Electrification work of Tragist Hostel (16 units) in district Hathras - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required 3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1x1.5 sqmm.for Inverter 4 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 5 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. . 6 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 7 Supplying and fixing of following ways surface /recess mouting vertical type 415V TPN MCB distribution board of sheet steel dust protected duly powder painted inclusive of 200 Amp tinned copper bus bar, common nutrual link earth bar din bar for mounting MCBs (but without MCBs and incomer) as required 4way (4+12) double door 8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 9 Providing and fixing following rating and breaking capacity and pole MCCB with thermomegnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel making connection etc. as required. 80/100Amp 30KA FPMCCB 10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of Single polein the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 11 5 A to 32 A rating, 240/415 V, 10 kA Double Pole MCB 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 13 2X 1.5sq.mm+1X1.5sq. mm earth wire 14 2X 2.5sq.mm+1X2.5sq. mm earth wire 15 2X 4sq.mm+1X4sq. mm earth wire 16 2X 6sq.mm+1X6sq. mm earth wire 17 2X 16sq. mm + 1X 6 sq. mm earth wire 18 4X 10sq. mm +2 X 6 sq. mm earth wire 19 Earthing with G.I. earth Pipe 4.5 Meter Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 20 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 21 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 22 Supplying, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 23 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required 24 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 25 Supplying and fixing of 4way (4+12),Double door, horizontal type three poleand neutral, sheet steel, MCB distribution board (TPN DB) , 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 26 Providing and fixing M.V.danger notice plate of 200mmx150mm made of mild steel at least 2mm thik and vitreous enameled white on both sides and with incription in single red colour on front side as required 27 S/F of 5A to 32 Amp rating 240/415V ,10ka C Curve, miniature circuite breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing, testing and commissioning etc as required. Triple pole and neutral 28 S/F following rating, double pole 240v RCCB in the existing MCB DB complet with connections,testing, and commissioning etc as required 40A (Sensitivity current 30 mA) 29 Numbring of ceilling fan / exhaust fan/flourocent fittings as required 30 Extra for the luvers/ shutters complete with frame for a exhaust fan of all sizes. 31 S/F of pvc batten/angle holder including connections etc as required 32 S/F of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate 33 S/F modular blanking plate on the existing modular plate & switch box excluding modular plate etc as required 34 S/F of cable end box (loose wire box) suitable for following single pole and neutral , sheetsteel, MCB DB, 240 v , on surface/recess, complete with testing and commissioning etc as required. 8 way double door SPN MCB DB 35 S/F of cable end box (loose wire box) suitable for following triple pole and neutral , sheetsteel, MCB DB, 415 v , on surface/recess, complete with testing and commissioning etc as required. 4 way double door TPN MCB DB 36 S/F of cable end box (loose wire box) suitable for following triple pole and neutral , Verticle MCB DB, 415 v , on surface/recess, complete with testing and commissioning etc as required. 37 Supply and fixing of 18-22W LED Batten fitting with Extruded Aluminum housing, special polycarbonate diffuser for glare free light distribution and suitable mounting for on both surface & saspended, Compelete in all respect.1980-2420 system lumens, >110 Lm/W, PF>0.95, THD<10%, CRI 80, with 3 year warrantee 38 Supply and fixing of LED Street light Fitting with mandatory driver set, having die cast aluminium body with toughend glass UY stabilized PC Cover and lenses suitable for 45 Walt to 50 Watt, Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour 5400-6000 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (NotCircuitory), Phase to Phase protection at 440V, 300V over voltage auto cut and restart feature, 4 KV internal Surge Protection, with 5 years warrantee 39 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. Onsurface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core 40 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelover a cushionof 75 mm. thick sand all around and protected with burnt bricks on sides and on top. Onsurface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge,complete in allrespect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 300 sq. mm 3-1/2 core 41 S/O Exhuast fan Heavy duty (without gst) 300mm sweep 900rpmTS 28CE/(E/M)-47/23-24 42 Supply of fresh airFan 300mm 1-phase 900 rpm,230/250 volts,50Hz. TS 28CE/(E/M)-47/23-24 43 Supply and fixing LED Bulb 12 watt lumen 630 to 735 complete in all respect. 44 Supply and fixing of single light wall bracket with opal glasspaint finishing up to 6 watt LED complete in all respect. 45 Supply and fixingof brass nickleplated compressiongland for PVC insulated& armoured served heathed,undergroundcable including rubber ring etc. complete in all respect. The armouringof the cable shall be properly connected with the earth as per direction of Engineer-Incharge.35 sq. mm 3-1/2 core 46 Supply and fixingof brass nickleplated compressiongland for PVC insulated& armoured served heathed,undergroundcable including rubber ring etc. complete in all respect. The armouringof the cable shall be properly connected with the earth as per direction of Engineer-Incharge.300 sq. mm 3-1/2 core 47 Supply and fixingof plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulatingwith tape and makingconnection etc. complete in all respect as per direction of the EngineerIncharge. 6sqmm 48 Supply and fixingof plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulatingwith tape and makingconnection etc. complete in all respect as per direction of the EngineerIncharge. 10sqmm 49 Supply and fixingof plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulatingwith tape and makingconnection etc. complete in all respect as per direction of the EngineerIncharge. 16sqmm 50 Supply and fixingof plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulatingwith tape and makingconnection etc. complete in all respect as per direction of the EngineerIncharge. 35sqmm 51 Supply and fixingof plainor pin type copper tin plated cable socket ( lug ) to the cable leads, insulatingwith tape and makingconnection etc. complete in all respect as per direction of the EngineerIncharge. 300sqmm 52 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 53 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 54 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand,water as per directions of Engineer-in-Charge. 55 Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. 56 Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. 57 SUB TECHNO COMMERCIAL OFFER FOR SUPPLY OF LT. PANEL BOARD,Supply & Erection of factory fabricated & wired metal clod dust and vermin proof floor mounting. M.S. Channel Base with bottom and top cable entries Electrical Control Panel with TPN MCCBs (Four Pole 36KA) with thermal magnetic release) Complete and instrument chamber etc. complete in all respect. The Instrument Chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameter(KVA,PF, KW etc) in each phase with touch type Selector switches for different readings, instrument fuses, current transformer etc. The Panel Board shall have suitable capacity electrolytic Aluminium Busbar insulated with heat shrink sleeving and mounted on non hygroscopic support such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with sutable cable end boxes, compression glands and indicating lamp an incoming etcThe job includes the grouting of the board as per directions of Engineer-in charge. All outgoings of 100Amp and above shall have an ammeter. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch boordshall be of cat A & B only.PANEL-1, L.T. PANEL BOARD (400A), QTY-1No.QTY1NoINCOMING1-MCCB 400A FP 36KA- 01No. 2-Extended ROTARY HANDLE-01No. 3-Digital Metering (MFM) -01 Set 4-Phase Indicator(R,Y,B) -01 SetOUTGOING1-32A MCCB FP 36КА FOR LIGHT CKT -04 Nos2-Extended Rotary Handle-04 Nos.BUS BAR1-400Amp FP Aluminium Bus Bar-01 Set2-Changeover 100A FP-01 No. OUTGOING FROM CHANGEOVER1-MCCB 80A FP 36 KA for power ckt -04 Nos 2-EXTENDED ROTARY HANDLE-04 Nos. 58 Supply and Fixing of hexazonal/roundGI Fan Box