Tender For Beatification Work Of Shahid Smark At Raebareli - Supply, Installation, Testing And Commissioning Of Led Post- Top Luminaire To Install On The 4 M Decorative Poll, Luminaire Housing Made Up Of Alluminum Pressure Die Costing With Integrated Pol
Tender Overview
Project Description
Tender For Beatification Work Of Shahid Smark At Raebareli - Supply, installation, testing and commissioning of LED post- top luminaire to install on the 4 M decorative poll, luminaire housing made up of alluminum pressure die costing with integrated pole top with embossed brand name/logo of manufacturer. The fixture should have a minimum system efficiancy of 110/LM/W and Maximum system wattage of 45 watt, i.e, total system lumen should not be less than 5000 LM. The Fixture shall have a CRI of min 70 and designed for a system life of 50000 hours @ L-70B50 Lumen maintinance, ingress protection of IP 66 (lamp and gear compartment) without using any kinde of silicone or glue and machanical empact resistance rating of ik-10. The driver should be BIS approved fully potted and in capsulated with 440 VP 2P protection of 8 hours, high cut of @325V (+-15V), auto restart fealure with inbuilt surg protection of 4kv minimum mounting dia should be 60mm. (Product type-45w led post-top fixture 3000k) 2 S/L of 2.5 sqm 3 core aluminum aurmaid cable. 3 S/L of20/25mm PVC pipe 4 Foundation and installation charges for pole fixing. 5 Supply of led based integaral flood light available with 4 different CCT orange/red/green/cool white clourhousing made up of alluminum pressure die cost housing and embossed brand name/logo of manufacturer. The fixture should have a minimum system efficiancy of 100/LM/W and Minimum system lumen outpurt of of 5000 LM. (+-10%) with max. system wattange of 50 watt.The Fixture shall have a CRI of min 80 Ingress protection of min IP65 and designed for a system life of 50000 hours @ L-70B50 Lumen maintinance, ingress protection of IP 665 (lamp and gear compartment)and machanical empact resistance rating of ik-10. The fixture driver should be widevoltage range protection of 140-300 V and surge protection of min. 4KV internal. Luminaire should be BIS approval & comply with the parameters as per IEC 60598. Dimension of luminaire-L-210mm W. 175mm. H.50MM should not me more than this due to site condition 6 Instalation charges including wiring & labour charges. 7 Electical Pand with Timer 8 2.5sq MM 3 core copper Flexiable cable 9 PVC pipe 20/25 mm 10 IP Protected Boxes 11 MS Brakets
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of LED post- top luminaire to install on the 4 M decorative poll, luminaire housing made up of alluminum pressure die costing with integrated pole top with embossed brand name/logo of manufacturer. The fixture should have a minimum system efficiancy of 110/LM/W and Maximum system wattage of 45 watt, i.e, total system lumen should not be less than 5000 LM. The Fixture shall have a CRI of min 70 and designed for a system life of 50000 hours @ L-70B50 Lumen maintinance, ingress protection of IP 66 (lamp and gear compartment) without using any kinde of silicone or glue and machanical empact resistance rating of ik-10. The driver should be BIS approved fully potted and in capsulated with 440 VP 2P protection of 8 hours, high cut of @325V (+-15V), auto restart fealure with inbuilt surg protection of 4kv minimum mounting dia should be 60mm. (Product type-45w led post-top fixture 3000k) |
| 2 | S/L of 2.5 sqm 3 core aluminum aurmaid cable. |
| 3 | S/L of20/25mm PVC pipe |
| 4 | Foundation and installation charges for pole fixing. |
| 5 | Supply of led based integaral flood light available with 4 different CCT orange/red/green/cool white clourhousing made up of alluminum pressure die cost housing and embossed brand name/logo of manufacturer. The fixture should have a minimum system efficiancy of 100/LM/W and Minimum system lumen outpurt of of 5000 LM. (+-10%) with max. system wattange of 50 watt.The Fixture shall have a CRI of min 80 Ingress protection of min IP65 and designed for a system life of 50000 hours @ L-70B50 Lumen maintinance, ingress protection of IP 66\5 (lamp and gear compartment)and machanical empact resistance rating of ik-10. The fixture driver should be widevoltage range protection of 140-300 V and surge protection of min. 4KV internal. Luminaire should be BIS approval & comply with the parameters as per IEC 60598. Dimension of luminaire-L-210mm W. 175mm. H.50MM should not me more than this due to site condition |
| 6 | Instalation charges including wiring & labour charges. |
| 7 | Electical Pand with Timer |
| 8 | 2.5sq MM 3 core copper Flexiable cable |
| 9 | PVC pipe 20/25 mm |
| 10 | IP Protected Boxes |
| 11 | MS Brakets |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender