| 1 | SH:I (OCM of EMS) |
| 2 | Providing operation and Comprehensive Maintenance of followingElectro- mechanicalservicesincluding monitoring, managing the operation of the Electro- mechanical services by deploying suitable sufficient personnel to fulfill the SLA parameters, etc. to maintain uninterrupted operation of EMS services as per given terms and conditions. The EMS is as per the size of services attached. |
| 3 | Pump sets i/c Panel/board |
| 4 | Compound-Lighting |
| 5 | Common area lighting |
| 6 | Minor components of E.I. |
| 7 | NOTE:- |
| 8 | 1) Contractor to take all steps to undertake preventive/special maintenance and testing to keep the system at optimum working condition. |
| 9 | 2) Engineer-in-charge can rearrange timings of deployment as per site requirement and site conditions. |
| 10 | 3) In case of Non-Compliances, recoveries shall be applicable as per the relevant terms & conditions. |
| 11 | 4) Wherever additional manpower required for carrying out the work of opeation and repair/ maintenance, the same shall be arranged by the firm at no extra cost. |
| 12 | 5) Minor material for common areas such as 6A Switch/Socket/ 15A Switch/Socket/Starter/Starter holder/ Side Holder i/c fiber base//Fan Capacitor//Fan Canopy/ Angle holder/ BattenHolder/ Ceiling rose/ Bell push/Bell Buzzer/Gang Box 2/4 way/ Flourescent Tube Rod has to be arranged by contractor without any extra cost. |
| 13 | 6) The minor materials for inside of Staff Quarters shall be same as 5) above except the Flourescent tube rods. |
| 14 | 7) The Common areas shall include all areas except the inside of Staff Quarters. |
| 15 | For Staff Quarter at RK CIT Colony |
| 16 | SH: II (EI & Fans) |
| 17 | Supplying & fixing of following material on need basis / call basis for repairing & attending breakdown maintenance work for repairing ofelectrical items like fluorescent fitting, ceiling fans, Main board, Sub Main board etc i/c dismantling, reconnection, testing, commissioning etc as required. |
| 18 | NOTE- |
| 19 | 1) The required suitable manpower for carrying out the work of repair/replacement/breakdown maintenance shall be arranged by the firm at no extra cost. |
| 20 | (2) The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory) |
| 21 | Step type Electronic Fan Regulator |
| 22 | Electronics choke for 36W FTL fitting |
| 23 | DP switch - 32 A |
| 24 | 3 mm thick hylam sheet |
| 25 | Door Bell (Chime) |
| 26 | Single pole - 6A to 32 A |
| 27 | Single pole and neutral - upto 32A |
| 28 | TPN MCB- 63A |
| 29 | Isolator 4P - 63A |
| 30 | Isolator 4P - 100A |
| 31 | 20W LED Batten |
| 32 | 9w LED Bulb - Pin type (B-22) |
| 33 | 1 x 1.5 sqmm PVC insulated copper wire i/c making connections |
| 34 | 1 x 4 sqmm PVC insulated copper wire i/c making connections |
| 35 | 1 x 6 sqmm PVC insulated copper wire i/c end termination and making connections |
| 36 | 1 x 10 sqmm PVC insulated copper wire i/c end termination and making connections |
| 37 | Supply of2x6 Sqmm Al aromured UG Cable |
| 38 | Supply of 4x25 Sqmm Al armoured UG Cable |
| 39 | Laying and fixing of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade upto 35 Sq.mm size (clamped with 1mm thick saddle) on wall surface as required. |
| 40 | Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade upto 35 Sq.mm size direct in ground i/c excavation,refilling the trench and making good the surface as required. |
| 41 | Supplying and making end terminationwith brass compression gland and aluminium lugs for 4x16 Sq.mm(28 mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 42 | Supplying and making end terminationwith brass compression gland and aluminium lugs for 4x25 Sq.mm(28 mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 43 | 32A Procelain fuse carrier with base |
| 44 | 63A Procelain fuse carrier with base |
| 45 | Supply and fixing of 3 star rated 48\"/1200mm ceiling fan, in the existing fan hook with necessary connections etc. as required. |
| 46 | Supply and fixing of50W LED Street light fitting made up of pressure die cast housing with toughened glass and high power LED\"s with secondary optics and IP 66 protectionwith necessaryconnections in the existing pole etc.as required. |
| 47 | Overhaulingand servicing of ceiling fan/exhaust fanincluding disconnection & dismantling, cleaning, replacing worn out parts like bearing, quarter pin, lock nuts, rubber bush, refixing, etc.as required. |
| 48 | Rewinding of ceiling fan including disconnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required. |
| 49 | Rewinding of exhaust fan including disconnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required. |