| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc andmaking good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 2 | M & L for point wiringcomplete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990,PVC insulated andunsheathed , FRLS cabledrawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmmcopper conductor cable (multistranded)PVC insulated and unsheathed FRLS cableas earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVCboardsfor mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch . NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2.wiring shall be done as per complaints receivedfrom user only on reqired basis it is not necessary to do whole wiring of any whole bldg. 3. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 3 | All as per serial item No. 2here in before but for one 6 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as per serial item No. 2 here in before but for one 6 Amp 5 pin socket outlet point on independent board. |
| 5 | All as per serial item No. 2here in before butfor one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 6 | All as per serial item No. 2herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase,Neutral and earth forone 16 Amp, 6 pin socket on independent board. |
| 7 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, all as specified & as directed. |
| 8 | S&F switch socket combination, flush type, 5 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin/2pin 6 Amp plug top white/ivory finish all as specified & asdirected. |
| 9 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (6 pin ) 6/16 Amps, 230V, AC. all as specified & asdirected. |
| 10 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings all as specified & asdirected. |
| 11 | S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & asdirected. |
| 12 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish all as specified & as directed. |
| 13 | S&F fan regulator, step type, electronic on existing phenolic laminated sheet, 5 step, sockettype, 230 volts, 450 watts, suitable for ceiling fan 1200/1400mm sweep all as specified & asdirected. |
| 14 | S&Fbell,AC, 230 volts, single phase complete all as specified and as directed. |
| 15 | S & F square profile LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 20 Watt with LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS COMPY VIZON Cat No LHEXARP7SN1W020or equivalent model of makes specified in PS. |
| 16 | S & Fsquare profile LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 10 Watt with LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS E-LITE LED PRIDE PLUS NEO Cat No LHEXACP5IN1W010or equivalent model of makes specified in PS. |
| 17 | S&F in repairs, 210 mm x 210 mm size, flat panel square fixture, slim,compact, aluminium die cast lit panel, recess mounting1 x 18 watt, 230 voltwith opal diffuser and sepatate electronic driver, LED light source 6500K with uniform light output, with all accessories including tconnections from ceiling rose to light fittings complete all as specified & as directed.Make :- Havells Cat Part No OCTANE LED PANEL SQUARE Item Code LHEBAEP71Z1W018 or equivalent model of makes specified in PS. |
| 18 | S&F in repairs, 110 mm x 110 mm size, flat panel square fixture, slim,compact, aluminium die cast lit panel, recess mounting1 x 6 watt, 230 voltwith opal diffuser and sepatate electronic driver, LED light source 6500K with uniform light output, with all accessories including tconnections from ceiling rose to light fittings complete all as specified & as directed.Make :- Havells Cat Part No OCTANE LED PANEL SQUARE Item Code LHEBAEP71Z1W006 or equivalent model of makes specified in PS. |
| 19 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTE: 1. Proper colour coding shalladopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)2. Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 20 | M & L for sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed.NOTE: 1. Proper colour coding shalladopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)2. Three runs of 2.5 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 21 | S&F in repairs, sheet metal enclosureswith plug socket, single pole and neutral with two pin and earth plug and Top with one MCB of 20 Amps (SP)complete all as specified and as directed. |
| 22 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,\"c\" series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. |
| 23 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,\"c\" series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. |
| 24 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copperbus bar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 25 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 4 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 26 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), Tripple pole and neutral, 415 volts, 4 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 200 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 27 | S&F in repairsISOLATOR TPN, AC 415 V, 63 amps, 10 KA capacity ,\"C\" series, making connection with suitabl size of copper lugs etccomplete all as specified and as directed. |
| 28 | S&F in repairs, security/street light fitting of building with single piece new generation energy savng and environmental friendly, long life, LED 35 W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07including one bracket made of light gradeGI Pipe 25 mm dia, fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connect to nearest electric supply by two core 1.5 sqmm aluminium cable all as specified and as directed. |
| 29 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GIEarth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade,including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)coverreinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. |
