}

Tender For For Releasing Of New Connection And Contraction Of Ht/Lt Line Applied In Jhatpat/Nivesh Mitra Portal Consumer (Running Contract Under Deposit Scheme) In The Area Of Edsd-I/Ii/Iii, Medical/Kithore/Kharkhoda Under Jurisdiction Of Edd-Iv, Meerut. , meerut-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For For Releasing Of New Connection And Contraction Of Ht/Lt Line Applied In Jhatpat/Nivesh Mitra Portal Consumer (Running Contract Under Deposit Scheme) In The Area Of Edsd-I/Ii/Iii, Medical/Kithore/Kharkhoda Under Jurisdiction Of Edd-Iv, Meerut. . Submission Date for this Tender is 11-12-2024. Overhead Line Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46556488
Tender For For Releasing Of New Connection And Contraction Of Ht/Lt Line Applied In Jhatpat/Nivesh Mitra Portal Consumer (Running Contract Under Deposit Scheme) In The Area Of Edsd-I/Ii/Iii, Medical/Kithore/Kharkhoda Under Jurisdiction Of Edd-Iv, Meerut.
Open Tender
NCB
Uttar Pradesh
Meerut
11-12-2024

Tender Details

tender for For releasing of new connection and contraction of HT/LT Line applied in Jhatpat/Nivesh Mitra portal consumer (Running contract under deposit scheme) in the area of EDSD-I/II/III, Medical/Kithore/Kharkhoda under Jurisdiction of EDD-IV, Meerut. Sl. No. Item Description 1 Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :- 2 PCC Pole 8.5 Mtr Long/STP Pole 11 Mtr. Long. 3 Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel, TPMO, Fuse set etc. 4 Metering cubical & double pole CT/PT Unit etc. 5 10 KVA to 100 KVA T/F including complete related material required for transformer. 6 250 KVA T/F including complete related material required for transformer. 7 XLPE Cable of size 3x35/3x70/3x120/3x185 sq.mm 8 Erection of PCC pole 8.5 Mtr long/STP Pole 11 mtr long with grouting after digging a pit of size 1.6 mtr deep in all type of Soil including back filling of the pole with proper ramming after completion of work (as per UPPCL Respo). 9 Fabrication and fixing of all 11 KV HT/LT line accessories (as per UPPCL Respo). 10 Erection of Double pole on PCC pole 8.5 mtr/STP Pole 11 mtr long with grouting after digging a pit of size 1.6 mtr deep in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo). 11 Fabrication and fixing of MS angle and MS channel, fixing all 11 KV accessories, Fuse set 11 KV pin insulators on D/P Pole. (as per UPPCL Respo). 12 Installation ofMetering cubical & double pole CT/PT Unit etc. 13 Mounting of 10 to 100 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F. (as per UPPCL Respo). 14 Mounting of 250 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F. (as per UPPCL Respo). 15 Making a section pole to exist pole after fabrication & fixing of T channel fixing of all 11 KV accessories. (as per UPPCL Respo). 16 Erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. 17 Laying lifting stringing & proper sagging of ACSR weasel conductor for 3 phase, 3 wire 11 KV line including binding & jumpering properly. (as per UPPCL Respo). 18 Laying of LT ABC Cable of various size including fixing of all LT ABC accessories on support (as per UPPCL Respo). 19 Laying of XLPE Cable of size 3x35/3x70/3x120/3x185 sq.mm pit of the size 1.5 in the trench and road crossing in the air (as per UPPCL Respo). 20 Trenchless boring(as per UPPCL Respo). 21 Fixing of Distribution box including fixing the cable from transformar and consumer service cable (as per UPPCL Respo). 22 Earthing of each 11 KV line pole & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire. (as per UPPCL Respo). 23 Guarding of line with G.I. wire having 2 no. horizontal wire & 3 Mtr distance of SWG G.I. wire after fabrication of guard cross arms of & fixing the same in supports. (as per UPPCL Respo). 24 Filling of 11 KV Jointing Kit Indoor/Outdoor of size 3x35/3x70/3x120/3x185 sq.mm (as per UPPCL standard). 25 Chemical earthing of T/F (Neutral and body) with GI Pipe 32mm Dia. (as per UPPCL Respo). 26 Making of New 250 KVA T/F Plinth of size 6x6x3 (feet) (as per UPPCL Respo). 27 Fencing of 250 KVA T/F (as per UPPCL Respo). 28 Providing and fixing G.I Pipe 6 dia (As Per Direction of Supervising Engineer). 29 Providing and fixing of Holding Clamp (As Per Direction of Supervising Engineer). 30 Providing and fixing of LT Clamp (As Per Direction of Supervising Engineer). 31 Providing and fixing of J Hook (As Per Direction of Supervising Engineer). 32 Providing and fixing of Piercing Clamp (As Per Direction of Supervising Engineer). 33 Providing and fixing of Dead and Clamp(As Per Direction of Supervising Engineer). 34 Providing and fixing of MS Nut and Bolts(As Per Direction of Supervising Engineer). 35 Cutting & chopping tree branches near side of line for making the clearance between line and tree.

Key Value

Document Fees
INR 3540 /-
EMD
INR 21180.0 /-
Tender Value
INR 21.18 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail