1) set of 3 O/C + 1E/F (with High Set) Neumerical Relay with 3 Nos. 6.6KV/ 11kV Resin Cast CTs 50/25/5-5A, CL 10P10, 15VA. |
| 82 | Master Trip Relay. |
| 83 | Trip circuit supervision relay |
| 84 | One (1) No. Potential Transformer 6.6KV/11KV/√3/110/√3 100VA burden |
| 85 | One (1) set of 3Element 24V DC Aux. Relay with H/R flag for tripping of Transfomer Fault ie. OTI, WTI & Buchholz Tripping. |
| 86 | One (1) set of 3Element 24V DC Aux. Relay with H/R flag for Alarm of Transfomer Fault ie. OTI, WTI & Buchholz Alarm. |
| 87 | One (1) set of 8 Stage 24V DC Annunciator with builtin test/Accept/ Reset Push Button along with 24V DC Hooter. |
| 88 | Master Trip Relay. |
| 89 | 12 Window Annunciator |
| 90 | Auxiliary switch/relay, master trip, anti pumping relay Trip circuit supervision relayand other control relays etc. as per requirements. |
| 91 | Power Pack : |
| 92 | One (1) Set 230V A.C, / 24V DC, Battery Backup, Power Pack to operate atleast 5Nos. Operation without AC Supply. |
| 93 | 6.6KV/11KV DUAL VOLTAGE HT VCB ( Modification & providing VCB at IN-3 Existing substation for New Facility IMHF) |
| 94 | Note: -a)Do the site Visit to check the suitability at site.b) Make & Provide the necessory links for connction of new VCB. |
| 95 | HT 6.6KV/11KV Dual voltage , 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA,overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp with and including following:-. |
| 96 | One (1) Nos. 6.6KV/ 11KV 630 Amps. 350MVA, 18.6kA for 1sec. Electrically/ manually operateddraw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. |
| 97 | One (1) Multifunction Meter showing all Electrical Paramater ie Volt, Ampere, kw, kVA, P.F., kWH etc. |
| 98 | One (1) digital type ammeter with 6.6KV/ 11kV Cast resin CTs for metering (50/25 /5-5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB. |
| 99 | One (1) voltmeter (0-15KV) with VSS. |
| 100 | One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue). |
| 101 | One (1) set of Red/ Green indicating lamp for close and open position. |
| 102 | One (1) No. amber indicating lamp for auto trip. |
| 103 | One (1) No. clear indicating lamp for trip circuit healthy. |
| 104 | One (1) blue indicating lamp for spring charged. |
| 105 | One (1) strip heater to prevent absorption of moisture. |
| 106 | One (1) set of 3 O/C + 1E/F (with High Set) Neumerical Relay with 3 Nos. 6.6KV/ 11kV Resin Cast CTs 50/25/5-5A, CL 10P10, 15VA. |
| 107 | Master Trip Relay. |
| 108 | Trip circuit supervision relay |
| 109 | One (1) No. Potential Transformer 6.6KV/11KV/√3/110/√3 100VA burden |
| 110 | One (1) set of 3Element 24V DC Aux. Relay with H/R flag for tripping of Transfomer Fault ie. OTI, WTI & Buchholz Tripping. |
| 111 | One (1) set of 3Element 24V DC Aux. Relay with H/R flag for Alarm of Transfomer Fault ie. OTI, WTI & Buchholz Alarm. |
| 112 | One (1) set of 8 Stage 24V DC Annunciator with builtin test/Accept/ Reset Push Button along with 24V DC Hooter. |
| 113 | Master Trip Relay. |
| 114 | 12 Window Annunciator |
| 115 | Auxiliary switch/relay, master trip, anti pumping relay Trip circuit supervision relayand other control relays etc. as per requirements. |
| 116 | Power Pack : |
| 117 | One (1) Set 230V A.C, / 24V DC, Battery Backup, Power Pack to operate atleast 5Nos. Operation without AC Supply. |
| 118 | Supplying ,Assembling , erecting, testing and commissioning of 1500KVA 6.6KV-11KV/0.433KV Dual voltage 3phase 50Hz, indoor type copper wound, Dry type cast resin step down transformer complete with all modern fittings asgivenin the specifications including , lifting lugs, Roller type bi-directional wheels, suitable boxes on both the ends for cable entry & bus duct,winding temprature indication & alarm, earthing terminals, diagram and rating plat etc. as required with followins:- |
| 119 | 6.6KV-11KV/433V Dual voltage distribution transformer shall be a part of packaged substation which will be housed in the enclosure. The transformers shall be installed in hot, humid tropical atmosphere. All equipment accessories and wiring shall be provided with tropical finish to prevent fungus growth |
| 120 | The transformers shall be dry Type & capable of continuous operation of rated output under the operating conditions of voltage and frequency variations as per statutory limits governed by relevant Indian Standard and Indian Electricity Rules, 1956 / IEC with latest amendments in force. |
| 121 | Requirement: 6.6KV-11KV/433V Dual voltage dry type cast resin with OFF LOAD Tap Changer(OCTC), Tapping range +5% to -7.5% in steps of 2.5% (HV side), neutral air cooled, double copper wound, core type suitable for packaged substation housed in a enclosure. |
| 122 | Voltage Ratio: No load voltage 11000/433volts within tolerance as stipulated in latest IS standard. |
| 123 | Insulating material shall be of proven design. The insulating materials shall be class “F” |
| 124 | Rating: The transformer shall have a continuous rating as specified at any of the specified tapping position and with the maximum temperature rise specified. |
| 125 | Temperature Rise: The maximum temperature rise at the specified maximum continuous output shall not exceed 40°C by thermometer of winding above ambient temperature of 50°C. |
| 126 | Type of Load: The transformer shall be suitable for carrying unbalanced load up to 90% load within temperature rise indicated in the Indian Standard specification ‘Guide for loading of dry Transformer |
| 127 | Overloads: The transformers shall be suitable for carrying overload within temperature rise indicated in IS ‘Guide for Loading of dry transformer’. |
| 128 | Connections:H.V. Delta and L.V Star connected with neutral brought out on the secondary side for connection to earth; Vector group DYn11 of IS:2026 |
| 129 | Each 6.6KV-11KV/433V Dual voltage Step down transformers shall be provided with the following fittings and accessories: Rating diagram and terminal marking plate for transformer |
| 130 | Lifting lugs for transformer |
| 131 | Bi-directional Rollers |
| 132 | Rating diagram and terminal marking plate for transformer |
| 133 | Earth terminals (2 Nos) for body earthing for transformers |
| 134 | Inspection door for access to terminal connections for transformers |
| 135 | Suitable cable termination arrangement for M.V. side with extended Bus bars for cables or Bus duct connection and cable box terminations on H.V. Side, suitable for 3Cx 240/300sq. mm 11 K.V. XLPE Aluminum Conductor cable. |
| 136 | Necessary hardware, clamps, lugs etc. for terminations of H.V. Cables on HV side and cable termination on M.V. Side. |
| 137 | Winding temperature indicator with contacts for remote alarm and tripping. |
| 138 | SAFETY EQUIPMENTS |
| 139 | Supply & fixing of Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 9.0 Kgm). |
| 140 | Supply & fixing ofCarbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 4.5 Kgm). |
| 141 | Supply & fixing of G.I buckets of followings capacity paint and written with white paint Fire and mounted on M.S. angle iron bracket of sizes 50 mm x 50 mm x 6 mm thick and 500 mm long including grouting in wall etc. as required including filling with dry sand 9 ltr capacity. |
| 142 | Supply of First aid box as approved by St. John Ambulance Brigade/Indian Red Cross Conforming to IS:2217 - 1963. |
| 143 | Supply & fixing of Shock treatment chart at least in three languages duly mounted on a wooden frame with glass as required. |
| 144 | Supply of Elastomeric mat 2 mm thick to withstand 1.1KV dielectric strength as per IS 15652/2006. |
| 145 | MV DISTRIBUTION PANELS & BOARDS |
| 146 | Material & Labour for design, Supply, fabrication, Installation, testing & commitioning factory made, LT panel board 415 Volt AC 3 phase, 50Hz, indoor type, totally enclosed, dust & vermin proof, suitably ventilated, floor mounted, 415Volts, 3 phase & Neutral, 50Hz, AC supply system, fully compartmentalized, both side openable,fabricated out of 2 mm CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 with pre- treatment and powder coated of approved colour including suitable size of angle iron/ Flat iron, front opening type with provision of cable entry, with proper frrrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size ( minimum 1.5Sqmm), required civil works/ anchoring bolts for fixing, PCC foundation etc. with and including following:BUS BAR CHAMBER: Electricity grade copper shrouded busbar capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators and provision of exension. |
| 147 | Incomer:1500KVA Transformer rating |
| 148 | 1 No. 2500 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type,Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B.with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: |
| 149 | Digital flush type class-1.0 accuracy multifunction meter showing V, A,PF,KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 2500/5 ratio, 15 VA Class 1.0 metering. |
| 150 | 6 nos NO/NC contacts for remote opening & closing. |
| 151 | Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. |
| 152 | 1 set of three phase indicating lamps along with 2A SP MCB backup protection. |
| 153 | Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. |
| 154 | Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel |
| 155 | 24 V DC Shunt trip coil. |
| 156 | Motor wound spring closing mechanism. |
| 157 | Control MCB, control terminals& wiring as required. |
| 158 | 7 mode surge suppression with suitable rating fuses & base complete as required. |
| 159 | Restricted Earth fault relay with 3 Nos. current transformers of 2500/5 ratio, 15 VA Class 5P 10 |
| 160 | Undervoltage, Overvoltage & phase reversal relay for persisted voltage of 105-180% & 20-95% of rated voltage. |
| 161 | All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . |
| 162 | Incomer:750KVA DG set rating |
| 163 | 1 No. 1250 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type,Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B.with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: |
| 164 | Digital flush type class-1.0 accuracy multifunction meter showing V, A,PF,KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 1250/5 ratio, 15 VA Class 1.0 metering. |
| 165 | 6 nos NO/NC contacts for remote opening & closing. |
| 166 | Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. |
| 167 | 1 set of three phase indicating lamps along with 2A SP MCB backup protection. |
| 168 | Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. |
| 169 | Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel |
| 170 | 24 V DC Shunt trip coil. |
| 171 | Motor wound spring closing mechanism. |
| 172 | Control MCB, control terminals& wiring as required. |
| 173 | Restricted Earth fault relay with 3 Nos. current transformers of 2500/5 ratio, 15 VA Class 5P 10 |
| 174 | All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . |
| 175 | Bus Coupler: |
| 176 | 1 No. 25000 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type,Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B.with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: |
| 177 | 6 nos NO/NC contacts for remote opening & closing. |
| 178 | Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. |
| 179 | Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. |
| 180 | 24 V DC Shunt trip coil. |
| 181 | Motor wound spring closing mechanism. |
| 182 | Control MCB, control terminals& wiring as required. |
| 183 | All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . |
| 184 | Bus Bars: |
| 185 | A set ofTPN Aluminum bus bars rated for 3000A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (50kA) |
| 186 | Outgoings : |
| 187 | All outgoing shall have Ics = 50 KA (As per SLD) |
| 188 | 1 Nos. TPN feeder having 1600A TPN MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 189 | 2 Nos. TPN feeder having 1250A TPN MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 190 | 1 Nos. TPN feeder having 1000A TPN MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 191 | 1 Nos. TPN feeder having 630AMCCB, ON /OFF/ TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 192 | 2 Nos. TPN feeder having 400AMCCB, ON /OFF/ TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 193 | 1 Nos. TPN feeder having 250AMCCB, ON /OFF/ TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 194 | 9 Nos. TPN feeder having 100AMCCB, ON /OFF/ TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT\"s with control MCB. |
| 195 | 2 Nos. vacant space suitable for TPN feeder having 250AMCCB. |
| 196 | Other items such as |
| 197 | 1 Lot of control wiring |
| 198 | 1 Set of designation plates |
| 199 | MAIN LT PANEL Described as above. |
| 200 | Smart Hybrid Active Filter 500A AHF + 700 KVAr @ 440V Detuned Capacitor Bank |
| 201 | INDOOR DUTY |
| 202 | Design, Manufacturing, Supply, installation,Testing and commissioning of Smart Hybrid Active Filter to achieve Pf > 0.99 Lag and TDDi values within IEEE 519-2014 recommended limits. The degree of protection of enclosures system shall be IP30. The switching device of the active compensation system shall be IGBT based. The active compensation system specifications are mentioned below. The active compensation system should do the Pf correction as a 1st Priority and 2nd Priority as harmonics compensation (remaining capacity after Pf correction). Response time shall be 100 micro Sec or less. The passive part switching device shall be contactor based. The entire system should work in an integrated manner with a single controller. |
| 203 | Make: Inphase/ schnieder/ ABB |
| 204 | Technical specification : |
| 205 | Electrical Characteristics |
| 206 | Connection method -3‐Ph-3‐Wire System |
| 207 | Network Voltage - 415V |
| 208 | Permissible Voltage Variation +/-10% |
| 209 | Ampere Rating - 500A AHF |
| 210 | IGBT Connection Topology -3 Level Topology |
| 211 | System Frequency -50 Hz (+/- 5%) |
| 212 | Equipment Efficiency - 98% of the equipment power typically |
| 213 | Compensation Modes - Closed Loop |
| 214 | Reaction time - 0.1 ms (Instantaneous) |
| 215 | Response time - 1 ms |
| 216 | Harmonics Compensation - Resource Delivery from 3rdto 61stOrder Harmonics Compensation |
| 217 | Modularity - Maximum 32 units can be combined |
| 218 | Internal Protection- Main breaker |
| 219 | Programming/Communication Characteristics |
| 220 | Communications -Mod bus |
| 221 | Programming Interface -Using IPC Manager (7‐Inch Colour Touch Screen Graphical User Interface ‐ GUI) |
