Tender For Operation And Maintenance Of Sewerage Treatment Plant Of 1728 Flats At Cmjay R1 To R4 And R5, South Extension Scheme. 5201, 1 Part - A 2 Operation and Maintenance of STP (24Hr.) CMJAY R1- to R4 & R5, South Extension Scheme including all necessary material (Cow Dung, Gud, Urea Fertilizer, Genral Oiling of Machineray and Man Power) Required for biological treatment. 3 Part - B 4 P & F 1HP Non Clog Pump With Vertical Stand /PMU as required material or components shall be use as per guidelines of OEM of original product with 01 Year Warrenty.Make-Kirloskar,Cromption 5 P&F Blower 1LE7501-1DB23-5AA4 - 3KW 5HP 4P B3 FOOT- 1500 RPM FR: 160M IP55 CL F 415V- 50HZ- VPI IE2 MOTOR material or components shall be use as per guidelines of OEM of original product with 01 Year Warrenty.Make-Kirloskar,Cromption,Siemens 6 P&F 1.0HPSewage Pump Three Phase 50x50 SP2HM material or components shall be use as per guidelines of OEM of original product with 01 Year Warrenty. Make-Kirloskar,Cromption 7 P&F 1HP Kirloskar KDS 1040+ Three PhaseMonoblock Pump Set, Di2011000210 material or components shall be use as per guidelines of OEM of original product with 01 Year Warrenty. Make-Kirloskar,Cromption 8 Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire E class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 9 Filter Pump 3HP 10 Recycle Pump 1HP 11 Air Blower 5HP 12 Swerage Pump 1HP 13 Repairing of 1HP Non Clay Pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 14 SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 415 V, 50 Hz; O/L & S/C 15 Up to 100 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 16 125 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 17 Desludging of septage from soak wells/pits/ septic tanks and transporting and emptying at inlet of FSTP including operation and maintenance of the equipment with all accessories complete in all respect over the O&M period as per specification and direction of Engineer. 18 O&M for 4000 liter truck 19 O&M for 1000 liter truck 20 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. 21 35.0 Sq. mm* 4 core 22 Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. 23 4.0 Sq.mm 3 core flat / Round 24 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Single pole MCB (With B/C curve tripping Characteristics) , 6 A to 32 A rating