| 1 | NON CLOG SEWAGE SUBMERSIBLE PUMP SET Discharge 800 m³/hr.,HEAD: -28 MTR,Rating 112/150, OUTLET SIZE OF PIPE 250 mm dia, Cable- 2 x50 sqmm x 3.50 core + 1.50 sqmm x 4.0 core. |
| 2 | S/L of Al. conductor PVC insulated armoured served, sheathed cable 1100 V grade at a depth of below ground level over a cushion of 75mm below ground level over a cushion of 75mm thick sand alround protected with burnt brick on sides and on top. On surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by E/I complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 95 sqmm 3½ core |
| 3 | 185 sqmm 3½ core |
| 4 | 240 sqmm 3½ core |
| 5 | 400 sqmm 3½ core |
| 6 | Design , supply, Erection, Testing and commissioning of MCC(Motor Control Centre) Panel made out of 14-16 SWG.CRCA sheet Powder Coated paint after degreasing drusting & vermin Proof free standing front operated Cubical pannel board suitable for 415 volt 50 HZ system with the following incomimg and outgoing complete:- Incoming:-3 Nos. 1600 Amp.three pole air circuit breaking (suitable to take two supply) Electrically & Mechanical inter locking So that the one time two source does not come on one feeder to make the system foult free 1600/5 Amp. C.T. ratio with 0-1600 Amp. Ammeters, 0-500 V voltmeter, ASS,VSS,phase Indication light with one set of C.T. and control fuse etc. Outgoing:- 2 Nos of 800 ACB, 8 Nos, 250 Amp MCCB with ampere meter, current Transformer, Ampere Selector Switch etc. 06 nos. 125 MCCB for lighting and external use. |
| 7 | (make:- ACB-L&T/Schnider/ABB, MCCB/Changeover-L & T / Schnider /ABB Meter-L&T/A.E. Selector Switch-L&T. Current Transformer-A.E.) (1600 Amp ACB-3 Nos, 800 Amp. ACB-2 Nos, 250 amp MCCB-8Nos,100 amp MCCB-6 Nos, Ampere Meter--18 Nos, Volt Meter-2 Nos, C.T. 150/5 - 18 Nos, C.T. 250/5 - 24 Nos, C.T. 800/5 - 6 Nos, C.T. 1600/5 - 6 Nos, A.S.S- 18 Nos, V.S.S-2 Nos.) Suitable for up to 250 HP Motor All as per Required As per approved Deisgn and Drawing by E/I. |
| 8 | S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respect as per direction of E/I.70 Sqmm |
| 9 | 95 Sqmm |
| 10 | 120 Sqmm |
| 11 | 240 Sqmm |
| 12 | 400 Sqmm |
| 13 | P/F Reflex Valve upto 600 mm dia shall conform to IS 5312 Part 1 & above to IS 5312 Part-2 with latest amendment, Valves shall be in graded CI with metal to metal (IS 318 Gr. LTB 2) seating, preferably slanted (and not perpendicular) vis-à-vis horizontal axis; SS AISI 410 stub pins & slant seat design with complete Component & Material of construction following below:- 1. Body/Door/Dome - Cast Iron IS 210 Gr. FG 260 2. Hinge pin (single door)/stub pin (multidoor type) - SS AISI 410 3. Seat & Face rings -Gun metal : IS 318 Gr. LTB 2 4. Rivets - Soft annealed brass 5. Fasteners - Carbon Steel 6. Flange Drilling - IS 1538 Table 4 7. PN - 1.0 8. By - pass arrangement - Optional 9. Painting/Coating Inside & Outside epoxy liquid coated : DFT minimum 250 micron, shade RAL 5005/5015 (Blue) 10. Hydro-test Seat : 10/16 Kg/cm2; Body : 15/24 Kg/cm2MAKE -India Valve Pvt. Ltd. (IVC)/ Kirloskar Brothers Limited (KIRLOSKAR) 600 mm dia Kirloskar MAKE |
| 14 | 300 mm dia Kirloskar MAKE |
| 15 | P/F Sluice Valve Shall generally conform to IS 14846 with latest amendment, with length over flanges as per PD of IS 14846 corrensponding to BS EN-558/ ISO 5752 Basic Series 3 in CI Construciton having metal seating (IS 318 Gr. LTB 2). with complete Component & Material of construction following below:-1.Body/Door/Dome -Cast Iron IS 210 Gr. FG 260 2. Spindle- Non rising ; Stainless Steel AISI 410 3. Body Seat/Door Face - Gun Metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted; no screws allowed) 4. Rivets - Soft annealed brass 5. Spindle Nut - Gun Metal : IS 318 Gr. LTB 2 6. Stem Seal - Greased Hemp 7. Fasteners - Carbon Steel 8. Flange Drilling - IS 1538 Table 4 & 69. PN 1.010. Accessories (400 mm and above) - Ball thrust bearing to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug 11. Painting/Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005/5015 (BLUE)12. Hydro-test - (Open Ended Only) Seat: 10/16 Kg/cm²; Body 15/24 Kg/cm²13. Upto 600 mm dia Manual Operated & above 600 mm Gear Box Make-Indian Valve Pvt. Ltd. (IVC)/Kirloskar Brothers Limited (KIRLOSKAR) 800 MM with gear box. |
| 16 | 600 mm dia |
| 17 | 450 mm dia |
| 18 | 300 mm dia |
| 19 | S/F of M.S. specials such as Tee, Bend, Collars, Tapers, Gap Pieces, including flage ends as required, painting, cutting, welding as per site requirement of MS pipe thickness etc. complete in all respect as per direction of E/I. |
| 20 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:120 sq. mm. |
| 21 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:120sq. mm. |
| 22 | Hire Charge of Generator (Including cost Service of operating staff, supply of lubricating oil and diesel also) D.G. Set/Generator 63 KVA |
| 23 | Hiring of Gas Cutting Set with Oxygen and LPG Running Time @ 6 Hrs. |
| 24 | Hiring of Welding Set Running Time @ 6 Hrs. |
| 25 | S/L of 3 core standered aluminium conductor XLPE (cross linked polythene) insulated PVC bedded, Galvanised flat steel strip aroured cable confirming to IS : 7098 (Part-II with latest amendmrnts) 11 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand alround and protected with well burnt bricks on sides and on top put across. The armourning of cable shall be properly connected with earth conductor by clamps etc. 120 sqmm 3 core |
| 26 | Supply and fixing of M.S. box of size 600mm x 480mm x200mm deep in sunk for housing BDB/TPN fabricated from 16 gauge M.S. Sheet and 13mm x 2.5mm flat iron etc. painted outside with red oxide primer and inside with synthetic enamel paint complete in all respect.(Cubical Box). |
| 27 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). |
| 28 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 29 | S&F of 800 Amp. four pole change over switch on 50mm x50mm x 6mm angle iron frame, including the cost of labour,T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 800 Amp. four pole on 50mm x 50mm x 6mm angle iron frame. |
| 30 | S/Fof 630 KVA Copper Wound Transfromer. |
| 31 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. |
| 32 | Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. |
| 33 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface complete with 14 SWG copper earth continuity wire, piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 34 | Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface,complete with 14 SWG copper earth continuity wire , GP Box and piano type switch and socket etc. complete in all respect but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 35 | Wiring point for H.P.M.V./ Sodium Vapour lamp with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface complete with 14 SWG copper earth continuity wire,GP Box , and 15 A piano type switch etc. complete in all respect. but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 36 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. The Contractor has to detectdifferent utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in-Charge. |
| 37 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 10.0 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 38 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand). |
| 39 | Steel work welded in built up sections/ framed work, including hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 40 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 41 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 42 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |