Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-12-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-01-2025 |
| 2 | 20-12-2024 | Date corrigendum | Date | 30-12-2024 |
| 3 | 20-12-2024 | BOQ Corrigendum | BOQ | 30-12-2024 |
| Sl. No. | Item Description |
| 1 | M&L for attending and rectifying day to day complaints of fans by taking down Unsv existing ceiling fans/ exhaust fan/ wall mounted fan of any type/size/makefrom its position at variouslocation such as OTM, Md accommodation and offices under GE(MIS) area, by removing the blades from fan, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing,bushes, burnt winding, shaft, split,condenser etc reassembling after winding and replacing defective parts with new parts including provision of 3 core 1.50 Sqmm) flexible copper cable from ceiling rose to connector, refixing of removed blades and hanging /fixing in its original position properly including necessary testing after hanging fixing complete all as specified and directed. |
| 2 | NOTE FOR ITEM NO 1 :- |
| 3 | (a)The cost of collecting new/old ceiling/exhaust/wall fan any size and any make from AGE E/M-01 store, assembling and fixing at site as directed including servicing, if required, is also deemed to be included in the above rate.And also collection of Unsv fan/Exhaust fan/tablefan/wall fan fromthe existing site and deposited to Fan store and after rectification of same is again collected from fan store and installed at the existing site. |
| 4 | (b)All T & P and Electrician/ labour team as required will be provided by the contractor as directed by Engr-in-charge. Cost of petty stores such as grease, lubricating oil, lock nut, cross pin,check nuts, insulation tape etc are deemed to be included in item No 1 . |
| 5 | (c) Repof the contractor shall be present at complaint cell & responsible for attending the complaints from 8:30 am to 05:00 pm . |
| 6 | (d) Cost of minor stores such as screws, insulation tapes ,nuts, bolts, split pins ofrequired size etc shall be deemed to be included in the above quoted rate. However, major items such as bearings, bushes, Condensers, holding clamps, canopies, fan blades etc shall be measured and paid separately under appropriate items of Schedule \"A\". |
| 7 | M&L for rewinding of stator complete with super enamelled copper wire (gauge/ weight of copper coil shall be same as per dismantled fans), including taping, quick varnishing, drying up, fixingconnection leads and testing of the following size/ sweep of Fans:- |
| 8 | (a)Ceiling Fan of 1400 mm sweep. |
| 9 | (b)Ceiling Fan of 1200 mm sweep. |
| 10 | (c)Exhaust Fan of 400 to 450 mm sweep. |
| 11 | (d) Exhaust Fan t 230 to 380 mm sweep. |
| 12 | Note For item No 2 (a) to (d): Rates are deemed to be inclusive for collection of fan from the Existing site and AGE E/M No.1 yard under contractor\"s own arrangement, removingdefective parts, burnt winding carefully, cleaning & re-assembling the fan after repair i.e. oiling, greasing, washer, lock bolts, connector, cross pin etc, depositing back to AGE E/M No.1 yard and testing complete to the satisfaction of Engineer-in-charge (spare parts will be measured and paid seperately underrelevantitems) |
| 13 | Supply only (in replacement)following parts of fan all as specified and directed by Engr- in-Charge. |
| 14 | (a) Ball bearing of size 6201, 6202, 6203 (Make: NBC /SKF) |
| 15 | (b) Gun metal bush self lubricated, any size, suitable for ceiling and wall fan complete all as specified and directed. |
| 16 | (c) Rubber reel for Ceiling Fan of 1200/1400 mm sweep. |
| 17 | (d) Clamp for hanging ceiling fan made out of MS heavy duty of size 40x 6 mm as per sample including nuts, bolts, washers, etc suitable for 40/50 mm dia GI pipe/angle iron complete all as specified and directed by Engr-in-Charge. |
| 18 | (f) Ceilingfan canopy (Set Of Two) as directed by Engr-in- Charge. |
| 19 | (g) Fan connector for ceiling fan for fixing of capacitor , as directed by Engr-in- Charge. |
| 20 | (h) Fan plate for ceiling fan, as directed by Engr-in- Charge. |
