Tender For Soil Investigation For Provision Of Defi Offers Md Accommodation At Abohar Milstn

Issued by Statutory Bodies & Commissions/Committees · abohar, Punjab
Tender Value
60180
Estimated cost
Bid Submission
14 Dec 2024
0 days left
EMD
1203
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
abohar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Soil Investigation For Provision Of Defi Offers Md Accommodation At Abohar Milstn; 1 Bore hole dia shall be 150mm. depth of bore shall be decided as per the site condition and may be taken 15 m for N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided : (i) Grain size analysis, identification & classification of soil.(ii) Unit weight (bulk density), natural moisture content, liquid limit , plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Ø analysis). (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specified in table-1 of IS 1893 (Part-I) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Reccomendation for filling under floor and filling under protection including plinth protection. (xii)Recommendation of SBC at different depth of foundation 1.2m, 1.5m, 1.8m, 2.0m and 2.5m for each building and/or most suitable strata depth for resting foundation as per type of building/Soil investigation details. SBC and its calculation based on N value, shear strength and settlement criteria SBC to be given for following Size 1.2m x1.2m ,1.5m x 1.5m, 2m x 2m, 2.5m x 2.5m, SBC values shall be calculated based on C-Øanalysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xiii) if pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for underreamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv)Recommendations regarding type of foundaion to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilisation required, if any (xv) Borehole position duly marked on plan and their distances from adjacent prominet reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE,AGE & soil consultant.(xvi) Undisturbed soil sample shall be collected at 1.0 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modulus of subgrade reaction , Direct shear test on dusturbed soil sample(xvii) Submission of report in sextriplicate. Note : Colour photograph A4 size paper of the site with the locations of the boreholes duly fiagged should be submitted. The photograph should also preferably include any reference structure and ttheeh identification of the same be marked. 2 Chemical analysis of soil and recommendation and type of cement to be used for RCC foundationcomplete all as specified and directed by Engineer-in-Charge 3 Chemical analysis of ground water (water to be obtained from bottom of bore hole). complete all as specified and directed by Engineer-in-Charge

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Dec-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-Dec-2024

BOQ

Name of Work: SOIL INVESTIGATION FOR PROVN OF DEFI OFFRS MD ACCN AT ABOHAR MILSTN
Sl. No. Item Description
1Bore hole dia shall be 150mm. depth of bore shall be decided as per the site condition and may be taken 15 m for N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided : (i) Grain size analysis, identification & classification of soil.(ii) Unit weight (bulk density), natural moisture content, liquid limit , plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Ø analysis). (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specified in table-1 of IS 1893 (Part-I) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Reccomendation for filling under floor and filling under protection including plinth protection. (xii)Recommendation of SBC at different depth of foundation 1.2m, 1.5m, 1.8m, 2.0m and 2.5m for each building and/or most suitable strata depth for resting foundation as per type of building/Soil investigation details. SBC and its calculation based on N value, shear strength and settlement criteria SBC to be given for following Size 1.2m x1.2m ,1.5m x 1.5m, 2m x 2m, 2.5m x 2.5m, SBC values shall be calculated based on C-Øanalysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xiii) if pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for underreamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv)Recommendations regarding type of foundaion to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilisation required, if any (xv) Borehole position duly marked on plan and their distances from adjacent prominet reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE,AGE & soil consultant.(xvi) Undisturbed soil sample shall be collected at 1.0 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modulus of subgrade reaction , Direct shear test on dusturbed soil sample(xvii) Submission of report in sextriplicate. Note : Colour photograph A4 size paper of the site with the locations of the boreholes duly fiagged should be submitted. The photograph should also preferably include any reference structure and ttheeh identification of the same be marked.
2Chemical analysis of soil and recommendation and type of cement to be used for RCC foundationcomplete all as specified and directed by Engineer-in-Charge
3Chemical analysis of ground water (water to be obtained from bottom of bore hole). complete all as specified and directed by Engineer-in-Charge

AI Tender Summary

OUR REF NO 46439347
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 60180
LAST DATE 14-12-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Soil Investigation For Provision Of Defi Offers Md Accommodation At Abohar Milstn; 1 Bore hole dia shall be 150mm. depth of bore shall be decided as per the site condition and may be taken 15 m for N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided : (i) Grain size analysis, identification & classification of soil.(ii) Unit weight (bulk density), natural moisture content, liquid limit , plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Ø analysis). (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specified in table-1 of IS 1893 (Part-I) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Reccomendation for filling under floor and filling under protection including plinth protection. (xii)Recommendation of SBC at different depth of foundation 1.2m, 1.5m, 1.8m, 2.0m and 2.5m for each building and/or most suitable strata depth for resting foundation as per type of building/Soil investigation details. SBC and its calculation based on N value, shear strength and settlement criteria SBC to be given for following Size 1.2m x1.2m ,1.5m x 1.5m, 2m x 2m, 2.5m x 2.5m, SBC values shall be calculated based on C-Øanalysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xiii) if pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for underreamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv)Recommendations regarding type of foundaion to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilisation required, if any (xv) Borehole position duly marked on plan and their distances from adjacent prominet reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE,AGE & soil consultant.(xvi) Undisturbed soil sample shall be collected at 1.0 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modulus of subgrade reaction , Direct shear test on dusturbed soil sample(xvii) Submission of report in sextriplicate. Note : Colour photograph A4 size paper of the site with the locations of the boreholes duly fiagged should be submitted. The photograph should also preferably include any reference structure and ttheeh identification of the same be marked. 2 Chemical analysis of soil and recommendation and type of cement to be used for RCC foundationcomplete all as specified and directed by Engineer-in-Charge 3 Chemical analysis of ground water (water to be obtained from bottom of bore hole). complete all as specified and directed by Engineer-in-Charge
Basic Detail
Tender No GE ABH-07/24-25/E3
Bidding Type Tender
Location
City abohar
State Punjab
Key Dates
Publish Date 07 Dec 2024
Submission Date 14 Dec 2024
Open Date 16 Dec 2024
Finance
Tender Value 60180
Tender Fee Ref. Documents
EMD 1203
Exemption Available
Document List
f0cee546-01d8-4c05-b286-a1aa315960d7.html
BOQ_768154.xls
Tendernotice_1.pdf
Termsconditions.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 07, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 14, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 14, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 16, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f0cee546-01d8-4c05-b286-a1aa315960d7.html

xls

BOQ_768154.xls

pdf

Tendernotice_1.pdf

pdf

Termsconditions.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender