| 1 | Please note that Quoted rates are exclusive opf GST. GST will be paid separtely as per rules and regulation of GOI. |
| 2 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge.( 3.5 Core x300 Sqmm Armoured AluminiumCable.) |
| 3 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. ( 4 Core x16 Sqmm Armoured CopperCable.) |
| 4 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge.( 4 Core x10 Sqmm Armoured CopperCable.) |
| 5 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. ( 3 Core X 4 Sq mm Armoured Copper Cable.) |
| 6 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.(Upto 35 sq. mm (clamped with 1mm thick saddle) ) |
| 7 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.(Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MSflat clamp) ) |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (Upto 35 sq. mm (clamped with 1mm thick saddle) ) |
| 9 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. ( Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS Metre flat clamp) ) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (3/4 X 300 sq. mm (70mm)) |
| 11 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 16 sq. mm (28mm)) |
| 12 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 4 X 10 sq. mm (28mm)) |
| 13 | Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ( 3 X 4 sq. mm (19mm)) |
| 14 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. ( 150 mm width X 50 mm depth X 1.6 mm thickness) |
| 15 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 16 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke 90 kg and salt 10 kg as required. |
| 17 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)8 way, Double door |
| 19 | Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALSof equipment and machinery all lead lift, loading etc, complete.RCBO63 A,4P, 300 mA |
| 20 | Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALSof equipment and machinery all lead lift, loading etc, complete. RCBO63 A,4P, 100 mA |
| 21 | Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALSof equipment and machinery all lead lift, loading etc, complete. RCBO32 ADP, 30 mA |
| 22 | Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALSof equipment and machinery all lead lift, loading etc, complete.RCBO32 A,DP, 100 mA |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.Single Pole |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.Tripal Pole |
| 25 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 26 | Supplying and fixing TPN sheet steel enclosure on surface/ recess withoutMCB complete with connections, testing and commissioning etc. as required. |
| 27 | Supply & installation of surface mounted DLP U- PVC adaptable trunkingraceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit)PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Racewayswith above specifications |
| 28 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 Pin 15/16 amp socket outlet |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 30 | Supplying and fixing following Modular box with faceplate and cover on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required.6 Module Box with faceplate & cover |
| 31 | Supplying and fixing following Modular box with faceplate and cover on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required.4 Module Box with faceplate & cover |
| 32 | Supplying and installing following size of M. S. cable tray cover , non perforated painted with powder coating suitable for existing perforated painted M.S. cable trays 150x50x1.6 mmwith M.S. suspenders including bolts & nuts, painting suspenders etc as required. (minimum width 150 mmX minimum 50 mm depth X 1.6 mm thickness) |
| 33 | Supply and installation of PVC surface box on wall / ceiling / recess as required. 6 module |
| 34 | 32Amp, single phase : Supply and fixing32A, 3 pin, Single phase, Industrial Socket with safety shutterscontrolled by One no. of 32A, double Pole MCBto be mounted on wall, ( The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) As per IEC 61439-3. suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. Including the cost of all materials, lobour , HOM of equipment and machinerysall lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge.MCB/PLUG/BOX -32A . |
| 35 | 32Amp, three phase :Supply and fixing32A, 5 pin, three phase, Industrial Socket with safety shutterscontrolled by One no. of 32A, three Pole MCBto be mounted on wall, ( As per IEC 61439-3.suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) Including the cost of all materials, lobour , HOM of equipment and machinerysall lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. MCB/PLUG/BOX - 32A |
| 36 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. ( 2 X 4 sq. mm + 1 X 4 sq. mm earth wire ) |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. ( 4 X 4 sq. mm + 2 X 4 sq. mm earth wire ) |
| 38 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia conduit pipe |
| 39 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm dia conduit pipe |
| 40 | Supplying, Transportation ,installation, testing & commissioning loading & unloadingof cubical type LT panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartment form from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates including cleaning & finishing complete withtank process for powder coating having thickness of minimum 80 micrometersin approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 4000Amp,50KA for 1sec. Refer Following Details & Tender specifications data sheet given in volume II, page 293For details of specifications of above said panels.a) Details ofIncomingSection is as below:IncomersMCCB:- 250 A , 4P, 35 KA Moulded Case Circuit Breaker (MCCB)with inbuilt Microprocessor release (LSIG ) over load , short circuit, instantenous, Ground Fault ,Adjustable Ir from 0.4 to 1 In. : 1 No.Control MCB 6A , Class-C as shown on SLD: Indications : LED Indication : RYB forPhase &ON/OFF/TRIP indication lamp for MCCBStatus with required control MCB as shown on SLD - For each incomer.Analouge Volmeter96x96 mm 0-500 Volts With 7 Position Selector Switch: 1 set Digital Ammeter : 96x96 mm, CT operated -/5A, Aux supply 230 V AC, Display for 3 phase line current.Meters: Multifunctional Digital Meter for: KWH , KVAH , KW& MD KVA duly prewired , ready to use, Aux voltage 230 V AC, Optional : connectivity with available wifi for remote monitoring and data loger.Resin Cast Current Transformers :3 Nos. 250 / 5 A ,15 VA CL:1 CT’s for Metering : for incomer b) Details ofOutgoingSection is as below: Type of Feeders : TPN Moulded Case Circuit Breaker (MCCB) InbuiltAdjustable Microprocessor Over current, Short circuit ,Instantinious, and Earth faultrelease (LSIG) , Adjustable Ir from 0.4 to 1 In.Rating ofOutgoings feeders:08Nos 63 Amp 35KA TPN MCCB Indications :LED ON Indication for eachoutgoingsRotary handle with whole assemably as required for each outgoing feeders.Details of Busbars :Main Horizontal Busbar :400A 4P Aluminum 35 K.A. 1-Sec , busbar at current density of0.8 Amp /Sq.mm for each bus section. Amp rating of Vertical TPNBusbar shall be Sum of total connected Feederat current density of0.8 Amp /Sq.mm |
| 41 | Supplying, Transportation ,installation, testing & commissioning loading & unloadingof cubical type Control Cum Time switch Panel suitable for 415V, 3 phase, 4 wire 50 Hz AC supply system. Panel shall be fabricated in compartment form from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates including cleaning & finishing complete withtank process for powder coating having thickness of minimum 80 micrometersin approved shade,The panel shall be as per IS 8623 Specifications & having valid CPRI Test Certification 4000Amp,50KA for 1sec. refre Following Details &.Tender specifications data sheetgiven in volume II, page 293For details of specifications of above said panels.Panel should be suitable for termination of suitable copper armoured cable with earthing termimal. All internal wires and cable should be as per desire current rating of equipments and Approval from Engineer In Charge, IISER Pune for GA and SLD is mendetory a) Details ofSection is as below:Enclosuer contains following component for operation of 2 nos Air conditioning units alternate as required based on timer / manual.Contactor 63 A , 4 pole : 2 nos.Contactor 10 A , 3 pole : 2 nosDigital or mechanical Time switch having2 nos NO+NC contacts with minimum 1 minutes of time interval upto 24 hours ( Day+night hour : 24 hours ), Din mounting : 1 noRCBO Four pole 63 A 300 mA : 1 noMCB TP 6 A : 1 Nos, MCB SP 6 A : 1 noTerminal Strip , DIN rail , hardware , CTs and accessories On door - Multifunction meter for 3 phase voltage and current, Selector Switch Auto / manual and Unit 1 or 2 : 2 nosON OFF Push buttons : 4 nos,Red LED indicator for Power ON. |