| 1 | Sub-Head : Concrete Work Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 2 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 3 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Sub-Head : Woodand P.V.C. WorkProviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 5 | Kiln seasoned and chemically treated hollock wood. |
| 6 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) |
| 7 | Kiln seasoned and chemically treated hollock wood |
| 8 | 35 mm thick shutters |
| 9 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 10 | Particle Board 12 mm thick |
| 11 | Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 12 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 13 | Kiln seasoned and chemically treated hollock wood |
| 14 | 30 mm thick |
| 15 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 16 | 35 mm thick shutters. |
| 17 | with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood. |
| 18 | 30 mm thick shutters. |
| 19 | with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood |
| 20 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : |
| 21 | 250x16 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 23 | 200x10 mm |
| 24 | 100x10 mm |
| 25 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 26 | 100 mm |
| 27 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 28 | Twin rubber stopper |
| 29 | Sub-Head : Steel WorkStructural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 30 | Sub-Head : FlooringCement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 31 | 40 mm thick with 20 mm nominal size stone aggregate |
| 32 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 33 | 18 mm thick. |
| 34 | Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. |
| 35 | 40 mm wide and 4 mm thick. |
| 36 | Sub-Head : Finishing12 mm cement plaster of mix : |
| 37 | 1:6 (1 cement: 6 fine sand) |
| 38 | Finishing walls with water proofing cement paint of required shade : |
| 39 | Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 41 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 43 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 44 | Old work (one or more coats) |
| 45 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 47 | One or more coats on old work. |
| 48 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 49 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 50 | Sub-Head : Repairs to BuildingsRepairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 51 | With cement mortar 1:4 (1cement: 4 fine sand). |
| 52 | Renewing glass panes, with wooden fillets wherever necessary: |
| 53 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 54 | Sub-Head : Dismantling and DemolishingDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 55 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 56 | Sub-Head : Sanitary InstallationsProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 57 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 58 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 59 | 10 litre capacity - White |
| 60 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 61 | Semi rigid pipe |
| 62 | 32 mm dia |
| 63 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 64 | Rectangular shape 453x357 mm |
| 65 | Sub-Head : Water SupplyProviding and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 66 | 15 mm nominal bore |
| 67 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 68 | 15 mm nominal bore |
| 69 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 70 | 15 mm nominal bore |
| 71 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 72 | 45 cm length |
| 73 | 15 mm nominal bore |
| 74 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 75 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 76 | Groutingwith cement mortar 1:3 (1 cement : 3 fine sand) mixed with water proofing chemical of pidilite, Dr. Fixit or equivalent in required proportion for flat tile bricks on top of mud phaska as per direction of E-in-Charge : |
| 77 | Providing and fixing fly proof galvanized M.S. wire gauze to windows and clerestory windows using galvanized M.S. wire gauze with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm using kail wood beading wherever required. |
| 78 | Resetting of wooden door/windows/ cupboard shutters by cutting, sawing (taking out the shutter and refixing if required) including cost of providing minor items like nails/screws etc. complete as per direction of Engineer in charge. |
| 79 | Repair of existing R.C.C. Ceiling/ projections/members at all floor levels and at any height by removing &takingoutthe worn out concrete, cleaning the concretesurfacewithwirebrush and exposedreinforcementwithsandpaper, preparingthe surface for plasteringby applying thick cement slurry, plastering the surface with cement mortar 1 : 3 (1 cement: 3 coarse sand) ofthickness12mm to 30 mminoneor twolayersallcomplete including necessary scaffolding or shuttering if requiredaspersiterequirementand thedirection of Engineer-in-charge. (Area of RCC surface repaired upto 2.00 square metre shall be taken as one job) |
| 80 | Credit for old dismantled/unserviceable material: - |
| 81 | Fuel wood |
| 82 | Old Brass bib cock/stop cock/CP pillar cock,etc.of all dia |
| 83 | PVC/China ware low level cistern |
| 84 | PVC water tank (Upto 500 liter capacity) |