| 1 | S&F in repairs starting capacitor of cap 80/100 MFD 440 Volts Air Conditioner & fixing in position testing etc complete all as specified and directed. |
| 2 | S & F in repairs running capacitor of cap 36/45 MFD 440 V AC & fixing in position testing etc complete all as specified and directed. |
| 3 | S& F in repairs over load relay suitable for AC split 1.5 ton & fixing in position & testing etc complete all as specified and directed. |
| 4 | S & F in repairs thermostat suitable for AC split type 1.5 ton fixing in position etc complete all as specified and directed. |
| 5 | S & F in repairs thermostat suitable for AC split type 2ton fixing in position etc complete all as specified and directed. |
| 6 | M & L for refrigerant gas charging with R-22 suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed. |
| 7 | S & F in repairs sealed/unit compressor with full charging of gas F-12/ R-22 factory winded ( Make : Kirloskar/Shriram or equivalent) suitable for AC 1.5 /2 Ton split type or equivalent including transporting tocivil work shop & bring back at site & fixed in position & testing etc all as specified and directed. |
| 8 | S & Ffan motor 230 V suitable for AC 1.5 ton split type complete all as specified and directed. (any capacity) |
| 9 | S & Ffan motor 230 V suitable for AC 2 ton split type complete all as specified and directed. ( any capacity ) |
| 10 | S & F in repairs filter element suitable for AC 1.5 ton Split type of any make complete all as specified and directed. |
| 11 | S & F in repairs filter element suitable for AC 2 ton Split type of any make complete all as specified and directed. |
| 12 | S & F in repairs blower unit for A/C 1.5 ton,/2 Tonof split type complete all as specified and directed. |
| 13 | S& F in repairs remote control suitable for AC split type cap 1.5 ton, 2ton & 3 ton of split type complete all as specified and directed. |
| 14 | M & L for disconnecting unserviceable and corroded top cover of AC split type outer unit of any capacity including replacement with new top cover made out of 02 mm thickMS CRC sheet with necessary bolt, nuts & washers duly painted as per existing complete all as specified and directed. |
| 15 | S&F in repair PCB circuits for ACs 1.5, 2 TR complete all as specified and directed. |
| 16 | S&F in repair PCB circuits(outer unit PCB) for inverter base AC cap 1.5/2 TR outer unitcomplete all as specified and directed. |
| 17 | M & L for disconnecting outer & inner unitof Air-conditioning unit of any capacity including cutting of copper tubes including shifting of outer unit from roof of the building with provision of angle iron anchor pockets made out of25mmX25mmX5mm angle iron with suitable size of MS plate with installation of outer & inner unit of AC with the suitable space for further maintenance including necessary gas charging / topping up R-22 with soldering of copper tubes complete all as specified and directed. |
| 18 | S & F in repairs sealed unit compressor with full charging of gas F-12/R134 factory winded suitable for refrigerator 185 ltrs capacity of any make carrying out incivil work shop and bringing itback to site,fixing & testing complete all as specified and directed. |
| 19 | M & L for gas charging with F-12/F-22 or equivalent suitable for refrigerator capacity 165/250/310 Ltrs including cutting of copper tubes soldering & fixing in position complete all as specified and directed. |
| 20 | M & L for gas charging with F-12/F-22 or equivalent suitable for deep freezer of various capacityincluding cutting of copper tubes soldering & fixing in position complete all as specified and directed. |
| 21 | S & F in repairs sealed unit compressor with full charging of gas F-12/ R134 factory winded of capacity 40/60/80 ( Make Kirloskar / Shriram or equivalent) Model 444, 512, 2612 or equivalent carryingout in civil work shop & bringing back to site & testing for water cooler complete all as specified and directed. |
| 22 | S & F in repairs fan motor 230V single phase 1440 RPM suitable for water cooler 40/60/80 Ltrs and fixing in position etc complete all as specified and directed. |
| 23 | S&F in repairs starting capacitor 80/100 MFD 440- V suitable for water cooler any capacity and fixing in position testing etc complete all as specified and directed. |
| 24 | S & F in repairs capacitor 36 MFD 440 V suitable for water cooler any capacityfixing in position testing etc complete all as specified and directed. |
| 25 | S&F in repairs over load relay suitable for water cooler fixing in positiontesting etc complete all as specified and directed. |
| 26 | M & L for repairs to water cooler body of any capacity including cutting of corroded portion of MS sheet and making new with MS CRC sheet 22SWG for bottom portion and 24 SWG for upper/body portion,repairing of standincluding painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | S & F in repairs 15mm ball valves high pressure with polythene floatvalve and fly nuts complete screwed for iron pipe & fixed for water cooler any capacity complete all as specified and directed. |
| 28 | S & F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwedboth ends for iron pipes for union & fixed of size 15 mm bore complete all as specified and directed. |
| 29 | M & L for refrigerant gas charging with R-12, R-22 or equivalent for water cooler capacity of 40/60/80 Ltrs cap including cutting of copper tubing & soldering etccomplete all as specified and directed. |
| 30 | M & L for taking out old unserviceablethermostat from water cooler, supply and fix thermostat complete all as specified and directed. |
| 31 | M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 5 KVA capacity complete all as specified and directed. |
| 32 | M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 2 KVA capacity complete all as specified and directed. |
| 33 | M & L for taking out old unserviceablevolt meter/ amp meter and Supply & fixvolt meter/ amp meterfor single phase voltage stabilizer complete all as specified and directed. |
| 34 | M &L for rewinding of fan motor any make any size of desert cooler with super enameled copper wire using with suitable gauge including materials such as insulating paper, varnishing, heating/baking and reassembling testing complete all as specified and directed. |
| 35 | S & F in repair of fan motorincluding cutting dismantling from desert cooler any size as per site complete all as specified and directed. |
| 36 | S & F in repairs vertical pump for desert cooler with GI clamps suitable Upto 5 feet height discharge coolers etc complete all as specified and directed. |
| 37 | S & F in repairs capacitor 4 MFD suitable for desert cooler of any capacity & testing etc complete all as specified and directed. |
| 38 | S & F in repairs selector switch for smooth operation of desert cooler of any capacity fixing & testing etc complete all as specified and directed. |
| 39 | S & Fsuitable pad / grass ribs including packing complete set of three for each cooler complete all as specified and directed. |
| 40 | S & FPVC flexible pipe 15 mm bore suitable to desert cooler any capacity for circulation of water etc complete all as specified and directed. |
| 41 | S & Fplug top 5 Amp for electric connection of desertcooler etc complete all as specified and directed. |
| 42 | S & Fplug top 15 Amp for electric connection for water coolers, deep freezers etc. complete all as specified and directed. |
| 43 | S & F for ply wood 6 mm thick including painting with two coats of synthetic enamel paint over one coat of primer onone side fixing to window face complete wherever required for desert cooler etc complete all as specified and directed. |
| 44 | M & L for preparation of old surface of desert cooler any make any sizeinternally & externally complete body both internal & external surface with two coats of synthetic enamel paint gray shade over one coat of red oxide primer complete all as specified and directed. |
| 45 | S & F in repair including cutting dismantling desert cooler bottom water storage tank with primer & painting of tank cap upto 80 litre complete all as specified and directed. |
| 46 | S & F in repairs PVC copper cable 1.5 sqmm three core for connection of desert cooler complete all as specified and directed. |
| 47 | S & Fsingle pole with a two pin & earth plug & socket complete with one single pole MCB of capacity 20 Amp complete all as specified and directed. |
| 48 | M&L for split AC\"s checking /rectification of minor problem including washing,cleaning of outer/inner unit with filter by brushes & servicing of inner & outer unit etc complete all as specified and directed. |
| 49 | M & L for refrigerant gas charging with 410-C( gas green) suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed. |
| 50 | M& L for capillary tube 0.060 inch,0.064 inch & 0.072inch suitable for 1.5 TR & 2TR AC as directed by Engineer -in charge complete all as specified and directed. |
| 51 | S&F in repair thermostat for geyser capacity upto 25 ltrs complete all as specified and as directed. |
| 52 | S&F in repair heating element forgeyser capacity upto 25 ltrs complete all as specified and directed. |
| 53 | S&F in repair temperature and pressure valve for geyser capacity upto 25 ltrs complete all as specified and as directed. |
| 54 | S&F isolator switch forgeyser capacity upto 25 ltrs complete all as specified and directed. |
| 55 | S&F an overflow pipe forgeyser capacity upto 25 ltrs complete all as specified and directed. |