| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-12-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-01-2025 |
| Sl. No. | Item Description |
| 1 | Supply and fixing in replacementsolar street light fitting 20 watt with high efficiency mono crystalline solar PV Module, Lithium Ferro Phosphate battery with inuilt BMS technology, High efficiency LED, MPPT solar charge controller & Aluminium Extrided bodyincluding medium grade galvanized steel pole of 07 mtr height and 80 mm dia,(Excavation & earth work, returning filling and removing shall be measured and paid separately. The solar light consist of following features:- Solar PV Module - 12 V 20W - Mono-crystallineLuminaire wattage - 15 WBattery (LiFeP04) with BMS - 12.8V 10.5 AhBackup - 24 Hours with dimmingSolar charge controller- MPPTSolar charge controller capacity - 12 V, 3 AEfficiency - >93%LED Make- OSRAMLED viewing angle - 120 digreeColor temperature- 5700 K Luminous Efficacy- >100Lumen/wattLife span - >50000 hoursDriver - In built DC - DC typeBody- Aluminium Extruded BodyDust and water protection- IP 66 StandardsLow voltage indication- Red LEDCharging Indication- Green LEDOther protection - Over charge protection, deep discharge protection, Over currentprotection, Short ckt protection & over voltage protection |
| 2 | Material and labour for dewatering the existing RCCJack well(famous named Nalota spring) without any damage to existing tank and its connected items and cleaning of internal side wall and bottom surface and remove silt / scales, mud and other foreign materials using water and scrubbing with coir / jute / wire brush and washing the all surfaces with fresh water cleaning the surfaces with mixture of bleaching powder and water and finally washing with fresh watercomplete all as specified and as directed. Note:- (i) Cost of cleaning materials and T&P is included in quoted rate of this item. |
| 3 | Material and labour in replacement of newwire mesh cover opening fitted with MS frame of suitable size for existing RCC Jack Well (diameter 3.5RM approx) The size of new wiremesh opening shall be suitable with the top side of existingJack Well. wiremesh with MS frameshall be fixed on topof RCC Jack Well permanently. Providing all necessary items for fixing the same shall be responsibility of the contractor. The cost of each items necessary for fixing is inluded in the quoted rate of this item. |
| 4 | Material and labour in replaement of new MS ladder of 21 feet height of 40mm dia MS pipe and fixeed properly with innersidewall ofRCC jack well. Steps of ladder shall be made of same size of MS pipe and interval distance between two nearest steps shall not be more than 40 CM and thickness of circular MS pipe shall not be less than 5mm. complete all as specified and as directed by Engr-in-Charge. Note:- (i) Cost of All welding work/ jointing work shall be included in quoted rate of this item. (ii) During working period dewatering of sump shall be responsiblilty of the contractor. |
| 5 | Labouronly for removing all old filter media of various sizes from Jack well and stacking outside and packing and filling the newfilter media carefull into the Jack Well (grade wise) under the item No 6 to 8 of sch and complete & testing all directed at site. |
| 6 | Supply only gravels of size 25 mm to 40 mm in 30cm layers in filter beds including screening, cleaning and washing complete all as specified and directed. (Source of gravel:-Lal Kuan, Haldwani). |
| 7 | Supply only gravels of size 16 mm to 25 mm in 30cm layers in filter beds including screening, cleaning and washing complete all as specified and directed. (Source of gravel:-Lal Kuan, Haldwani). |
| 8 | Supply only natural quartz sand of size 1.5 to 2.5mm in filter bed complete all as specified & directed. (source of sand:- Janshi/Babina) |
| 9 | Supplying and fixing erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paintinternally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to flood lights through pole where junction box to be fitted in pole, complete with pole cap and all as specified and directed by Engr-in-Charge and taking down old pole any type. Note : Excavation and Earth Work ,PCC in foundation shall be measuredand paid for separately. |
| 10 | Supply and fix in replacement 36 Watt LED street light fitting made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection and alongwith 10KV SPD complete all as specefied and directed. |
| 11 | Supply and fix in replacement 45 Watt LED street light fitting made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection and alongwith 10KV SPD complete all as specefied and directed. |
| 12 | Supply and fix in replacement 120 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED\"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection,PF > 0.95 voltage range of 140-280V should be provided.Luminarie should have top maintainable driver compartment for easy access to driver during maintenance.The driver used must be a constant current driver with efficiency of > 85% complete all as specefied and directed. |
| 13 | Supply and fixmoduler box made of FRP / inpact resistance plastic & heat resistant materialsincluding size 200 x160 x100 mm withIP 65,MCB proviosn suitable connection for three phase armoured enlclouseweather proof , water proof, dust proof internally embdded gas kit with proviosn of incoming and outgoing cable entry through similarIP protected matric size gland haff turn screw of openeeble lid .screw is made out of polycarbonatematerial alongwith MS /MS powder coted/ galavinsedpol mouned clamp of required size( OD of the pole ) including taking down old unserviceable box any type etc complete all as specified and directed. Make Hensel / Sintex |
| 14 | Material & labour for fixing new street light bracket made out of GI pipe medium grade 40 mm bore circular type/squre type and suitable for provision offour flood lights. Approx dia of circular bracket not less than 60 cm (excuding both side dia of circular bracket) includingclamps (if required), cutting. Welding drilling holes , nut, bolts washer etc and alsoincluding one coat of red oxide primer and two coat of aluminium paintcomplete including taking down existing unserviceable bracket etc complete all as specified and directed. |
| 15 | Supply and fixing 2 core PVC insulated and PVC sheathedflexiable weather proof cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 sq mm confirming to relevent ISincluding taking out old unserviceable cable etc complete all as specified & directed. |
| 16 | Taking down carefully Unserviceable Street liight/Security light/High Mast lightfitting of any capacityfrom pole/Structure and repair/replacement of worn out parts such as SPD/Driver/ toughened glass etc,cleaning of fittings,cover,copper wire,clamps ,nuts and bolts,mounting bracket and re assembling the same after repair,testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light/Security light/High mast light complete all as specefied. Note : Replacement of defective spare parts of fitting (to make functional ) will be measured and paid separately as supply only.However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate. |
| 17 | Supply only in replacement driver for LED energy saving & enviornment area light fittingof 40 watt to 70 watts security light with active power factor correction (APFC) electronic driver.LED driver of suitable watt with existing LED secuity light fittingwith operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge. |
| 18 | Supply only in replacement driver for LED energy saving & enviornment area light fittingof 90 watt to 150 watts security light with active power factor correction (APFC) electronic driver.LED driver of suitable watt with existing LED secuity light fittingwith operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge. |
| 19 | Supply only in replacement SPD suitbale for 40 to 72 watt LED light fitting complete all as specified and directed. |
| 20 | Supply only in replacement SPD suitbale for 90 to 150 watt LED light fitting complete all as specified and directed. |
| 21 | Supply only in replacement of Copper wire single core multistand 1.5 sqmmcomplete all as specified and directed and taking down old wire. |
| 22 | Material and labourMS Chequered plate 7 mm thck in size including cutting fabricated cold or hot welding at site drilling holes nuts - bolt and washers etc including angle iron 65 mm x 65 mm x 6 mm thick for mounting of MS sheet cover dully painted with black bituminous paint over one coat of red oxide primer and as directed. including breaking of existing duct for grouting of angle iron, and making good PCC of the existing duct , at water supply installation all as directed and taking down old chequered plate any type etc complete all as specified and directed. |
| 23 | Material and labour for repair of cable duct of any size in water supply installations broken cable duct shall be made by brick masonry built in cement mortar PCC 1:3:6 of existing size and base surface area of cable duct shall also built in cement mortar PCC 1:3:6 with adequate plastering andplastering 15mm thick on both sides of cable duct and half of the cable duct shall be filled with sand for cable protection and each existing cable shall be laid in proper way complete all as specified and directed. |
| 24 | Material and laour for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25x4mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed and taking down old earthing complete all as specified and directed.Note: (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. |
| 25 | Taking down old U/S changeover switch of any type from existing panel board/wall and S&F for new wall mounted/panel mounted, side handle, off load changeover switch of 400 Amps cap, 4 pole complete all as specified and directed. |
| 26 | Material and labour for cable joiting kit in replacement for 1100 volt (earthed) grade cable for indoor/outdoor end termination complete with jointing material and accessories suitable for 3.5 coreXLPE armoured aluminium conductor cable of size 16 sqmm to 50sqmm complete all as specified and directed. |
| 27 | Material and labour for cable joiting kit in replacement for 1100 volt (earthed) grade cable for indoor/outdoor end termination complete with jointing material and accessories suitable for 3.5 coreXLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and directed. |
| 28 | Material and labour for cable joiting kitin replacement for 1100 volt (earthed) grade cable for indoor/outdoor end termination (as per site reqmt) complete with jointing material and accessories suitable for 3.5 coreXLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm complete all as specified and directed. |
| 29 | Material and labour for filling dry powder ABC MAP type (as per IS:4308:2019) in existing fire extinguisher of 6 Kg capacity and prepared for presrized with dry nitrogen complete all as specified and directed. |
| 30 | Taking down copper/ aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings suchasswitches,ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etcto match with existing surface complete all as specified and directed. |
| 31 | Material and labour for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- |
| 32 | One light, ceiling fan, Exhaust fan or Bell point controlled by one switch. |
| 33 | One5 Amps socket outlet on same board. |
| 34 | One 5 Amps socket outlet on independent board. |
| 35 | Material and labour for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Power socket 15 Amps on independent board. |
| 36 | Supply and fixing Modular switch flush type single pole one way 6 Amps 240 volts, white finish complete all as specified and directed. |
| 37 | Supply and fixing Modular switch flush type single pole one way 16 Amps 240 volts, white finish complete all as specified and directed. |
| 38 | Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specifiedand as directed. |
| 39 | Supply and fixing Modular socket outlet 2 in 1, 6 pin, 6/16 Amps flush type white finish complete all as specifiedand as directed. |
| 40 | Supply and Fixing Modular step typefan regulator single phase 230 volt, 120 watt, 2 module suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. |
| 41 | Supply and fixing for ceiling rose surface PVC body three terminal. 65x50 mm complete all as specified and directed. |
| 42 | Supply and fixing lamp holder PVC body with back plate completeall as specified and directed. |
| 43 | Supply and fixing wall/surface mounted type LED light fitting complete with LED lamp of 1x 20/22 watt (4 ft), extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductorcablesuitable size.etc including taking down existing light fittings complete all as specified and directed. |
| 44 | Supply and fixing LED Light fitting mirror type with high out put diffuser 2 feet ,10watt ,220 v AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc including taking down existing light fittingscomplete all as specified and directed. |
| 45 | Supply and fixing LED Light fitting 1x9/10 watt bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size etc including taking down existing light fittingscomplete all as specified and directed. |
| 46 | Supply and fixexhaust fan made of steel body complete with louvers shutters, 450 mm sweep, RPM 750, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing andincluding writing MES No complete all as specified and directed. Note :- Old exhaust fan shall be deposit to MES store yard. |
| 47 | Supply and fixexhaust fan made of sturdy Engineering plastic complete with louvers shutters , 300 mm sweep,min 39000 cfm @ 1000 RPM, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing andincluding writing MES No complete all as specified and directed, Note :- Old exhaust fan shall be deposit to MES store yard. |
| 48 | Supply & Fixingceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 Nos blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10%, compatible for regulator for speed control and all remaining accessories including safety pin, nut, bolts & washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and directed. Note :- Old Ceiling fan shall be deposit to MES store yard. |
| 49 | Taking down carefully from existing place ceiling fan and removing to MES store yard Scraping, cleaning & painting with two coats of super enamelled paints (as approved by GE) greasing/oiling and refixing at site complete incl electric connection withthree core flexible wire 1.5 Sqmm and writing MES No complete all as specified and directed. |
| 50 | Supply and fixing in replacement MCB DB SPN 4 way double door 230 volt, IP-43, supply complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB\"s of cables/wires complete all as specified and directed. |
| 51 | Supply and fixing in replacement MCB DB SPN 8 way double door 230 volt, IP-43, supply complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB\"s of cables/wires complete all as specified and directed. |
| 52 | Supply and fixing in replacement MCB DB SPN 12 way double door 230 volt, IP-43, supply complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB\"s of cables/wires complete all as specified and directed. |
| 53 | Supply and fixingin replacement factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43-IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus barneutralbar, stranded DIN rail. earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 100/125 Ampsas incomer and 12 SP MCBs (or any combination of SP/TP MCBs) outgoing complete all as specified and directed. |
| 54 | Supply and fixingin replacement factory made epoxy powder coated distribution board TP & N 4 ways (TPN MCCB DB) with metal door (IP-43-IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus barneutralbar, stranded DIN rail. earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 100/125 Ampsas incomer and 12 SP MCBs (or any combination of SP/TP MCBs) outgoing complete all as specified and directed. |
| 55 | Supply & Fixingin replacement MCB SP, 6 to 32 Amps (\"B\" series) having current rating 10 KA completeall as specified and directed. |
| 56 | Supply & fixing in replacement MCB SPN, 32 Amps having breaking capacity 10 KA complete all as specified and directed. |
| 57 | Supply & fixingin replacement MCB 4P, 63 Amps having breaking capacity 10 KA complete all as specified and directed. |
| 58 | Supply & fixingin replacement MCCB 4P, 63 Ampshaving breaking capacity 18 KA complete all as specified and directed. |
| 59 | Supply & fixingin replacement MCCB 4P, 100 Ampshaving breaking capacity 18 KA complete all as specified and directed. |
| 60 | Supply & fixingin replacement MCCB 4P, 125 Ampshaving breaking capacity 18 KA complete all as specified and directed. |
| 61 | Material and labour for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 4 Sqmm 1100 Volts and one run of copper stranded conductor of size 4 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed and taking down old wiring.Note :-1.Two single corecable and one run of earth copper conductor alongwith PVC conduit and PVC fittings will be measured and paid as one unit length. |
| 62 | Material and labour for surface/concealed sub main wiring as required with two single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 6 Sqmm 1100 Volts and one run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 20 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed and taking down old wiring.Note :-1.Two single corecable and one run of earth copper conductor alongwith PVC conduit and PVC fittings will be measured and paid as one unit length. |
| 63 | Material and labour for surface/concealed sub main wiring as required with 4 single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 16 Sqmm 1100 Volts and two run of copper stranded conductor of size 10 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed.Note :-1.4 single corecable and two run of earth copper conductor alongwith PVC conduit and PVC fittings will be measured and paid as one unit length. |
| 64 | Material and labour for surface/concealed sub main wiring as required with 4 single core FRLSH PVC insulated and unsheathed copper stranded conductor of size 10 Sqmm 1100 Volts and two run of copper stranded conductor of size 6 Sqmm for continuous earthing drawn in rigid non metallic PVC conduit pipe ISI marked of size not less than 25 mm dia including to connect their incoming/outgoing electric connections by using required sizes of lugs/thimbles as well as flexible conduit of suitable sizes shall also be used at any open surfaces of conductor complete all as specified and directed and taking down old wiring.Note :-1.Four single corecable and two run of earth copper conductor alongwith PVC conduit and PVC fittings will be measured and paid as one unit length. |
