| Sl. No. | Item Description |
| 1 | HOSTEL BUILDING |
| 2 | Clearing compound premises of shurbs, plants, jungles etc.by cutting and removing as directed (Specific permission ofEngineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared) |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 4 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(b) Depth of excavation for additional depth beyond1,500 mm. and upto 3,000 mm. but not requiringshoring. |
| 5 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 6 | Filling in foundation or plinth by Fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). |
| 7 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 8 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(A) [Pakur Variety](a) 1:3:6 proportion |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur VarietyIn Ground Floor |
| 10 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur VarietyIn First Floor |
| 11 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur VarietyIn Roof |
| 12 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering without staging in foundation. |
| 13 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.Ground floor |
| 14 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction ofEngineer-In-Charge.In First Floor |
| 15 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.In Roof |
| 16 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL.In Ground Floor |
| 17 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL.In First Floor |
| 18 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL.In Roof |
| 19 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth |
| 20 | Brick work with 1st class bricks in cement mortar (1:6) (b) In Superstructure |
| 21 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 22 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in first floor. |
| 23 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in roof. |
| 24 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local. in ground floor. |
| 25 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local. in first floor. |
| 26 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local.in roof. |
| 27 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In ground floor. |
| 28 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In first floor. |
| 29 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.In roof. |
| 30 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 31 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25%for each addl. floor above 4th floor)(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.In ground floor |
| 32 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25%for each addl. floor above 4th floor)(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.In first floor |
| 33 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn Ground Floor (a) 20 mm thick plaster. |
| 34 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn Ground Floor (b) 15 mm thick plaster. |
| 35 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn Ground Floor (c) 10 mm thick plaster. |
| 36 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn First Floor (a) 20 mm thick plaster. |
| 37 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn First Floor (b) 15 mm thick plaster. |
| 38 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn First Floor (c) 10 mm thick plaster. |
| 39 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn Roof (a) 20 mm thick plaster. |
| 40 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortarIn Roof (b) 15 mm thick plaster. |
| 41 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(b) Two CoatsIn Ground Floor |
| 42 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(b) Two CoatsIn First Floor |
| 43 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(b) Two CoatsIn Roof |
| 44 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.(b) Two CoatsIn Ground Floor |
| 45 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.(b) Two CoatsIn First Floor |
| 46 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.(b) Two CoatsIn Roof |
| 47 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(b) Two CoatsIn Ground Floor |
| 48 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(b) Two CoatsIn First Floor |
| 49 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(b) Two CoatsIn Roof |
| 50 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)ii) Luxury QualityIn Ground Floor |
| 51 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)ii) Luxury QualityIn First Floor |
| 52 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)ii) Luxury QualityIn Roof |
| 53 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In Ground Floor |
| 54 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In First Floor |
| 55 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In Roof |
| 56 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In Ground Floor |
| 57 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In First Floor |
| 58 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :(ii) Two coats (white in shade)In Ground Floor |
| 59 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :(ii) Two coats (white in shade)In First Floor |
| 60 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :(ii) Two coats (white in shade)In Roof |
| 61 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(ii) Two coats (white in shade)In Ground Floor |
| 62 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(ii) Two coats (white in shade)In First Floor |
| 63 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)In Ground Floor(c) 40mm X 6mm, 125mm LengthWindow |
| 64 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)In Ground Floor(c) 40mm X 6mm, 250mm LengthDoor |
| 65 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)In Frist Floor(c) 40mm X 6mm, 125mm LengthWindow |
| 66 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)In Frist Floor(c) 40mm X 6mm, 250mm LengthDoor |
| 67 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)In Roof Floor(c) 40mm X 6mm, 250mm LengthDoor |
| 68 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.In Ground Floor(vi) 100mm. X 50mm. X 1.25mm.Window |
| 69 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.In Ground Floor(vii) 100mm. X 58mm. X 1.90mm.Door |
| 70 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.In Frist Floor(vi) 100mm. X 50mm. X 1.25mm.Window |
| 71 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.In Frist Floor(vii) 100mm. X 58mm. X 1.90mm.Door |
| 72 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.In Roof Floor(vii) 100mm. X 58mm. X 1.90mm.Door |
| 73 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:In Ground Floor(ii) 100 mm grip x 10 mm dia rod.Window |
| 74 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:In Ground Floor(vi) 150 mm grip x 10 mm dia rod.Door |
| 75 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:In Frist Floor(ii) 100 mm grip x 10 mm dia rod.Window |
| 76 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:In Frist Floor(vi) 150 mm grip x 10 mm dia rod.Door |
| 77 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:In Roof Floor(vi) 150 mm grip x 10 mm dia rod.Door |
| 78 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:In Ground Floor(iii) 100mm long x 10mm dia. bolt.Window |
| 79 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:In Ground Floor(iv) 150mm long x 10mm dia. bolt.Door |
| 80 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:In Frist Floor(iii) 100mm long x 10mm dia. bolt.Window |
| 81 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:In Frist Floor(iv) 150mm long x 10mm dia. bolt.Door |
| 82 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:In Roof Floor(iv) 150mm long x 10mm dia. bolt.Door |
| 83 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(b) 250mm long.In Ground FloorDoor |
| 84 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(b) 250mm long.In First FloorDoor |
| 85 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(b) 250mm long.In Roof FloorDoor |
| 86 | M.S. structural works in roof trusses with tubular sectionsconforming to IS: 806-1968 & IS: 1161- 1998 cnnected to oneanother with bracket, gusset cleats as per design, direction ofEngineer-in-charge complete including cutting to requisite size,fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.i) For trusses spanning up to 12.00 mFor roof at second floor |
| 87 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colourcoated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with55 mm & 25 mm self tapping screw, EPDM Washer 16 mmdia & 3 mm th. washer etc. complete with 150 mm end lapand one corrugation minimum side lap. (Payment to be madeon area of finished work). (i) In Roof:- a) With 0.50 mm thick sheet.For roof at second floor |
| 88 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeIn Ground Floor |
| 89 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeIn First Floor |
| 90 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeIn Ground Floor |
| 91 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeIn First Floor |
| 92 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mmthickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessarypigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {Whitecement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi/ Udaypur pink / Udaypur Green / Black Bhaslana(ii) Area of each Slab/tile exceeding 0.3 sq.m. but notexceeding 0.6 sq.m.In Ground Floor |
| 93 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mmthickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessarypigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {Whitecement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi/ Udaypur pink / Udaypur Green / Black Bhaslana(ii) Area of each Slab/tile exceeding 0.3 sq.m. but notexceeding 0.6 sq.m.In First Floor |
| 94 | Supplying fitting and fixing 15 to 18 mm thick Marbleslab/Tile in riser of step or skirting (upto 300 mm ht) over15mm (avg) thick base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/ Sq.m at back side of marble andjointed with white cement slurry @ 2.2 kg/ Sq.m withnecessary pigments including grinding and Granite Polishing.[White cement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi /Udaypur Pink / Udaypur green / Black Bhalsana(ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6sq.m.In Ground Floor |
| 95 | Supplying fitting and fixing 15 to 18 mm thick Marbleslab/Tile in riser of step or skirting (upto 300 mm ht) over15mm (avg) thick base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/ Sq.m at back side of marble andjointed with white cement slurry @ 2.2 kg/ Sq.m withnecessary pigments including grinding and Granite Polishing.[White cement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi /Udaypur Pink / Udaypur green / Black Bhalsana(ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6sq.m.In First Floor |
| 96 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouringpigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete includingthe cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength >1500 NIn Ground Floor |
| 97 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouringpigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete includingthe cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength >1500 NIn First Floor |
| 98 | Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr\"s hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR> 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaningthe tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer\"s specification and direction of Engineer-in-Charge.In Ground Floor: Sizes-300 mm x 300 mm x15 mm |
| 99 | Supplying, fitting and fixing Black Stone slab used in Kitchenslab, alcove, wardrobe etc. laid and jointed with necessaryadhesive Cement mortar (1:2) including grinding or polishingas per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm |
| 100 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.In ground floor. |
| 101 | Supplying fitting approved type ventilator in position after cutting holes in walls setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand of any shade. Payment of mending good damages of wall & plaster and painting to be made separately.(b) R.C.C ventilator of 20 mm. thick(i) Upto 0.10 sq.m. area |
| 102 | Precast pierced concrete jally work as per design and manufacturer\"s specification including moulding etc. with stone chips and necessary reinforcement shuttering complete including fitting, fixing in position in all floors.(a) 50 mm. thick panels |
| 103 | SANITARY AND PLUMBING WORK |
| 104 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.(iv) For 50 usersA) With Pakur variety. (SAIL/TATA/RINL) |
| 105 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcementsupto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork inexcavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. |
| 106 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C.manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia.(SAIL/TATA/RINL) |
| 107 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(iii) Single Socketed 1.8 Meter Length(b) 110 mm |
| 108 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Plain Tee(b) 110 mm |
| 109 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(x) Bend 87.5\"(b) 110 mm |
| 110 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Vent Cowl(b) 110 mm |
| 111 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Pipe Clip(b) 110 mm |
| 112 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(xx) 125/110 P Trap with W.C. Ring75 mm |
| 113 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992Solvent Cement250 ML |
| 114 | Labour for fitting and fixing U.P.V.C. pipes for above ground workincluding cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concretework, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above ground(ii) 110 mm dia |
| 115 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm |
| 116 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm |
| 117 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.i) Polythene Flush Pipe |
| 118 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 119 | Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.(i) 450 mm X 300 mm size |
| 120 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 450 mm long |
| 121 | Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 122 | Supplying, fitting and fixing bib cock or stop cock.a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 123 | Supplying, fitting and fixing bib cock or stop cock.(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 124 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(v) 40 mm dia |
| 125 | Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm.(v) 40 mm dia |
| 126 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(e) 2500 litre capacity |
| 127 | Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. |
| 128 | Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(b) Extra for each additional story |
| 129 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes15 mm dia |
| 130 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes25 mm dia |
| 131 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes40 mm dia |
| 132 | Supplying, fitting and fixing Foot rest for water closet of size 275 mm X 125 mm with(b) Porcelain of approved make. |
| 133 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.(a) With \"P\" trap (with vent) |
| 134 | Supplying, fitting and fixing shower of approved brand and make.(b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand). |
| 135 | Supplying, fitting and fixing shower of approved brand and make.(c) Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 136 | Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass(i) 25 mm dia. and 450 mm long |
| 137 | Supplying, fitting and fixing liquid soap container.(a) Cromium plated. |
| 138 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 139 | Labour for boring through any type of soil for sinking tube well ofrequired dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.(b) For depth upto 250 metre for 150 mm dia. Tube well with topenlargement of 250 mm dia.(upto 50 metre).(i) First 50 metre |
| 140 | Labour for boring through any type of soil for sinking tube well ofrequired dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.(b) For depth upto 250 metre for 150 mm dia. Tube well with topenlargement of 250 mm dia.(upto 50 metre).(i) Next 50 metre |
| 141 | Labour for boring through any type of soil for sinking tube well ofrequired dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.(b) For depth upto 250 metre for 150 mm dia. Tube well with topenlargement of 250 mm dia.(upto 50 metre).(i) Next 50 metre |
| 142 | Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in -Charge(b) 150 mm nominal dia (ii) 7.00 mm wall thickness |
| 143 | (A) Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of of TATA make (heavy quality) as per standard specification, 5 mm thick.(ii) 150 mm dia. (internal) |
| 144 | Supplying brass-strainer with brass socket of approved make. (Heavy type)(iii) 80 mm dia. |
| 145 | Labour for jointing and lowering G.I. or E.R.W. M.S. pipes including mstrainer within the tube well bore vertically with necessary sockets, special fittings and welding as required including cost of all jointing materials, hire charges of tools and plants, cutting pipes to required sizes, making threads, welding pieces together etc. as necessary as per direction of the Engineer-in-charge.(ii) Above 100 mm dia. and upto 200 mm dia. pipe |
| 146 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 147 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. |
| 148 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 149 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. |
| 150 | Providing 200 mm centre guide.i) With Clamp |
| 151 | Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. |
| 152 | Supplying, fitting and fixing special hand pump no. 6 of approved make (for 50 mm or 40 mm dia. tube well). |
| 153 | Supplying, fitting and fixing 65 mm dia. deep well brass cylinder with necessary fittings and accessories. |
| 154 | Supplying, fitting and fixing 15 mm dia. galv. M.S. connecting rod with sockets. |
| 155 | Supply & delivery of clear water vertical wet type submercible pump 2 H.P 100mm dia single phase |
| 156 | DEVELOPMENT OF PLAY FIELD |
| 157 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 158 | (A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 159 | Supplying and stacking of good earth (adequate forhorticulture work) at site including royalty (earth measuredin stack will be reduced by 20% for payment) |
| 160 | Spreading of sludge, dump manure,/farm yardmanure/animel dung manure and good earth in requiredthickness. This includes supply of labour, tools & plantsexcluding materials. |
| 161 | Supplying and fixing grasses tiles of grass MaxicanCarpet/Selection No. 1 Healthy & fresh grasses (size 1\"x1\" orbigger) including watering and maintenance of the lawn for30 days or more till the grass forms a thick lawn free fromwees and fit for mowing including supplying good earth asrequired by Engineer-in-charge. (Rate includes supply oflabour, tools & plants including materials) |
| 162 | ELECTRICAL |
| 163 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the groundlevel as below:By TATA-Medium GI pipe |
| 164 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat25 mm x 6 mm on wall having clearance of 6 mm from wallincluding providing drilled holes on the busbar complete withGI bolts, nuts, washers, spacing insulators etc. as required |
| 165 | Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buriedinside wall/floor as required and making connection toequipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages |
| 166 | Supplying and fixing Sheet steel Main Switches onangle iron frame on wall 415V TPN withfuse on L&N 100/125 Amps |
| 167 | Supplying and fixing(Havells) Changeover switch with SheetSteel enclosure on angle iron frame on wall withnuts bolts etc 415V FP 100A |
| 168 | Supplying and fixing (Havells)Sheet steel Main Switches onflat iron frame on wall 415 V TPN with fuse on L&N |
| 169 | Supplying and fixing(Havells) Sheet steel Main Switches onflat iron frame on wall 240VDP with fuse on L&N30/32 A |
| 170 | Supplying & fixing sheet metal (16 SWG) Iron CladBusbar chambers on angle iron frame on wall, incl.earthing attachment and painting as required – (As per Drawing no. 470 of PWD SpecificationBook – May 1991) 4 bars 415 V, 200 A the Dimension ofAl. bars [85mm long](4*100*15mm)and Dimension of Sheet Metal Box (500*150mm) |
| 171 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthingattachment. |
| 172 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection 40A Havells |
| 173 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection6-32A Havells |
| 174 | Supplying and fixing double door Horizontal TPN MCBDistribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good thedamages to original finish incl. Inter connection withsuitable size of copper wire and neutral link & provisionfor earthing attachment 6 Way |
| 175 | Supplying and fixing (Havells) 63A FP 415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection. |
| 176 | Supplying and fixing (Havells) 10 & 20 A SP 240 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection. |
| 177 | Supplying and Drawing 1.1 KV single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaidpolythene pipe and by the prelaid GI fish wire and makingnecy. connection as required for main switch to TPN MCB DP |
| 178 | Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) size in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc[PWD Schedule page no.E-11(1-e)] for TPN MCB DP to SPN MCB DP & Power Socket |
| 179 | Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) size in 25mm PVC casing-capping (Precision make)/ rigid PVC Pipe incl. necy. PVC clips, fittings etc [PWD Schedule page no.E-11(1-c)]for Roof light & main line |
| 180 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) singlecore stranded \"FR\" PVC insulated & unsheathed copper wire(Brand approved by EIC) in suitable size PVC casing-capping(Precision make) [for horizontal run & ceiling portion] andpartly in 19mm bore, 3mm thick polythene concealed pipe [forvertical run embedded in wall only], with 1x22/0.3 (1.5 sqmm)single core stranded \"FR\" PVC insulated & unsheathedcopper wire for ECC, incl. necy. PVC clips, fittings etc. tolight/fan/call bell points with piano key type switch (Anchormake) fixed on sheet steel fabricated switch board withPerspex/bakelite top cover on wall incl. necy. connections andmaking earthing attachment and mending good damages tobuilding works [PVC casing-capping on Wall and verticalrun & switch box both concealed] Average run 8 mtr [PWD Schedule page no.E-13(8-c)] |
| 181 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socketwith separate 3 nos. 6 A & 1 no. 20A Piano key type switch,indicator & 20A switch type SP MCB (Brand approved byEIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex coverand making necessary connections as required [PWD Schedule page no.E-7(26)] |
| 182 | Fixing only single/twin florescent light fitting complete with allaccessories Directly on wall/ceiling with HW block and suitablesize MS fastener, Ceiling plate, nipples etc. as required [PWD Schedule page no.C-2(14-d)] |
| 183 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. [PWD Schedule page no.C-2(13)] |
| 184 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[ PWD Schedule page no.D-14(29)] |
| 185 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable aspossible and providing necy. length of PVC insulated wire andmaking connection for exhaust of 23 cm (9\") diameter [PWD Schedule page no.C-4(28-a)] |
| 186 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) and 23cm Exhaust fan (9\")[PWD Schedule page no.D-14(32-a)] |
| 187 | Supplying & Fixing 240 V AC/DC superior type Ding-DongCall Bell (Anchor) on HW board incl. S&F HW board [PWD Schedule page no.D-13(20-a)] |
| 188 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [PWD Schedule page no.E-6(18-a)] |
| 189 | Providing CC (6:3:1) muffing 600x600x760 mm in size orequivalent size of cylindrical muffing above ground level aroundthe pole base complete with 3 mm thick neatly finished cementplaster all round after dismantling the unserviceable muffing ifnecessary With 250x250x100mm 16 SWG GI Loop Box [PWD Schedule page no.I-1(12-b)] |
| 190 | Supply &Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [ PWD Schedule page no.D-13(22)] |
| 191 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm)single core stranded \"FR\" PVC insulated & unsheathedcopper wire (Brand approved by EIC) in suitable size PVCcasing-capping (Precision make) with 1x22/0.3 (1.5 sqmm)single core stranded \"FR\" PVC insulated & unsheathedcopper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3pin flush type plug socket with piano key type switch (Anchormake) fixed on sheet steel fabricated CRC MS switch boardwith bakelite/perspex (wall matching color) top cover of 3 mmthick flushed in wall by housing the board after cutting brickwall incl. necy. connection making earthing attachment,painting and mending good damages to building works [PVCcasing-capping and plug box both on surface] On board[PWD Schedule page no.E-12(D-6-a)] |
| 192 | S & F Erection of 80 mm dia G.I. pipe 1.5 mtr. Long as min\" pole on roof of main building along with muffing as per G.S. and necy painting with R.O. |
| 193 | S & F Straight type single arm Bracket 1.5 mtr. Long suitable for 80 mm diaG.I. mini pole as per G.S. and necy painting with R.O. painting |
| 194 | Distribution wiring the above Light fitting by 2 x 3/.036 copper wire as required complete. |
| 195 | S& F SS water proof loop box of 8\"x 6\"x 4\" size in the pole mufting compressing as per direction of EIC |
| 196 | Supplyling of 1200mm sweep ceiling fan 240 V complete with blades, canopy down rod <300 mm> as required including connection |
| 197 | Supplying of 450 mm sweep wall mounted fan 240V complete with blades, canopy down rod upto<300 mm> as required including connection |
| 198 | Supplying of 225 mm Sweep 230 V metalic exhaust /ventilation fan complete in all respect |
| 199 | Supply & fixing master LED Tube 18W (philips make) and connection as per direction of EIC, |
| 200 | Supply & fixing TMC 501 1xT LED batten (philips make) without LED Tube & connection as per direction of EIC. |
| 201 | Supply & Fixing of LED Bulk Head light fittings (philips make) with dic cast aluminium housing & frosted glan on wall/ceiling complete with set |
| 202 | Supply & Fixing of LED street light fittings 90 watt complete with all necessary accessories and connection as per direction of EIC. CRP-404-90-S7-SL-GL-NSG (Crompton make) |
| 203 | Supplying of 9 W LED lamp (philips make) |
| 204 | Add: GST @18% on Total Cost of Civil Work |
| 205 | Add: Labour Walfare Cess @1% on Total Cost of (Civil Work + GST) |