Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #46449304

Tender For Necessary Civil Works Related To Converting Of Normal Class Room - Room No. 31- To Smart Class Room Cum Seminar Room Of Home Science Department In Viharilal College Campus At 20B, Judges Court Road , Kolkata - 27 Under University Of Calcut

Issued by Boards / Undertakings / PSU · Kolkata, West Bengal
Tender Value
8.88 Lakhs
Estimated cost
Bid Submission
16 Dec 2024
0 days left
EMD
17700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Necessary Civil Works Related To Converting Of Normal Class Room - Room No. 31- To Smart Class Room Cum Seminar Room Of Home Science Department In Viharilal College Campus At 20B, Judges Court Road , Kolkata - 27 Under University Of Calcutta.- 1 Stripping off worn out plaster and raking out joints of walls, celing etc. upto any height and in any floor including removing rubish and staking any where within the compound as directed. Area : 2 Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4water : 6 cement) as per manufacturer specifications. 3 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) /with 6:1 cement morter / 20 mm thick. 4 Rendering the surface of walls and ceiling with white cement based water proof wall putty of approved make and brand.. (thickness not less than 1.5 mm.) 5 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (2:1) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).area : 12.8+6.6)2x3.5+12.8x6.6 =220.28 6 Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of EIC./ two coats/ solventbased interior grade Acrylic primer. 7 Labour charges for chipping of theartificial stone floor before taking up the flooring works. 8 Supplying and laying true to line and level double charges vitrified tilesof approved brand conforming to IS 15622: 2006 ( Group B 1a) testedas per IS 13630:2006 ( relevant parts) ( Non modular sizes for tiles with water absorption (av.) < 0.08%) i in floor, skirting etc.using polymerised adhesive of 6 mm thick layer applied directly over finished artificial stone floor / mosaic etc. without any backing course ans joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2 mm as directed and removal of wax coating at top surface of tiles with warm waterand polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete as per direction of Engineer in charge.Size not less than 600 mm x600 mm x905 m thick) in third floor . 9 Hydraulic door closer of approved quality as per I.S.I.Standard fitted and fixed complete./ medium ( Godrej) 10 Supplying, fitting and fixing of false ceilingframe work with powder coatedexposed G.I grid suspension system ( E grid U-1520 or equivalentload carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c consisting of main runner 3600 mm long crosss tee 1200 mm / 600 mm long and wall angle. The wall angle shall be fixed on PVC dash fasteners on the perimetre of the wall by steel screws with distance 300 c/c . the main runners to be placed @ 1200 mm. The cross Tee 1200 will be inserted in the pre cut slots of main runner at a regular interval of 600 mm to form a modular grid of 1200 mm x 600 mm. Additional cross tee of 600 will be placed perpendicular to the cross tee 1200 mm long to finally form a grid of 600 mm x 600 mm. Grid of module size 600 mm x 600 mm shall be supported by 6 mm dia. G.I wire formpulins / soffit all complete as per drawing & direction of Engineer in charge. 11 Supplying, fitting and fixing OW Acoustic Board (Mineral Fibre) Acoustic Ceiling Tiles) of approved patern and size 595x595 mm with NRC valve>0.65 should be placed in the grid mould to form a false ceiling all complet as per drawing & direction of Engineer in cmagre./ false ceiling with 15 mm thick OW Acoustic Board/ 12 Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete ( excluding the cost of bolts, paints but including the cost of nails, screws Etc. / Sal: Siliguri 13 Supplying, fitting and fixing of imported quality fabric with H.D. foam and 4 mm thick ply as well panelling including cost of all materials and labour etc. 14 Labour for wood work in sawing timber to sizes as requiredfor making post, post plates, rafters, batten, truss members, purlins etc. 15 Supplying wooden moulding slanting beat of size 37 mm x 18mm(finished) of approved design tofinish the joint line and level fitted and fixed with adhesive and head less pin s complete asper direction of Engineer-in- chare. / teak wood beat 16 Supplying,fitting and fixing of boiling water proof ply conforming to IS 710:1977bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design and approval of EIC ( excluding cost of supporting frame work andteak wood batten/ lipping) / a.6 mm ply. 17 Supplying fitting and fixing decorative lamination confprming to IS: 2046:1995 as pe approved make brand finish and thickness with fitting, fixing the same on partickle / MDF/ Ply boards with recommended/ approved adhesive with proper clipping the sides for better attachment as per direction of EIC. the rates includes the cost of labour, adhesive and all incidental charges.thereof. / thickness of laminate 1.50 18 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; 6mm thick colour/ tinted/ smoke glass. 19 Anodised alminium butt hings approved quality manufactured from extruded section conforming to IS 205/66 fitted and fixed with cadmiumplated screws./ 125x63x4.0mm/ 20 Anodised alminium D-type handle ofapproved quality manufactured from extruded section conforming to IS 230/72 fitted and fixed complete../ 150mmgripx12mm dia rod. 21 Brass hasp bolt of approved quality fitted and fixed completewith 16 mmdia. Rod with centre bolt and round fitting. / 300 mm long 22 Anodised alminium tower bolt of approved quality manufacturer from extruded section conforming to IS 204/74 fittedand fixed with cadmiumplated screws./ 225mm longx 12 mm dia. Bolt. 23 Add: GST 18 %

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Dec-2024 Terms and Condition Corrigendum Other 16-Dec-2024

BOQ

Name of Work: NECESSARY CIVIL WORKS RELATED TO CONVERTING OF NORMAL CLASS ROOM( Room No.31) TOSMART CLASS ROOMCUM SEMINAR ROOMOF HOME SCIENCE DEPARTMENT IN VIHARILAL COLLEGE CAMPUS AT 20B, JUDGES COURT ROAD , KOLKATA - 27 UNDER UNIVERSITY OF CALCUTTA.
Sl. No. Item Description
1Stripping off worn out plaster and raking out joints of walls, celing etc. upto any height and in any floor including removing rubish and staking any where within the compound as directed. Area :
2Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4water : 6 cement) as per manufacturer specifications.
3Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) /with 6:1 cement morter / 20 mm thick.
4Rendering the surface of walls and ceiling with white cement based water proof wall putty of approved make and brand.. (thickness not less than 1.5 mm.)
5Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (2:1) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).area : 12.8+6.6)2x3.5+12.8x6.6 =220.28
6Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of EIC./ two coats/ solventbased interior grade Acrylic primer.
7Labour charges for chipping of theartificial stone floor before taking up the flooring works.
8Supplying and laying true to line and level double charges vitrified tilesof approved brand conforming to IS 15622: 2006 ( Group B 1a) testedas per IS 13630:2006 ( relevant parts) ( Non modular sizes for tiles with water absorption (av.) < 0.08%) i in floor, skirting etc.using polymerised adhesive of 6 mm thick layer applied directly over finished artificial stone floor / mosaic etc. without any backing course ans joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2 mm as directed and removal of wax coating at top surface of tiles with warm waterand polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete as per direction of Engineer in charge.Size not less than 600 mm x600 mm x905 m thick) in third floor .
9Hydraulic door closer of approved quality as per I.S.I.Standard fitted and fixed complete./ medium ( Godrej)
10Supplying, fitting and fixing of false ceilingframe work with powder coatedexposed G.I grid suspension system ( E grid U-1520 or equivalentload carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c consisting of main runner 3600 mm long crosss tee 1200 mm / 600 mm long and wall angle. The wall angle shall be fixed on PVC dash fasteners on the perimetre of the wall by steel screws with distance 300 c/c . the main runners to be placed @ 1200 mm. The cross Tee 1200 will \be inserted in the pre cut slots of main runner at a regular interval of 600 mm to form a modular grid of 1200 mm x 600 mm. Additional cross tee of 600 will be placed perpendicular to the cross tee 1200 mm long to finally form a grid of 600 mm x 600 mm. Grid of module size 600 mm x 600 mm shall be supported by 6 mm dia. G.I wire formpulins / soffit all complete as per drawing & direction of Engineer in charge.
11Supplying, fitting and fixing OW Acoustic Board (Mineral Fibre) Acoustic Ceiling Tiles) of approved patern and size 595x595 mm with NRC valve>0.65 should be placed in the grid mould to form a false ceiling all complet as per drawing & direction of Engineer in cmagre./ false ceiling with 15 mm thick OW Acoustic Board/
12Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete ( excluding the cost of bolts, paints but including the cost of nails, screws Etc. / Sal: Siliguri
13Supplying, fitting and fixing of imported quality fabric with H.D. foam and 4 mm thick ply as well panelling including cost of all materials and labour etc.
14Labour for wood work in sawing timber to sizes as requiredfor making post, post plates, rafters, batten, truss members, purlins etc.
15Supplying wooden moulding slanting beat of size 37 mm x 18mm(finished) of approved design tofinish the joint line and level fitted and fixed with adhesive and head less pin s complete asper direction of Engineer-in- chare. / teak wood beat
16Supplying,fitting and fixing of boiling water proof ply conforming to IS 710:1977bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design and approval of EIC ( excluding cost of supporting frame work andteak wood batten/ lipping) / a.6 mm ply.
17Supplying fitting and fixing decorative lamination confprming to IS: 2046:1995 as pe approved make brand finish and thickness with fitting, fixing the same on partickle / MDF/ Ply boards with recommended/ approved adhesive with proper clipping the sides for better attachment as per direction of EIC. the rates includes the cost of labour, adhesive and all incidental charges.thereof. / thickness of laminate 1.50
18Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; 6mm thick colour/ tinted/ smoke glass.
19Anodised alminium butt hings approved quality manufactured from extruded section conforming to IS 205/66 fitted and fixed with cadmiumplated screws./ 125x63x4.0mm/
20Anodised alminium D-type handle ofapproved quality manufactured from extruded section conforming to IS 230/72 fitted and fixed complete../ 150mmgripx12mm dia rod.
21Brass hasp bolt of approved quality fitted and fixed completewith 16 mmdia. Rod with centre bolt and round fitting. / 300 mm long
22Anodised alminium tower bolt of approved quality manufacturer from extruded section conforming to IS 204/74 fittedand fixed with cadmiumplated screws./ 225mm longx 12 mm dia. Bolt.
23Add: GST 18 %

AI Tender Summary

OUR REF NO 46449304
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 8.88 Lakhs
LAST DATE 16-12-2024
Authority
Authority Name University Of Calcutta
Work Description Necessary Civil Works Related To Converting Of Normal Class Room - Room No. 31- To Smart Class Room Cum Seminar Room Of Home Science Department In Viharilal College Campus At 20B, Judges Court Road , Kolkata - 27 Under University Of Calcutta.- 1 Stripping off worn out plaster and raking out joints of walls, celing etc. upto any height and in any floor including removing rubish and staking any where within the compound as directed. Area : 2 Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4water : 6 cement) as per manufacturer specifications. 3 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) /with 6:1 cement morter / 20 mm thick. 4 Rendering the surface of walls and ceiling with white cement based water proof wall putty of approved make and brand.. (thickness not less than 1.5 mm.) 5 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (2:1) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge).area : 12.8+6.6)2x3.5+12.8x6.6 =220.28 6 Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper / acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of EIC./ two coats/ solventbased interior grade Acrylic primer. 7 Labour charges for chipping of theartificial stone floor before taking up the flooring works. 8 Supplying and laying true to line and level double charges vitrified tilesof approved brand conforming to IS 15622: 2006 ( Group B 1a) testedas per IS 13630:2006 ( relevant parts) ( Non modular sizes for tiles with water absorption (av.) < 0.08%) i in floor, skirting etc.using polymerised adhesive of 6 mm thick layer applied directly over finished artificial stone floor / mosaic etc. without any backing course ans joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2 mm as directed and removal of wax coating at top surface of tiles with warm waterand polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete as per direction of Engineer in charge.Size not less than 600 mm x600 mm x905 m thick) in third floor . 9 Hydraulic door closer of approved quality as per I.S.I.Standard fitted and fixed complete./ medium ( Godrej) 10 Supplying, fitting and fixing of false ceilingframe work with powder coatedexposed G.I grid suspension system ( E grid U-1520 or equivalentload carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c consisting of main runner 3600 mm long crosss tee 1200 mm / 600 mm long and wall angle. The wall angle shall be fixed on PVC dash fasteners on the perimetre of the wall by steel screws with distance 300 c/c . the main runners to be placed @ 1200 mm. The cross Tee 1200 will be inserted in the pre cut slots of main runner at a regular interval of 600 mm to form a modular grid of 1200 mm x 600 mm. Additional cross tee of 600 will be placed perpendicular to the cross tee 1200 mm long to finally form a grid of 600 mm x 600 mm. Grid of module size 600 mm x 600 mm shall be supported by 6 mm dia. G.I wire formpulins / soffit all complete as per drawing & direction of Engineer in charge. 