| 65 | Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed conduit wiring, etc. and making good, cutting not exc 10 cm girth all asspecified and directed. |
| 66 | Material and labour for dismantling old water pipe line of 150 mm dia and S&F pipe new Ductileiron SSclass \"K7\" 150 mm bore ISI marked as per IS 8329, including tyton gasket jointsand laid complete all as specified and directed. |
| 67 | Material and labour for construction of new brick masonry valve pit of internal size 75x75x75cm with 230mm thick brick wall built in cement mortar plain cement concrete 1:3:6 and base surface area of valve chamber shall also built in cement mortar PCC 1:3:6 with adequate plastering andplastering 15mm wall sides in cement mortar 1:4 and the pit covered with MS plain sheet 3 mm thick duly fixed to MS angle iron of size 40x40x3mm and duly embedded in plain cement concrete coping 5 cm thick plain cement concrete 1:2:4mm type B1with opening and locking arrangements including painting with two coat of synthetic enamel paint over one coat of primer complete all as directed and taking down old valve chamber any size complete all as specified and directed. |
| 68 | Supplying, fixing and jointing CI/DI doubleorifice kinetic air releasevalve of 100mm dia, ISI marked, suitable for 150mm nominalbore pipe/fittingswith & including joints and jointing materials such as bolt, nuts, washers and rubber gasket etccomplete all as specified & as directed. |
| 69 | Dismantling and taking out old unserviceable foot valve any type and supply and fixing new ball type foot valvefor the following sizes:- Make- Normax/Kartar/Kirloskar/ Bir/ Zolloto |
| 70 | 80 mm bore |
| 71 | 100 mm bore |
| 72 | 125 mm bore |
| 73 | 150 mm bore |
| 74 | 200 mm bore |
| 75 | 250 mm bore |
| 76 | Supply only copper tube (Thimbles) terminal heavy dutyof size 25Sqmm. |
| 77 | Supply only copper tube (Thimbles) terminal heavy dutyof size 35Sqmm. |
| 78 | Supply only copper tube (Thimbles) terminal heavy dutyof size 50 Sqmm |
| 79 | Supply only copper tube (Thimbles) terminal heavy dutyof size 70 Sqmm |
| 80 | Supply only copper tube (Thimbles) terminal heavy dutyof size 95 Sqmm |
| 81 | Supply only aluminium tube (Thimbles) terminal heavy dutyof size 25Sqmm. |
| 82 | Supply only aluminium tube (Thimbles) terminal heavy dutyof size 35Sqmm. |
| 83 | Supply only aluminium tube (Thimbles) terminal heavy dutyof size 50 Sqmm |
| 84 | Supply only aluminium tube (Thimbles) terminal heavy dutyof size 70 Sqmm |
| 85 | Supply only aluminium tube (Thimbles) terminal heavy dutyof size 95 Sqmm |
| 86 | Material and labourfor cement concrete 1:2:4 type B1 using (20 mm graded stone aggregate) as in mass concrete (for pump set foundation/DG set foundation/LT Panel foundation etc) and similar work including necessary framework finished even and smooth completeincluding dismantling of existing PCC complete all as specified and directed.Note :- PCC foundation shall be done as per existing and suitable for available centrifugal pump set. |
| 87 | Material and labour for dismantling of unserviceable sluice valve of 150 mmsize from water pipe line forrepair and openingand greasing complete parts, all parts cleaned by thinner neatly with and including replacement of defective spare parts by news parts including necessary welding machine/ grinding work if required at the time of refitting of spare into sluice valve and refixing on existing water pipe line and testing on full discharge complete all as specified and directed.Note:- (i) Cost ofSpare parts which are required to be replaced during repair shall be deemed to be included in the quoted rates of this item. (ii) During repair of unserviceable sluice valve one functional sluice valve of same size shall be fixed (without any extra cost) at the place of u/s sluice valve at site for smooth functioning of water supply system and contractor will ensure that no water supply breakdown happened at site. |
| 88 | Brass Spindle suitable for 150 sluice valve in replacement of old |
| 89 | Seat with seat ring suitable for 150 sluice valve in replacement of old |
| 90 | Gland packing suitable for 150 sluice valve in replacement of old |
| 91 | Supply and fixin replacement modular boxof size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specefied and directed. |
| 92 | Supply and fixin replacement 15 W LED Post Top with Main Housing made of Pressure Die Cast Aluminium and Spun Aluminium.The LEDs should be inside a separate housing made of die cast Aluminium inside the outer housing to ensure proper heat dissipation. LEDs should be fixed to the bodywith proper thermal conductive paste to ensure quick transfer of heat to Heat sink.The Luminaire should be designed for L70 for a minimum 50 K burning hoursat an ambient of 45 Degrees. The inside housing should be covered with Aluminium cover from top and clear diffuser from the sides. The degree of Ingress Protection should be greater than or equal to IP 65. The Driver should be with Electrolytic Capacitor of min 105 degrees rating and with inbuilt surge protection of 2.5kV and complete all as specefied and directed. |
| 93 | Material and labour for cement concreate 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed. |
| 94 | Supply and LayingGalvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains,laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etcincluding taking down of old unserviceble pipe , complete all as specified and directed. |
| 95 | Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 10 Sqmm 2 core in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape etc including taking down existing cable etc complete all as specified and as directed.Note :-Excavation and earth work, GI pipe,brick and sand cushioning shall be measured and paid separately. |
| 96 | Material and labourfor Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after the cable ,punned down to 18 cms depth after laying and stretching of cable complete all as specified and as directed. Note:- Punned thickness 18cm shall be measured for payment purposes. |
| 97 | Supply and Laying brick covering with width equal to length of brick as mechanicalprotection to cable using sub class `B\" bricks laid flat size 230x115x75 mm complete all as specified and directed. |
| 98 | Material and labour for excavation in trenches in soft or loose soil not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in any type of soil including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed. |
| 99 | Material and labour for returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soilnot exceeding 25 cm in each layer complete all as specified and directed. |
| 100 | Material and labour for removal of excavated material (Soil) to a distance up to 50 Meter from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed. |
| 101 | Material and labour for Cleaning of inner surface ofMS sheet of pressure filter of capacity 250 Cubic meter / hour at RIMC Swimming Pool throughly by using steel scapper/emary paper and remoing all dust, foreign particles, mud and any other useless substances and preparation of shel surface for smooth functioning and applying two coats of black bitiminius paint non-toxic non dissolving to the water suitable for drinking purpose purpose to the internal surfaces of pressure filter shell complete all as specified and directed. |
| 102 | Material and labour for Cleaning and washing the stainer including replacement of unserviceable parts (if required) such as socket tee, pins etc inside the pressure shell of pressure filter of 250cum capacityall as directed by Engr-in-Charge at sitecomplete all as specified and directed. |
| 103 | Material and labour for Cleaning the water channel of existing size made out of MS sheet inside the pressure filter applying two coats of black bituminious paint to the water channel, non toxic non dissolving to the water suitable for drinking purpose including preparation of steel surface complete all as specified and directed. |
| 104 | Labouronly for removing all old filter media of various sizes from pressure filter and stacking outside and packing and filling the samefilter media carefull to the pressure filter bed (grade wise) after cleaning of filter media washed with acid water and free from clay, dust and foreign particles etc including segregation of proper size of fliter media for re-use and complete & testing all directed at site of filter media of all sizes gravels complete all as specified and directed. |
| 105 | Supply, packing & filter with new filter media, carefully to the pressure filter (grade wise) after necessary cleaning, filter media shell be free from clay, dust, foreign particles and any other useless substances etc and complete all as directed at site of 6 mm to 15 mm size gravel complete all as specified and directed. |
| 106 | Description all as per itemNo 96 above but 3 mm to 6 mm sizecomplete all as specified and directed. |
| 107 | Description all as per itemNo 96 above but 0.45 mm to .55 mm sizecomplete all as specified and directed. |
| 108 | NOTE:- Amount of credit ofRs. 59749.00 for retrieved materials is mentioned in Schedule of Credit Page No 32 of tender documents in pdf form which will be deducted offline while acceptance of tender. |