| 222 | Redundancy -Master/master arrangement |
| 223 | Reactive Power range- ‐100% inductive to +100% capacitive of the rated kVAr |
| 224 | Auxiliary PF Setting -Programmable as per the Site conditions |
| 225 | Target cos pi - Programmable from 0.6 (inductive) to 0.6 (capacitive) |
| 226 | Harmonics Selection - 20 Selectable Harmonics |
| 227 | Installation Aspects(Per unit) |
| 228 | Ingress Protection (IP) IP‐30 |
| 229 | Altitude - Up to 1000m |
| 230 | Ambient Temperature - 0 to +50°C (Derating after +40°C) |
| 231 | Humidity - Maximum 95% RH, Non‐condensing |
| 232 | Cooling Arrangements - Forced‐air cooling |
| 233 | CT Requirements - 3 CT\"s (class 1.0 or better) with sufficient VA Burden |
| 234 | SPECIAL FEATURES FOR LONGER LIFE OF ACTIVE PART |
| 235 | DC Capacitors Used in DC Link - FILM TYPE DC CAPACITORS |
| 236 | PWM Reactors - Foil Type reactors specially designed with Multiple Airgaps |
| 237 | INPUT FILTER - RC TANK as per requirement with Mandatory LCL Filter |
| 238 | Controller Design - Rugged Design with Multiple I/Os |
| 239 | IGBT Max Junction Temperature - 175 Degree Centigrade |
| 240 | Capacitor Panel Specification |
| 241 | Voltage Variation: +/-10% |
| 242 | Rated Frequency: 50 Hz (+/- 5%) |
| 243 | Capacitor Rated Voltage: 525V |
| 244 | Capacitor Output Voltage: 440V |
| 245 | Capacitor Unit Type: MPP Heavy Duty Capcaitor |
| 246 | Switching Device: Contactor Switched (AC-3) |
| 247 | Capacitor Panel KVAr - 700 KVAr @ 440V |
| 248 | Step Size with KVAR rating - (7 x 100KVAr) |
| 249 | Step protection Back-up Protection - Each step with MCCB protection |
| 250 | Ambient Condition - Indoor 10°C to 50°C, 60% Relative humidity, non-condensing |
| 251 | Reactor Rating: Detuned Series 14% reactor Aluminum wound with Class H insulation. |
| 252 | POWER DISTRIBUTION BOARDS & PANELS |
| 253 | Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor/ wall mounted, free standing extendible type power distribution boards/ Panels compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached with and including following:- |
| 254 | MAIN LIGHT & POWER PANEL (ELECTRICAL ROOM) |
| 255 | INCOMING: |
| 256 | 1 No. TPNIncomer feeder having 630A 4P MCCB (25kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 257 | BUSBAR: |
| 258 | One set of TPN, \"AL\" bus bar rated 800 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 259 | OUTGOINGS: MCCB Ics-25kA & MCB as per specified |
| 260 | 3 Nos. TPN feeder having 200ATPN MCCB, ONindication with MFM with all parameters & matching cast resin CT\"s & control MCB. |
| 261 | 2 Nos. TPN feeder having 160ATPN MCCB, ON indication with MFM with all parameters & matching cast resin CT\"s & control MCB. |
| 262 | 2 Nos. TPN feeder having 125ATPN MCCB, ONindication with MFM with all parameters & matching cast resin CT\"s & control MCB. |
| 263 | 4 Nos. TPN feeder having 100ATPN MCCB, ON indication with MFM with all parameters & matching cast resin CT\"s & control MCB. |
| 264 | 6Nos. TPN feeder having 63A TPN MCB \"C\" curve, ONindication with MFM with all parameters & matching cast resin CT\"s & control MCB. |
| 265 | Other items such as |
| 266 | 1 Lot of control wiring |
| 267 | 1 Set of designation plates |
| 268 | Complete panel Described as above. |
| 269 | FLOOR DISTRIBUTION BOARDS(FDB\"s) |
| 270 | Supplying, installation, testing & commissioning FDBs (floor distrubitin boards)of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type wall mounted extendible type power distribution boards/ Panels compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Copper Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. |
| 271 | FDB - 1 |
| 272 | INCOMING: |
| 273 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications. |
| 274 | BUSBAR: |
| 275 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 276 | OUTGOINGS: MCB as per specified |
| 277 | 3Nos. TPN feeder having 20A 4P MCB \"C\" |
| 278 | 1Nos. SPN feeder having 40A DP MCB \"C\" |
| 279 | 2Nos. TPN feeder having 40A 4P MCB \"C\" |
| 280 | 2Nos. SPN feeder having 63A DP MCB \"C\" |
| 281 | Other items such as |
| 282 | 1 Lot of control wiring |
| 283 | 1 Set of designation plates |
| 284 | Complete panel Described as above. |
| 285 | FDB - 2 |
| 286 | INCOMING: |
| 287 | 1 No. TPNIncomer feeder having63A 4P MCB (10kA) & ON/OFF indications. |
| 288 | BUSBAR: |
| 289 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 290 | OUTGOINGS: MCB as per specified |
| 291 | 1Nos. TPN feeder having 20A 4P MCB \"C\" |
| 292 | 2Nos. SPN feeder having 40A DP MCB \"C\" |
| 293 | 4Nos. TPN feeder having 40A 4P MCB \"C\" |
| 294 | Other items such as |
| 295 | 1 Lot of control wiring |
| 296 | 1 Set of designation plates |
| 297 | Complete panel Described as above. |
| 298 | FDB - 3 |
| 299 | INCOMING: |
| 300 | 1 No. TPNIncomer feeder having 125A 4P MCCB (18kA) & ON/OFF indications. |
| 301 | BUSBAR: |
| 302 | One set of TPN, \"CU\" bus bar rated 200 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 303 | OUTGOINGS: MCB as per specified |
| 304 | 2Nos. SPN feeder having 32A DP MCB \"C\" |
| 305 | 1Nos. SPN feeder having 40A DP MCB \"C\" |
| 306 | 3Nos. TPN feeder having 63A 4P MCB \"C\" |
| 307 | Other items such as |
| 308 | 1 Lot of control wiring |
| 309 | 1 Set of designation plates |
| 310 | Complete panel Described as above. |
| 311 | FDB - 4 |
| 312 | INCOMING: |
| 313 | 1 No. TPNIncomer feeder having63A 4P MCB (10kA) & ON/OFF indications. |
| 314 | BUSBAR: |
| 315 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 316 | OUTGOINGS: MCB as per specified |
| 317 | 4Nos. SPN feeder having 40A DP MCB \"C\" |
| 318 | 4Nos. TPN feeder having 40A 4P MCB \"C\" |
| 319 | 2Nos. SPN feeder having 63A DP MCB \"C\" |
| 320 | Other items such as |
| 321 | 1 Lot of control wiring |
| 322 | 1 Set of designation plates |
| 323 | Complete panel Described as above. |
| 324 | FDB - 5 |
| 325 | INCOMING: |
| 326 | 1 No. TPNIncomer feeder having63A 4P MCB (10kA) & ON/OFF indications. |
| 327 | BUSBAR: |
| 328 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 329 | OUTGOINGS: MCB as per specified |
| 330 | 4Nos. SPN feeder having 32A DP MCB \"C\" |
| 331 | 2Nos. SPN feeder having 40A DP MCB \"C\" |
| 332 | 4Nos. TPN feeder having 40A 4P MCB \"C\" |
| 333 | Other items such as |
| 334 | 1 Lot of control wiring |
| 335 | 1 Set of designation plates |
| 336 | Complete panel Described as above. |
| 337 | FDB - 6 |
| 338 | INCOMING: |
| 339 | 1 No. TPNIncomer feeder having63A 4P MCB (10kA) & ON/OFF indications. |
| 340 | BUSBAR: |
| 341 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 342 | OUTGOINGS: MCB as per specified |
| 343 | 3Nos. TPN feeder having 40A 4P MCB \"C\" |
| 344 | 3Nos. SPN feeder having 63A DP MCB \"C\" |
| 345 | Other items such as |
| 346 | 1 Lot of control wiring |
| 347 | 1 Set of designation plates |
| 348 | Complete panel Described as above. |
| 349 | FDB - 7 |
| 350 | INCOMING: |
| 351 | 1 No. TPNIncomer feeder having 200A 4P MCCB (18kA) & ON/OFF indications. |
| 352 | BUSBAR: |
| 353 | One set of TPN, \"CU\" bus bar rated 250 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 354 | OUTGOINGS: MCB as per specified |
| 355 | 9Nos. SPN feeder having 40A DP MCB \"C\" |
| 356 | 5Nos. TPN feeder having 40A 4P MCB \"C\" |
| 357 | 2Nos. TPN feeder having 63A 4P MCB \"C\" |
| 358 | Other items such as |
| 359 | 1 Lot of control wiring |
| 360 | 1 Set of designation plates |
| 361 | Complete panel Described as above. |
| 362 | FDB - 8 |
| 363 | INCOMING: |
| 364 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications. |
| 365 | BUSBAR: |
| 366 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 367 | OUTGOINGS: MCB as per specified |
| 368 | 1Nos. SPN feeder having 20A DP MCB \"C\" |
| 369 | 4Nos. SPN feeder having 32A DP MCB \"C\" |
| 370 | 7Nos. SPN feeder having 40A DP MCB \"C\" |
| 371 | 2Nos. TPN feeder having 40A 4P MCB \"C\" |
| 372 | Other items such as |
| 373 | 1 Lot of control wiring |
| 374 | 1 Set of designation plates |
| 375 | Complete panel Described as above. |
| 376 | FDB - 9 |
| 377 | INCOMING: |
| 378 | 1 No. TPNIncomer feeder having 125A 4P MCCB (18kA) & ON/OFF indications. |
| 379 | BUSBAR: |
| 380 | One set of TPN, \"CU\" bus bar rated 200 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 381 | OUTGOINGS: MCB as per specified |
| 382 | 2Nos. SPN feeder having 32A DP MCB \"C\" |
| 383 | 6Nos. SPN feeder having 40A DP MCB \"C\" |
| 384 | 3Nos. TPN feeder having 40A 4P MCB \"C\" |
| 385 | 1Nos. SPN feeder having 63A DP MCB \"C\" |
| 386 | Other items such as |
| 387 | 1 Lot of control wiring |
| 388 | 1 Set of designation plates |
| 389 | Complete panel Described as above. |
| 390 | FDB - 10 |
| 391 | INCOMING: |
| 392 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications. |
| 393 | BUSBAR: |
| 394 | One set of TPN, \"CU\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 395 | OUTGOINGS: MCB as per specified |
| 396 | 1Nos. SPN feeder having 32A DP MCB \"C\" |
| 397 | 1Nos. TPN feeder having 32A 4P MCB \"C\" |
| 398 | 3Nos. SPN feeder having 40A DP MCB \"C\" |
| 399 | 3Nos. TPN feeder having 40A 4P MCB \"C\" |
| 400 | Other items such as |
| 401 | 1 Lot of control wiring |
| 402 | 1 Set of designation plates |
| 403 | Complete panel Described as above. |
| 404 | FDB - 11 |
| 405 | INCOMING: |
| 406 | 1 No. TPNIncomer feeder having 160A 4P MCCB (18kA) & ON/OFF indications. |
| 407 | BUSBAR: |
| 408 | One set of TPN, \"CU\" bus bar rated 250 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 409 | OUTGOINGS: MCB as per specified |
| 410 | 2Nos. SPN feeder having 32A DP MCB \"C\" |
| 411 | 7Nos. SPN feeder having 40A DP MCB \"C\" |
| 412 | 7Nos. TPN feeder having 40A 4P MCB \"C\" |
| 413 | Other items such as |
| 414 | 1 Lot of control wiring |
| 415 | 1 Set of designation plates |
| 416 | Complete panel Described as above. |
| 417 | FDB - 12 |
| 418 | INCOMING: |
| 419 | 1 No. TPNIncomer feeder having 200A 4P MCCB (18kA) & ON/OFF indications. |
| 420 | BUSBAR: |
| 421 | One set of TPN, \"CU\" bus bar rated 250 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 422 | OUTGOINGS: MCB as per specified |
| 423 | 1Nos. SPN feeder having 32A DP MCB \"C\" |
| 424 | 4Nos. SPN feeder having 40A DP MCB \"C\" |
| 425 | 7Nos. TPN feeder having 40A 4P MCB \"C\" |
| 426 | 4Nos. SPN feeder having 63A DP MCB \"C\" |
| 427 | Other items such as |
| 428 | 1 Lot of control wiring |
| 429 | 1 Set of designation plates |
| 430 | Complete panel Described as above. |
| 431 | FDB - 13 |
| 432 | INCOMING: |
| 433 | 1 No. TPNIncomer feeder having 200A 4P MCCB (18kA) & ON/OFF indications. |
| 434 | BUSBAR: |
| 435 | One set of TPN, \"CU\" bus bar rated 250 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 436 | OUTGOINGS: MCB as per specified |
| 437 | 1Nos. SPN feeder having 32A DP MCB \"C\" |
| 438 | 10Nos. SPN feeder having 40A DP MCB \"C\" |
| 439 | 6Nos. TPN feeder having 40A 4P MCB \"C\" |
| 440 | 1Nos. SPN feeder having 63A DP MCB \"C\" |
| 441 | Other items such as |
| 442 | 1 Lot of control wiring |
| 443 | 1 Set of designation plates |
| 444 | Complete panel Described as above. |
| 445 | LT XLPE CABLES |
| 446 | Supply, laying, testing, commissioning of LT cables complete with end termination; Aluminium thimbles for aluminium conductor cables and copper thimbles for copper conductor cables of 1100 V grade aluminium / copper conductor (as specified below) extruded XLPE with insulated PVC innersheath, unarmoured / GI wire/tape armoured (as specified below) and outer PVC sheathed cable of IS- 7098 standard of following sizes in trenches, cable racks or trays or pipes, including supply of GI clamps and screws and providing aluminum cable tags at every 20 metres and at both termination points, including unloading and transportation of cables at site, unpacking, complete of following sizes:- |
| 447 | 3Corex6 sq. mm stranded copper conductor armoured cable |
| 448 | 4Corex4 sq. mm stranded copper conductor armoured cable |
| 449 | 4Corex6 sq. mm strandedcopper conductor armoured cable |
| 450 | 4Corex10 sq. mm stranded copper conductor armoured cable |
| 451 | Horizintal boring of size 200mm dia for laying passing of PVC insulated and PVC sheathed / XLPE power cable with supply & laying of 150mm HDPE pipe complete in all respect including removal earth/debrish to a distance exceeding 50mtr and not exc 100 mtr. |
| 452 | Supply, Installing & commissiong of micro processor /DSP controlled 20 KVA UPS,True Online Double Conversion VFI Technology UPS (High Frequency PWM using IGBT technology) , working in hot standby mode, 3 Phase input and 3 phase 415 V output UPS system; Power Factor 0.8 and each comprising of the following: |
| 453 | 100% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module |
| 454 | 100% rated Inbuilt static switch at the invertor output + No. 100% rated Inbuilt static switches at the static bypass line. |
| 455 | 100% rated Inbuilt Maintenance Bypass. |
| 456 | 100% rated battery circuit breaker |
| 457 | The UPS shall run in hot standby mode |
| 458 | Inbuilt Isolation Transformer |
| 459 | Battery bank,Sealed Maintenance Free (SMF) batteries for 20kVA UPS System to provide 30 minutes backup timeat full load with suitable no. of batteries having Total VAH required per 20kVA UPS = 38400with interconnectors, Rack and accessories and UPS to battery DC cable upto 5 meters. (Make: Exide/ Quanta ) for Battery and Pegasus,GE,APC, Schneider, Eaton for UPS |
| 460 | CABLE DISMENTLLING & HANDING OVER |
| 461 | Dismantling of under ground cables HT & LT cable system including terminations and disconnection for repair/ replacement etc. or depositing to MES store (spare/components for replacement to be provided free by department if any) |
| 462 | EXTERNAL WATER SUPPLY |
| 463 | Construction of masonry valve Chamber 90x90x100 cm inside, with common burnt clay brick in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. |
| 464 | Domestic Water Supply Pump (Hydropneumatic System With Fixed Speed System) |
| 465 | Providing, fixing and testing of packaged fixed skid mounted hydropneumatic system comprising of :- |
| 466 | Vertical, inline multistage centrifugal pumping set with stainless steel SS-304stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IECstandards and GJL250 cast iron suction& discharge casing, connected to TEFC ventilated induction motor of2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. |
| 467 | Pressure vessel of non corrosiveFRP composite construction lined with NSF and/or FDA listed material,likehigh density polyethylene with fully replaceable polyurethane. Air cell burstpressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. |
| 468 | No. and capacity of Pressure Vessel – 01 Nos. x 100 Ltrs |
| 469 | Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump workingsequence should change after every operation.Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter& voltmeter. Control panel should also consist of cooling fan. |
| 470 | Pressure switches bellowtypefittedwithmicro switch and having maximum pressure and differentialscaleshould confirming BS-6134 standards and IP55 protection class. |
| 471 | Stainless steel suction and delevery header,ball valve on each pump on section delivery side, non return valves, Y stainer complete in all respect. |
| 472 | Ball valves tobe used should be Hot Pressed brass OT-58withstainless steelballand P.T.F.Eseal and O-Ring. NRVs to be used shouldbewithSpringsandO-Ring arrangement. |
| 473 | Complete set system tobemountedona commonbase frameand shallfollow following duty. |
| 474 | For DomesticWater Supply |
| 475 | (1working + 1 stand by) |
| 476 | Capacity: 200 lpm |
| 477 | Head: 70 m |
| 478 | Drainage Sump Pumps- Submersible pumps for basement drainage & Pump Room drainage. |
| 479 | Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connectedto TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect |
| 480 | (one working + one standby/both working in high flow conditions |
| 481 | For Basement Drainage |
| 482 | (Solid handiling capacity 12mm) |
| 483 | Capacity- 250 lpm (Each) |
| 484 | Head- 15 m |
| 485 | Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system.Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables, cable trays, earthing (in accordance to specification) with earthing from panel to each motor / equipment. |
| 486 | MCC for Plumbing system |
| 487 | Incoming |
| 488 | 1 Nos. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) withwith O/L , S/C & E/F protection as per specification and with following accessories |
| 489 | 1 No. Digital MFM meter and 3 nos. CTs of ratio 100/5A , Class I accuracy and 10 VA burden. digital multifunction meter suitable to measure voltage, Ampere, Frequency, Power Factor with RS-485 Port |
| 490 | 1 Set of ON/ OFF/TRIP Indicating LED Lamps with 2 Amp MCB. |
| 491 | 1 Set of phase indicating LED lamps with 2 amp back up MCB. |
| 492 | Bus Coupler |
| 493 | 1 No. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) withwith O/L , S/C & E/F protection with1 Set of ON/ OFF Indicating LED Lamps with 2 Amp MCB. |
| 494 | Bus Bar |
| 495 | 4P copper bus bars of 125A capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec. |
| 496 | Outgoings |
| 497 | 2 No. MPCB of 32 Amp. i/c 1.1 KW DOL starter and providing outgoing feeder of 3 core, armoured coper cable of size of 6 Sq. mm to Domestic Transfer pump (including 1 No. as standby).Each compartment shall contain auto / manual selector swtich and indicating and pushbutton lamps etc. as required. |
| 498 | 40 amps 4P MCCB 2 Nos. |
| 499 | Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also be included. |
| 500 | Notes : |
| 501 | a. All MPCBs shall be of 35 KA breaking capacity and suitable for motor duty application. |
| 502 | b. Provision shall be made to ensure system protection from dry running of the pump |
| 503 | c. All incomers and Buscoupler breakers shall be electrical and mechanical interlocked with suitable accessories. |
| 504 | d. 2 Nos. Type-2 SPD 65kA 4P with1No. Red Indicator Light for SPD with 1Set. SPD Back up fuse 1P 50A 20kA including all necessary accessories. |
| 505 | For Plumbing System as described above. |
| 506 | Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system.Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables, cable trays, earthing (in accordance to specification) with earthing from panel to each motor / equipment. |
| 507 | MCC for Plumbing system |
| 508 | Incoming |
| 509 | 1 Nos. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) withwith O/L , S/C & E/F protection as per specification and with following accessories |
| 510 | 1 No. Digital MFM meter and 3 nos. CTs of ratio 100/5A , Class I accuracy and 10 VA burden. digital multifunction meter suitable to measure voltage, Ampere, Frequency, Power Factor with RS-485 Port |
| 511 | 1 Set of ON/ OFF/TRIP Indicating LED Lamps with 2 Amp MCB. |
| 512 | 1 Set of phase indicating LED lamps with 2 amp back up MCB. |
| 513 | Bus Coupler |
| 514 | 1 No. 100A, 4P MCCB, 35KA, thermal magnetic based release (Ics = Icu = 100%) withwith O/L , S/C & E/F protection with1 Set of ON/ OFF Indicating LED Lamps with 2 Amp MCB. |
| 515 | Bus Bar |
| 516 | 4P copper bus bars of 125A capacity with heat shrinkable coloured sleeves and i/c, SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec. |
| 517 | Outgoings |
| 518 | 2 No. MPCB of 32 Amp. i/c 1.1 KW DOL starter and providing outgoing feeder of 3 core, armoured coper cable of size of 6 Sq. mm to Domestic Transfer pump (including 1 No. as standby).Each compartment shall contain auto / manual selector swtich and indicating and pushbutton lamps etc. as required. |
| 519 | 40 amps 4P MCCB 2 Nos. |
| 520 | Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also be included. |
| 521 | Notes :i). All MPCBs shall be of 35 KA breaking capacity and suitable for motor duty application.ii) Provision shall be made to ensure system protection from dry running of the pumpiii) All incomers and Buscoupler breakers shall be electrical and mechanical interlocked with suitable accessories.iv) 2 Nos. Type-2 SPD 65kA 4P with1No. Red Indicator Light for SPD with 1Set. SPD Back up fuse 1P 50A 20kA including all necessary accessories.For Plumbing System as described above. |
| 522 | FIRE FIGHTING (EXTERNAL) |
| 523 | SITC Fire pump diesel engine driven horizontal end suction,entrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with \"range of operation\" 0 % to 150 % of rated capacity, 2850 LPM at outlet head of130 mts |
| 524 | SITC Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronzeimpeller and Stainless steel shaft mountedon heavy duty bearings Suitable for continuous operation with \"range of operation\" 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz.2850 LPM at outlet head of130 mts |
| 525 | SITC Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 130 m head 180 LPM discharge |
| 526 | Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope |
| 527 | Providing, laying, jointing and testing in trenches the following sizes of MS class `C\" (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring,removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. Pipes shall be embedded all around 150 mm thick compacted rilver sand and providing protection toembedded MS pipesandfittingsbyapplying pyp kote primer (@ 100 gm/sqm) thereafter wrapping 4 mm thick pyp kote (AW 4 mm) protection coating by thermo fusion process. Overlap shall be maintained at 15 mm. The application process shall be strictly according to manufacturer’s specification of following sizes:- |
| 528 | (a) 80 mm dia |
| 529 | (b) 100 mm dia |
| 530 | (c) 150 mm dia |
| 531 | Providing & fixing GM fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (2 Nos) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included). |
| 532 | Providing and fixing angle iron (40mmx40mmx5mm) door frame and S.S. sheet (2mm thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.) with 25mmx25mmx3mm angle frame all around and stiffened in between including hinges, handle, locking arrangement, painting with approved synthetic enamel paint including sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening including painting etc. as required. Glass shall be 6 mm thick.The cabinet shall be suitable to accommodate 2 nos. or 4 nos 15mtr long Hose pipe & 2 Nos branch pipe nozzle. It shall be mounted on raised Brick platform complete as required.(Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer). |
| 533 | PORTABLE CHEMICAL FIRE EXTINGUISHERS |
| 534 | Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). |
| 535 | ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 536 | ABC (Powder Type) Fire Extinguisher 6 Kg . In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and confoming to IS:1349-1993 |
| 537 | CO2 type fire extinguishers consisting of welded M.S. cylindrical body automatic modular CO2 type extinguisher actuated through a sprinkler head mounted on The extinguisher body finished externally with red enamel with trolly mounted complete with internal charge.(Capacity 22.5 Kg.) |
| 538 | Providing and fixing Clean Agent Modular (ceiling mounted) Type Capacity 5 Kg CE certified Fire Extinguisher filled with HFC 236FAClean Agent Gas. Complete in all respect. |
| 539 | SPRINKLER SYSTEM |
| 540 | Providing & fixing of 15 mm dia.sprinkler head with standard responseQuartzoid Bulb operate at 57 degree C complete with all accessories as required and as per enclosed specification (UL Listed) Upright/Pendent type in chrome finish (StandardCoverage) |
| 541 | Providing & fixing brass quartzoid sprinklers (UL, FM approved) of 15 mm dia size, suitable for sustaining the seat & water hammer effect. The type & temperature rating shall be as follows Sidewell extended coverage (57 deg.C) sprinkler quick response type as per specifications. |
| 542 | Providing and fixing reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete as perspecification of following sizes:- |
| 543 | 150mm dia. |
| 544 | 100 mm dia. |
| 545 | Providing & fixing of 25mm dia. gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specification. |
| 546 | WATER COOLER/PURIFIER |
| 547 | Supply & installation RO+UV+Uf water purifier facilitates a flow rate of up to 50 litres/hour with TDS Controller with following parameters. |
| 548 | Purification Production Rate - 50 L/hr, Maximum Duty Cycle - 250 L/Day,Filter Cartridge - Sediment,Activated Carbon,UF,Post Carbon,Body Material - ABS Food Grade Plastic,Membrane Type - Thin Film Composite RO (2),UF Membrane - 0.1 - 0.01 Micron,Auto Flushing System - Yes,Min. /Max. Operating pH - 6.5-8.0 |
| 549 | HEATING VENTILATION & AIR CONDITIONING |
| 550 | Supply, Installation, Testing and Commissioning of AHRI Certified Water Cooled Screw chiller with VFD each having a minimum Actual capacity of 220 TRat chilled water inlet/outlet temperature of 54°F/44°F with chilled water circulation rate of 528 USGPM and condenser water inlet/outlet temperature of 90°F/100°Fwith water circulation rate of 880 USGPM , suitable for operation on refrigerant R-134a for screw type machine each comprising of the following complete as per specifications and as required. Quoted price shall include price of Variable Frequency Drive starter of suitable capacity (Chiller shall have compressor of same OEM make) |
| 551 | Twin rotor based semi-hermetic type single/ multiple horizontal compressor complete with automatic capacity control from100%-20%, safety switches, forced feed lubrication system etc, as per specifications |
| 552 | Suitable capacity squirrel cage induction motor with class \"B\" insulation suitable for operation on 400+/-10% volts, 50Hz, A.C. supply. |
| 553 | Unit mounted IP 54 rated VFD Starter of suitable capacity |
| 554 | Necessary drive arrangement. |
| 555 | 1 set - Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. |
| 556 | 1 no. - matching shell and tube type even pass water cooled condenser of M.S. shell and integrally finned copper tubes and pressure drop not exceeding 10 metres. |
| 557 | 1 no. - matching shell & tube flooded/falling film type even water pass chiller for screw type units of MS shell and copper tubes and pressure drop not exceeding 10.0 metres |
| 558 | Evaporator and condenser shall be manufactured, tested and stamped with ASME(U) pressure vessel code. |
| 559 | 1 Lot - Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve. |
| 560 | 1 set - Microprocessor based control panel complete with accessories as per specifications. |
| 561 | Lot - Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc. |
| 562 | Lot - Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required. |
| 563 | Lot - Suction line and chiller insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation complete as required. |
| 564 | Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. |
| 565 | Lot- Initial/first charge of refrigerant gas & compressor oil shall be factory charged and cost for the same shall be included in the quoted rate |
| 566 | Lot- RCC / cement concrete foundation for the chilling unit. |
| 567 | Chilling machine described above, as per specifications and complete in all respects for the operating parameters as given under. |
| 568 | Refrigerant should be R-134a |
| 569 | At least one Chiller shall be tested at 4 points at 100%, 75%, 50% and 25% at AHRI conditions at manufacturer test bed before despatch. |
| 570 | Chiller |
| 571 | Chiller Water IN 54°F |
| 572 | Chilled Water OUT 44°F |
| 573 | Chilled water Flow528 USGPM |
| 574 | Fouling Factor 0.0005 FPS |
| 575 | Condenser |
| 576 | Condenser Water IN 90°F |
| 577 | Condenser Water Flow 100°F |
| 578 | Condenser water Flow 880 USGPM |
| 579 | Fouling Factor0.001 FPS |
| 580 | Minimum COP at AHRI Conditions = 6.20 min. |
| 581 | IKW/TR at Full Load = 0.66 max. |
| 582 | NPLV at design conditions not exceeding 0.37 IKW/TR |
| 583 | IPLV at AHRI conditions not exceeding 0.35 IKW/TR |
| 584 | Manufacturer’s AHRI Certified Selection Performance Sheet to be submitted to evaluate and verify the specified performance parameters |
| 585 | Thechillingmachine as describedaboveshall bein line with specifications |
| 586 | 220 TR |
| 587 | PUMPING SYSTEM |
| 588 | Chilled Water Pumps |
| 589 | Primary constant chilled water pumps |
| 590 | Supply, installation, testing and commissioning ofPN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy couplingbetween pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. |
| 591 | Casing (Volute) - Cast Iron. |
| 592 | Impeller - Gunmetal Bronze- Statically and Dynamically Balanced |
| 593 | Casing Gasket - Confined Non Asbestos Fiber |
| 594 | Pump Shaft - SS416. |
| 595 | Flush Line - Braided Stainless Steel |
| 596 | Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical sealwithout disturbing the pump shaft alignment) |
| 597 | Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz± 5%, 3Ø AC Power Supply |
| 598 | Vertical Inline Split Coupled PN16 centrifugal pump. |
| 599 | Right angle Suction guide with inbuilt guide vanes & strainer of Cast Iron body.To be supplied by pump manufacturer for unit responsibility. |
| 600 | Flow rate 528 USGPM and 15 METER head |
| 601 | Secondary Variable chilled water pumps |
| 602 | Supply, installation, testing and commissioning ofPN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy couplingbetween pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications |
| 603 | Casing (Volute) - Cast Iron. |
| 604 | Impeller - Gunmetal Bronze- Statically and Dynamically Balanced |
| 605 | Casing Gasket - Confined Non Asbestos Fiber |
| 606 | Pump Shaft - SS416. |
| 607 | Flush Line - Braided Stainless Steel |
| 608 | Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical sealwithout disturbing the pump shaft alignment) |
| 609 | Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz± 5%, 3Ø AC Power Supply |
| 610 | VFD - Integrated Mounted over Pump motor for sensorless/ wireless DPT control with IP-55 Protection,Integrated fliter to meet EN61800-3 for RFI Control, Integrated DC link Reactor equivalent in performance to a 5% AC line reactor. The VFD LCD should display the dynamic head & flow rate at any point of operation. |
| 611 | Flow rate 528 USGPM and 30 METER head |
| 612 | CONDENSOR WATER PUMPS |
| 613 | Supply, installation, testing and commissioning ofPN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy couplingbetween pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications.Casing (Volute) - Cast Iron.Impeller - Bronze- Statically and Dynamically BalancedCasing Gasket - Confined Non Asbestos FiberPump Shaft - SS416.Flush Line - Braided Stainless Steel |
| 614 | Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical sealwithout disturbing the pump shaft alignment) |
| 615 | Motor Type - TEFC Squirrel Cage, Efficiency Class - IE3, Insulation - Class F, 415V ± 10% , 50Hz± 5%, 3Ø AC Power Supply |
| 616 | Capacity of each pump (LPM) 2495 |
| 617 | Pump Head (Mt)25 |
| 618 | Pump Efficiency Not less than 75% |
| 619 | Maximum Permissible Speed 1450 RPM |
| 620 | HP of Motor30 |
| 621 | COOLING TOWERS |
| 622 | Supply,installation, testing &commissioning of FRP induced draft cooling tower of capacity 275 TR (831600 Kcal/Hr) complete with sump & steel ladder, EFF 2 type fan motors suitable for 415 V, 3 phase, 50 Hz. MS Structure for mounting Cooling Tower, access arrangement for cooling tower interior, cement concrete foundation, stel / masonry support structure, anti vibration mountings etc all as specified and as directed by Engineer-In-Charge.(2Working +1 Stand By) |
| 623 | Sound Level75dB at 1Mt |
| 624 | Inlet Water Temperature 36.39 °C |
| 625 | Outlet Water Temperature32.22 °C |
| 626 | HP of C/T Fan Motor 2 x 7.5HP |
| 627 | HOT WATER BOILER SUITABLE FOR OUTSIDE CONDITION |
| 628 | Supply, installation, testing and commissioning of Electric Hot Water Generator of vertical construction equipped with sufficient number of flanges and electric immersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.60mm Aluminum cladding as per specifications. The hot water generator shall be equipped with all automatic and safety controls such as high temperature water thermal cutout, Low water level cut-off, PLC, HMI other controls . The hot water generator shall be control by PLC based Step controller and HMI screen and BMS compatible having Ethernet/RS485 Port. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts,50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested.Note:11. Water ‘IN’ temperature : 45 deg C.2. Water ‘OUT’ temperature: 50 deg C Nos 65 Kw(1w+1s) |
| 629 | Hot Water Pumps |
| 630 | Supply, installation, testing and commissioning ofPN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy couplingbetween pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. |
| 631 | Casing (Volute) - Cast Iron. |
| 632 | Impeller - Gunmetal Bronze- Statically and Dynamically Balanced |
| 633 | Casing Gasket - Confined Non Asbestos Fiber |
| 634 | Pump Shaft - SS416. |
| 635 | Flush Line - Braided Stainless Steel |
| 636 | Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical sealwithout disturbing the pump shaft alignment) |
| 637 | Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz± 5%, 3Ø AC Power Supply |
| 638 | 2 Nos. (1W+1S) Vertical Inline Split Coupled PN16 centrifugal pump |
| 639 | Right angle Suction guide with inbuilt guide vanes & strainer of Cast Iron body.To be supplied by pump manufacturer for unit responsibility. |
| 640 | Flow rate 80 USGPM and 15 METER head (1W+1S) |
| 641 | MICROBUBBLE AIR & DIRT SEPRATOR |
| 642 | Supply, installation,testing & commissioning of Micro bubble Air & Dirt Separator capability,automatic air purging arrangement etc.The shell shall be constructed of mild steel with coalescence. It shall work on the principle of coalescence.The water velocity the shall not Exceed 1.5m/sec.The M.S shall to be fabricated or other similar standard.The inlet and outlet connections shall be flanged. It shall be provided with a high capacity auto air vent at the to and a drain valve at the bottom.Matching flanges, high tensile bolts & nuts and gasket shall be also provided By the manufacturer.it shall be duly insulated 32mm thick class O Nitrile rubber insulation as per specifications complete as per specifications.The design parameters for the air separator of efficiency 96-98 % should be as follows with Safety working pressure:3.5 bar (32mm thick insulation) Line Size:250 mm diameter |
| 643 | Supply, installation,testing & commissioning of Micro bubble Air & Dirt Separator capability,automatic air purging arrangement etc.The shell shall be constructed of mild steel with coalescence. It shall work on the principle of coalescence.The water velocity the shall not Exceed 1.5m/sec.The inlet and outlet connections shall be flanged. It shall be provided with a high capacity auto air vent at the to and a drain valve at the bottom.Matching flanges, high tensile bolts & nuts and gasket shall be also provided By the manufacturer.it shall be duly insulated 32mm thick class O Nitrile rubber insulation as per specifications complete as per specifications.The design parameters for the air separator of efficiency 96-98 % should be as follows with Safety working pressure:3.5 bar (32mm thick insulation) Line Size:100 mm diameter |
| 644 | Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of Totally Type Tested Panels (Form-4B construction) complying to IEC:61439 -1/2 cubical with Internal arc withstand of 50kA for 0.3 second and minimum impact resistance IK10 as per IEC:62262 with each compartment front unbreakable glazed door cover and back solid door. The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use. Panels shall be tested for an Impulse Withstand Voltage of 12kV. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system bolted fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thickplates for MDB/MCC and SDBs etc.incl. cleaning & finishing complete, SMC bus bar supports, with short circuit withstand capacity of minimum 50kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common copper contineous earth bar of size 40mm x 6mm or as specified below at the rear with 2 Nos. earth stud each side, solid inter connections from main bus bar to switch gears upto cable alley with required size. bus bars and insulated control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, incl. providing following switch gears :- |
| 645 | Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provided withfully automtic control thermostate with strip heater. |
| 646 | INCOMER |
| 647 | Incomers –2 Nos x 1500 Amps 4P ACB(1w+1s) 50 kA for O/C , S/C& E/Fproctection ,reverse power relay- trip & RS485 Port,cable connection on one side and Busbar connection on the other side. |
| 648 | INDICATING PANEL |
| 649 | Provide 1nos phase indicating lamps LED each backed up with fuse and switch. |
| 650 | Provide 2600/5a CT CI-1,15VA operatedDigital Ammeter for all in-comers and outgoings including C/T\"s. |
| 651 | Provide 0-500 Volts range Digital Volt Meter with selector switch for all incomers |
| 652 | Two numbers indicating lamps LED on each incoming and outgoing feeder for indicating the status of feeder. |
| 653 | One number indicating lamp LED on each incoming and outgoing feeder for indicating that the feeder has tripped due to fault condition. |
| 654 | 1 No. Power factor meter |
| 655 | 1 No. Digital type energy meter. |
| 656 | Break Control Switch (T-N-C) |
| 657 | Control Fuse+Base |
| 658 | BUSBARS |
| 659 | Sections of 1Nos x 2000 Amps 4P bus bar chamber of suitable lengths with Aluminium bus bars. All bus bars and interconnections shall be of suitable size Al strips. Current density of Al shall not be more than 1.0 Amps/ sq.mm cross sectional area of Bus Bar |
| 660 | Incomer and 1Nos x2000 A EDO 4P ACBbus coupler shall be mechanically & electrically interlocked to avoid paralleling of the two supplies. |
| 661 | OUTGOING |
| 662 | 3#220 TR Water Cooled Screw Chiller(2 #Working+1no of stand by) |
| 663 | 450A4P ACB of suitable rating with overload, short circuit protection, on /off /trip indicationlightwith control MCB. MCCB Shall be 35 KA (ICU=ICS) SET - 04 ( Extra 1 Nos Spare) |
| 664 | 3#Primary Pumps ( 2W+1S) @ 15 HP |
| 665 | 63A TPN MCCB of suitable rating with15 HP Star delta stater, overload relay inbuilt single phase prevention, start/stop push buttons, MFM, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 35 KA (ICU=ICS) SET - 04 ( Extra 1 Nos Spare) |
| 666 | 3# secondary pumps ( 2W+1S) |
| 667 | 100 A TPN MCCB of suitable rating with Space of 30 HP VFD, overload relay inbuilt single phase prevention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 35 KA (ICU=ICS) SET - 04 ( Extra 1 Nos Spare) |
| 668 | 3#CDW Pumps ( 2W+1S) @ 40 HP |
| 669 | 100 A TPN MCCB of suitable rating with Space of 50 HP VFD, overload relay inbuilt single phase prevention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 35 KA (ICU=ICS) SET - 04 ( Extra 1 Nos Spare) |
| 670 | 3# 275TR C/T ( 2W+1S) (2x7.5 HP) |
| 671 | 2 nos 63A4P MCB of suitable rating with overload, short circuit protection, on /off /trip indicationlightwith control MCB. MCCB Shall be 35 KA (ICU=ICS) SET - 04 ( Extra 1 Nos Spare) |
| 672 | 2#Hot Water Pumps (15 HP) |
| 673 | 63 A TPN MCCB of suitable rating with Space of 15 HP VFD, overload relay inbuilt single phase prevention, start/stop push buttons, on / off / trip indication lights with control MCB, Auto Manual Selector switch. MCCB Shall be 35 KA (ICU=ICS) SET - 03 ( Extra 1 Nos Spare) |
| 674 | 2#65 KW Hot Water Generator(1 #Working+1no of stand by) |
| 675 | 185 Amp4P MCB of suitable rating with overload, short circuit protection, on /off /trip indicationlightwith control MCB. MCCB Shall be 35 KA (ICU=ICS) SET - 03 ( Extra 1 Nos Spare ) |
| 676 | FLOOR MOUNTED CHILLED WATER AIR HANDLING UNITS FORWARD CURVED |
| 677 | Supply, installation, testing and commissioning of factory fabricatedDouble Skinned Chilled Water Air- handling unit Floor Mounted type fabricated with forward curve fan of static 50 mm out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with blower, Plug fan /blower section anddirectdriven / blower motor TEFCtype suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row coolingcoil made of Aluminium finned Copper tube with coil section,with following filtration level, polished stainless steel drain pan madeoutof 22 G sheet duly insulated complete with motor and belt drivepackage etc. without face and bypass dampers. The AHU panels shall be insulated with 23 mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only |
| 678 | (a)Theface velocity across cooling coil shall be limited to 152 MPM maxm. |
| 679 | (b)Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUS |
| 680 | (c)Fan Oulet Velocity Not to Exceed 10 m/s |
| 681 | (d)6 RD Cooling Coil(CC) |
| 682 | (e)2 RD Heating Coil(HC) |
| 683 | The complete AHU shall confirm to above & standard specification. |
| 684 | The capacity of Air-handlers shall be as follows: |
| 685 | FM AHU 1x18000 CFM AHU/50 MM Static |
| 686 | HYDRONIC UNITS (HI WALL TYPE) |
| 687 | Supply, Installation, Testing and Commissioning of the following equipment as per tender drawings, and specifications. |
| 688 | Wall Mounted Hydronic units complete , fresh air port , filter box complete with synthetic fiber filters, cooling coil, fans, 3-speed motors,drain pipe connection with drain pump complete. |
| 689 | Valves Set :- Copper flexible connection complete with set of ball valves withstrainer & ball valves without strainer,thermostat, Two way motorised control cum balancing valve(Pressure independent valve ), control wiring. |
| 690 | Electrical and control cabling for proper connection from the 15 amps outlet to connector box, valve etc. as well as connection of thermostat. |
| 691 | Hydronic units of minimum capacity in BTU/HR & CFM as follows : |
| 692 | 12000Btu/Hr /2RD /400CFM ( 1.0 TR) |
| 693 | 18000Btu/Hr /2RD /600CFM( 1.5 TR) |
| 694 | DX TYPE HI WALL UNIT (GREEN GAS) |
| 695 | Supply , installation, testing & Commissioning of DX type split AC 2.0. TR Dx type Hi wall Unit with air cooled condenser mounted in outdoor unit complete with scroll/rotary compressor ,condeNSOR ,wiring & accessories . Indoor units shall be wall mounted type complete with evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , cordless remote controls. The unit shall be suitable for working,50 cycle /second ,1 phase AC supply .The unit shall be designed to take care of veritcal head 4mt & horizontal length of 30 mt & necessary oil seprator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy paintedMS stand for ODU units as per approved make shade by Engr in Charge) with necessary vibration isolation arrangement as per site condition etc.( with condensate drain pipe ,electrical pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid seprately ). The Color of the outdoor units to be finalized by theEngr InCharge as per building Architectural elevation. |
| 696 | Supply, installation, testing and commissioning of copper refrigerant piping -Copper Pipe(Two Length) suitable for 2.0. TR Dx type Hi wall Unit duly insulated with 9mm thick nitrile rubber of Class \"O\" between the above indoor & outdoor units as shown on OEM drawing enclosedwith necessary supports etc |
| 697 | Supply, installation, testing and commissioning of ultrasonic type Humidification package with Humidistat with all necessary control cabling as required as per standard specification & of following capacities: |
| 698 | 3LPH |
| 699 | 5LPH |
| 700 | Supply, Installation , testing , commissioningand handing over of the coil mounted HYBRID Ultra Violet Germicidal Irradiations ( UVGI) System for maintainingindoor Air Quality in indoor units. The system should be capable of reducing the airborne as well as surface bacteria, virus, mold, etc. The system should bedesigned to achive kill rate of not less than 90% per pass. The HYBRID UV system shall be designed to provide UV dosage of 2000 micro W/cm2 and should produce equal amount of positive & negative reactive oxygen species based on bi-polar plasma ionization to actively reduce the airborne & surface borne pathogens and other chemical gasses such as VOCs. The lamp shall have minimum 9000 working hrs life, ballasts shall be electronic type, life rated grater than 15000 starts. The lamp used should be T5 type, quartz glass, bi-pin type with ceramic ends. High quality aluminium reflector should be the part of the system. An run hour meter shall be provided to indicate remaining life of the Lamp in the form timer of digital display. Minimum UV intensity should be 500 microwatts at all the corners of the cooling coil. Minimum 4ft length of the duct should be covered with UV lights.Should follow IEC 61347-2-3, IEC 61000-3-2, IEC 61547, safety standards.Should follow IEC 60929, IEC68-2-6 Fc, IEC 68-2-29 Eb The lamps should be ISO Certified and plasma ionizers should be UL listed.The vendor should conduct bacteria test or bio test in any 2 locations to be done before and after installation.Note : All AHU,fcu and duct type unit shall be with UVGI |
| 701 | UPTO 5000 CFMDIDW FAN FOR EXHUAST/FRESH AIR IN NORMAL MODE VENTILATION |
| 702 | Supply,installation,testing and commissioning of ceiling mounted DIDW fans (AMCA Certified) with adjustable pitch blade & angle ,MS/GI casing, cast aluminium alloy impeller completewithTEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4 pole,three Phase, A.C supply class\"F\" insulation with support & Motor rated Value IP55, mountings and flexible connection etc. & offollowing capacity.Note : - Outlet Velocity not to exced 10.0 MPS |
| 703 | Exhaust air in case of normal mode ventilation system Air Qty.= 4500CFM Static Pressure =30 mm WgMotor Pole= 4 PoleMotor = Not exceeding 3.7 Kw. |
| 704 | Exhaust air in case of normal mode ventilation system Air Qty.= 28000 CFM Static Pressure =30 mm WgMotor Pole= 4 PoleMotor = Not exceeding 15 Kw. |
| 705 | Exhaust air in case of normal mode ventilation system Air Qty.= 40000 CFM Static Pressure =30 mm WgMotor Pole= 4 PoleMotor = Not exceeding 15 Kw. |
| 706 | Fresh air in case of normal mode ventilation system Air Qty.= 4500CFM Static Pressure =30 mm WgMotor Pole= 4 PoleMotor = Not exceeding 3.7 Kw. |
| 707 | DOUBLE SKINNED AIR WASHER UNITS |
| 708 | Supply, installation, testing & commissioning of factory fabricateddouble skin Air-Washer comprising of 1No.DIDW GIfan, forward curved, complete with base frame,casing made out of 0.63mm galvanised sheet having flanged & boltedpanels insulated with PUF injectedbetween outer skin and inner skin.(The inner skin shall be PVC / Fibreglass lined also), wet section & tank shallbe made of stainless steel.The Air-washer shall be complete with fill of depth 200mm & face velocity across the fill shall be limited to152 MPM..The Air -washer shallhave an efficiency of 90% & shall be complete with motor, belt drive package, GI B Class interconnecting piping,valves, strainer NRV, aluminum viscous filters ,water pumps(1working +1stand by) for each air washeretc. & of the following capacities.Note : - Outlet Velocity not to exced 10.0 MPS |
| 709 | Air Quanitty :- 56000 CFM Motor : 1440 RPMStatic Pressure: 50 mm of WGMotor Kw : Not Exceed 1x15 Kw |
| 710 | Air Quanitty :- 75000 CFMMotor : 1440 RPMStatic Pressure: 50 mm of WGMotor Kw : Not Exceed 2x11 Kw |
| 711 | PROPELLER FANS |
| 712 | Supply, installation, testing & commissioning of wall mounted Propellar fans AMCA certified suitable for single phase, 230 volts, 50HzAC. supply of following capacities: completerequired offollowing capacities & as pershop drawing mentioned. |
| 713 | 300mm dia |
| 714 | 225 mm dia |
| 715 | INLINE FAN WITH SPEED REGULATOR |
| 716 | Supply,installation,testing and commissioning of ceiling suspendedInline fansAMCA certified (Rectangular/Round casing) complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required offollowing capacities as per specification and shop drawing mentioned. |
| 717 | Capacity: 800CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 718 | Capacity: 1100 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 719 | Capacity: 1400 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 720 | Capacity: 1500 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 721 | Capacity: 1700 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 722 | Capacity: 2000 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 723 | Capacity: 2100 CFM Static Presure : 20 mm Of wg Kw :0.7 KW |
| 724 | TUBE/VANE AXIAL FLOW FANS WITH SOUND ATTENUATOR FOR NORMAL MODE AS WELL AS FIRE MODE VENTILATION (FRESH AIR FAN ) |
| 725 | Supply, installation, testing & commissioning of floor mounted double flanged, casing (motor should completly accomodated in Fan casing) axial flow fans AMCA Certified, with adjustable pitch blade & angle ,bird screen at fan inlet, MS/GI casing, cast aluminium alloy impellercomplete with TEFC Sq. Cage Inductionmotor suitable for 415 volts ± 10%,50Hz ± 3 %, 4/6/8pole, three Phase, A.C supply class \"F\" insulation with support, Phase&Motor rated Value IP55with following parameters & capacity:-Note: The rate deemed to includesupply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connectionpainting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc |
| 726 | 1.Outlet Velocity for normal mode fans not to exceed 14.0 MPS |
| 727 | 2. Outlet Velocity for Fire mode fans not to exceed 18.0 MPS |
| 728 | 3. Total efficiency of normal fans shall not less than 60% |
| 729 | 4. Fan motor shall meet IE3standard as per IS-12615 |
| 730 | 5.Static pressure and Motor Rating : TheIndicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Engr in charge. Sound attenuator shall be as specified with following characteristics: |
| 731 | 5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. |
| 732 | 6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted. |
| 733 | 7.Vane Axial fan would use for Normal mode ventilation & Tube axial would use for Fire mode |
| 734 | Fan Capacity = 5000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 735 | Fan Capacity = 12000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 736 | Fan Capacity = 14000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 737 | Fan Capacity = 19000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 738 | Fan Capacity = 22000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 739 | Fan Capacity = 25000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 11 KWNoise level = not exceed 85 db at 3 meter distance |
| 740 | Fan Capacity = 28000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 11 KWNoise level = not exceed 85 db at 3 meter distance |
| 741 | Fan Capacity = 30000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 742 | VANE/TUBE AXIAL FLOW FANS WITH SOUND ATTENUATOR FOR NORMAL AS WELL AS FIRE MODE FAN (EXHAUST AIR ) |
| 743 | Supply, installation, shifting, loading, unloading, testing & commissioning of Floor mounted, double flanged, long casing (motor should completly accomodated in Fan casing) Vane/tube axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle, bird screen at fan outlet , MS/GI casing, cast aluminium alloy impellercomplete with TEFC Sq. Cage Inductionmotor suitable for 415 volts ± 10%,50Hz ± 3 %, 4/6/8 pole, three Phase, A.C supply class \"H\" /S insulation with support, Phase&Motor rated Value IP55 . Motor shall be Thermally Rated for 250 deg C for 2 Hours should be certified as per BSEN12101-3:2002 standard & direct driven for smoke extraction fans with following parameters & capacity:- Note:-The rate deemed to includesupply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc |
| 744 | Sound attenuator shall be as specified with following characteristics: |
| 745 | 1. Length not exceeding 1D (Fan Dia.) |
| 746 | 2. Pressure drop through through sound attenuator shall not exceed 8mm WC |
| 747 | 3. Outlet Velocity for normal mode fans not to exceed 14.0 MPS |
| 748 | 4. Outlet Velocity for Fire mode fans not to exceed 18.0 MPS |
| 749 | 5. Total efficiency of normal fans shall not less than 60% |
| 750 | 6. Fan motor shall meet IE3standard as per IS-12615 |
| 751 | 7.Static pressure and Motor Rating : TheIndicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Engr in charge. Sound attenuator shall be as specified with following characteristics: |
| 752 | 8. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. |
| 753 | 9. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted. |
| 754 | 10.Vane Axial fan would use for Normal mode ventilation & Tube axial would use for Fire mode |
| 755 | Fan Capacity = 5500 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 756 | Fan Capacity = 6500 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 757 | Fan Capacity = 14000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 758 | Fan Capacity = 22000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 759 | Fan Capacity = 23000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 7.5 KWNoise level = not exceed 85 db at 3 meter distance |
| 760 | Fan Capacity = 28000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 11 KWNoise level = not exceed 85 db at 3 meter distance |
| 761 | Fan Capacity = 40000 CFMStatic Pressure = 20 mm WgMotor Rating = Not Exceed 3.7 KWNoise level = not exceed 85 db at 3 meter distance |
| 762 | JET FANS WITH CFD ANALYSIS |
| 763 | Supply ,installation ,testing & commissioningof Ductless Ventilation / Jet fans AMCA certified(2D silencer both side) as per specifications for normal ventilation suitable for Normal ventilation and Smoke Extraction application in case of emergency i.e. 300 Deg C / 2 Hrs operation.Each fan shall be complete with motor and impeller. The Casing of fans shall be made of hot dipped Galvanized steel. The complete fan assembly with its Casing, impeller & motor (not only the motor or one of the item) shall be certified as tested for 300 Deg C for 2 hours operation The Motor shall be suitable to run on 3 phase/50 hz/ 415 v electrical power, of following size.The CFD Analysis shall also be submitted by the Vendor at the time of installation to varify the qty and location of jet fans. |
| 764 | 400 mm Dia. Jet fan Motor: as per dataMounting :Ceiling SuspendedInstallation along with Anchor Fastners (Hilti) |
| 765 | Supply ,installation ,testing & commissioningCO-SeNSOR confirming to UL & NFPA standard |
| 766 | Electrical Panel for jet fans PLC cum control panel |
| 767 | Supply ,installation ,testing & commissioningof BMS compatible power and control panel with allnecessary control logics and software feeding the exhuast and the jet fans Shall give power and control the Jet Vent fans, main exhaustand fresh air fans, CO SENSORS suitable for 30-90 ppm atpollution mode low speed.At 100 ppm and above and smoke mode during emergency system should run at high speed.Otherwise full system will run at the cycles mode Shall have the provision for hooking up the panel with fire fighting panel in case of emergecny shall have the provision for monitoring the whole system through BMS |
| 768 | PIPING WORK -CONDENSOR WATER PIPING/COOLING TOWER PIPING WITH INSULATION |
| 769 | Supply, laying /fixing, testing and commissioning of following nominal sizes of piping withinsulation (with necessary clamps, vibration isolators & fittings but excluding valves,strainers,Guages etc.) with fire retardant quality expanded polystyrene moulded pipe section of 20kg/m3 after a thick coat of cold adhesive (CRPX Compound )wrapping with 500G polythene faced hessian & finally applying o.63mm aluminum sheet cladding complete with type 3 grade 1 roofing felt strip (as per IS : 1322 as amended up to date ) at joints repairing of damage to building etc. as per specification & as required complete in all respect .Note : The pipe of Size 150mm & Below shall be MS C class as per IS :1239 & pipe size above 150mm dia shall be welded black steel pipe heavy class as per IS :3589, from minimum 6.35 thick MS sheet for the pipes upto 350 mm & from minimum 7mm thick MS sheet for the pipes of 400mm Dia & Above |
| 770 | 350 mm dia (75mm thick Insulation) |
| 771 | 300mm dia (75mm thick Insulation) |
| 772 | 150mm dia (75mm thick Insulation) |
| 773 | 125mm dia (75mm thick Insulation) |
| 774 | 100 mm dia (50mm thick Insulation) |
| 775 | CONDENSOR WATER PIPING / COOLING TOWER PIPING WITHOUT INSULATION |
| 776 | Supplying, fixing, testing & commissioning of condenser water pipes of following sizes of MS \"C\" class along with necessary clamps, vibration isolators & fittings such as bends, tess etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted / buried in ground excavation and refilling etc. as per specification and as required complete in all respect.Note : The pipe of Size 150mm & Below shall be MS C class as per IS :1239 & pipe size above 150mm dia shall be welded black steel pipe heavy class as per IS :3589, from minimum 6.35 thick MS sheet for the pipes upto 350mm & from minimum 7mm thick MS sheet for the pipes of 400mm Dia & Above. |
| 777 | 350 mm dia |
| 778 | 300mm dia |
| 779 | CHILLER & CONDENSER SIDE |
| 780 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/ cumdensityresinbondedfiberglassor144Kg/cumdensitymineralwool insulation (non combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying star bond coating and repairingofdamagetobuilding etc.asper specifications and as required.Note:The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. |
| 781 | 300 mm dia (75mm thick Insulation) MS PIPE |
| 782 | 250 mm dia (75mm thick Insulation) MS PIPE |
| 783 | 200 mm dia (75mm thick Insulation) MS PIPE |
| 784 | 150 mm dia (50mm thick Insulation) MS PIPE |
| 785 | 125 mm dia (50mm thick Insulation) MS PIPE |
| 786 | 100 mm dia (50mm thick Insulation) MS PIPE |
| 787 | 80 mm dia (50mm thick Insulation) MS PIPE |
| 788 | 65 mm dia (50mm thick Insulation) MS PIPE |
| 789 | 50 mm dia (50mm thick Insulation) MS PIPE |
| 790 | 40 mm dia (50mm thick Insulation) MS PIPE |
| 791 | 32 mm dia (50mm thick Insulation) MS PIPE |
| 792 | 25 mm dia (50mm thick Insulation) MS PIPE |
| 793 | HIGH SIDE VALVES INSULATED VALVES |
| 794 | Supplying, fixing, testing & commissioning of following valves, strainers, gauges in the chilled/Hot water plumbing duly insulated to the same specifications as the onnected piping and adequately supported as per specifications. |
| 795 | Butterfly Valve Wafer Type Butterfly Valves, Ductile (SG) Iron Body & Disc SS-431 Shaft EPDM Integrally Mouded Liner with Hand Lever Operated upto size 150mm, 200mm & ab0ve Gear OperatedPressure Rating PN16 |
| 796 | 300 mm Dia (75 MM Thick Insulation ) |
| 797 | 250 mm Dia(75 MM Thick Insulation ) |
| 798 | 200 mm Dia(75 MM Thick Insulation ) |
| 799 | 150 mm Dia (50 MM Thick Insulation ) |
| 800 | 125 mm Dia (50 MM Thick Insulation ) |
| 801 | 100 mm Dia (50 MM Thick Insulation ) |
| 802 | 65 mm Dia (50 MM Thick Insulation ) |
| 803 | 50 mm Dia (50 MM Thick Insulation ) |
| 804 | 40 mm Dia (50 MM Thick Insulation ) |
| 805 | 32 mm Dia (50 MM Thick Insulation ) |
| 806 | Balancing Valve with built in measuring facility with CI Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled/Hot water circulation as specified. |
| 807 | 200 mm Dia (75 MM Thick Insulation ) |
| 808 | 150 mm Dia (50 MM Thick Insulation ) |
| 809 | \"Y\"strainer of ductile CI Body flanged ends with stainless steel strainer for chilled/hot water water circulation including insulation as specified. |
| 810 | 200 mm Dia(75 MM Thick Insulation ) |
| 811 | 65 mm Dia (50 MM Thick Insulation ) |
| 812 | Non- return Valve with dual plate of CI Body SS Plates vulcanised NBR seal flanged end & PN16 pressure rating for chilled/Hot water circulation including insulation as specified. |
| 813 | 200 mm Dia(75 MM Thick Insulation ) |
| 814 | 65 mm Dia (50 MM Thick Insulation ) |
| 815 | Pot Strainer 300 mm dia |
| 816 | Supply, Installation, Testing & Commissioning of Equalizer Valvein dirt legs complete with nipples as per specifications, 150mm dia. |
| 817 | Supplying, fixing, testing and commissioning of SG Iron Body flow switch with necessary control wiring and interlocking atCondenser Water Pump |
| 818 | Supplying, installation, testing and commissioning of on line scale preventer suitable 300 Dia and flow rate with necessary fittings and accessories. |
| 819 | Supply, installation, testing and commissioning of test points in brass / bronze construction with non return ring complete with suitable size socket on insulated lines complete nipples etc. as required for measurement of pressure and temperature. |
| 820 | Supply, installation, testing and commissioning of digital thermometer with adopter for above test point. |
| 821 | Supply, installation, testing and commissioningof digital Pressure gauge with adopter for above test point. |
| 822 | Supply, Installation, Testing & Commissioning of Drain Valves in dirt legs complete with nipples as per specifications of following sizes:- |
| 823 | 50 mm Dia |
| 824 | 40 mm Dia |
| 825 | 25 mm Dia |
| 826 | Supply, installation, testing and commissioning of duly insulated with 80mm thick(40mm in two layers ) expanded polystrene P quality with aluminium cladded open type expansion tank made out of 5 mm thick MS sheet of size 1.0mt x1.0mt x 1.0mt inner surface area epoxy paint two coats to avoid rust complete withallaccessories valves &fittings forchilled water as per specs . |
| 827 | LOW SIDE VALVES |
| 828 | Supply, installation, testing and commissioning of following Ball Valve PN 16 rating duly insulated with Al Cladded valves as per pipe dia as detailed above , complete with companion flanges, nuts ,bolts , gaskets etc.as specified.confirming to specification |
| 829 | 40 mm Dia |
| 830 | 32 mm Dia |
| 831 | 25 mm Dia |
| 832 | Supply, installation, testing and commissioning of following Butterfly Valve PN 16 rating duly insulated with Al Cladded valves etc of same rating as per pipe dia as detailed above , complete with companion flanges, nuts ,bolts , gaskets etc.as specified.confirming to specification |
| 833 | 80mm Dia |
| 834 | 65mm Dia |
| 835 | 50mm Dia |
| 836 | Supply, installation, testing and commissioning of Balancing ValvePN 16 rating duly insulated with Al Cladded valves etc of same rating as per pipe dia as detailed above , complete with companion flanges, nuts ,bolts , gaskets etc.as specified.confirming to specification of following sizes:- |
| 837 | 80mm Dia |
| 838 | 65 mm Dia |
| 839 | 50 mm Dia |
| 840 | 40 mm Dia |
| 841 | 32 mm Dia |
| 842 | 25 mm Dia |
| 843 | Supply, installation, testing and commissioning of\"Y\" type strainer PN 16 rating duly insulated with Al Cladded valvesetc of same rating as per pipe dia as detailed above , complete with companion flanges, nuts ,bolts , gaskets etc.as specified.confirming to specification of following sizes:- |
| 844 | 80 mm Dia |
| 845 | 65 mm Dia |
| 846 | 50 mm Dia |
| 847 | 40 mm Dia |
| 848 | 32 mm Dia |
| 849 | 25 mm Dia |
| 850 | Supply, installation, testing & commissioning of motorised 2 way Modulating Valve complete with electrical actuator,heavy duty PN10 cast iron body with nylon coated S.G. iron disk,water sealant lining, stainless steel shaft, control lever with thermostat control wiring,accessories if any like transformer etc.position confirming to standard specification for the following sizes |
| 851 | 80 mm Dia |
| 852 | 65 mm Dia |
| 853 | 50 mm Dia |
| 854 | 40 mm Dia |
| 855 | 32 mm Dia |
| 856 | 25 mm Dia |
| 857 | 20 mm Dia |
| 858 | Supply, Installation, Testing, & Commissioning of Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent of size 15 mm dia auto air vent valve |
| 859 | Supply, Installation, Testing & Commissioning of 25mm diameter Drain Valves in dirt legs complete with nipples as per specifications. |
| 860 | Supply, installation , testing &commissioningof 13mm nitrile rubber Class O insulated condensatedrain water piping of GI \"Medium\" class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting etc. as required conforming |
| 861 | 50 mm dia pipe |
| 862 | 40 mm dia pipe |
| 863 | 32 mm dia pipe |
| 864 | 25 mm dia pipe |
| 865 | AIR DISTRIBUTION-GSS RECTANGULAR DUCTING |
| 866 | Supply, Installation, Balancing & Commissioning of factory fabricated GSS sheet metalducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc finally applying fire rated paint as per BS 476 Part 24 . as per approved drawings and specifications of following sheet thickness complete as required.Note:-splitter & vanes etc. shall be a part of ducting no extra cost shall be paid for the same .All support selection shall be based on gripple wire .No other support shall be acceptable. |
| 867 | 0.63 mm sheet duct |
| 868 | 0.80 mm sheet duct |
| 869 | 1.0 mm sheet duct |
| 870 | 1.25 mm sheet duct |
| 871 | Supply, Fabrication, installation and testing of GSS sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24(SiteFABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications. |
| 872 | 0.63 mm sheet duct |
| 873 | 0.80 mm sheet duct |
| 874 | 1.0 mm sheet duct |
| 875 | 1.25 mm sheet duct |
| 876 | Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded linear fixed horizintal bar/grill/Diffuserswith all side flangesas per approved shop drawings. |
| 877 | SSupply, installation, testing and commissioning of GI volume control duct dampercomplete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc. as per specifications.(18G) |
| 878 | Supply,Installation and Testing of 50 micron powder coated, aluminum extruded volume control damper for collor to be provided with suitable links and quadrants for control of volume of air. |
| 879 | Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded fresh air louvers with bird screen & aluminum volumne control damper with all side flanges as per approved shop drawings. |
| 880 | Supply, Installing, testing of fire retardant flexible canvass connector 200 mm deep made of imported FIBER GLASS WEAVE fabric with Silicon Rubber Coating & 30 mm Extruded Aluminum Frame. |
| 881 | Fire Dampers |
| 882 | Supply, installation, testing & commissioning of Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of atleast 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor. |
| 883 | Damper Actuator |
| 884 | Supply, installation, testing and commissioning ofMotorised Spring ReturnActuator fordevices upto0.8 sq. metrewithwith control panel & temperature sensor. |
| 885 | INSULATION WORK. |
| 886 | Insulation material 13mm thick shall be closed cell flexible elastomeric foam based on synthetic rubber composition with fire retardant properties.The insulation material shall have Microban®* an anti-microbial product, which is EPA (Environmental Protection Agency), USA Approved, as an integral part of insulation that cannot be washed off or worn off. The insulation material shall give enhanced level of protection against harmful Microbes such as fungi, bacteria & mold and should confirm to UL 181, ASTM G 21/C 1338. Thermal conductivity of insulation material shall not exceed 0.036 W/(m.K) atmean temperature of 24C as per ASTM C 177 / ASTM C 518. Water Vapor Permeability of insulation material shall be minimum 0.05 Perm-in. /0.725 x 10-13 Kg/[s.m.Pa] without any external barrier as per ASTM E 96. Procedure A. The insulation material shall have water absorption of 0.2% by volume as per ASTM C 209 / ASTM C 1763.The insulation material shall have fire performance rating of 25/50 as per ASTM E 84. The insulation material shall have fire performance rating of UL 94. The insulation material shall be self-extinguishing, does not drip, and does not spread flames. . The insulation material shall be dust and fibre free. The insulation material shall be formaldehyde free. The insulation material shall be CFC & HCFC free. The insulation material shall meet ASHRAE 90.1-2010, ASHRAE Standard 189.1, NFPA 90A & NFPA 90B Standards. The insulation material shall withstand maximum surface temperature of +105 Deg.C and minimum surface temperature of -50 Deg.C as per ASTM C 534. The insulation material shall have ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) of Zero. The insulation material shall be applied indoors. Coverings shall be used for exposed areas.Thickness of the insulation shall be as specified for the individual application. The insulation material shall be installed as per manufacturer’s recommendation. |
| 887 | ACOUSTIC INSULATION - FOR DUCT |
| 888 | Supply and Application of Acoustic Insulation Inside the Duct of following thickness with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection; to be applied using manufacturer\"s recommended Rubber based Adhesive in a blend of solvents. , Metal Strips and Anchor Fasteners as per design. |
| 889 | 15 mm thickness (Internal Lining of Ducts) |
| 890 | 25 mm thickness (Internal Lining of Ducts) |
| 891 | Supplying, fixing acoustic lining on wall and ceiling of AHU rooms & plant room with Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection; to be applied using manufacturer\"s recommended Rubber based Adhesive in a blend of solvents. , Metal Strips and Anchor Fasteners as per design. |
| 892 | ROOF INSULATION |
| 893 | Supply & Installationof Thermal Insulation 25 mm thick Class O Nitrile Rubber Insulation with GC cloth on Duct exposed to sunlight using Closed CellAnti Microbial and Anti Fungal Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.035 W/mk at 200 Celcius Mean Temp. and Mu≥10000 and with Chemically treated Factory Laminated Woven Fibre Glass Cloth with200+/-20 gsm using manufacturer\"s recommended Rubber based Adhesive in a blend of solvents complete as per Specifications |
| 894 | CUBICAL PANEL BOARD |
| 895 | Supply, Installation, Testing and commissioning ofwall mounted panels constructed out of 2mm thick CRCA sheet duly powder coated as per specifications. The panel shall have hinged door with on-off interlocks. The panel shall be complete with incoming MCCB, suitable bus bars of aluminum construction, bus links complete with Star delta starter with \"hands\", \"off\", automatic modeselection switch, ammeter for each motor, timer, AutoManual switch, remote start/stop contacts, earthing connector etc.,as required complete as per specifications.Panel consisting of following:Indicating lights LED for incommer and outgoingAmmeter with selector switchVolt meter with selector switch with fusePanel With following Capacities: |
| 896 | 13ATP MPCB of suitable ratingwith 2.0 HP DOL PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate. MPCB shall be of 35KA |
| 897 | 25ATP MPCB of suitable ratingwith 3.0 HP DOL PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate. MPCB shall be of 35KA |
| 898 | 25A TP MPCB of suitable ratingwith 5.0 HP DOL PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate , Auto Manual Selector switch. MPCB shall be of 35KA |
| 899 | 25 A TP MPCB of suitable ratingwith 7.5 HP VFD PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver,Auto Manual Selector switch. MPCB shall be of 25KA |
| 900 | VFD forFan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. |
| 901 | 32 A TP MPCB of suitable ratingwith 10 HP VFD PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver,Auto Manual Selector switch. MPCB shall be of 25KA |
| 902 | VFD forFan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. |
| 903 | 63 A TP MPCB of suitable ratingwith 15 HP VFD PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver,Auto Manual Selector switch. MPCB shall be of 25KA |
| 904 | VFD forFan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. |
| 905 | 80 A TP MPCB of suitable ratingwith 20 HP VFD PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver,Auto Manual Selector switch. MPCB shall be of 25KA |
| 906 | VFD forFan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. |
| 907 | 125 A TP MPCB of suitable ratingwith 25 HP VFD PANELhaving overload relay in built single phase prevention, start / stop push buttons, phase indication lights with control MCB,on / off / tripindicationlightswith control MCB, digital ammeter with single CT & Voltmeter with selector switch,2C/O Control Relay with Control Thermostate & Suitable VFD Fan Louver,Auto Manual Selector switch. MPCB shall be of 25KAVFD forFan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. |
