| 1 | Supply part of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION |
| 2 | Prov. Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA |
| 3 | Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 4 | Prov. Muffs with concerete filling |
| 5 | Prov. X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line |
| 6 | Prov. MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA\"s |
| 7 | Prov. X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 8 | Prov. Transformer Bed, Belting & Knee Bracing |
| 9 | Prov. X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 10 | Prov. X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] |
| 11 | Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 12 | Prov. MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
| 13 | Prov. MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 14 | Prov. MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 15 | Prov. MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 16 | Prov. GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 17 | Prov. GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 18 | Prov. D.O Fuse Unit |
| 19 | Prov. Surge Arrester, 9 kV Station Class(Porcelain Type) |
| 20 | Prov. Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 21 | Prov. Stay set complete |
| 22 | Prov. Stay Wire (7/3.15 mm) (10 kg Per Stay Set) |
| 23 | Prov. Pipe Earthing Set |
| 24 | Prov. LT Distribution Panel Box With MCCB(160A, 10KA, 4P, 1No) & SFU(32A, 5No, rewirable) |
| 25 | Prov. Half Clamp (M.S. Flat 50X6 mm) |
| 26 | Prov. Full Clamps (M.S. Flat 50X6 mm) |
| 27 | Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more(with flat and spring washers)] |
| 28 | Prov. Aluminium Thimble |
| 29 | Prov. Copper Thimble |
| 30 | Prov. Danger Plate |
| 31 | Prov. Barbed Wire |
| 32 | Prov. Aluminum Paint. |
| 33 | Prov. 6/1/3.35mmsq |
| 34 | Prov. Transformer structure protection plinth (Civil Work as per HPSR) for 63 KVA S/stn. |
| 35 | Erection of 63 KVA S/Stn. i.e. digging of pit for pole & earthing two No. poles & 3 Nos. for earthdrilling of holes in X-arms, preparation of plateform str. Members C.I., A.L. i.e. X-arms & K.B. set, errection of D/P, concreating of RCC muff errection of plateform, errection of X-arms, D.O., L.A., MCCB, Switch LT box, energy meter, errection of transformer, earthing connection to G.O. switch, Transformer L.A. etc., errection of stay set, jumper, pipe earthing 3 Nos set, L.T. cable, barbed wire and painting complete in all respect. |
| 36 | Supply Parts of 11KV HT Line |
| 37 | Prov. 6/1/3.35mmsq |
| 38 | Prov. Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 39 | Prov. Muffs with concerete filling |
| 40 | Cross Arm (Chennel Iron (100X50X6mm) ,Length:-1270mm i/c tolerance of 100mm either side |
| 41 | Prov. MS Angle Iron (50X50x6 mm), Length: (750 mm) x2 Nos |
| 42 | Pole Top Bracket (MSCI:100X50X6mm-100mm) |
| 43 | Pole Top Bracket (MSCI:100X50X6mm-100mm) |
| 44 | Prov. Pin Insulator with GI Pin |
| 45 | Belt set-MS Angle iron :50X50X6,Length 1800 mm X2 No.) For Dead End Structure |
| 46 | X-Bracing Set-MS Angle Iron 50X50X6,Length (1225 mm X2 No) for Dead End Strcture |
| 47 | X-Arm (Horizental) MS C-Iron:50X50X6,Length (2340 mm X2 No) for Dead End Strcture |
| 48 | Discs Insulator Sets on Dead End Structure (Comprising 1 No Disc) Porcelain,BS 12KV,90KN ) Including Dead Clamp etc.X (3 No conductor ) X (2 No Side ) For Dead End Clamp |
| 49 | Prov.Stay set complete HT i/c Egg + clamp stay wire) |
| 50 | Prov. Almunium Paint |
| 51 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 52 | Prov. G.I Wire |
| 53 | Eye Hook for Earth Wire |
| 54 | Half Clamps |
| 55 | Full Clamps |
| 56 | Prov. Do Fuse |
| 57 | Prov. GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 58 | Danger Plate (250X200X1.6mm)(Prov by HPSEBL) |
| 59 | Prov. Barbed Wire (REC sp F 3/1981) |
| 60 | Prov. HT Erathing Set Complete (REC Constr. Standared J-1) |
| 61 | ERECTION PARTS OF 11KV HT Line |
| 62 | Erection of 9 Mtr. Steel Tubler Polei.e. digging of pit, fixing of insulator, x-arms,K.B. set, Top clump, barbed wire, danger plate, drilling of holes and filling of pit + ramming , painting of pole complete in all respect. |
| 63 | Erection of Stay set HT i.e. digging of pit, fixing of stay road, filling of pit, nozzeling & tightning. |
| 64 | Fixing of jumper |
| 65 | Sagging of conductor i.e. laying, stringing and sagging & binding with insulator (Single wire per KM). |
| 66 | Sagging of GI Wire i.e. laying, stringing and sagging & binding(Single wire per KM). |
| 67 | Supply Parts OfLT Line |
| 68 | Prov. Steel Tubular Pole (8M) |
| 69 | Prov. RCC Muff with Concerete |
| 70 | Prov. Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more(with flat and spring washers)] |
| 71 | Prov. D.I Iron with Shacke Insulator |
| 72 | Prov. LT Stay Set Comp. |
| 73 | Prov. AAAC 7/3/1.15mm |
| 74 | Prov. Earthing Wire (G.I 8 SWG ) |
| 75 | Prov. Al. Paint |
| 76 | Prov. A.L 75X75X6,, (Length 1.5 +0.2Mtr. |
| 77 | ErectionParts OfLT Line |
| 78 | Erection of 8 Mtr. Steel TublerPolei.e. digging of pit, fixing of insulator, x-arms,K.B. set, Top clump, barbed wire, danger plate, drilling of holes and filling of pit + ramming , painting of pole complete in all respect. |
| 79 | Erection of Stay set LT i.e. digging of pit, fixing of stay road, filling of pit, nozzeling & tightning. |
| 80 | Laying stringing and sagging of AAAC/ACSR/50mm (4Wire) of LT Line laying of conductor,dtringing and sagging binding with insulator making jumper on dead poles etc. complete in all respect (Rate to be quoted in KM) |
| 81 | Mannual carriage of LT Line Materials on steel tubular pole for an average lead of 1KM from road head to site of work i.e 200M (Rate to be quoted in KM) |