| 1 | STREET LIGHT POLE & LED STREET LIGHT |
| 2 | Providing and erection of 7.0 Mtr height hot dipped galvanized octagonal poles as per IS 2713 – 1980 (part I & II) ISI mark in single section made from 3mm thick sheet with top dia 70 mm and bottom dia 130 mm and base plate of size 200 x 200 x 12 mm,having 4 nos. 20 mmdia 600 mm long \"J\" typefoundation bolts on pitch circle dia 200 mm, projected bolt length above pitch 100 mm, complete with lockable weather proof flush door junction box fitted at atlest 0.5 to 1 Mtrs above from the bottom of the pole, bakelite sheet of 10mm thick consisting of one MCB 25Amp SP & 16sq.mm stud type 4 way epoxy connector alongwith sword canopy type single arm GI bracket upto 2 meter Long for 70mm A/F top including designing and construction ofRCC M-20 (1:1.5:3) footing foundation for octagonal pole of size 0.4 m x 0.4 m x 0.8 m including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick with minimum 8 nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm C.C. for fixing the pole including 2 Nos 50 mm dia DWC/ HDPE pipe of length 1.16 Mtrs inside the collar/foundation for cable entry duly finished with cement plaster huttering, curing etc. with all labour & material required to complete as per specifications in an approved manner as per manufacturer drawing (Make: Philips/ Bajaj/ Surya/C&S and other reputed makes with prior approval of BSF) |
| 3 | Providing & Fixing ofIP 66 protected 120 watt LED Street Light Luminaire made of powder coated single piece pressure die cast aluminummaterial with heat dissipation housing with UV stabilized PC/ Toughened Glass cover (UV stabilization report submitted for UV cover) and secondary lens on each LED &with 5 years free replacement guarantee including providing necessary connection with 3 core 1.5 sqmm copper cable. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique voltage 120 to 220V AC withFrequency 50Hz ± 3% Power Factor The luminaire shall be BIS certified andLife Expectancy Equal or more than 5 years with Minimum 70% lumen maintained, of make C&S/Philips/ Surya/ Bajaj/ Havells. |
| 4 | STREET LIGHT POLE & LED STREET LIGHT |
| 5 | Supplying and laying of one number XLPE insulated and PVC sheated power cable of 1.1 KV grade, A2XFY of following size as required.(4 CX 25 Sqmm) |
| 6 | Supplying and laying of one number XLPE insulated and PVC sheated power cable of 1.1 KV grade, A2XFY of following size as required.(3.5 CX 120 Sqmm) |
| 7 | Providing and laying and fixing 100 mm dia medium class duty GI pipe complte with GI Fitting0.75 mtr below ground for crossing of cable in the cc pavment i/c repairing etc complete as required. |
| 8 | Supplying and fixing cable route marker with Cable route marker with 10CM X 10 CM X 5 MM thick G.I plate with inscription there on,bolted/welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 9 | suppliying and making end termination with brass compression gland and aliminium lugs for following size PVC insulated and PVC sheathed/ XLPEAluminium conductor cable of 1.1 KV grade (A) 4 C x 25 sqmm (28 mm) |
| 10 | suppliying and making end termination with brass compression gland and aliminium lugs for following size PVC insulated and PVC sheathed/ XLPEAluminium conductor cable of 1.1 KV grade (B) 3.5 C x 120 sqmm (45 mm) |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc,conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (A) 63 mm dia (63 mm & ID-51 normal) |
| 12 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc,conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (B) 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 13 | FEEDER PILLAR |
| 14 | Fabrication, Supplying, installation, testing & commissioningof outdoor canopy type double door main feeder panel of size 1200mmx 900mm x 450 mm made out of 14 SWG thick CRCA sheet suitable for 415V, 3 phase, 4 wire 50 Hz. A.C. supply system, cable alleys on both sides to accommodate following switch gears & accessories, fabricated in compartmentalized (Preferably) having front area not less than 1.10 Sqmtr. and 450 mm deep nominal size design from CRCA sheet steel of 2mm thick for frame work and covers with locking arrangement, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 300 amp capacity extensible type TPN aluminum alloy bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 50mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of al. bus bars and control wiring with suitable size PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two half,MS angle iron base frame duly welded 600mm long welded with 4 Nos legs for grouting in foundation i/c Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 40mm nominal size) foundation (400mm below the ground level and 200 mm above the ground level) it should be covered with Aprin plate not less than 3 mm thick i/c providing following switch gears etc. complete as required. (Incomer and outgoing as mentioned in NIT) Page no. 18 to 22 |
| 15 | Fabrication, Supplying, installation, testing & commissioningof outdoor type Double Door main feeder panel of size 900mmx 800mm x 450 mm made out of 14 SWG thick CRCA sheet suitable for 415 Volt, 3 phase, 4 wire 50 Hz. A.C. supply system, cable alleys on both sides to accommodate following switch gears & accessories, fabricated in compartmentalized (Preferably) having front area not less than 1.10 Sqmtr. and 450 mm deep nominal size design from CRCA sheet steel of 2mm thick for frame work and covers with locking arrangement, 3mm thick for gland plates i/c cleaning & finishing complete with powder coating in approved shade, having 300 amp capacity extensible type TPN aluminum alloy bus bar supports, bottom base channel of MS section not less than 50mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of al. bus bars and control wiring with suitable size PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two half,MS angle iron base frame duly welded 600mm long welded with 4 Nos legs for grouting in foundation i/c Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 40mm nominal size) foundation (400mm below the ground level and 200 mm above the ground level) it should be covered with Aprin plate not less than 3 mm thick i/c providing following switch gears etc. complete as required.(Incomer and outgoing as mentioned in NIT) Page no. 18 to 22 |
| 16 | Fabrication, Supply, installation, testing and commissioning of cubicle type feeder pillar (joint box) of size 600mmx 450mm made out of 16 SWG thick CRCA sheet, floor mounted with 600 mm long 04 nos. legs made out of 35 mm x 35 mm x 5 mm thick angle, outdoor type, dust proof, water proof, front door open able, having hinged cover , lockable gate and rain protection canopy cover at top complete with 04 nos. bus-bars of 100 amps capacity, feeder pillar shall be suitable for 3 phase, 415 volt AC supply including civil foundation with 1:3:6 cement concrete & trench (Bricks, Cement, Sand and concrete etc. for making foundation & trench) etc. as required. |
| 17 | Supplying, installation, testing and commissioning of Astronomical time switch suitable for 3 output (1 output per phase) and suitable for three phase supply configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 18 | FEEDER PILLAR |
| 19 | Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 20 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 21 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 22 | Painting with aluminum paint with approved brand and manufacture of required colour to given even shade. Two or more coat for even shade. |
| 23 | Removing of exiting paint by scrapping and sand papering and preparing the surface smooth including necessary repair to scratches etc complete. |