11 Supplying, fitting and fixing OW Acoustic Board (Mineral Fibre) Acoustic Ceiling Tiles) of approved patern and size 595x595 mm with NRC valve>0.65 should be placed in the grid mould to form a false ceiling all complet as per drawing & direction of Engineer in cmagre./ false ceiling with 15 mm thick OW Acoustic Board/ 12 Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete ( excluding the cost of bolts, paints but including the cost of nails, screws Etc. / Sal: Siliguri 13 Supplying, fitting and fixing of imported quality fabric with H.D. foam and 4 mm thick ply as well panelling including cost of all materials and labour etc. 14 Labour for wood work in sawing timber to sizes as requiredfor making post, post plates, rafters, batten, truss members, purlins etc. 15 Supplying wooden moulding slanting beat of size 37 mm x 18mm(finished) of approved design tofinish the joint line and level fitted and fixed with adhesive and head less pin s complete asper direction of Engineer-in- chare. / teak wood beat 16 Supplying,fitting and fixing of boiling water proof ply conforming to IS 710:1977bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design and approval of EIC ( excluding cost of supporting frame work andteak wood batten/ lipping) / a.6 mm ply. 17 Supplying fitting and fixing decorative lamination confprming to IS: 2046:1995 as pe approved make brand finish and thickness with fitting, fixing the same on partickle / MDF/ Ply boards with recommended/ approved adhesive with proper clipping the sides for better attachment as per direction of EIC. the rates includes the cost of labour, adhesive and all incidental charges.thereof. / thickness of laminate 1.50 18 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; 6mm thick colour/ tinted/ smoke glass. 19 Anodised alminium butt hings approved quality manufactured from extruded section conforming to IS 205/66 fitted and fixed with cadmiumplated screws./ 125x63x4.0mm/ 20 Anodised alminium D-type handle ofapproved quality manufactured from extruded section conforming to IS 230/72 fitted and fixed complete../ 150mmgripx12mm dia rod. 21 Brass hasp bolt of approved quality fitted and fixed completewith 16 mmdia. Rod with centre bolt and round fitting. / 300 mm long 22 Anodised alminium tower bolt of approved quality manufacturer from extruded section conforming to IS 204/74 fittedand fixed with cadmiumplated screws./ 225mm longx 12 mm dia. Bolt. 23 Add: GST 18 %
Basic Detail
Tender No E-tender/Eng/CT-326/24-25
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 03 Dec 2024
Submission Date 16 Dec 2024
Open Date 18 Dec 2024
Finance
Tender Value 8.88 Lakhs
Tender Fee Ref. Documents
EMD 17700
Exemption Not Available
Document List
53aeabdb-3a99-4cb8-bee6-5a244046c86d.html
BOQ_1718395.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 03, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 16, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 16, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 18, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

53aeabdb-3a99-4cb8-bee6-5a244046c86d.html

xls

BOQ_1718395.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders