Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #46541982

Tender For Supply, Installation, Testing And Commissioning Of Centralised Medical Gas Pipeline System At District Hospital Chengannur

Issued by Boards / Undertakings / PSU · chengannur, Kerala
Tender Value
2.23 Crore
Estimated cost
Bid Submission
23 Dec 2024
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chengannur → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply, Installation, Testing And Commissioning Of Centralised Medical Gas Pipeline System At District Hospital Chengannur

BOQ

Work Name : Development of District Hospital at Chengannur, Alappuzha District - MGPS
Sl. No. Item Description
1Oxygen Supply System
2od250758/2022_2023 : Fully Automatic Main Oxygen supply system with manifold : Supply, Installation, testing and commissioning of Fully automatic gas control panel with flow capacity of1500LPM at 5 bar regulating/Supplypresuure. Should have the connectivity of the Cylinder service and liquid oxtgen plant. suitable for Manifold capacity - 2 x 10 cylinder capacity (As per technical specification Standard: ISO 7396 -1 / HTM 02-01)
3od250761/2022_2023 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 10 cylinders with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard ISO 7396/HTM 02-01 Please check technical specifications for complete details.<br>
4od250762/2022_2023 : Supply, Installation, Testing and commissioning of Oxygen Manifolds - 2 banks x 4 cylinders with tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard ISO 7396/HTM 02-01 Please check technical specifications for complete details.<br>
5Nitrous Oxide Supply System
6od250763/2022_2023 : Supply, Installation, Testing and commissioning of fully automatic control panel N2O with Nominal flow rate of 300 LPM suitable for 2x4 cylinder manifold . The installation must fully comply with the standard ISO7396-1 or Equivalent. Please check technical specifications for complete details
7od124139/2024_2025 : Supply, Installation, Testing and commissioning of Emergency Cylinder Manifold 2 bank x 2 cylinderswith emergency N2O high flow regulator with gauges and safety valves and tail pipes, NRV, fixing chain etc. The installation must fully comply with the standard ISO 7396/HTM 02-01. Please check technical specifications for complete details.
8od124140/2024_2025 : Supply, Installation, Testing and commissioning of N2O Manifold - 2 banks x4cylinders with with tail pipes, NRV, fixing chain etc.
9Carbon dioxide Supply System
10od250767/2022_2023 : Supply, Installation, Testing and commissioning of Fully Automatic Main CO2 supply system with manifold : Supply, Installation, testing and commissioning of Fully automatic gas control panel with flow capacity of200LPM .Manifold capacity - 2 x 2 cylinder capacity (As per technicalspecification Standard: ISO 7396 / HTM 02-01)<br>
11od250769/2022_2023 : Supply, Installation, Testing and commissioning of CO2 Manifold - 2 banks x 2 cylinders with with tail pipes, NRV, fixing chain etc.<br>
12Compressed Air Plant
13od250775/2022_2023 : Supply,Installation, testing and commissioning of Medical Air Plant consisting of 3 screw compressor compact super sound absorbing tower design and each compressors should have1000 LPM at 13 bar in free air delivery pattern.Twin vertical air receiver tank Capacity 1500 liters each, 2 Dryer and double filtration unit - 5-stage conditioning systems with filters and adsorption dryer and a pressure reducer station, electrical control panel. (Two set of medical air purification system as per the technical specification and air qualityaccording to european pharmacopea.)Each compressor should have minimum FAD of 1000LPM (35CFM). Third party certification to be produced for medical grade air quality and compressor FAD capacity verification.
14Vacuum Plant
15od250780/2022_2023 : "<br>Supply, fixing, testing and commissioning of Medical grade Central Vacuum System Complete with Three rotary vane type Vacuum Pumps each having 2200 LPMat a pressure of 450mmHg.with motor , Filter, interconnecting pipes, NRV, auto switch gear assy,and common receiver 2 x 2000 liters (water capacity fabricatedconforming to IS 2825 and material of construction should be IS 2062 plate).each vacuum pump should have FAA 2200 LPM at 450mmHg, <br>Dual Bacteria Filters shall have an efficiency at least 99.9999%inaccordance withHTM 02-01 /ISO 7396. The system should supply with the electricalpanel"<br>
16od250782/2022_2023 : Supply installation testing and commissioning of Electrical Control Panel for Air Compressor & Vacuum Pump complete with plant Room wiring<br>
17WAGD SYSTEM
18od250784/2022_2023 : Supply, Installation, Testing and commissioning of WAGD SYSTEM (meeting ISO 7396-2/HTM02-01)<br>Terminal Units
19od250785/2022_2023 : Supply installation testing and commissioning of AGSS Hose Asembly,as per technical specification .
20Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity)
21od250786/2022_2023 : Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity) <br>1 Gases (O2) and 1 Vac (DN 20) with NIST Connection
22od250797/2022_2023 : Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity) <br>2 Gases (O2, Air) and 1 Vac (DN 20) with NIST Connection
23od250799/2022_2023 : Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity) <br>3 Gases (O2, Air4,N2O) and 1 Vac (DN 20) with NIST Connection
24od250800/2022_2023 : Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity) <br>4 Gases (O2, Air4,Air 7, N2O) and 1 Vac (DN 20) with NIST Connection
25od250803/2022_2023 : Supply, installation, testing and commissioning of Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity) <br>5 Gases (O2, Air4, Air 7,N2O, CO2) and 1 Vac with NIST Connection
26Isolation valves
27od250805/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 15 - 15x1<br>
28od250806/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 20 - 22x1
29od250807/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 25 - 28x1,5
30od250808/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 32 - 35x1,5
31od250810/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 42 - 54x1,5
32od250812/2022_2023 : Supply, installation, testing and commissioning of Ball valve with male screw threads and flat tightened solder unions, front ends with slots to incorporate o-ring, oil-free and degreased, for medical gases and vacuum, handle with safety device securing handle in operating position, marked acc. DIN EN 19. Please check technical specifications for complete details. - Imported<br>DN 80 - 76x1,5
33\" Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings\"
34od250813/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Oxygen (O2)
35od250814/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Nitrous Oxide (N2O)
36od250816/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Medical Air 400
37od250817/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Surgical Air 700
38od250818/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Vacuum (Vac)
39od250821/2022_2023 : Gas Outlet Points/ Terminal Unit (BS standard) :Supply,Installation, testing and commissioning ofGas outlet points for following Medical Gas as per specified in Tender schematic drawings <br>Carbon Dioxide (CO2) as perDIN standard
40Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.
41od250828/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>O2
42od251090/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>O2( Matching probe / adaptor shall be provided at one end suitable for Oxygen Gas Outlets and other end for ventillator)
43od252001/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>Vacuum
44od252085/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>MA4
45od252094/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>N2O
46od252095/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>SA7
47od252096/2022_2023 : Supply, installation of Matching Probe/adopter with one end suitable for Hose & other end suitable for terminal units which complies and fully meets with the latest standard.<br>Co2
48Bed head panels
49od250838/2022_2023 : Supply, installation, testing and commissioning of Horizontal Bed Head Panels of 3 feet longwith provision for 3 nos electrical (power & data) & min 3 nos Gas outlets - as per technicalspecificationfor Post operative beds
50od250841/2022_2023 : Supply, installation, testing and commissioning of Horizontal Bed Head Panels of 4 feet longwith provision for 3 nos electrical (power & data) & min 5 nos Gas outlets - as per technicalspecificationfor ICU beds
51od250849/2022_2023 : Supply, installation, testing and commissioning of Continous Bed head panel with provision for fixing Medical gas outlets, power sockets, nurse cal points etc. as per the design requirement.
52Medical Equipments
53od250850/2022_2023 : Supply, installation, testing and commissioning of Oxygen Flow meter with humidifier bottle 0-15 litres..Matching probe / adaptor shall be provided at one end suitable for Oxygen Gas Outlets and other end for flow meter.
54od250851/2022_2023 : Suply installation testing and commissiong of Ward Vacuum Unit which consists of the following :- 1no. Suction Regulator and 1no. 1000ml polysulphone collection jar. Suction Regulator : Suction regulator should be supplied with a safety jar, including and antibacterial filter and an anti overflow safety device. Should have wide membrane continuous suction controller. It Should have vacuum levels : 0-1000mbar/hPa. Should have vacuum gauge fitted with a protective bumper device. Should haveon/off knob allowing for the quick restoration of a readjusted vacuum level with one end suitable for vacuum gas outlets and other end for Vacuum Hose.
55od250904/2022_2023 : Supply installation, testing and commissioning of Theatre Suction Unit.It must consists of the following :- 1no. Suction Regulator and 2nos. 2000ml polysulphone collection jar and both to be mounted on a trolley. Suction Regulator : Suction regulator should be supplied with a safety jar, including and antibacterial filter and an anti overflow safety device. Should have wide membrane continuous suction controller. It Should have vacuum levels : 0-1000mbar/hPa. Should have vacuum gauge fitted with a protective bumper device. Should haveon/off knob allowing for the quick restoration of a readjusted vacuum level. Theatre Suction Unit with 3200 ml jars as per specifications.Matching probe / adaptor shall be provided at one end suitable for Vacuum Gas outlets and other end for Vacuum Hose including trolley.<br>
56od250949/2022_2023 : Supply installation testing and commissioning of Medical gas hose assemblies shall comply with BS EN 739. Hoses shall be color coded throughout their length as specification: High pressure Hose antistatic duly colour coded for Oxygen , Nitrous Oxide, Medical Air and Vacuum as per technical specification .Certificate of Origin must be given.
57Master plant alarm - Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity)
58od250914/2022_2023 : Supply, installation, testing and commissioning ofMaster plant alarm<br>Master plant alarm - Integrated area alarm with Valve Box (Including valves)and gauge (should complyEN ISO 7396 and BMS compatiblity)
59od124159/2024_2025 : Supply, Installation, Testing and Commissioning of Surgeon's Pendant - 1750mm Double Arm along with high pressure flexible hoses and necessary NIST adapters. (Provision for 10 electrical + 4 data + 3 Shelf + Provision for Gas outletswith terminal units)
60od124160/2024_2025 : Supply, Installation, Testing and Commissioning of Anaesthesia Pendant - 1000mm Single Arm along with high pressure flexible hoses and necessary NIST adapters. (Provision for 10 electrical + 4 data + 1 Shelf + 1 IV pole + Provision for Gas outlets with terminal units)
61Copper Piping As per EN13348 standards.
62od250925/2022_2023 : "Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>12mm OD x 1mm thick copper pipe
63od250929/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>15mm OD x 1mm thick copper pipe
64od250931/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>22mm OD x 0.9mm thick copper pipe
65od250934/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>28mm OD x 0.9mm thick copper pipe <br>
66od250935/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>35mm OD x 1.2mm thick copper pipe
67od250936/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>42mm OD x 1.2mm thick copper pipe
68od250937/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>54mm OD x 1.2mm thick copper pipe
69od250938/2022_2023 : Supply,Installation testing and commissiong of Medical Grade LLOYD certified Copper Pipes : Copper pipes manufactured from phosphorous de-oxidised non-arsenical copper to BS EN 1412:1996 grade and having mechanical properties in accordance with BS EN 13348:2008 in either R250 (half hard) or R290 (hard).Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS EN 13348:2008<br>76mm OD x 1.5mm thick copper pipe

AI Tender Summary

OUR REF NO 46541982
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.23 Crore
LAST DATE 23-12-2024
Authority
Authority Name Wapcos Limited
Work Description Supply, Installation, Testing And Commissioning Of Centralised Medical Gas Pipeline System At District Hospital Chengannur
Basic Detail
Tender No WAP/INFRA/KERALA/2024/CMGP/494
Bidding Type Tender
Location
City chengannur
State Kerala
Key Dates
Publish Date 05 Dec 2024
Submission Date 23 Dec 2024
Open Date 24 Dec 2024
Finance
Tender Value 2.23 Crore
Tender Fee 8850
EMD 1 Lakhs
Exemption Not Available
Document List
3059b9e0-be62-4ca6-9100-ecc0a9b52613.html
BOQ - 05120340.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 05, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 23, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 24, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3059b9e0-be62-4ca6-9100-ecc0a9b52613.html

xls

BOQ - 05120340.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail