| 1 | M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge. |
| 2 | M&L for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge. |
| 3 | M&L for removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge. |
| 4 | M&L forriver washed and screened, dry sand for filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed by Engineer- in- Charge.Note :Measurement shall be taken after punning down. |
| 5 | S&F of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge. |
| 6 | All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 complete all as specified and directed by Engineer- in- Charge. |
| 7 | Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavyduty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge. Cables of the following sizes:-Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately. |
| 8 | 35 Sq mm 3.5 core. |
| 9 | 70 Sq mm 3.5 core. |
| 10 | 95 Sq mm 3.5 core. |
| 11 | 120 Sqmm 3.5 core |
| 12 | 185 Sqmm 3.5 core |
| 13 | 240 Sqmm 3.5 core |
| 14 | 400 Sqmm 3.5 core |
| 15 | 630 Sqmm 3.5 core |
| 16 | S&F of Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65 (weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: (205x255 x112) mm With suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by Engineer- in- Charge. |
| 17 | S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge. |
| 18 | S&F of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge. |
| 19 | S&F of LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. |
| 20 | S&F of LED Flood lights 120 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. |
| 21 | S&F of 90 Watt LED street light fittings made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engineer- in- Charge. Make : Crompton Model No LFLN-120-CDL/60-M or equivalent in Bajaj / Havells / Philips as approved by GE. |
| 22 | M&L for GI Tubes of size 50 mm dia light grade, galvanised, with all fitting, laid in trenchesfor protection of cable in road /drain crossing complete all as specified and directed by Engineer- in- Charge. |
| 23 | Supply &installation of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt.147 kg conforming to IS 2713 (Part-II)including excavation, earth work, PCC foundation, base plate,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer\"s instructions and complete all as specified and directed by Engineer- in- Charge.NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings . The steel pole shall be painted by bituminious paint total lenth inside and up to planting depth outside. |
| 24 | M&L for boring of holes under road, pavement, hard standing by trenchless technologyincluding150 mm dia HDPE pipe suitable for 0.6 mpa working pressure.Note :- The quoted rate shall deemed to be included of taking permission from concerned authority like Army Signal and other utility authority and any damage done during execution of work and the same will be repaired/replaced by the Contractor. |
| 25 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I(1991). |
| 26 | Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick ofmodular polycarbonate thermoplastic enclosures Outdoor type with copper bus bar of capacity 630A, factory made, CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V, 50HZ, AC supply and fixed on raised PCC 1:2:4, type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and earth work including dismantling the unserviceable panel and comprising the followings.INCOMING :-(a) MCCB 4 Pole , 400 Amps 50KA - 01 No(b) Rotary handle- 01 No(c) spreader Link- 01 set( 08 Pcs)(d) RYB Indicating lamps(e) Digital Voltmeter and ammeter of suitable rating(f) set of CT of ratio - 400/05 AmpsOUTGOING :-(a) 160A FP 36 KA MCCB - 08 No.(b) Rotary handle- 08 No.PLATFORM FOR PANEL :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. |
| 27 | Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following:i) Degree of protection of systemii) Temperature Rise Limitiii) Dielectric Propertiesiv) Short Circuit Withstand Strengthv) Effectiveness of protective circuitvi) Clearance and creepage distancevii) Mechanical Operation2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1,DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent.3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall bein accordance with EN 50298-98 for IK 08.4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. TestReports submitted of other material of construction like MS, SS will not be applicable.5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel. |
| 28 | Supply, installing, testing and commissioning of factory made and tested (including CPRI type tested certified timer panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:-INCOMING:-(i)MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA, withthermal & Magnetic release- 01 Nos(ii) Onload changeover 630 Amps -01 No (iii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iv) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTsratio 630/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three(vi) Aluminium bus bar of rating 1000A - set of four OUTGOING :-(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 08 Nos.PLATFORM FOR PANEL :-Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. |
| 29 | (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer .(iv) Energy meter is not included in the present scope of work and shall be shifted from Old LT Panel to New LT Panel.The rate for shifting is also deemed to be included in the quoted rates. |