| 908 | ISOLATORS |
| 909 | Providing & fixing weather proof isolator with suitable rating near each unit, the prices should be inclusive of copper cabling from isolators to outdoor units. |
| 910 | POWER CABLE/CABLE TRAY |
| 911 | Supplyingand laying PVC/ XLPE insulated PVC sheathed heavy duty, armouredelectrical cables with Aluminium conductor for working voltage upto and including 1100volts ( conforms to IS:1554, Part-1) |
| 912 | 3.1/2 core300sq. mm. |
| 913 | 3.1/2 core 240sq. mm. |
| 914 | 3.1/2 core50sq. mm. |
| 915 | 3.1/2 core35sq. mm. |
| 916 | 3.5 core25sq. mm. |
| 917 | 4 core16sq. mm. |
| 918 | 4 core10 sq. mm. |
| 919 | Supplyingand laying PVC/ XLPE insulated PVC sheathed heavy duty, armouredelectrical cables with Copper conductor for working voltage upto and including 1100volts ( conforms to IS:1554, Part-1) |
| 920 | 4 core16 sq. mm. Stranded ( Copper) |
| 921 | 4 core10 sq. mm. stranded ( Copper) |
| 922 | 4 core6 sq. mm. stranded ( Copper) |
| 923 | 3 core4 sq. mm. stranded ( Copper) |
| 924 | 3 core2.5 sq. mm. ( Copper Control cable) |
| 925 | 3 core1.5 sq. mm. ( Copper Control cable) |
| 926 | Laying only one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required upto 35 sqmm to 95 sqmm(clamped with 1MM thick sadle ) |
| 927 | Upto 35 sq. mm |
| 928 | Above 35 sq. mm and upto 95 sq. mm |
| 929 | Above 185 sq. mm and upto 400 sq. mm |
| 930 | Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade. |
| 931 | 3.1/2 core 240sq. mm. |
| 932 | 3.1/2 core50sq. mm. |
| 933 | 3.1/2 core35sq. mm. |
| 934 | 3.1/2 core25sq. mm. |
| 935 | 4core16sq. mm. |
| 936 | 4 core10sq. mm. |
| 937 | 3/4 core16sq. mm.( Copper) |
| 938 | 3/4 core4 - 10sq. mm.( Copper) |
| 939 | 3 core1.5sq. mm.( Copper Control cable) |
| 940 | 3 core2.5sq. mm.( Copper Control cable) |
| 941 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Powder coated shall be of Siemens Grey Colour- RAL 7032) |
| 942 | 100mm width X 50mm depth X 1.6 mm thickness |
| 943 | 150mm width X 50mm depth X 1.6 mm thickness |
| 944 | 200mm width X 50mm depth X 1.6 mm thickness |
| 945 | Earthing Strip / Wires. |
| 946 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 947 | Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrde including connection/terminatng with GI nut,bolt,spring,washer etc as required.)jointing shall be done by overlapping &with 2sets of brass nuts bolt & spring washer spaced at 50mm) |
| 948 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 949 | AHU & MECH./ VENTILATION PANELS & BOARDS |
| 950 | Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type wall mounted extendible type power distribution boards/ Panels compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Copper Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. |
| 951 | MAIN MECH. & VENTILATION PANEL (ELECTRICAL ROOM) |
| 952 | INCOMING: |
| 953 | 1 No. TPNIncomer feeder having 1000A 4P MDO ACB (25kA) & ON/OFF/ TRIP indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 954 | BUSBAR: |
| 955 | One set of TPN, \"AL\" bus bar rated 1200 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 956 | OUTGOINGS: MCCB Ics-25kA & MCB as per specified |
| 957 | 3 Nos. TPN feeder having 320ATPN MCCB, ONindication with control MCB. |
| 958 | 2 Nos. TPN feeder having 250ATPN MCCB, ONindication with control MCB. |
| 959 | 1 Nos. TPN feeder having 200ATPN MCCB, ONindication with control MCB. |
| 960 | 1 Nos. TPN feeder having 160ATPN MCCB, ONindication with control MCB. |
| 961 | 8 Nos. TPN feeder having 100ATPN MCCB, ONindication with control MCB. |
| 962 | 2Nos. TPN feeder having 63A TPN MCCB, ONindication with control MCB. |
| 963 | Other items such as |
| 964 | 1 Lot of control wiring |
| 965 | 1 Set of designation plates |
| 966 | Complete panel Described as above. |
| 967 | AHU PANEL-1 LOCATION FOURTH FLOOR |
| 968 | INCOMING: |
| 969 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 970 | BUSBAR: |
| 971 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 972 | OUTGOINGS: |
| 973 | 9Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 974 | 6Nos. TPN feeder having 16A TPN MCB \"C\" curve with ON indication. |
| 975 | Other items such as |
| 976 | 1 Lot of control wiring |
| 977 | 1 Set of designation plates |
| 978 | Complete panel Described as above. |
| 979 | AHU PANEL-2 LOCATION FIFTH FLOOR |
| 980 | INCOMING: |
| 981 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 982 | BUSBAR: |
| 983 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 984 | OUTGOINGS: |
| 985 | 6Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 986 | 10Nos. TPN feeder having 16A TPN MCB \"C\" curve with ON indication. |
| 987 | Other items such as |
| 988 | 1 Lot of control wiring |
| 989 | 1 Set of designation plates |
| 990 | Complete panel Described as above. |
| 991 | AHU PANEL-3 LOCATION SIXTH FLOOR |
| 992 | INCOMING: |
| 993 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 994 | BUSBAR: |
| 995 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 996 | OUTGOINGS: |
| 997 | 5Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 998 | 5Nos. TPN feeder having 25A TPN MCB \"C\" curve with ON indication. |
| 999 | 4Nos. TPN feeder having 16A TPN MCB \"C\" curve with ON indication. |
| 1000 | Other items such as |
| 1001 | 1 Lot of control wiring |
| 1002 | 1 Set of designation plates |
| 1003 | Complete panel Described as above. |
| 1004 | AHU PANEL-4 LOCATION SEVENTH FLOOR |
| 1005 | INCOMING: |
| 1006 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1007 | BUSBAR: |
| 1008 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1009 | OUTGOINGS: |
| 1010 | 2Nos. TPN feeder having 40A TPN MCB \"C\" curve with ON indication. |
| 1011 | 4Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 1012 | 1Nos. TPN feeder having 25A TPN MCB \"C\" curve with ON indication. |
| 1013 | 5Nos. TPN feeder having 16A TPN MCB \"C\" curve with ON indication. |
| 1014 | Other items such as |
| 1015 | 1 Lot of control wiring |
| 1016 | 1 Set of designation plates |
| 1017 | Complete panel Described as above. |
| 1018 | MECH. VENTILATION PANEL-1(BASEMENT FLOOR) |
| 1019 | INCOMING: |
| 1020 | 1 No. TPNIncomer feeder having 63A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1021 | BUSBAR: |
| 1022 | One set of TPN, \"AL\" bus bar rated 100 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1023 | OUTGOINGS: |
| 1024 | 3Nos. TPN feeder having 40A TPN MCB \"C\" curve with ON indication. |
| 1025 | 1Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 1026 | 2Nos. TPN feeder having 25A TPN MCB \"C\" curve with ON indication. |
| 1027 | 5Nos. TPN feeder having 16A TPN MCB \"C\" curve with ON indication. |
| 1028 | Other items such as |
| 1029 | 1 Lot of control wiring |
| 1030 | 1 Set of designation plates |
| 1031 | Complete panel Described as above. |
| 1032 | MECH. VENTILATION PANEL-2(GROUND & MEZZ. FLOOR) |
| 1033 | INCOMING: |
| 1034 | 1 No. TPNIncomer feeder having 200A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1035 | BUSBAR: |
| 1036 | One set of TPN, \"AL\" bus bar rated 300 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1037 | OUTGOINGS: |
| 1038 | 6 Nos. TPN feeder having 63A TPN MCCB with ON indication & control MCB. |
| 1039 | Other items such as |
| 1040 | 1 Lot of control wiring |
| 1041 | 1 Set of designation plates |
| 1042 | Complete panel Described as above. |
| 1043 | MECH. VENTILATION PANEL-3(GROUND & MEZZ. FLOOR) |
| 1044 | INCOMING: |
| 1045 | 1 No. TPNIncomer feeder having 250A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1046 | BUSBAR: |
| 1047 | One set of TPN, \"AL\" bus bar rated 300 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1048 | OUTGOINGS: |
| 1049 | 10Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1050 | 2Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 1051 | Other items such as |
| 1052 | 1 Lot of control wiring |
| 1053 | 1 Set of designation plates |
| 1054 | Complete panel Described as above. |
| 1055 | MECH. VENTILATION PANEL-4(FIRST FLOOR) |
| 1056 | INCOMING: |
| 1057 | 1 No. TPNIncomer feeder having 315A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1058 | BUSBAR: |
| 1059 | One set of TPN, \"AL\" bus bar rated 400 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1060 | OUTGOINGS: |
| 1061 | 5Nos. TPN feeder having 63A TPN MCCB with ON indication & control MCB. |
| 1062 | 6Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1063 | Other items such as |
| 1064 | 1 Lot of control wiring |
| 1065 | 1 Set of designation plates |
| 1066 | Complete panel Described as above. |
| 1067 | MECH. VENTILATION PANEL-5(SECOND FLOOR) |
| 1068 | INCOMING: |
| 1069 | 1 No. TPNIncomer feeder having 250A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1070 | BUSBAR: |
| 1071 | One set of TPN, \"AL\" bus bar rated 300 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1072 | OUTGOINGS: |
| 1073 | 6Nos. TPN feeder having 63A TPN MCCB with ON indication & control MCB. |
| 1074 | 3Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1075 | Other items such as |
| 1076 | 1 Lot of control wiring |
| 1077 | 1 Set of designation plates |
| 1078 | Complete panel Described as above. |
| 1079 | MECH. VENTILATION PANEL-6(THIRD FLOOR) |
| 1080 | INCOMING: |
| 1081 | 1 No. TPNIncomer feeder having 315A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1082 | BUSBAR: |
| 1083 | One set of TPN, \"AL\" bus bar rated 400 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1084 | OUTGOINGS: |
| 1085 | 5Nos. TPN feeder having 63A TPN MCCB with ON indication & control MCB. |
| 1086 | 6Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1087 | Other items such as |
| 1088 | 1 Lot of control wiring |
| 1089 | 1 Set of designation plates |
| 1090 | Complete panel Described as above. |
| 1091 | MECH. VENTILATION PANEL-7(FOURTH FLOOR) |
| 1092 | INCOMING: |
| 1093 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1094 | BUSBAR: |
| 1095 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1096 | OUTGOINGS: |
| 1097 | 4Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1098 | Other items such as |
| 1099 | 1 Lot of control wiring |
| 1100 | 1 Set of designation plates |
| 1101 | Complete panel Described as above. |
| 1102 | MECH. VENTILATION PANEL-8(FIFTH FLOOR) |
| 1103 | INCOMING: |
| 1104 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1105 | BUSBAR: |
| 1106 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1107 | OUTGOINGS: |
| 1108 | 4Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1109 | Other items such as |
| 1110 | 1 Lot of control wiring |
| 1111 | 1 Set of designation plates |
| 1112 | Complete panel Described as above. |
| 1113 | MECH. VENTILATION PANEL-9(SIXTH FLOOR) |
| 1114 | INCOMING: |
| 1115 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1116 | BUSBAR: |
| 1117 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1118 | OUTGOINGS: |
| 1119 | 4Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1120 | Other items such as |
| 1121 | 1 Lot of control wiring |
| 1122 | 1 Set of designation plates |
| 1123 | Complete panel Described as above. |
| 1124 | MECH. VENTILATION PANEL-10(SEVENTH FLOOR) |
| 1125 | INCOMING: |
| 1126 | 1 No. TPNIncomer feeder having 100A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1127 | BUSBAR: |
| 1128 | One set of TPN, \"AL\" bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1129 | OUTGOINGS: |
| 1130 | 2Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 1131 | 3Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1132 | Other items such as |
| 1133 | 1 Lot of control wiring |
| 1134 | 1 Set of designation plates |
| 1135 | Complete panel Described as above. |
| 1136 | MECH. VENTILATION & STAIRCASE PRSS. PANEL (TERRACE FLOOR) |
| 1137 | INCOMING: |
| 1138 | 1 No. TPNIncomer feeder having 160A 4P MCCB (18kA) & ON/OFF indications, 3 nos. phase indicating lamps to show the incoming power with control MCB,1 no. multifunction meter (showing all parameters) with selector switch with matching cast resin CTs. |
| 1139 | BUSBAR: |
| 1140 | One set of TPN, \"AL\" bus bar rated 200 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1141 | OUTGOINGS: |
| 1142 | 4Nos. TPN feeder having 63A TPN MCB \"C\" curve with ON indication. |
| 1143 | 3Nos. TPN feeder having 32A TPN MCB \"C\" curve with ON indication. |
| 1144 | 2Nos. TPN feeder having 25A TPN MCB \"C\" curve with ON indication. |
| 1145 | Other items such as |
| 1146 | 1 Lot of control wiring |
| 1147 | 1 Set of designation plates |
| 1148 | Complete panel Described as above. |
| 1149 | LIFT |
| 1150 | POWER DISTRIBUTION BOARDS & PANELS |
| 1151 | Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor/ wall mounted, free standing extendible type power distribution boards/ Panels compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. |
| 1152 | LIFT PANEL - 1 Passenger LIFT |
| 1153 | 1 No. TPNIncomer feeder having 63A 4P MCCB (16kA) with ON indications, 3 nos. phase indicating lamps to show the incoming power with control MCB. |
| 1154 | Bus Bar |
| 1155 | One set of TPN, AL bus bar rated 100 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1156 | Goods lift |
| 1157 | Design supply, install, testing and commissioning goods lift, PRODUCTF-8000-3CO-30-8/8 (MR) |
| 1158 | Quantity of Lifts 2 Nos. |
| 1159 | CAPACITY (kgs) 8000 kgs (min) |
| 1160 | SPEED (mps) 0.5 mps |
| 1161 | RISE (m) 45000 mm |
| 1162 | STOPS 8 Stops – 8 Openings with openings on the same side |
| 1163 | FLOOR DESIGNATION B+G+6 |
| 1164 | CONTROLLER TYPEMicroprocessor based Control |
| 1165 | DRIVE VVVF |
| 1166 | POWER SUPPLY 415 Volts (3 Phase AC) |
| 1167 | OPERATION One call at a time. |
| 1168 | CAR GROUP Simplex |
| 1169 | MACHINE MRL Gearless (Located Above the Hoist way) |
| 1170 | TYPE Machine Room Type |
| 1171 | CAR FINISH:Rear Mid Panel = M S Powder coated, Rear Corner Panels = M S Powder coated,Side Panels = M S Powder coated,Front Panels = M S Powder coated |
| 1172 | VENTILLATION Cross flow fan |
| 1173 | FLOORING M.S. Chequared Plate |
| 1174 | CAR DOOR FINISH M S Powder coated |
| 1175 | LANDING DOORS FINISH M S Powder coated |
| 1176 | HOISTWAY DIMENSIONS (W x D – mm)5325 mm W x 6000 mm D |
| 1177 | CAR DIMENSIONS (W x D x H – mm) 3600 mm W x 4000 mm D x 3000 mm H |
| 1178 | CAR & HOISTWAY DOOR TYPE 6 Panel Center Opening (3CO) doors |
| 1179 | DOOR OPENING (W x H – mm)3600 mm W x 3000 mm H |
| 1180 | DOOR OPERATOR ACVVVF Door Operator |
| 1181 | Overhead5500 mm |
| 1182 | Pit Depth2000 mm |
| 1183 | COPstandard |
| 1184 | CAR POSITION INDICATOR standard |
| 1185 | HALL FIXTURE FACE PLATE S.S. Hairline Finish or equivalent |
| 1186 | HALL BUTTON ARRANGEMENT As per our standards in catalog |
| 1187 | STANDARD FEATURES: Independent Service, Overload Device,Door Nudging Operation, Emergency Car Light Unit,Infrared Curtain Door Protection, Emergency Alarm Button,Door Open/Close Button, Auto Fan Cut Off, |
| 1188 | TYPE/OPERATION SPECIFICATION |
| 1189 | ACVVVF GEARLESS GOODS ELEVATORS F-8000-3CO-30-8/8 (MR) |
| 1190 | POWER DISTRIBUTION BOARDS & PANELS |
| 1191 | Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor/ wall mounted, free standing extendible type power distribution boards/ Panels compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. |
| 1192 | LIFT PANEL 2 GOODS LIFT |
| 1193 | 1 No. TPNIncomer feeder having 100A 4P MCCB (16kA) withON indications, 3 nos. phase indicating lamps to show the incoming power with control MCB. |
| 1194 | Bus Bar |
| 1195 | One set of TPN, AL bus bar rated 150 Amps (after considering necessary deratingsof 75%) for phases and neutral for half capacity of phases. |
| 1196 | Outgoings:- All outgoing shall have Ics = 16 KA (As per SLD) |
| 1197 | 3 Nos. 63A TPN feeder having 63A TPN MCCB with ON indication. |
| 1198 | 1 Nos. 25A DP feeder having 25A DP MCB |
| 1199 | 1Nos. SPACE suitable for 63A 4P feeder having 100A 4P MCCB with ON indication. |
| 1200 | Other items such as |
| 1201 | 1 Lot of control wiring |
| 1202 | 1 Set of designation plates |
| 1203 | EOT CRANE |
| 1204 | Design,Manufacture,Supply,Installation,Testing & commisioning of10T/2T x 25M Span, 12m lift DGEOT Crane crab hoist with electrical & accessories. (CE Certified) (Dual Speed) |
| 1205 | Supply of DSL busbar along with current collectors and support brackets suitable for 10/2T DGEOT Crane (RYBG) for the bay length of 38 meter.Baylength – 38 meters |
| 1206 | Supply of LT Rail suitable for 10/2T Double Girder EOT crane |
| 1207 | FIRE SUPPRESSION SYSTEM |
| 1208 | SITC of Aerosol generator having aerosol mass of suitable gm shall be thermally actuated by means of aluminium alloy thermal sensor complying to UL 33 that can be mounted over the generator itself. The housing shall be constructed of stainless steel shell.Housing shall be sealed with a non-permeable membrane. Units shall have passed salt spray corrosion testing per relevant UL Standard as part of their listing. Aerosol generated shall be potassium based. Agent shall have no ozone depletion potential and no global warming potential. Agent shall be listed by the US EPA under the SNAP program. Fixed Condensed Aerosol Systems per NFPA 2010. UL approved design density of the aerosol should be less than 100g/cu.mtr for Class A, B & C fires as per NFPA. The Aerosol generator should have self life of 15 years. Aerosol generator shall be supplied with Stainless steel Bracket & Thermal Sensor.Makes Approved: STAT-X, MAC, Epotos |
| 1209 | 11KV VCB PANEL BOARD |
| 1210 | 750KVA DG SET |
| 1211 | SMART ACTIVE HARMONIC FILTER (SAHF) with 500A & 700KVA |
| 1212 | MAIN LT PANEL |
| 1213 | MAIN LIGHT & POWER PANEL (ELECTRICAL ROOM) |
| 1214 | FDB-1. |
| 1215 | FDB-2. |
| 1216 | FDB-3. |
| 1217 | FDB-4. |
| 1218 | FDB-5. |
| 1219 | FDB-6. |
| 1220 | FDB-7. |
| 1221 | FDB-8. |
| 1222 | FDB-9. |
| 1223 | FDB-10. |
| 1224 | FDB-11. |
| 1225 | FDB-12. |
| 1226 | FDB-13. |
| 1227 | MAIN MECH. & VENTILATION PANEL (ELECTRICAL ROOM) |
| 1228 | AHU PANEL-1 LOCATION FOURTH FLOOR |
| 1229 | AHU PANEL-2 LOCATION FIFTH FLOOR |
| 1230 | AHU PANEL-3 LOCATION SIXTH FLOOR |
| 1231 | MECH. VENTILATION PANEL-1 (BASEMENT FLOOR) |
| 1232 | MECH. VENTILATION PANEL-2 (GROUND & MEZZ. FLOOR) |
| 1233 | MECH. VENTILATION PANEL-3 (GROUND & MEZZ. FLOOR) |
| 1234 | MECH. VENTILATION PANEL-4 (FIRST FLOOR) |
| 1235 | MECH. VENTILATION PANEL-5 (SECOND FLOOR) |
| 1236 | MECH. VENTILATION PANEL-6 (THIRD FLOOR) |
| 1237 | MECH. VENTILATION PANEL-7 (FOURTH FLOOR) |
| 1238 | MECH. VENTILATION PANEL-8 (FIFTH FLOOR) |
| 1239 | MECH. VENTILATION PANEL-9 (SIXTH FLOOR) |
| 1240 | MECH. VENTILATION PANEL-10 (SEVENTH FLOOR) |
| 1241 | MECH. VENTILATION & STAIRCASE PRSS. PANEL (TERRACE FLOOR) |
| 1242 | LIFT PANEL 1 PASS. LIFT |
| 1243 | LIFT PANEL 2 GOODS LIFT |
| 1244 | FIRE ALARM & PUBLIC ADDRESS SYSTEM |
| 1245 | Supply & installation of Networkable & Microprocessor based 160‐ characters LCD/ Touch Screen LCD DisplayNetwork Repeator panel. The LCD shall Display all events / detectors, devices status of complete systems in the networked, The repeator shall be equipped with Mounting options etc. (ULApproved) complete in all respect as specified or indicated including testing on completion. |
| 1246 | Supplying & laying of cabling for fire detection and alarm system with 2 core annealed tinned copper conductor Fire Survival, 2 x 1.5 sq mm armoured cable complete in all respect as specified or indicated including testing on completion. |
| 1247 | Supplying & laying of 8 Core 1.5Sq MM wire from Main Fire Alarm Panel to Repeater Panel complete in all respectas specified or indicated including testing on completion. |
| 1248 | SOLAR SYSTEM |
| 1249 | 75KW SOLAR SYSTEM SUPPLY & Installation |
| 1250 | 234 sets : Supply, Installation, testing & Commissioning of solar module,necessary electrical cables to connect solar cells together and to the DB\"s as well as inverters to havea complete operational circuit, Conduits, cable trays, trucking, earthing system and complete Main Junction Box according to the drawings and engineer\"s instruction and approval. quoted rate deemed to include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected and costs of repairing if any damaged works including following:- |
| 1251 | 1 Lot: Supply, Installation, testing & Commissioning of Module mounting Structure according to the detailed drawing and approval by the Engineer. Contractor should submit shop drawing for proper mounting structure. Rate shall include aluminium anodized/ HD galvanized structure, supports, plates & screws, bracing and angles for dividers etc to complete the structure. quoted rate deemed to include excavation, concreting and fixing of structure. |
| 1252 | 3 Set: Supply, Installation, testing & Commissioning of 25kW/30KW1P grid tie inverter with minimum 2 MPPT inputs. The inverter depending on the system design and installation proposed. The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be oftype DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factor outdoor, minimum AC output power 180 kw, with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed toconnect with the main distribution panel according according to the drawings andengineer\"s instruction and approval and have a complete job ready. |
| 1253 | 3 Set: Supply, install, connect and operate 20KA DC SPD DC surge protector for grid connected system . The Surge protector unit shall be suitable for indoor and outdoor installations. The surcharge protector system shall include all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to the system according to the drawings andengineer\"s instruction and approval and have a complete job ready. |
| 1254 | Solar system power connect at Main LT panel Bus, 200A MCCB provided to terminate solar plant cabling. |
| 1255 | DG SET |
| 1256 | Supply, Installation, testing & commissioning of 750 KVA DG coupled to 750 KVA alternator as per detailed specifications, with canopy reducing the noise to 75 db at a distance of 1meter as per specifications & latest CPCB -II norms with following:-. |
| 1257 | Base frame and DG shall have radiator. |
| 1258 | DG shall be suitable for paralleling |
| 1259 | Gerb make antivibration pads. |
| 1260 | Electronic governor with communication port. |
| 1261 | Day tank/ base tank for fuel with level markings inside canopy |
| 1262 | All lockable doors having brass handles. |
| 1263 | Front shall have perspex sheet to indicate fuel guage & ECP Panel along with one emergency push button out side canopy. |
| 1264 | Fuel piping from internal tank shall be brought O/side canopy & connected for gravity feed to common external tank. |
| 1265 | Suitable space heater for alternator. |
| 1266 | Lub oil drain arrangement. |
| 1267 | Canopy to have required size blower for cooling as well as air combustion. (Calculation for blower shall be submitted along with drawing) |
| 1268 | Canopy temperature shall not rise beyond 70 C above ambient and necessary temperature gauges will be installed. |
| 1269 | Suitable amended alternator cable box with sufficient space for flexible lads/ cores of 5 x 3.5C x 300 sq. mm armoured XLPE AL cables and also suitable arrangement for 5 nos. Cable exit with proper arrangement/ provision for mounting/ fixing double compression glands on alternator cable box. |
| 1270 | Provision in the canopy for taking out silencer, control cables & power cables in proper manner in such a way that after commissioning no foreign material like water, insect, reptile can entre from these cut-outs. |
| 1271 | Suitable self priming pump with engine (if inbuilt by the manufacturer). |
| 1272 | Provision in the canopy for taking out 3 runs XLPE AL armoured cables along with control cables. Cable box on top of alternator shall be modified to take out 3 nos. 3.5C alm. arm. cables with proper arrangement/ provision for mounting/ fixing double compression glands on alternator cable box from bottom/ side. |
| 1273 | Maintenance free battries with leads & connectors complete with mounting arrangement & protection switchgears. |
| 1274 | DG shall be completely filled with luboil & fuel required for commissioning and trial run for 2 hrs. |
| 1275 | Supply, designing, fabrication and installation ofexhaust pipe of DG sets along with exhaust stack including two coats of red oxide and one coat afterward with high temperature resistance paint as per the approved colour / existing stack colour. Before fabricating, the contractor has to get the design approved from the Project Manager/consultant. The exhaust structure shall be suitable for 1 Nos. 750 KVADG sets. Stack shall be installed along the wall & above terrace level as per standard norms. |
| 1276 | EXHAUST SYSTEM |
| 1277 | Supply, erection, testing and commission of MS 300 mm dia exhaust system minimum 4.85 mm thick with complete bends & flanges and all accessories complete in every way. |
| 1278 | Supply and installation of 300 mm dia SS flexible bellows with matching flanges along with required hardware i.e. gasket, nut bolt, washer etc as required. |
| 1279 | Insulation of pipe 300 mm dia with RBS wool of min 50mm. thickness 148 Kg/ m3 density and 24 SWG Alm cladding inside & outside DG room complete. Insulation will be done in such a way that temperature surrounding it shall not exceed 5O C beyond ambient. |
| 1280 | Fuel piping |
| 1281 | Supply, installation of fuel pipe between common existing HSD fuel tank to fuel tanks inside 750 KVA SDG inclusive all fitments / bends / accessories/ valves etc including level gauges of following sizes:- |
| 1282 | 38/40 mm fuel pipe |
| 1283 | 20mm fuel pipe |
| 1284 | 25mm fuel pipe |
| 1285 | Erection, installation, testing & commissioning of 990 ltr. overhead raised buffertank M.S diesel tank manufactured with 2mm thick MS sheet complete with manholes cover, drain valve, marking along with M.S structure (bottom of tank at 0.6 meter high) with inbuilt flame proof level switches inside. |
| 1286 | CCTV SYSTEM |
| 1287 | Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS Vandal-proof, Network Dome Camera (1280 × 960) resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch, IR range up to 30 RM, H.264 / MJPEG, Dual stream, motion detection, Bit rate 32 Kbps-16Mbps, 3D DNR, DWDR, 12 VDC ± 10%, PoE , IP66, K-10, with fixed lens between(2.5 - 12mm),size of lens shall be as per site requirement & mockup. ONVIF, SIP, NMS, Profile S supported, connectors complete as required in dome shape fixed type for mounting recessed in false ceiling or mounted on wall complete as required. |
| 1288 | Supply, installation, testing and commissioning of UL Listed 1.3 Megapixel CMOS, Vandal-proof, Network Bullet Camera,(1280x960) resolution, 1/3” Progressive scan CMOS, [email protected], AGC ON. 0 Lux with IR on, IR cut filter with auto switch,, H.264 / MPEG4 , Dual stream, Bit rate 32 Kbps-16Mbps, Standard IP66, PoE , with Fixed Lens between(2.5 - 12mm),size of lens shall be as per site requirement & mock-up ,IR range Up to 50 mtr, motion detection, withONVIF, SIP, NMS,Profile S supported, connectors complete as required IR Bullet fixedtype for mountingon wall or surface mounted with back box and adapter plate complete as required. |
| 1289 | Supply, installation, testing and commissioning of Professional Video management and recording software and hardware comprising 32Ch. NVR to record output of all cameras mentioned above in Item no 1,2,3 Third-party network cameras supported, H.264 Compression - Up to 5 Megapixels resolution recording, multiple Hard Disk 8 SATA with each having maximum storage capacity of 6 TB , as required for minimum 30 days recording required for recording when in 80% motion @ 720p 25 Frames per second(Real Time) or for recording when not in motion @720p 12.5 Frames per second, with RAID-5 Storage ,10/100/1000 MBps network interface with each NVR, 2 USB2.0,HTTP Networkable, backupby USB/DVDWR, required Client software included, 6 Nos Client licenses and required Camera licenses for each camera completeas required. All the components to be of same make as Camera. |
| 1290 | Supply,installation,testing and commissioning of32” CCTV colour LED screen including all accessories complete as required. |
| 1291 | Supply, installation, testing and commissioning ofLayer 2 switchHP/ Cisco make with 32 ports PoE managed, 10/100/1000 EB core switches to support all IP cameras & Access Control System , with 2 Fibre uplinks Portmodule only complete as required. |
| 1292 | Supplying and installation of 19\" 32U APW President Rack with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate systems equipment and accessories as mentioned in the BOQ above and including all connections and terminations as required. |
| 1293 | Supply, Installation, Testing & Commissioning of 6TB Hard Disk storage system |
| 1294 | Supply , installation , testing and commissiong of Weather proof junction box for outdoor cameras |
| 1295 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required |
| 1296 | Subtotal |