Tender For Civil Work - Special Repairs To Toilet Doors And Windows In Ipd Building In Government Hospital At Gummidipoondi In Thiruvallur District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Dec 2024
0 days left
EMD
3600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
gummidipoondi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Civil Work - Special Repairs To Toilet Doors And Windows In Ipd Building In Government Hospital At Gummidipoondi In Thiruvallur District.
BOQ
| Sl. No. | Item Description |
| 1 | Renewing the damaged ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 2 | Renewing the damaged Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 200mm x 6mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). |
| 3 | Colour designed digital print ceramic tiles size of 300mm x 200mm x 6mm |
| 4 | Renewing and refixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 5 | Renewing and refixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). |
| 6 | Renewing and refixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 7 | Replastering with Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 8 | Reconstruction of Brick work in cement mortar 1:5 (One cement and five sand) using using best quality II class Ground moulded chamber burnt bricks of size 9\" x 43/8\"x 2 3/4\"in for foundation andbasement and super structure,complying withstandard specification including curingetc complete as directed by the departmental officers. |
| 9 | In Ground Floor |
| 10 | Labour wrought and put up in position Shutters for Glazed windows including labour charges for fixing furniture fittings complying with standard drawings and standard specification. |
| 11 | CRCA pressed steel Box section 18 Gauge or1.25mm thick for Door frames including providing holes and fixing wooden blocks for fixing furniture and fittings With powder coated primer. |
| 12 | Renewing the damaged PVC door with new PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail,Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. |
| 13 | Renewing and refixing in position of Aluminium door of single / double shutter half glazed and half panelled door with frame made out of box section 101.60 x 44.45 x 3.18mm at 2.319 Kg /m door shutter frame made out of 47.1 x 44.45 x 2.50 mm at 1.202 Kg /m for vertical styles, top and middle and bottom section 100.40 x 44.45 x 2.50 mm at 1.974 Kg /m and using Aluminium clips of size 17.15 x 17.27 x 1.50 mm at 0.176 Kg /m full handle section of size 100 x 30 x 1.60mm at 0.988 Kg/m on both sides, with necessay metal screws, rubber beading, PVC felts, Alu.hinges, tower bolts, automatic door closure, lock, 5.50mm thick plain glass of required size and both sides prelaminated MDF board 12mm thick for panel portion including cost of all materials, labour, power consumption required for fabrication, drilling holes in RCC column, floor slabs, masonry walls where ever necessary with power drills to the required extent and make to the original condition after fixing and as directed. All the aluminium sections are to be anodized with matt finish under electrically controlled condition in accordance with IS 1868/1962 of anodic thickness of not less than 15 Microns All aluminium sections and furniture fittingsshould be got approved by the Engineer-in-charge before use on works. |
| 14 | Single Leaf |
| 15 | Renewing the damaged Leach pit reconstruction of new leach pit with necessary excavation, well rings 6 numbers of 90cm dia and RCC covering slab including cost of all materials, labour charges etc., complete as per standard specification. |
| 16 | Renewing and refixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. |
| 17 | Repainting two coats of old plastered wall surface with ready mixed plastic exterior emulsion paint of first class quality and of approved colour without primer including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 18 | Repainting old iron works such as steel doors, windows, ventilators, window bars, balustrades etc. with two coats of best approved first quality and colour in all floors etc., including cost of scrapping charges complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works). |
| 19 | Sub Total Amount for above all items (excluding GST) |
| 20 | GST 18% for above SubTotal Amount |
AI Tender Summary
Tender Timeline
Dec 09, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedDec 12, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 12, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