| 30 | All as in item No19here-in-before but comprising of the following:- INCOMING(i)MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA, withthermal & Magnetic release- 01 Nos(ii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTsratio 630/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three(vi) Aluminium bus bar of rating 1000A - set of four OUTGOING(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 03 Nos.(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 02 Nos.(i) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 02 Nos.PLATFORM FOR PANEL :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer . (iv) Energy meter is not included in the present scope of work and shall be shifted from Old LT Panel to New LT Panel.The rate for shifting is also deemed to be included in the quoted rates. |
| 31 | All as in item No19here-in-before but comprising of the following:- INCOMING(i) ACB 4 pole , 800 Amps,50 Hz,415 Volts, 50 KA, withthermal & Magnetic release- 01 Nos(ii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTsratio 800/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three(vi) Aluminium bus bar of rating 1200A - set of four OUTGOING(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 04 Nos.(ii)MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 04 Nos.(iii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 05 Nos.PLATFORM FOR PANEL :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. (iv) Energy meter is not included in the present scope of work and shall be shifted from Old LT Panel to New LT Panel.The rate for shifting is also deemed to be included in the quoted rates. |
| 32 | All as in item No19here-in-before but comprising of the following:- INCOMING(i) ACB 4 pole , 800 Amps,50 Hz,415 Volts, 50 KA, withthermal & Magnetic release- 01 Nos(ii) Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii) Ammeter digital type with 4 way rotary selector switch-01No (iv) CTsratio 800/5 A ,class 1, ISI marked -01 sets of three (v)Indicating lamp- 01 set of three(vi) Aluminium bus bar of rating 1200A - set of four OUTGOING(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 03 Nos.(ii)MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 02 Nos.(iii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 35 KA with thermal magnetic release- 02 Nos.PLATFORM FOR PANEL :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class \"B\", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer .(iv) Energy meter is not included in the present scope of work and shall be shifted from Old LT Panel to New LT Panel.The rate for shifting is also deemed to be included in the quoted rates. |
| 33 | S&F of Decorative Post top lantern 40 Watt indirect light IP65 protection resistant to impact and corrosion , glare free and better uniformity complete all as specified and directed by Engineer-in-Charge. Make : Crompton MAPLE Cat No LPTO-40-CDL or equivalent in Bajaj / Havells / Philips as approved by GE. |
| 34 | S&F of 10 W twister IP 65 Rated LED Bollard with robust design and efficient light distribution ( garden lights) Make Crompton Twister Cat No LBLTW-10-CDL and pole base cover aestetocally designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directed by Engineer-in-Charge. Note- The cost of excavationand PCC 1:3:6, type C-1 for foundation of size (20x20x20cm) required for post top light pole is deemed to be included in the quoted rate. |
| 35 | S&F of 40 W led post top crown HLYT-08 IP 65 LED post top die cast aluminium with stainless steelpins and toggle. reflector high quality anodized aluminium diffuser cover & power ledand pole base cover aestetocally designed decorative pole length 4mtr, base cover, enhancing the apearance of the pole complete all as specified and directed by Engineer-in-Charge.Note- The cost of excavationand PCC 1:3:6 , type C-1 for foundation of size (20x20x20cm) required for post top light pole is deemed to be included in the quoted rate size. |
| 36 | Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick ofmodular polycarbonate thermoplastic enclosures Indoor type with copper bus bar of capacity 400A, factory made, CPRI approved,e floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with bproper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and elarth work including dismantling the unserviceable panel and comprising the followings.INCOMING(a) MCCB 250 Amps 4 Pole,50 KA- 01 No(b) Rotary handle- 01 No(C) spreader Link- 01 set( 06 Pcs)(d) RYB Indicating lamp(e) Digital laVoltmeter and ammeter of suitable rating(f) set of ibtCT of ratio - 250/05 AmpsOUTGOING(a) Suitable hole in bus bar for out going cable connection including suitable size nut bolt and fastener complete all as specified and directed by Engineer-in-Charge. |
| 37 | Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following:i) Degree of protection of systemii) Temperature Rise Limitiii) Dielectric Propertiesiv) Short Circuit Withstand Strengthv) Effectiveness of protective circuitvi) Clearance and creepage distancevii) Mechanical Operation2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1,DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent.3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall bein accordance with EN 50298-98 for IK 08.4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. TestReports submitted of other material of construction like MS, SS will not be applicable.5.The quoted rate includes the excavation, earth work and required base for fixing the complete panel. |
| 38 | Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge. |