| 1 | Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 1000 metres, stacking serviceable and unserviceable materials separately as per MORTH specification clause 202. By Mechanical Means : Bituminous courses |
| 2 | Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 50 metres as directed by Engineer.Granular courses |
| 3 | Providing and laying granular sub-base material having P.I.not more than 6, including spreading in layers not exceeding 150 mm compacted thicknessand consolidation by 8-10 tonne power rollerto required camber and grade including cost of water and hire charges of machinery, including T&P with all lead (Compacted thickness to be measured).as per MORTH specification table 400-1, 400-2 : For grading-III with CBR value not less than 20.to attain 100% proctor density. |
| 4 | Providing, laying, spreadingand compactingstone aggregate of specfic as per table 400-6 to Water Bound Macadam specification including spreading in uniform thickness, hand packing roll-ing with vibratory rollerin stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates watering (with water browser) and rolling making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specfication : Clause 404] By Manual MeansGrading I , 63 mm to 45 mm@ 0.91 cum per 10 Sqm for compacted thickness of 75 mm.(Crusher broken) Stone screening type \"B\" |
| 5 | Providing, laying, spreadingand compactingstone aggregate of specfic as per table 400-6 to Water Bound Macadam specification including spreading in uniform thickness, hand packing roll-ing with vibratory rollerin stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates watering (with water browser) and rolling making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specfication : Clause 404] By Manual Means Grading II,53 mm to 22.4 mm, @ 0.91 cum per 10 Sqm for compacted thickness of 75 mm.(Crusher broken) Stone screening type \"B\" |
| 6 | Providing and applying primer coat over prepared surface or granular base with bitumen emulsion as per IS: 8887 & manufacturer’s specifications @ 6 kg /10 sqm with a self propelled of towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MORTH specification CI 502, 501.5.2,112 ( Including cleaning of road surface ) |
| 7 | Providing and applying tack coat on the prepared surface ,withbitumen emulsion as per IS : 8887 & manufacturer’s specifications @ 2 kg /10sqm. With a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MORTH specification CI.503, 501.5.2,112 ( Including cleaning of Road Surface) |
| 8 | Providing and laying bituminous macadam on prepared surface with specified graded crushed aggregate as per table 500 - 6, grading -1for base / binder course including loading of aggregates with F.Eloader and heating and mixing of stone aggregate and bitumenin approvedhot mix plant as per clause 6.5 of manual transporting the mixed material in tipper to paver and laying mixed material with sansor paver finisher to the requiredlevel and grade rolling by power roller & vibratory compactor to achievethe desired density (approved by the department )excluding cost of primer /tack coat [MoRTH Specification : Clause 504,112] 50-100 mm compacted thickness with 3.30% bitumenwith lead of mix 20 Km.Grading II (19 mm nominal size) 3.4 % ofBitumen mixBitumen Grade VG-30 |
| 9 | Providing and laying open graded premix carpet 20mm thick (compacted) on prepared surface in a single course as wearing course aggregates as per Table 500-24, heating bituminous binder @ 14.6 Kg/10 Sqm.(VG-30 grade) and aggregates in Hot Mix Plant, transporting the mixed material with tipper and laying with paver finisher to the required level and grade, rolling with power roller, 8-10 tonne but excluding cost of tack and seal coat with lead for mix of material with all lead .[MORTH Specification : Clause 510,112] In approved Hot Mix Plant as per clause 6.5 of Manual, including loading of aggregates with F.E loader with VG-30 bitumen. |
| 10 | Providing and laying seal coat for sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall, including rolling with a smooth wheeled roller 8 - 10 tonne capacity finished to required level and grades, complete as per MORTH specification clause 511Type B - Premixed in in approved HMPas per clause 6.5 of manual having capacity 50 TPH comprising of aggregate (sand or grit) having size 2.36 mm to 180 micron @ 0.06 Cum per 10 Sqm and bitumen binder (VG-30 grade) @ 6.8 Kg / 10 sqm and laying by hydrostatic paver finisher with sensor control, including mixing, transportation, laying, rolling etc. complete - including carriage for 20 Km. lead. |
| 11 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 12 | Providing and laying ofpaver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP63:2004 |
| 13 | Add extra over rates of item No. 12 if colored paver blocks are used |
| 14 | Raising precast circular manhole cover and frame by taking out existing precast frame and cover, providing and fixing precast SFRC circular spacer of height 100/125/150mm, re-fixing existing manhole cover frame and cover with cement sand mortar (1:3), including making good the damage, complete as directed by Engineer. |
| 15 | Supplying & fixing 560mm dia opening SFRC manhole frame & cover as per IS : 12592-2002 in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer. HD-20 |
| 16 | Labour charges for making connection of sewer line through man hole. |
| 17 | Making connection of G.I. distribution branch with G.I. main including all fitting.Upto 25mm dia |
| 18 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.110 mm dia |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).15 mm nominal size |
| 20 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. size 450 x 450mm depth upto0.5 M Cement cover with frame |