| 21 | (k) Holding clamps for ceiling fan with rubber reel, nuts, bolts, washers, split pins complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F in repairsPVC insulated and FRLSH flexible cable threecore Copper conductor of size23/0.0076 (3 Core x 0.50 Sqmm), ISI marked, complete all as specified and directed by Engr-in-Charge (other than for fans covered in item Sl. No. 01 above in which the rates are deemed to be inclusive.) |
| 23 | Supply onlyblade set (03 Nos) suitable for Ceiling fan 1200mm/1400mm sweep matching with existing blades complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply only exhaust fan blades of existing pattern for 230mm sweep complete as per sample complete all as specified and directed by Engr-in-Charge. |
| 25 | All as per item No 6.00 above but for 300 mm sweep exhaust fan. |
| 26 | All as per item No 6.00 above but for 450 mm sweep exhaust fan. |
| 27 | Supply only exhaust fan louver of existing pattern for 230mm sweep and also provide necessary items for fixing of louvers complete as per sample complete all as specified and directed by Engr-in-Charge. |
| 28 | All as per item No 9.00 above but300 mm sweep exhaust fan. |
| 29 | All as per item No 9.00 above but 450 mm sweep exhaust fan. |
| 30 | Supply only exhaust fan metal frame of existing pattern for 230mm sweep and also providing suitable holes, nuts,bolts , washers etc. for fixing of exhaust fan complete as per sample complete all as specified and directed by Engr-in-Charge. |
| 31 | All as per item No 12.00 above but for 300 mm sweep exhaust fan. |
| 32 | All as per item No 12.00 above but for 450 mm sweep exhaust fan. |
| 33 | Supply only table fan/wall fan blades as per existing pattern size 400 mm sweep complete as per sample complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F in repairs condenser 0.80 MFD, 240 Volts, AC 50 Hz confirming toIS 1709 .Make:- Epcos or equivalent as approved by GE. |
| 35 | All as per item No 16.00 abovebut of 2.5 MFD. |
| 36 | All as per item No 16.00 above but of 4.0 MFD. |
| 37 | S&F in repairsMS down rod \"medium grade\" 15mm dia of length 0.75 m complete with making split holes, cut or threads at both end of pipe as required for hanging of ceiling fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer complete all as specified and directed by Engr-in-Charge. |
| 38 | All as per item No 19.00 above butlength 1.50 m. |
| 39 | All as per item No 19.00 above but of length 3.00 m. |
| 40 | M&L for painting of ceiling/exhaust fan any type and size with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter complete all as specified and directed by Engr-in-Charge. AllT & P and labour team as required will be provided by the contractor and cost deemed to be included in the quoted rate. |
| 41 | S&F in repairs electronic Fan regulator step type complete all as specified and directed. |
| 42 | S&F in repairs Power PCB electronic control circuit card suitable for BLDC ceiling fan of existing make and existing model including taking out old onecomplete all as specified and directed by Engr-in-Charge |
| 43 | Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete accesories and removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces ofwalls, floors etc. complete all as specified and directed. |
| 44 | M&Lfor Point wiring with FRLSH PVC insulated PVC unsheathed electriccable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in but in existingconduit & making good the disturbed surface of wall with1.5 sqmm green FR LSH PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet /Modular Boxes for mounting switches, sockets, fan regulators etc for the following:- |
| 45 | (a) One light/fan/bell point controlled by one switch |
| 46 | (b) One 5amps socket out let point controlled by one switch on same board with other switches. |
| 47 | (c) One 5amps socket out let point on independent board controlled by one switch. |
| 48 | All as per item No 43.00 above but using FR LSHPVC insulated unsheathed 2.5 Sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FR LS PVC insulated cable for 15 amps socket point on independent board controlled by one switch. |
| 49 | M&L for stair case point wiring with FRLSH PVC insulated PVC unsheathed electriccable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in but in existingconduit or in casing caping or in conduit of size not less than 20mm & making good the disturbed surface of wall with1.5 sqmm green FR LSH PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet /Modular Boxes for mounting switches, sockets, fan regulators etc for the following:- |
| 50 | M&L for Point wiring using approved colour coding as as per IS in repairs with FR LSHPVC insulated PVC unsheathed electriccable 1100V grade ISI 694 marked down through single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green FR LS H PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet/Modular Boxesfor mounting switches, sockets, fan regulators etc for the following:- |
| 51 | (a) One light point/fan/ Bell point controlled by one switch |
| 52 | (b) One 5amps socket out let point controlled by one switch on same board with other switches. |
| 53 | (c) One 5amps socket out let point on independent board controlled by one switch. |
| 54 | All as per item No 29.00 above but using FR LSHPVC insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FR LSH PVC insulated cable for 15 amps socket point on independent board controlled by one switch. |
| 55 | M&Lfor Point wiringcomplete using approved colour coding as as per ISin repairs with FR LSH PVC insulated and unsheathed electric cable 1100 volts grade single core having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area for phase & neutral, drawn in and including non metallic rigid PVC casing caping not less than 25mm base size with all fitting and fixing accessories and with 1.5 Sqmm green FR LSHPVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs including galvanised/wooden boxes of suitable size with white laminated bakelite sheet/Modular Boxes for mounting switches,sockets etc complete for the followings. Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian :- |
| 56 | (a) One light/ fan/ bell point controlled by one switch |
| 57 | (b)One 5amps socket out let point controlled by one switch on same board with other switches. |
| 58 | (c) One 5amps socket out let point on independent board controlled by one switch. |
| 59 | All as per item No 31.00 above but using FR LSH insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green FR LSH PVC insulated cable for 15 amps socket point on independent board controlled by one switch. |
| 60 | S&F switchin repairs piano flush button single pole one way 6Amp 240 volt complete all as specified and directed. |
| 61 | S&F switchin repairs piano flush button single pole two way 6Amp 240 volt complete all as specified and directed. |
| 62 | S&Fin repairs socket outlet flush type 5 pin, 6 amps, 230 volts complete all as specified and directed. |
| 63 | S&Fin repairsSwitch socket combinationwith box 2 in 1, 3 pin, 6 and 16 Amp flush type universal with box, 230 voltscomplete all as specified and directed. |
| 64 | All as per item No 36.00 abovebut 6 A |
| 65 | S&Fin repairs switch piano flush button single pole one way 16 Amp 240 volt complete all as specified and directed. |
| 66 | S&Fin repairs socket outlet flush type multipurpose 2 in1, 3 pin 6 and 16 Amp , 230 volts complete all as specified and directed. |
| 67 | S&Fin repairsbell push single pole, 6 amps, 230 Volts, flush type complete all as specified and directed. |
| 68 | S&Fin repairs ceiling rose surface bakelitethree terminalcomplete all as specified and directed. |
| 69 | S&F in repairs lamp holder insulated body with back plate for batten fittingscomplete all as specified and directed. |
| 70 | S&Fin repairs Bell, ding dong type, AC 230 Volts,single polecomplete all as specified and directed. |
| 71 | S&Fin repairs electronic Fan regulator step type complete all as specified and directed. |
| 72 | S&Fin repairs 20W LED batten with inbuilt smart motion sensor, 230 Volt, 50 Each Hz, 4 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with warranty option of 5 years from date of installation with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings complete with following specification. (i) housing-polycarbonate extrusion, diffuser- opal polymer, LED type MID power Light distribition- general Spread, LED efficiency > 130 lumen/Watt, System effieciency-> 100 lumen/Watt, Driver efficiency - more than 85%, power factor-more than 0.95, THD <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec. in absence of motion switches back to default operation, LED life- upto 50,000 Hrs.Surge Protection- not less than 1KV.Model No.-SZSLBMX020 (Make - Shakti) / Make as specified in Appendix \"A\" of Particular Specifications |
| 73 | S&Fin repairs 10W LED batten with inbuilt smart motion sensor, 230 Volt, 50 Each Hz, 2 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with warranty option of 5 years from date of installation with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittingscomplete with following specification. (i) housing-polycarbonate extrusion, diffuser- opal polymer, LED type MID power Light distribition- general Spread, LED efficiency > 130 lumen/Watt, System effieciency-> 100 lumen/Watt, Driver efficiency - more than 85%, power factor-more than 0.95, THD <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec. in absence of motion switches back to default operation, LED life- upto 50,000 Hrs.Surge Protection- not less than 1KV.Model No.-SZSLBMX010 (Make-Shakti) / Make as specified in Appendix \"A\" of Particular Specifications |
| 74 | S&Fin repairs 36 W LED (2 feet x 2 feet)Serene recess with inbuilt smart motion sensor, 230 Volt, 50 Each Hz, 2 feet x 2feet , polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with warranty option of 5 years from date of installation with all accessories for mounting light fittingscomplete with following specification. (i) housing-polycarbonate extrusion, diffuser- opal polymer, LED type MID power Light distribition- general Spread, LED efficiency > 130 lumen/Watt, System effieciency-> 100 lumen/Watt, Driver efficiency - more than 85%, power factor-more than 0.95, THD <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec. in absence of motion switches back to default operation, LED life- upto 50,000 Hrs.Surge Protection- not less than 1KV. Model No.-SZRSRMX036 (Make- Shakti) / Make as specified in Appendix \"A\" of Particular Specifications |
| 75 | S&Fin repairs 1X18/20 W, 6500K V1 LED inverter batten with lithium ion battery charging time 8 hrs to 10 hrs and back up upto 10 hrs high efficiency with warranty option of 5 years from date of installation with and LED Life -Upto 50,000Hrs all accessories duly connection with three core flexible coppercable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHEXASP7IN1W020, Shakti cat Pt No. SZSLBMX018-iBB / Make as specified in Appendix \"A\" of Particular Specifications |
| 76 | S&Fin repairsintegrated LED tube light fitting 1x18/20 Watt, white light LED or warm light LED 6000K as per site requirment complete fitting with all accessories duly connection with three core flexible coppercable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH / Make as specified in Appendix \"A\" of Particular Specifications |
| 77 | S&Fin repairs integrated LED tube light fitting 1x9/10 Watt,white light LED or warm light LED 6500K as per site requirmentcomplete fitting with all accessoriesduly connection with three core flexible coppercable duly fixed on two nos of PVC square box including taking down the existing complete all as specified and directed.Make:- Havells Cat No. LHEXACP7IN1W010 Bajaj Cat Pt No. BCLSB 10 WH/ Make as specified in Appendix \"A\" of Particular Specifications |
| 78 | S&Fin repairs integrated LED tube light fitting 1x5 Watt,white light LED or warm light LED 6500K as per site requirment complete fitting with all accessoriesduly connection with three core flexible coppercable duly fixed on two nos of PVC square box including taking down the existing complete all as specified and directed.Make:- Havells Cat No. LHEXBLP7IN1W005Bajaj Cat Pt No. BCLSB 05NW / Make as specified in Appendix \"A\" of Particular Specifications |
| 79 | S&Fin repairs retrofit LED tube light T-8 type, 1x20 Watt, 6500K in Polycarbonatebody with extruded Al heat sinkfor efficient heat dissipation including taking down the existing complete all as specified and directed. Make:- Havells Cat No.LHLDDCXCML8Q020 , Bajaj Cat Pt No BLRB20CW LED /Make as specified in Appendix \"A\" of Particular Specifications |
| 80 | S&Fin repairs batten for retrofit type LED tube T-8 Typeupto 1x22 Watt, pre-wired for LED tube complete with all accessories duly connection with three core flexible coppercable and duly fixed on and including two Nos PVC square boxes including taking down the existing complete all as specified and directed.Make:-Havells Cat No.LHFXCENNTN1W020 , Bajaj cat Pt No. BLRB-DB118I/ Make as specified in Appendix \"A\" of Particular SpecificationsNote for item Nos. 69 & 70:- Makes of these items should be same and compatible with each other. |
| 81 | S&Fin repairs Wall light fittings suitable for white light or warm light LED bulb 9 wattwith & including LED bulb of 9 watt, including connection with all necessary fixing accessoriescomplete all as specified and directed by Engr-in-Charge. Make :- Havells Cat No. LHFOECE1TZ1B014/ Make as specified in Appendix \"A\" of Particular Specifications |
| 82 | S&Fin repairs LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP65 protection complete with electric connection all as specified and directed by Engr-in-Charge.Make:- Havells Cat No. HEXAFT10LED857SSYMBOPC, Crompton Cat No. LBH-10-CDL, Bajaj Cat No. BIBWP 10W LED/Make as specified in Appendix \"A\" of Particular Specifications |
| 83 | S&Fin repairsLED street light fittings30 Watt, 6500Kcomplete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection fixed on and including sufficient length and appropriate size GI bracket with all accessories duly connection with three core flexible coppercable complete all as specified and directed.Make:-Crompton Cat No. LSTO-25-CDL, Bajaj Cat No. ENXTP30LWHSYPCSD and equivalent in Havells cat No. LHEXAYP7PN6K030. / Make as specified in Appendix \"A\" of Particular Specifications |
| 84 | S&F in repairs LED round light fitting 12W recess mounting type, white light LED or warm light LED 6500K as per site requirment complete with driver duly connection with coppercable etc. complete all as specified and directed.Make Havells Cat No. LHEBLDP7IZ1W012Bajaj Cat Pt No. BGSLO SLEEK 15W WH RD/ Make as specified in Appendix \"A\" of Particular Specifications |
| 85 | S&F in repairs LED round light fitting 12W surface mounting type, white light LED or warm light LED 6500K as per site requirment complete with driver duly connection with coppercable etc. Make, Havells Cat No. LHEAAHP7ILW012 / Make as specified in Appendix \"A\" of Particular Specifications |
| 86 | S&F in repairs LED round light fitting 15W recess mounting type, white light LED or warm light LED 6500K as per site requirment complete with driver duly connection with coppercable etc. Make, Havells Cat No. LHEBLDP7IN1W015Bajaj Cat Pt No. BGSLO SLEEK 15W WH RD,/ Make as specified in Appendix \"A\" of Particular SpecificationsNote :- Ceiling cutout ø 180 mm, height 23 mm ±1 mm for 15 W |
| 87 | S&F in repairs LED round light fitting 18W recess mounting type , white light LED or warm light LED 6000K as per site requirment complete with driver duly connection with coppercable etc. Make,Jaquar LAVRV018XNBajaj Cat Pt No. BGSLO SLEEK 18W WH RD,/ Make as specified in Appendix \"A\" of Particular SpecificationsNote- All Fittings Should be White/ Warm White as per site Requirement. Note :- Ceiling cutout ø 220 mm, height 23 mm ±1 mm for 18 W. |
| 88 | S&F in repairs recess mounting type 1FTX1 FT LED Luminaire18W, 5700K in white finish with opal diffuser with electronic driver duly connection with coppercable including taking down the existing etc. Make, Bajaj Cat Pt No. BZRSQL 18L WH / Make as specified in Appendix \"A\" of Particular Specifications |
| 89 | S&F in repairs LED ceiling light fittings 34/36 watt recess mounting type 2x2 luminaire, white light LED or warm light LED 5700K as per site requirment completewith driver duly connection wire etc including taking down the existing. Make BajajCat Pt No. BZRSQL36LLEDGXWH/ Make as specified in Appendix \"A\" of Particular Specifications |
| 90 | S&F in repairs LED ceiling light fittings 34/36 watt surface mounting type 2x2 luminaire, white light LED or warm light LED 5700K as per site requirment complete with driver duly connection wire etc including taking down the existing. Make Jaguar Cat No. LULT02S036XC, Crompton Cat No. LCTLRN-36-FO-CDL, BajajCat Pt No. BZRSQL 36W GZ1 WH/ Make as specified in Appendix \"A\" of Particular Specifications |
| 91 | S&F in repairs LED ceiling light fittings recessed mounting of06 watt 6500K complete with driver duly connection wire etc including taking down the existing. Make HavellsCat No. LHEEAQPBIB1W006/Make as specified in Appendix \"A\" of Particular Specifications |
| 92 | M&L for Sub main wiring (in replacement) with two runs ofsingle core FR LSH PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etc including one run of FR LS PVC insulated unsheathed6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete. Note :Two runs of 6sqmm single core multistandred copper conductor and one run of 6 sqmmearth conduit conductor and one length of PVC conduit and its accessories shall be measured as oneunit length. |
| 93 | M&L for Sub main wiring (in replacement)with two runs ofsingle core FR LSH PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etcincluding one run of FR LS PVC insulated unsheathed4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete. Note :Two runs of 4sqmm single core multistandred copper conductor and one run of 4 sqmmearth conduit conductor and one length of PVC conduit and its accessories shall be measured as oneunit length. |
| 94 | M&L for Sub main wiring (in replacement)with two runs of single core FR LSHPVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, includingPVC insulated unsheathed FR LSH 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Note :Two runs of 6sqmm single core multistandred copper conductor and one run of 6 sqmmearth conduit conductor and one length of PVC conduit and its accessories shall be measured as oneunit length. |
| 95 | M&L for Sub main wiring (in replacement)with two runs of single core FR LS H PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FR LSH PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Note :Two runs of 6sqmm single core multistandred copper conductor and one run of 4 sqmmearth conduit conductor and one length of PVC conduit and its accessories shall be measured as oneunit length. |
| 96 | M&L for Sub main wiring (in replacement)with Fourruns of single core FR LSHPVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FR LSH PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable (Two runs of 6 Sq mm cable for earth wire) connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Note :Four runs of 6sqmm single core multistandred copper conductor and two run of 4 sqmmearth conduit conductor and one length of PVC conduit and its accessories shall be measured as oneunit length. |
| 97 | S&Fin repairs Modular Switchflush type 6 Amps single pole, one waycomplete including taking down the existing all as specified. |
| 98 | S&Fin repairs Modular Socket outlet, multi purpose, 2/3 Pin combined 6 Amps flush typecomplete including taking down the existing all as specified. |
| 99 | S&Fin repairs ModularBell push flush type,6 Ampscomplete all as specified. |
| 100 | S&Fin repairs Modular Socket outlet, multi purpose, 2/3 pin combined 16 Amps universal socketcomplete including taking down the existing all as specified. |
| 101 | S&Fin repairs ModularSwitch 16 Amps single pole, one waycomplete including taking down the existing all as specified. |
| 102 | S&Fin repairs modular fan regulator step type, 2 module type complete including taking down the existing. |
| 103 | S&Fin repairs white finished single mounting modular plates suitable formodular accessories of following sizes including taking down the existing:(Make: Legrand Mylinc Series, Anchor Roma Plus, Crabtree Athena Series) |
| 104 | (a) suitable for 1/2 modules |
| 105 | (b) suitable for 3 modules |
| 106 | (c) suitable for 4 modules |
| 107 | (c) suitable for 6 modules |
| 108 | (d) suitable for 8 modules |
| 109 | S&Fin repairs sheet metal boxes concealed in wall suitable for housing modular accessories of following sizes including taking down the existing:- Make: Legrand Mylinc Series, Anchor Roma Plus, Crabtree Athena Series. |
| 110 | (a) suitable for 1 or 2 modules 50mm. |
| 111 | (b) suitable for 3 modules 50mm. |
| 112 | (c) suitable for 4 modules 50mm. |
| 113 | (d) suitable for 6 or 8 modules 50mm. |
| 114 | S&Fin repairsflush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08,with metal doubledoor with 200 Amps rated copper busbar with 2 neutralbar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing withprovision of sapce for TP/FP 100-125 amps G FrameMCCB as incomer and SP/TP MCBs as out going 4 way complete all as specified and directed by Engr-in-Charge. |
| 115 | S&Fin repairs flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08,with metal doubledoor with 200 Amps rated copper busbar with 2 neutralbar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing withprovision of sapce for TP/FP 100-125 amps G FrameMCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified and directed by Engr-in-Charge. |
| 116 | S&Fin repairs double door TPN DBs four wayof powder coated DB\"s suitable for MCB\"s fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge. |
| 117 | S&Fin repairs double door SPN DBs eight wayof powder coated DB\"s suitable for MCB\"s fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge. |
| 118 | S&Fin repairs double door SPN DBs four wayof powder coated DB\"s suitable for MCB\"s fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge. |
| 119 | S&Fin repairs MCCB FP 100 Amps 25 KA including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 120 | S&Fin repairs MCCB FP 125 Amps 27 KA including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 121 | S&Fin repairs MCB TPN 50 to 63 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified and directed by Engr-in-Charge. |
| 122 | S&Fin repairs MCB SPN 6 to 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 123 | S&Fin repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity,\"B\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. |
| 124 | S&Fin repairs Single pole and neutral Sheet Metalenclosure with a two pin and earth plug and socket complete with one single pole MCB,20 Ampsincl cutting of wall and fixing of AC box in concealed system and making good of disturbed surfaces complete all specified and as directed. |
| 125 | M&L for Earthing(in replacement) complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MESSSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed. |
| 126 | S&F in repairs Hylembakelite sheet and providing suitable hole on hylem sheet for fixing of swiches ,sockets and modular plates as per site requirementwall suitable for housing modular accessories of following sizes including taking down the existing:- Make: ISI marked |
| 127 | (a) Hylem bakelite sheet of size ( 5 inch x 5 inch) suitable for 1 or 2 modules 50mm |
| 128 | (b) Hylem bakelite sheet of size ( 8 inch x 5 inch) suitable for 3 modules 50mm. |
| 129 | (c) Hylem bakelite sheet of size ( 6 inch x 9 inch)suitable for 4 modules 50mm. |
| 130 | (d)Hylem bakelite sheet of size ( 9 inch x 11 inch)suitable for 8 modules 50mm. |
| 131 | Note for item No 1.00 to 107.00 :- Contarcor will provide minimum 05 Nos of Electrician and 05 Nos of helper alongwith T&P and Ladder etc for attending day to daycomplaints . Contractor\"s electrician and helper should be available at complaint cell between 9:00AM to 5:00 PM and also contractor\"s rep will be responsible for note down the complaints in the complaint resister bookon daily basis and also provide complaint resister bookand also provideall T&P for repair/replacement of Lights /Fan pointwiring at Wall & ceiling at any Height. And also forInstallations of Ceiling fans /wallfans/ exhaust fans at any height.repair/replacentof Lights /fans/ pointwiring /installation ofCeiling fans /wallfans/ exhaust fans at any height. Bidders are requested to quote their rate accordingly, Nothing extra will be paid to the contractor. |