| 30 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor of size6 sqmm, two core complete all as specified and as directed. |
| 31 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor of size4 sqmm, two core complete all as specified and as directed. |
| 32 | Supply and fix in replacement 15 watt post top lantern new generation, energy saving, environmental friendly, long life aesthertically designed with symmetrical lightdistribution, spun aluminium landscape luminaire with high power LEDs as light source and IP-65 protection complete all as specified and as directed.Make : Havells CORALPT15W757PSYMTOPC, or equivalent model of makes specified in PS. |
| 33 | S & F gate light made up of high grade unbreakable polycarbonate material suitable for retrofit1x7 W LED Lamp (B22 base) - Moon 150 complete all as specified and as directed.Make:Havells MOON (OPAL) Cat no LHFXBON1TN5Q008or equivalent model of makes specified in PS. |
| 34 | S & F gate light made up of high grade unbreakable polycarbonate material suitable for retrofit 1x20 W LED Lamp (B22 base) - Moon (PRISMAT IC) complete all as specified and as directed.Make:Havells MOON (OPAL) Cat noLHFXBON1TN5Q014 or equivalent model of makes specifiedin PS. |
| 35 | Taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size and greasing ball bearing with specified quality grease ,replacing broken and damaged canopy sets,rubber reel,connector block,capacitors,fan blades etc and re-assembling theceiling fanas a one unit , complete all as specified. Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as supply only under respective items of BoQ. (b) T&P required for repair/ maintenance such as Spaners, manpower etc, shall be included in the quoted rate of this item. |
| 36 | Taking down, strip opening, cleaning all parts and packing of Exhaust fans of any make and size and greasing ball bearing with specified quality grease replacing broken and damaged parts and re-assembling theExhaust fansas a one unit, complete all as specified.Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as supply only under respective items of BoQ. (b) T&P required for repair/ maintenance such as Spaners, manpower etc, shall be included in the quoted rate of this item. |
| 37 | Taking down, strip opening, cleaning all parts and packing of Table/cabin/Air circulating fan/ wall mounting fan of any make and size and greasing ball bearing with specified quality grease, replacing broken and damaged parts and re-assembling the Table/cabin/Air circulating fan/wall mounting fan as a one unit and fixing Table/cabin/Air circulating fan/ wall mounting fanin position and re-commissioning the same including making electric connection complete all as specified and directed. Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as supply only under respective items of BoQ. (b) T&P required for repair/ maintenance such as Spaners, manpower etc, shall be included in the quoted rate of this item. |
| 38 | Taking down from site or collecting from E/M yard,unserviceable ceiling fan 1200 mm sweep any make with blades,transporting to local workshop,opening,cutting out complete copper winding,cleaning with kerosene oil/diesel/terpentine oil and dried out,rewinding with new super enamelled copper wire of suitable size and guage and number of turns as recommended by the respective manufactures,varnishing and heating the winding including providing paperinsulation (cuff/strip) replacing unserviceablepaper insulation replacing unserviceable/missing spare parts, repacement of suitable ball bearing, 2.5 mfd capacitors,painting with super enamelled heat resistance synthetic white paint and writing the MES number with black paint etc and fixing the stator in rotor properly aligned and reasembling ensuring right DOR ,Speedy and noiceless running and depositing in E/M Yard and hanging at site in position complete all as specified and directed by Engr-in-Charge. |
| 39 | All as per srl item No 38 here-in-before but ceiling fan any make upto1400mmSweep. |
| 40 | All as per srl item No 38 here-in-before but exhaust fan any make uptosweep 300mmSweep. |
| 41 | All as per srl item No 38 here-in-before but exhaust fan any make having sweepmore than 300mm and not more than 450mm complete all as specified. |
| 42 | All as per srl item No 38 here-in-before but Table/Air circulating/ cabin/ wall mounting fan any make any sweep. |
| 43 | Supply only of canopy (top and bottom) of ceiling fans any make / size with canopy of matching colour. |
| 44 | Supply only of rubber reel with nut, bolts, split pins etc of ceiling fan with rubber reel heavy duty for hanging fan. |
| 45 | Supply onlydown rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed by Engineer in charge.. |
| 46 | Supply only ofdown rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.6 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed by Engineer in charge.. |
| 47 | Supply only ofdown rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 1.5 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed by Engineer in charge.. |
| 48 | Supply only of connector block of ceiling fan of suitable size of approved quality. |
| 49 | Supply only ofcapacitor of ceiling fans with capacitor having capacity 2.5mfd, 240 Volts. |
| 50 | Supply only of blade of ceiling fan of any make with aluminium blade duly painted of sweep 1200mm including provision of screws etc fixing purpose complete all as specified and directed by Engineer -in-charge. |
| 51 | Supply only ofblade of ceiling fan of any make with aluminium blade duly painted of sweep 1400mm including provision of screws etc fixing purpose complete all as specified and directed by Engineer -in-charge. |
| 52 | Supply only ofReplacement of cable/wire for connection of fan with flexible copper cable 2 core. |
| 53 | Taking downcarefully water Geyser 25/50 ltrs capacity by unscrewiring nuts bolts, water inlet/outlet pipes from walls/foundation complete including refixing in position after carrying repairs like change of suitable geyser element,themostat,inlet outlet pipes,16 Amp plug top,replacement of burnt wire,safety valve,non return valve,inner and outer tank,solving geyser leakage problems etc. including making connection to the water inlet, outlet pipe, electric connection and testing complete all as specified and directed by Engineer-in-charge. Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as supply only under respective items of BoQ. (b) T&P required for repair/ maintenance such as Spaners, manpower etc, shall be included in the quoted rate of this item. |
| 54 | Prepairing the old painted surfaces byscraping andrubbing of old painted surface of 25/50 ltrs capacity geysers complete including painting withone thick coat of syntheticenamelwhite paint by spray gun complete including properdrying including writing MES No all as specified and directed by Engineer-in-Charge |
| 55 | Supply only flexible PVC insulated 40/0.0076 three core copper conductor cable from geyser to 15 amp socket/ Metal clad complete all as specified and directed by Engineer - in - Charge. |
| 56 | Supply onlygeyser element 1.5 KW rubber gasket type including rubber gasket and suitable for existing geysers all as sepecified and directed by Engineer- in - Charge. |
| 57 | Supply onlygeyser element 2 KW rubber gasket type including rubber gasket and suitable for existing geysers all as sepecified and directed by Engineer- in - Charge. |
| 58 | Supply onlyof geysersafety valve (Pressure release valve) complete suitable for vertical typegeyser all as sepecified and directed by Engineer- in - Charge |
| 59 | Supply only non return valve made out of brass fixed in vertical position of size 15mm dia all as sepecified and directed by Engineer- in - Charge. |
| 60 | Supply only ofISI marked PVC connection pipe complete with brass end terminal size 45 cm long. |
| 61 | Supply only ofthermostate switchpointer type/ thermocuttersuitable for 25/50 ltrs capacity geyser with adjustment knob complete all as specified and directed by Engineer-in-charge. |
| 62 | Supply and fix in replacement plug top 3 pin 15 Amps AC 230 volts. |
| 63 | S & F in repairs garden light of bamboo type IP 65 of capacity 9/8 watt, 6000K new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lihgting with high power LED as lihgt source with PCC base for fixing of lights with proper nut & bolts including electric connection wire complete all as specified and as directed.Make : Havells Cat part No LHEVBDP7IN6K008 or equivalent model of makes specified. |
| 64 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 65 | M&L for cutting the existing bituminous road / PCC hard standing upto 75cm in depth, 60cm in width, getting out excavated materials and making good the damaged portion after laying of pipes by returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate upto 30cm depth from top of the road all as specified and as directed. |
| 66 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 67 | Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. |
| 68 | Supply & laying DWC Cable duct pipe of size 50 mm bore confirming to IS :16205 Part 24for laying of LT cables etc complete with all accessoriesall as specified and directed. |
| 69 | Supply & laying DWC Cable duct pipe of size 60 mm bore confirming to IS :16205 Part 24for laying of LT cables etc complete with all accessoriesall as specified and directed. |
| 70 | Supply & laying DWC Cable duct pipe of size 110 mm bore confirming to IS :16205 Part 24for laying of LT cables etc complete with all accessoriesall as specified and directed. |
| 71 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable of size 240 sqmm, 3.5 core with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall sheathedincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning including taking out existing cable alongwith protection covers complete allasspecified and as directed. |
| 72 | All as per serial item No 71 above but 120 Sqmm 3.5 core |
| 73 | All as per serial item No 71 above but 95 Sqmm 3.5 core |
| 74 | All as per serial item No 71 above but 70 Sqmm 3.5 core |
| 75 | All as per serial item No 71 above but 50 Sqmm 3.5 core |
| 76 | All as per serial item No 71 above but 35 Sqmm 3.5 core |
| 77 | All as per serial item No 71 above but 25 Sqmm 3.5 core |
| 78 | All as per serial item No 71 above but 16 Sqmm 4 core |
| 79 | All as per serial item No 71 above but 10 Sqmm 4 core |
| 80 | S&F in repairs 80mm dia galvanised steel tube light grade for protection of cable complete all as directed by Engineer-in-Charge. |
| 81 | S&F in repairs 50mm dia galvanised steel tube light grade for protection of cable complete all as directed by Engineer-in-Charge. |
| 82 | S&F in repairs 40mm dia galvanised steel tube light grade for protection of cable complete all as directed by Engineer-in-Charge. |
| 83 | Supply & Fixing in replacement GI stripofsize 32 x 6 mm buried in ground/fixed to pole, wall including fixing clamp made out of 40x5 mm MS FI nut, bolt and washers complete including taking out old GI stripall as specified and directed by Engr -in -Charge. |
| 84 | S & F in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified & directed by Engg-in-charge. |
| 85 | S & F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified & directed by Engg-in-charge. |
| 86 | S & F in replacement Aluminium strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified & directed by Engg-in-charge. |
| 87 | Dismantling LT insulator any type any size complete all as specified and directed. |
| 88 | M & L for Preparing surfaces of LT pole by scrapping old paints and applying one coat red oxide primer and two coats of aluminium paint and writing \"T\" and Pole No in black paint etc complete all as specified and directed by Engr- in -Charge. |
| 89 | M & L for replacement of jump connection of two/four pole structure by using ACSR conductor weasel, alkathine pipe ,aluminium lugs, nuts, bolts etc. all as directed by Engineer-in-charge.Note:Rates includes Conductor,Pipes,Lugs,Nutbolts etc. |
| 90 | M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground in any type of strata (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth strip protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2020 and connection to earth test point all as specified incl testing on completion”.Note:The unit Rate includes earth strip and protection pipe up to (max 7.5 metre) from earth plate/earth point/test point. |
| 91 | Material and Labour for dehydration, filtration and cleaning of transformer oil, both indoor/outdoor/ pole mounted/plinth mounted 400/200 KVA, HT switch gear etc at different locations by suitable dehydration plant, testing of oil sample before and after dehydration for each transformer/equipment and results of transformeroil dielectric strength minimum upto 42 KV, recorded jointly by contractor andEngineer-in-Charge complete including all necessary tools, plants, transportation etc all as specified/directed by Engineer-in-Charge.Note : Oil for toping up/fresh fill shall be measured and paid seperately under relevant item. |
| 92 | Supply & filling of transformer oil in transformer in situ/ at site for toping up the level of oil having dielectric strength 40-60 KV during filling after initial filtration conforming to IS-335 of make POWER/INSOLE/UNIVERSAL (Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard) |
| 93 | M&L for repair to transformer pole mounted/plinth mounted of any capacity to stop the leakage of transformer by lifting core assembly with the help of chain pully block/crane, removing transformer oil, replacing cork sheet gasket 5mm thick, reassembling, the transformer completely refilling transformer oil, connecting HT/LT connection,and required for replacement of unserviceable nuts/bolts/washer all as directed by Engineer-in-charge(Note : Spares required shall be measured and paid separately ) |
| 94 | M&L for replacement of breather assembley with silica gel. |
| 95 | S & F in replacement of HVrod brass, 12mm dia, 300mm long with brass nuts, 2 Nos and rubber bushall as directed by Engineer-in-Charge. |
| 96 | S & F in replacement of LV rod brass 15mm/20mm dia, 300mm long with rubber bushing and brass nuts 2 Nos all as directed by Engineer-in-Charge. |
| 97 | S & F in replacement MCCB 400 Amp 4 pole 36 KA complete all as specified and directed. |
| 98 | S & F in replacement MCCB 250 Amp 4 pole 36 KA complete all as specified and directed. |
| 99 | S & F in replacement MCCB 160 Amp 4 pole 36 KA, complete all as specified and directed. |
| 100 | S & F in replacement MCCB 25-100 Amp 4 pole 16 KA complete all as specified and directed. |
| 101 | Supply and fixing 415V MCB TPN 100 Amps 10 KA \"C\" Curve complete with connection testing and commissioning. |
| 102 | Supply and fixing LT cable route indicator of cast iron of suitable size with height of 0.6 metre along the LT cable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge. |
| 103 | M&L for disconnecting and taking down U/S street light fittings/gate lights & garden lightsof any type/rating from pole or wall dismantling the same for necessary repair or replacment of U/S spares complete and refixing, connecting and testing the same all as specified and directed by Engineer-in-Charge.Notes:- (a) Spares/accessories required for replacement shall be measured and paid separately as supply only under respective items of BoQ. (b) T&P required for repair/ maintenance such as ladder, vehicle like crane, manpower etc, shall be included in the quoted rate of this item. |
| 104 | Supply only LED drivers compatible with industrial & outdoor LED fixtures/Sign boards as per existing make and modelSuitable for 30 Watt LED fitting |
| 105 | All as per serial item No 104 above but suitable for50 Watt LED fitting |
| 106 | All as per serial item No 104 above but suitable for 60 Watt LED fitting |
| 107 | Supply and fixing GI pipe bracket light grade of 40mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc complete and dismantling of existing old u/s brackets of all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m) |
| 108 | Supply and fixing GI pipe bracket light grade of 50mm dia ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc compltete and dismantling of existing old u/s brackets of all as specified and directed by Engineer-in-Charge. (Note: - The total length of the bracket shall be 1.5m) |
| 109 | Supply only 2.5 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old U/S cable all as directed. |
| 110 | Supply only 4 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old U/S cable all as directed. |
| 111 | Supply only 10 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old U/S cable all as directed. |
| 112 | S & F in repairsPVCweather proof, hinged door, junction box with Aluminium bus bar, 240V, Neutral link and 1No MCB SP of 6/10 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc with pole including dismantling of old junction box allasspecified and directed. |
| 113 | S & F in repairs of MD-XL Double metalized paper ( Extra low loss) capacitor bank for 3 phase 440 volts and 50 Hz system for permissible non leaner load 20 % of capacity 25 KVAr complete all as specified and as directed. |
| 114 | S & F in repair overload protection relay suitable for ML-4 FASD starter, MN-5, relay range 45-75, direct mounting on MNX 45-80 and currenct cap 160 A Max complete all as spd and as directed. |
| 115 | S & F in repair 3 pole power contactor block ML-4, IS/IEC-60947-4-1 and IEC-60947-4-1 type, 100A AC-1 and 70A-AC-3 type, 415V, 50 HZ complete all as specified and as directed. |
| 116 | S & F in repairs 3 pole power contactor block ML-3, 40A, AC3, 415V, 50 HZ and 45Amps-AC-1 type and IS/IEC-60947-4-1 complete all as specified and as directed. |
| 117 | S&F in repairs LED Flood Light 120 watt 230V AC outdoor typewith thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 118 | S&F in repairs LED Flood Light70 watt 230V AC outdoor typewith thermal management in multiple optics and equipped with IP65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 119 | S&F in repairs LED street light fittings 70 Watt 230 Volt AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 120 | S&F in repairs LED street light fittings 60 Watt 230 Volt AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 121 | S&FHasp and staple 100mm, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixedwith screws safety type including complete all as specified and directed. |
| 122 | Supply and fix in replacement25x20 cm size danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on LT pole & installations complete all as specified and directed. |
| 123 | M & L for Fiber glass plate plain 2 mm thick white in colour and writingletters in blue colour with fixing accessories complete all as specified and as directed by Engrs-in- Charge. |
| 124 | Repairs/Maint of Desert cooler,dismantling of Fan motor,pump,diverter,fan blade, water pipe , side panels,scrapping of rusted inside of tank & body, Painting of all dismantled items inside with one coat of redoxide metal primer and one coat of synthetic enamel paint of approved quality, reassembling fixing of woodwool with wiremesh, complete wiring and testing all as specified and directed (Spares replaced except wood wool shall be measured and paid for separately). |
| 125 | Dismantling of unserviceable cooler fan motor from desert cooler including rewinding of fan motor with super enamelled double speed copper windingof correct size and gauge including insulating materials such as insulating paper,varnishing and reassembling and testing complete. |
| 126 | S & F in repair/replacement of New Fan motor for Desert cooler 1400 RPM,450mm sweep 1/8 HP,single phase double speed complete with frame and blade , fixed in replacement complete confirming to relevant IS make: AUE/Usha/Kaitan |
| 127 | S & F in repair/replacement ofWater circulating pump motor 1/2 HP (Tullu pump) 230 V, single phase 1440 RPM suitable for any type of air cooler/desert cooler fixed complete all as spd and directed. |
| 128 | S & F in repair/replacement ofGalvanised iron Air Diverter grill 20\" size for desert coolers, fixed in replacement complete all as spd and directed. |
| 129 | S & F in repair/replacement ofFlexible cord PVC insulated and sheathed,3 core flexible with copper conductor of size 2.5 sqmm., fixed in replacement complete all as spd and directedMake:- Polycab,Anchor,Finolex |
| 130 | Supply and fix bottom water tray /tank for desert coolers of standard size and gusge as per sample |
| 131 | Taking out hermetically sealed compressor unit (uncut) of refrigerator, single phase, 240 Volts, AC Supply for 165 to 180 ltr capacity of any make and replacing sealed unit with reconditioned sealed unit of same brand including following work all as specified and as directed. (Existing make -Godrej/ Whirlpool/LG/ Voltas/ Carrier/ Blue star/ Kirloskar / Tuchmesh/ Usha) (i) Connection to suction/discharge pipewith necessary repairs and brazing. (ii) Replacing capillary tube of existing size and copper liquid filters. (iii) Flushing of entire system before gas charging . (iv) Gas charging and testing the unit to the entire satisfaction complete. |
| 132 | All as per serial item No 131 but compressor unit of refrigerator 190 to 290 litre capacity. |
| 133 | All as per serial item No 131 but compressor unit of deep freezer 200 to 410 litre capacity. |
| 134 | S&F in repairs, heaterfor frost freerefrigerator of any type and capacity, as per existing make & model all as specified and as directed. |
| 135 | S&F in repairs,freezer chest with cooling coil suitable for refrigerator 165 to 290 litre capacity as per existing make & model and fixing, connecting and testing completeall as specified and as directed. |
| 136 | S&F in repairs,freezer chest with cooling coil suitable for Deep freezer of 300 to 320 litre capacity as per existing make & model all as specified and as directed. |
| 137 | S&F in repairs, over load protector suitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed. |
| 138 | S&F in repairs,thermostat switch (auto de-frost) suitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed. |
| 139 | S&F in repairs, electric lamp pin/ threaded type, 240 volts, AC supplysuitable for refrigerator of 165 to 320 ltr capacity as per existing make & model all as specified and as directed. |
| 140 | S&F in repairs, leg, suitable for refrigerator/Water Cooler of any capacity as per existing make & model all as specified and as directed. |
| 141 | S&F in repairs, relay, suitable for refrigerator/deep freezer upto 410 ltr capacity as per existing make & model all as specified and as directed. |
| 142 | S&F in repairs, capillary tube and drier filter, suitable for refrigerator of 165 to 320 ltr capacitywith brazing, nitrogen flushing, leak testing and gas charging all as specified and as directed.Note:- Charging of gas as specified by manufacturer will be measured and paid separately under respective item. |
| 143 | Taking out old hermetically sealed compressor unit (uncut) from water cooler,storage type, 40/80 ltr/hr cooling capacity and replacing the sealed unit with factory made new sealed unit of same brand as per existing, including the following work all as specified and as directed.(Existing make - Godrej, Whirlpool, LG, Voltas, Carrier, Blue star, Kirloskar,Tuchmesh, Usha) (i) Connection to suction/discharge pipe with necessary repairs and brazing. (ii) Replacing capillary tube of existing size and copper liquid filters. (iii) Flushing of entire system before gas charging. (iv) Gas charging and testing after repairs including installing the machine at site and testing on full load for its smooth functioning complete. |
| 144 | All as per serial item No 143 but for water cooler 60/120 ltr/hr cooling capacity. |
| 145 | All as per serial item No 143 but for water cooler 120/150 ltr/hr cooling capacity. |
| 146 | S&F in repairs, copper condensing coil with fixing arrangement of water cooler of 40/80litre capacity complete all as specified and as directed. |
| 147 | S&F in repairs, fan blade for motor suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed. |
| 148 | S&F in repairs, thermostat suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed. |
| 149 | S&F in repairs, relay, suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed. |
| 150 | S&F in repairs, over load protector, suitable for water cooler of 40/80 litre capacity as per existing make & model all as specified and as directed. |
| 151 | S&F in repairs, capacitor 10 mfd including necessary electrical connections, lugs, insulation tape etc complete suitable for water cooler of 40/80 litre capacity, all as specified and as directed. |
| 152 | S&F in repairs, PVC flexible drain pipe length 2 meter, with proper fixing clip as per existing type & size suitable for water cooler any capacity all as specified and as directed. |
| 153 | S&F in repairs, fan motor, 240 volts, single phase, AC supply, suitable for water cooler of60/120 & 150/150 litre capacity all as specified and as directed. |
| 154 | S&F in repairs, copper condensing coil with fixing arrangement of water cooler of 60/120 & 150/150 litre capacity all as specified and as directed. |
| 155 | S&F in repairs, fan blade for motor, suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed. |
| 156 | S&F in repairs,thermostate, suitable for water cooler of 60/120 & 150/150 litre capacity, as per existing make & model all as specified and as directed. |
| 157 | S&F in repairs, relay suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed. |
| 158 | S&F in repairs, over load protector suitable for water cooler of 60/120 & 150/150 litre capacity as per existing make & model all as specified and as directed. |
| 159 | S&F in repairs, internal wiring with PVC insulated copper conductor wire with lugs and thimbles complete suitable for water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed. |
| 160 | M&L in repairs, rewinding of fan motor suitable for water cooler of 60/120 & 150/150 litre capacity of any make with super enameled copper wire of existing size and weight as required including replacement of bushing and capacitor of 4.0 mfd complete all as specified and as directed. |
| 161 | S&F in repairs,PTMT float valve assembly of 15 mm bore with plastic ball with suitable connections galvanized iron nipple 3” long and suitable GI sheet for fixing float valve suitable for water cooler of any make all as specified and as directed. |
| 162 | S&F in repairs, chromium plated 15mm bore stop cock, cast copper alloy, ISI marked, all as specified and as directed. |
| 163 | S&F in repairs, GI pipe connector (male and female) 15mm bore pipe all as specified and as directed. |
| 164 | S&F in repairs, 15 mm dia, concussive push taps of stainless steel alloy, screwed for iron pipe for water cooler all as specified and as directed. |
| 165 | Dusting using blower and cleaning the housing from inside/out side, cooling system, cooling coil, condenser,capillary tube complete washingwith CTC liquid and leak detection, testingfor water cooler of 40/80, 60/120 & 150/150 litre capacity all as specified and as directed. |
| 166 | M&L for gas charging to compressors of refrigerator, 165 to 180 litre capacity to its full capacity with specified grade of refrigerant including other connected process required for gas charging and testing complete all as specified and as directed. |
| 167 | All as per serial item No 166 but for refrigerator,190/200/290 litre capacity. |
| 168 | All as per serial item No 166 but for water coolerof 40/80 litre capacity. |
| 169 | All as per serial item No 166 but for water coolerof 60/120 litre capacity. |
| 170 | All as per serial item No 166 but for water coolerof 150/150 litre capacity. |
| 171 | All as per serial item No 166 but for deep freezer 200 to 410 litre capacity |
| 172 | M & L for Taking out hermetically sealed compressor unit(uncut) from the Split/Window Air conditioner of any make & type of 1.5 TR capacity and replacing the sealed unit with new sealed unit complete including following work all as specified and as directed. (Existing Make:- Voltas/ Carrier/ Blue star/ Kirloskar/ Tuchmesh/ Usha/ Godrej/ Whirlpool/ LG/ Kenstar) (i) Connection to suction/discharge pipe with necessary repair and brazing. (ii) Replacing the capillary tubes of existing size and copper liquid filter. (iii) Flushing of entire system before gas charging.(iv) Gas charging and testing after complete repairs including installation of the machine at site and testing on full load for its smooth functioning complete. |
| 173 | All as per serial item No 172 but for Air Conditioner of 2.0 TR capacity. |
| 174 | S&F in repairs,relay for existing make and model of split type AC of capacity 1.5 TR single phase, 240 Volts, AC supply including connecting and testing of relayall as specified and as directed. |
| 175 | S&F in repairs, thermostat with switch for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 176 | S&F in repairs, starting capacitor 80/100 mfd or suitable capacity including necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 177 | S&F in repairs, PCB electronic circuit including LCD of indoor/ outdoor unit of 1.5 TR of existing make and model of split AC all as specified and as directed. |
| 178 | S&F in repairs, remote for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 179 | S&F in repairs, swing assembly complete made of PVC, heavy duty for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 180 | S&F in repairs, swing motor, single phase, AC supply, for indoor unit.of existing make and model ofsplit type AC of capacity 1.5 TR all as specified and as directed. |
| 181 | S&F in repairs, running capacitor 45/50 mfdincluding necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 182 | S&F in repairs, over load protector for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 183 | S&F in repairs, capillary tube and drier filter of any make of 1.5 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete.all as specified and as directed.Note:- Charging of gas as specified by manufacturer will be measured and paid under respective item . |
| 184 | S&F in repairs, relay as per existing make and model of splittype AC of capacity 2.0 TR, single phase, 240 Volts, AC supply including connecting and testing of relay all as specified and as directed. |
| 185 | S&F in repairs, thermostat with switch ofexisting make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 186 | S&F in repairs, PCB electronic circuit including LCD for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 187 | S&F in repairs, remote for existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 188 | S&F in repairs, swing assembly complete made of PVC, heavy duty of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 189 | S&F in repairs, swing motor, single phase AC supply for indoor unit.of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 190 | S&F in repairs, running capacitor 50/60 mfd or as per existing capacity including necessary electrical connections, lugs, insulation tape etc for splittype AC of capacity 2.0 TR all as specified and as directed. |
| 191 | S&F in repairs, over load protector of existing make and model of splittype AC of capacity 2.0 TR all as specified and as directed. |
| 192 | Servicing of AC, window type, 1.5 TR capacity of any make, by cleaning the whole equipment, washing of filters, minor adjustments/repair, washing condenser unit all as specified and as directed. |
| 193 | All as per serial item No 192 but AC, split type, 1.5/2.0 TR capacity, indoor and out door unit. |
| 194 | M&L for gas charging to compressors of AC, Split type, 1.5 /2 TRcapacity of any make, installed machine/equipment to its full capacity with specified grade (as per OEM recommended) of refrigerant including other connected process required for gas charging and testing complete all as specified and as directed. |
| 195 | Removal and Refixing of split AC of capacity 1.5/2.0 TR including making hole in the brick/ shelter/ stone walls and making connections, fixing of brackets and insulating pipe lines with nitrile rubber, brazing of copper tubes including testing/ commissioning complete as required at site, including shifting of service connection, metal clad box and voltage stabilizer to the new location all as required. SOP is to be followed by proper pumping down of refrigerant gas before dismantling all as specified and as directed.(ii) Refrigerant pipes shall be measured and paid in respective item. |
| 196 | S&F in repairs, connecting and testing copper refrigerant pipes, along with proper insulation with nitrile rubber of suitable size for incoming and outgoing pipes complete all as required at site for 1.5/2.0 TR TR split AC all as specified and as directed. Note : One run of both copper pipes incoming and outgoing shall be measured as 01 RM unit for payment purpose |
| 197 | S&F in repairs, nylon pipe, cotton breaded, size 15mm dia, suitable for drain of split type AC, capacity 1.5/2.0 TR all as specified and as directed. |
| 198 | S&F in repairs, mounting frame/ stand including fasteners and nut bolts suitable for outdoor unit of split AC of any size complete all as required at site all as specified and as directed. |
| 199 | S&F in repairs, sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB and plug top, single pole, 20 amp, 240 volts complete all as specified and as directed. |
| 200 | S&F in repairs, metalic plug top, 3 pin for AC point, 15 Amps single phase, 240 volts, AC ISI marked, all as specified and as directed. |
| 201 | S & F in repairs outdoor unit kit of split type AC of capacity 1.5 TR complete with copper condensing coil, coil frame, wiring kit starting and running capacitor, relay condensing motor with blade and connected accessories complete all as directed, Note :- Compressor of split AC will be measured and paid saparately. |
| 202 | S & F in repairs Indoor unit kit of Split type AC of capacity 1.5 TR coil made up ofcopper with display for temprature indication and all motor, blower/blade, PCB etc, complete all as specified and directed. |
| 203 | Supply and fix in repairs foam insulation sheet 6 mm thick for duct covering of air cooling system complete all as specified and as directed. |
| 204 | Inspection, maintenance and servicing of DG set,200 KVA, including alternator, electric panel board connection to DG Set for routine check (\"A\" check) of DG set for smooth functioning and carriying out maintenance as under :- Service (a)Checking engine oil level and topping up as and when required NOTES : (a) Oil shall be measured and paid separate. (b) Checking and adjusting the belt for tension and replacemnt of belt (c) Belt shall be measured and paid separate.(c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleanerment.Note : Replacement of Air Cleaner shall be measured and paid separately.(g) Checking engine alternator coupling, mounting boltsand alignment. (h)Tighting all nut, bolts, in alternator terminal block.(j)Checking ofalternator carbon brush and connections in alternator(k)Checking and tighting of all connection in DC control wiring.(l)Checking ofall radiator rubber hose and replacementif required.NOTE : Hose pipes shall be measured and paid separately(m)Checking and recording oil pressure, water and oil temperature(n) Checking anti vibration mounting and replacement if required.NOTE: Antivibration pad shall be measured and paid separately (o) Checking throttle linkage(p) Checking battery for cell test, electrolyte level, gravity and topping up to required level(q) Routine check / repair work of panel, switch, MCCB, main switch, all contactor, engine control unit. |
| 205 | All as per serial item no. 204 but for 25 KVA DG set. |
| 206 | Material and labour required for `B\" CHECKinspection, maintenance, servicing of DG set 200 KVA includingitems covered in `B\" check of DG set for smooth functioning and carriying out maintenance complete all as per OEM instructions and as directed under :- (a) Repeat the activities of \"A\" check (b)Replacing lubricant oil Note:- Lub Oil are Paid separately. (c) Replacing lubricant oil filter element with `O\" ring (d) Replacing fuel filter element(e) Replacing Bypass Filter(f) Replacing Air Filter(g) Replacing Governer oil (h) Replacing coolant NOTES : i) `B\" CHECK ONCE INSIX MONTH OR 300-350 HRS RUNNING OF DG SET WHICHEVER IS EARLIER ii) `B\" check kit, coolant, Lubricant Oil shall be measured and paid seperately under relevant item. |
| 207 | All as per serial item No. 206 but for 25 KVA DG set |
| 208 | Supply only B\" Check Kit for DG set 200 KVA, complete allas per OEM instructions and as specified and as directed.Note : Quoted rate shall be included for oil filter (1.00 Ltr/0.5 ltr), Air Filter, Fuel/Diesel filter, by pass filter with element etc. |
| 209 | All as per serial item No. 208 but for 25 KVA DG set. |
| 210 | Disconnecting all the connections from alternator of 200 KVADG set,removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing, cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, rewinding & reassembling, dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as specified and as directed. |
| 211 | All as per serial item No. 210 butalternator of 25 KVA DG set. |
| 212 | M&L in repair/replacement, battery Lead with Brass Terminals of DG Sets of capacity 25/200 KVA all as specified and as directed. |
| 213 | M&L in repair/replacement, emergency shutdown switch with wiring of DG Set 25 KVA to 200 KVA all as specified and as directed. |
| 214 | M&L in repair/replacement, fan belt of DG set 200 KVA all as specified and as directed. |
| 215 | M&L in repair/replacement, fan belt of DG Set 25 KVA all as specified and as directed. |
| 216 | M&L in repair/replacement, oil seal of DG Set 25 KVA to 200 KVA all as specified and as directed. |
| 217 | M&L in repair/replacement, fuel level float ball of DG Set 200 KVA all as specified and as directed. |
| 218 | M&L in repair/replacement, radiator hose pipe set with clamps of DG Set 200/25 KVA all as specified and as directed. |
| 219 | M&L in repair/replacement, air filter hose pipe set with clamps of DG Set 200/25 KVA all as specified and as directed. |
| 220 | M&L in repair/replacement, dial type mechanical fuel level gauge meter of DG Set 200 KVA all as specified and as directed. |
| 221 | M&L in repair/replacement, dial type mechanical water Temp gauge meter of DG Set 200/25 KVA all as specified and as directed. |
| 222 | M&L in repair/replacement, dial type mechanical Volts gauge meter of DG Set 200 KVA all as specified and as directed. |
| 223 | M&L in repair/replacement, coolant drum assembly of DG Set 200 KVA all as specified and as directed. |
| 224 | M&L in repair/replacement starter solenoid switch/valve of DG Set 200 KVA all as specified and as directed. |
| 225 | M&L for leakage rectification of radiator, cleaning, pressure testing etc for any make and capacity DG Set complete as required and directed. |
| 226 | Supply only engine oil 15W40 of approved and standard in seal packed containers all as specified and as directed. Make : Servo/ BPL/IOC/ Castrol |
| 227 | Supply only coolant of approved and standard in seal packed containers all as specified and as directed. Make:K cool Super plus 50-50 Premix, Castrol Radicool Premix, Greaves kool |
| 228 | Supply only battery water with electrolyte mix all as specified and as directed. |
| 229 | S&F in repair/replacement, of battery 12 V, Capacity 180 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals with 36 month warranty complete as directed by Engr-in-Charge. |
| 230 | S&F in repair/replacement, of battery 12 V, Capacity 88 AH, maintenance free battery, 12 Volt initially charged with suitable size of copper leads and brass terminals with 36 month warranty complete as directed by Engr-in-Charge. |
| 231 | S&F in repair/replacement Auxiliary transformer primary (230 V AC) Scondary (15-0-15 Volt ac) of 25 KVA stabilizer fixed in replacement complete all as specified and directed. |
| 232 | S&F in repair/replacement Bush assembly of 25 KVA stabilizer fixed in replacement complete all as spd and directed. |
| 233 | S&F in repair/replacement Relay -18V/1 CO of 25 KVA stabilizer in fixed replacement complete all as specidied and directed. |
| 234 | S&F in repair/replacement Air filter complete of suitable sizes for the 200 KVA , DG Set, fixed in replacement . Make : Greaves |
| 235 | S&F in repair/replacement Air filter complete of suitable sizes for the 25 KVA , DG Set fixed in replacement complete all as specified and directed. Make : Kirloskar |
| 236 | M & L for Auto control wiring with PVC insulated copper wire multistranded of 4 Sqmm 2 core cable for200 KVA DG Set with all accessories , fixed in replacement complete all as directed. |
| 237 | S&F in repair/replacement Flexible fuel pipe (from Feed pump to fuel filter, fuel filter to fuel pump and pre-filter to tank unit) of suitable size with banzo washers for DG Set 200 KVA make : Greaves, fixed in replacement complete all as specified. |
| 238 | S&F in repair/replacement Flexible fuel pipe (from Feed pump to fuel filter, fuel filter to fuel pump and pre-filter to tank unit) of suitable size with banzo washers for DG Set 25 KVA make : Kirloskar, fixed in replacement complete all as specified. |