Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-12-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-12-2024 |
| Sl. No. | Item Description |
| 1 | S&F 15mm bore Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe complete all as specified and as directed. |
| 2 | S&F 20mm bore Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe complete all as specified and as directed. |
| 3 | Supply & Laying of CPVC Pipes 20mm outer dia bore SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all pipe fittings and including taking up or down in the existing pipe line complete all as specified and as directed. |
| 4 | Supply & Laying of CPVC Pipes 25mm outer dia bore SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all pipe fittings and including taking up or down in the existing pipe line complete all as specified and as directed. |
| 5 | Supply & Laying of CPVC Pipes 32mm outer dia bore SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all pipe fittings and including taking up or down in the existing pipe line complete all as specified and as directed. |
| 6 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any description along with tank cover and existing ball valvesand S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 7 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any description along with tank cover and existing ball valve and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 8 | S&F in repairs covers for Rotational moulded polyethylene water tank of any capacity complete all as specified and as directed. |
| 9 | M & L in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20 mm dia bore pipes complete all as specified and as directed. |
| 10 | M & L in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes complete all as specified and as directed. |
| 11 | S&F in repairs Ball valves 20mm bore (min. weight 20mm-210 gms) high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe & fixed complete all as specified and as directed. |
| 12 | S&F in repairs 15mm dia bib taps fancy type, chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 13 | S & F in repairs 15mm Bib taps cast fancy type, chromium plated, fancy type with crutch or butterfly handle, screwed for iron pipe or for brass ferrule of make that shall match with existing fitting i.e., Jaquar or its equivalent as approved complete all as specified and directed. |
| 14 | S&F in repairs fortwo waybib tap 15 mm bore chromium plate with crutch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union of make that shall match with existing fitting i.e., Jaquar or its equivalent as approved complete all as specified and directed. |
| 15 | S&F in repairs fortwo waybib tap 15 mm bore chromium plate with crutch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union of make that shall match with existing fitting i.e., Prayag or its equivalent as approved complete all as specified and directed. |
| 16 | S&F in repairs Vitreous china Wash Hand Basin,white, flat back of size 550x400mm excludingtaps, waste, chainand plug and porcelain stopper out including bracketscomplete all as specified and directed. |
| 17 | S&F in repairs vitreous chain wash basin of oval type including counter foul granite platform waste coupling, waste pipe and brackets etc., complete all as specified and directed. |
| 18 | S & F in repairs 15 mm dia bore pillar tap long neck with aerator fancy type cast copper alloy with crutch handle screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe or for brass ferrule etc. of make that shall match with existing fitting i.e., Jaquar or its equivalent as approved complete all as specified and directed. |
| 19 | S&F in repairs 15mm dia pillar taps fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipescomplete all as specified and directed. |
| 20 | S&F in repairs angular stop cock 15 mm dia brass chromium plated fancy type with long shank, screwed down high pressure with crutch or butter fly handle screwed down both ends for iron pipe or for union of make that shall match with existing fitting i.e.,Jaquar or its equivalent as approved complete all as specified and directed. |
| 21 | S&F in repairs15mm diaangle cock with flange, chromium plated. of make that shall match with existing fitting i.e., Prayag or its equivalent as approved complete all as specified and directed. |
| 22 | S & Fin repairs Vitreous china wash down water closet (pedestalpattern ) white (excluding fixing bolts flushing cistern and flush pipe ) complete all as specified and directed. |
| 23 | S&F in repairs vitreous china wash down water closet pan, dual flush system cascade dual flush selected colour with built in cistern floor mounted type with Por S trap and matching seat cover including all fittingscomplete all as specified and directed. |
| 24 | S&F in repairs Vitreous china squatting pan Orissa pattern size 550x440mm white with integral foot rest (excl flushing cistern and flush pipe ) and making good to floorcomplete all as specified and directed. |
| 25 | S&F in repairs PVC low level flushing cistern 10 ltrs capacity with complete accessories, PVC flush pipe, PVC over flow pipe, etc.and connected to water closet as per manufactures instruction and asdirectedincluding removal of existing cistern etc. |
| 26 | S&F in repairs Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe & waste pipe)complete all as specified and directed. |
| 27 | S&F in repairs 15mm PVC connection 450mm long of superior quality complete all as specified and directed. |
| 28 | S&Fin repairsWall mixer 3-in-1 system with provision for both telephone shower and over head showerof make that shall match with existing fitting i.e., Jaquarcomplete all as specified and directed. |
| 29 | S&F in repairs health faucet (hand shower with 1 M flexible tube with wall hook, chromium platedof make that shall match with existing fitting i.e., Jaquarcomplete all as specified and directed. |
| 30 | S&F in repairs toilet paper holder with flap recessed type matt chromium plated of make that shall match with existing fitting i.e., Jaquarcomplete all as specified and directed. |
| 31 | S&F in repairs soap dish, matt finished chromium plated (MCH/Colour CP) of make that shall match with existing fitting i.e., Jaquarcomplete all as specified and directed. |
| 32 | S&Fin repairsplastic water closet seat cover, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device of make fixed withCI brackets of make that shall match with existing fitting i.e., Prayag complete all as specified and directed. |
| 33 | Supply and Fix looking mirror 600mm x 450mm bevelled edgeon selected quality mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and framed with aluminium channel all round etc., complete fixed in repair complete all as specified and directed. |
| 34 | Supply and Fix looking mirror of size exc 0.75sqm but n exc 1.10sqm bevelled edgeon selected quality mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and framed with aluminium channel all round etc., complete fixed in repaircomplete all as specified and directed. |
| 35 | S&F in repair PVC cabinet mirror PTMT of size 400 x 500mm with sided shelves fancy type of superior quality of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 36 | S&Fin repairs PVC waste pipe for wash hand basin/Urinal (size 31/32mm x 800mm length) of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 37 | S&Fin repairs PVC waste pipe for Sink waste pipe (size 38/40mm x 1150mm length) of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 38 | S&F in repairs towel rail 600mm long with flanges, chromium plated of make that shall match with existing fitting i.e., Jaquarcomplete all as specified and directed. |
| 39 | S&F in repairscorner glass shelf superior quality matt finished chromium plated (MCH/Colour CP ) with bracket and fittings ofmake that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 40 | S&F in repairscorner glass shelf superior quality matt finished chromium plated (MCH/Colour CP ) with bracket and fittings of make that shall match with existing fitting i.e.,Jaquarcomplete all as specified and directed. |
| 41 | Supply and fix in repair CP towel ring of make that shall match with existing fitting i.e., Prayagor its equivalent as approved complete all as specified and directed |
| 42 | Supply and fix in repair CP towel ring of make that shall match with existing fitting i.e., Jaquaror its equivalent as approved complete all as specified and directed |
| 43 | S&F In repairCP overhead shower ABS round with 225mm brass arm & flange of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 44 | S&F In repairCP overhead shower ABS round with 225mm brass arm & flange of make that shall match with existing fitting i.e., Jaquar or its equivalent as approved complete all as specified and directed |
| 45 | S&F in repairCP cockroach trap (127mmx127mm) with waste hole of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 46 | S&F in repairSS round grating for floor trap of male and female pattern 4\" (101mm)of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 47 | S&F in repairs bottle trap of CP having minimum water seal of 25mm 32mm bore dia of discharge pipecomplete all as specified and directed. |
| 48 | S&F In repair 32mm brass full thread SS waste coupling for wash hand basin of make that shall match with existing fitting i.e., Prayagcomplete all as specified and directed. |
| 49 | PVC (SWR) pipes 110mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor as in spouts etc complete including dismantling existing pipes all as specified anddirected. |
| 50 | PVC (SWR) pipes 75mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor complete as in spouts etc including dismantling existing pipes all as specified anddirected. |
| 51 | PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified anddirected. |
| 52 | PVC (SWR) bends with oval access door 75mm fixed in repairs complete all as specified anddirected. |
| 53 | PVC (SWR) vent cowl 110mm fixed in repairs complete all as specified anddirected. |
| 54 | PVC (SWR) junction single (single T ) equal or un equal withaccess door75 mm fixed in repairs complete all as specified anddirected. |
| 55 | PVC (SWR) junction single (single T ) equal or un equal withaccess door110mm fixed in repairs complete all as specified anddirected. |
| 56 | Dismantling of wall and ceiling boards/Partition (fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover filletscomplete all as specified and directed. |
| 57 | M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing withstaples on snap grid by means of GI wires not less than 4mmdia hooks and raw plug etc centre of make GYPTECH/ARMSTRONG or equivalent complete all as specified and as directed. |
| 58 | M&Lfor providing and fixing Gypsum board 12mm thick in ceiling fixed with screw to existing frame work, applying plaster of Paris putty of 2mm thickness and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer of required shade and colour complete as per manufacturer\"s specification (Two Coat) complete all as specified and directed. |
| 59 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as specified and directed. |
| 60 | S&F5mm thickPVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. Inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawingcomplete all as specified and as directed. |
| 61 | Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exc.1.5 sqm each including separating guard bars/ grills/ wire mesh etc., all as specified and as directed. |
| 62 | Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc.1.5 sqm but not exc 4sqm each including separating guard bars/grills/wire mesh etc., complete all as specified and as directed. |
| 63 | Taking down shutters of any description exc. 1sqm but not exceeding 2sqmeach including builders hardware complete all as specified and directed. |
| 64 | Taking down shutters of any description exc. 1sqm but not exc. 2 sqm and refixing in the same opening after cutting, easining etc with new iron mongry complete all as specified and as directed |
| 65 | M&L for Second class Hard wood, plain solid straight chowkats and frames rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fitted complete all as specified and as directed. |
| 66 | S & F small articles of steel such as hold fast, etc of Gde Fe 410-0 or Fe-290 Gde E-165 complete all as specified and directed. |
| 67 | M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in hold fast etc., complete all as specified and directed. |
| 68 | M & L for preparing and treating ends of posts, back of chowkats with coal tar black paint, area tarred exc. 0.10 sqm but not exc. 0.50 sqm complete all as specified and directed. |
| 69 | M & L for preparing and treating small articles such as hold fastswith coal tar black paint, area tarred not exc. 0.10 sqmcomplete all as specified and directed. |
| 70 | M&L for35mm thick second class hard wood Glazed and skeleton door shutters open rebated and prepared to receive glass, gauze, etc. withsash bars edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 71 | M&L for30mm thick second class hard wood Glazed and skeleton window shutters open rebated and prepared to receive glass, gauze, etc. withsash bars edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed. |
| 72 | M& L for 30 mm thick flush door shutter, solid core construction , with block board core and plywood face panels, commercial type on both side etc. complete all as specified and directed. |
| 73 | S&F Plain framed, panelled shutter 35mm thick (two panel) with lock rail & panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. 2nd Class HW rail & style of size as per IS: 1003 (Part I), kiln seasoned & chemically pressure treated complete all as specified and directed. |
| 74 | S&F in repair Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metredcut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall in repairs by drilling 100mm long MS screws using PVC fastener complete all as specified and directed. |
| 75 | S&F in repair Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing complete all as specified and directed.Note: PVC door shutters shall be provided with 02 No. of 125mm size aluminium anodised handle, 03 No. of 100mm mild steel hinges and 02 No. of 150mm size aluminium anodised tower bolt of extruded section per shutter. The unit quoted rates shall be deemed to include the cost of builder’s hardware provided. |
| 76 | S&F Butt hinges, 100mmsize medium weightcold rolled mild steel Etc., complete all as specified and directed. |
| 77 | S&F Aluminiumhandlescast typeanodised 150 mm size complete all as specified and directed. |
| 78 | S& F Aluminium alloy, anodised sliding door bolts 300mm long with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified and directed. |
| 79 | S& F 140 mm over all length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed infloor complete all as specified and directed. |
| 80 | S&F Aluminium anodised barrel tower bolts, extruded section of size 200mm long complete all as specified and directed. |
| 81 | S&F Butt hinges, 75mmsize medium weightcold rolled mild steel Etc., complete all as specified and directed. |
| 82 | S&F Aluminium anodisedbarrel tower bolts of extrudedsection 100mm long complete all as specified and directed. |
| 83 | S&F Aluminiumhandlescast typeanodised 100 mm size complete all as specified and directed. |
| 84 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified & directed. |
| 85 | S&F Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wood/steel frames complete all as specified and directed. |
| 86 | M&L for applying two coat of Synthetic enamel paint over a coat of pink primerforwooden surfaces including necessary preparation of new wooden surfaces of any description exc. 10cm width or girth complete all as specified and directed. |
| 87 | S&Fin repair Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wood/steel framesfixed in repairs complete all as specified and directed. |
| 88 | S&F Sheet glass 4.0mm thick, plain ordinary quality in square n exc 0.5 sq.m in each pane including hacking out old broken glass (any thickness, size, quality or description ) from wooden/Aluminium frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads/glazing completeall as specified and directed. |
| 89 | S&F Sheet glass 5.5mm thick, plain ordinary quality in square exc 0.5 sq.m in each pane fixing to aluminium frame work including hacking out old broken glass (any thickness, size, quality or description ) from Aluminium section fixed with beads/glazing clips complete all as specified and directed. |
| 90 | S&F figured glass 4.0mm thick, pin head type& glazing with oil putty in square n exc 0.5 sq.m in each pane from Aluminium section fixed with beads/glazing clips complete all as specified and directed. |
| 91 | S&F in repairs Butt hinges, 75mmsize medium weightcold rolled mild steel Etc., complete all as specified and directed. |
| 92 | S&F in repairs Butt hinges, 100mmsize medium weightcold rolled mild steel Etc., complete all as specified and directed. |
| 93 | S&Fin repairs Aluminium anodisedbarrel tower bolts of extrudedsection 100mm long complete all as specified and directed. |
| 94 | S&F in repairs Aluminium anodised barrel tower bolts, extruded section of size 200mm long complete all as specified and directed. |
| 95 | S&F in repairs Aluminiumhandlescast typeanodised 100 mm size complete all as specified and directed. |
| 96 | S&F in repairs Aluminiumhandlescast typeanodised 150 mm size complete all as specified and directed. |
| 97 | S& F in repairs Aluminium alloy, anodised sliding door bolts 300mm long with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified and directed. |
| 98 | S& F in repairs Mild steel sliding door bolts, 300mm long plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 99 | S & F in repairsmild steel 300 mm , ordinary rat rail rod pattern springs including roller and roller plate incl welding complete all as specified and directed. |
| 100 | S& F in repairs 140 mm over all length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed infloor complete all as specified and directed. |
| 101 | S&F aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for doors/ windows /ventilator/ partition, glassing clips with one or more tracks including joining cleats for fixing complete all as specified and directed. |
| 102 | S&F for powder coatedaluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed. |
| 103 | S&F in repairs aluminium powder coated sliding window (for width 1.00 above and openable for below 1.50 M width)using aluminium section weighing not less than 0.495 Kg per RM for frame and 0.48 Kg per RM for sliding shutters includingaluminium anodised snap beads, screws andfixed alongwith same sectionin three rolling sliding shutters two for fully glazed with 5mm thick tinted glass fixed with glazing clips, and one for wire mesh shutters) etc(The rate is inclusive of all fixings of builders hard ware such as wiremesh hinges, bow handles, locking arrangements etc complete all as specified and directed. |
| 104 | M & L in repairs stainless steel curtain rods with designer bracket and fixed with L clamps and fixed to wall PVC rowel plug and brass screws complete all as specified and directed. |
| 105 | M & L for12mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to aluminium frame work shutter etc.,complete all as specified and directed. |
| 106 | S&F for 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.50 Sqm in each pane completeall as specified and as directed |
| 107 | S&F in repair for Harrison Curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.in repair complete all as specified and directed. |
| 108 | S & F in repairs Cast Aluminium (Die cast ) body door closer hydraulically regulated, designation No.2 universal type, suitable for door shutters up to 701mm to 850 mmin width and of weightbetween 36 to 60 kg complete all as specified and directed. |
| 109 | M& Lin repairs Brass mortice lock vertical typesize 100 mm4 leaverswith stain less steelhandleset suitable for right or left, inside or out side opening doors complete all as specified and directed. |
| 110 | Supply and fix Fully Glazed door shutters made out of 12mm thick toughened glass suitable for opening not exc. 1.20m wide as approved by GE, drilling holes for fixing handles including provision of Stainless Steel matt finish handle 400mm-2Nos, suitable locking arrangements, centre lock, Stainless steel body floor spring, patch fitting consists of Bottom patch, top patch and top pivot with Stainless steel fixing plate etc., complete incl taking down old unserviceable glass door complete all as specified and directed.Note : The unit rate quoted shall be deemed to include all necessary builders hardware except door closer. |
| 111 | S&F of Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed including removing of old floor spring complete all as specified and directed. |
| 112 | Supply and Fix in repairs Floor locking arrangements with brass lock and complete accessories suitable for 12mm thick toughened glass door with complete accessories of make Dorma or Pag or any reputed make as approved complete all as specified and directed. |
| 113 | Supply and fix Door closers, heavy duty with pivot and connected accessories, Satin stainless steel finish,sustainable for long duration suitable for 12mm thick toughened glass shutters all as per BTS 80 series ofDorma or equivalent of PAG or any reputed make as approvedincluding taking down old unserviceable door closure complete all as specified and directed. |
| 114 | Dismantling floor, hearth or wall tiling including cement mortar of existing backing coat and screed removing serviceable tile to store and rubbish off the premises complete all as specified and directed. |
| 115 | M&L for Vitrified Ceramic light coloured tiles in Patches of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour and pattern of the tile as approved over and including 15 mm thick screed bed in Cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 116 | M&L for Vitrified Ceramiclight coloured tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour and pattern of the tile as approved over and including backing coat in Cement Mortar 1:3, 10mm thick on fair faces of brick or concrete surfaces complete all as specified and directed. |
| 117 | M & L for non skid ceramic coloured joint free tile in Patches 7 to 8 mm thick Concept tiles design as approved (Square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqmin floors etc of pattern as approved over and including 15 mm thick screed bed in Cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 118 | M&L for glazed coloured ceramic Concept designer tiles of7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE,fixed in vertical surfaces in Patches such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick complete all as specified and directed. |
| 119 | Demolition of cement concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing unserviceable material outside cantt area, complete all as specified and directed. |
| 120 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for) and removing unserviceable material outside cantt area, complete all as specified and directed. |
| 121 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishingsurface even and smooth without using extra cement complete all as specified and directed.(Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and every turning/ corners.) |
| 122 | M&L PCC 1:4:8, Type D2 (using 20 mm graded stone aggregate), 75 mm thick, as in sub base complete all as specified and directed. |
| 123 | M & L for PCC 1:2:4 type B1( 20 mm graded aggregate )as in hard standing /pathsetc complete 40 mm thick finished even & smooth without using extra cement complete all as specified and directed. |
| 124 | M&L Machine pressed precast concrete interlocking paver block 60mmwith Grey cement and pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Gradeacomplete all as specified and directed. |
| 125 | S&F for Chequered cement concrete tiles 30cm x 30cm x 20-25mm thick, set, jointed and pointed in neat cement slurry in floorsPattern, size and shade pointed with grey cement and pigmentcomplete all as specified and directed. |
| 126 | M/L sand filling under paver blocks including watering and consolidation complete all as specified and directed. |
| 127 | M/L Screed bedor bedding layer of mortar 15mm thk for laying floor finish in CM 1:6 complete all as specified and directed. |
| 128 | M&L for Precast cover slab 1:2:4, type B1 (using 20mm graded aggregate) inlandings, cover slabs (for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 set in CM 1:4, for manholes etc., including demolition of existing cover slab complete all as specified and directed. |
| 129 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete all as specified and directed. |
| 130 | Demolition of Stone slabs and tiles of laid bedded and pointed in cement mortar or in any description or thickness in floors, platforms, aprons etc. complete all as specified and directed. |
| 131 | M&L 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 15 mm thick backing coat cement mortar (1 : 4) including pointing ,moulding the edges in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 132 | Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all as specified and directed. |
| 133 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 134 | M & L for Brickwork with fly ash bricks , straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 135 | M & L for 15mm thick rendering on brick masonry or concrete surface, in CM 1:4 including finished the surface smooth and even W/o using extra cement complete all as specified and directed. |
| 136 | M/L preparation of newly plastered wallsurfaces and applying two coats of cement based paint incl primer complete all as specified and as directed |
| 137 | M & L cement concrete type B-1 1:2:4 using 20mm graded aggregate in lintels up to 1.5m clear span, cills , steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60cm in height, copings, kneelers apex stones, bed plates, kerbs not provided for in height, coping not provided for in item 04028, water troughs and the like incl weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 138 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 139 | Framed work such as grills, grating, etc with ends of bars shouldered and or riveted or forged into spikes, framed grating or similar work confirming to Fe 410-0 complete all as specified and directed. |
| 140 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc.,of grade Fe 410-W (Gde-E- 250) quality-A- complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 141 | S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\")all as specified and as directed |
| 142 | S&F for Rolled sections mild steel Fe 410-W (Gde-E- 250) quality-A-as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 143 | M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and directed. |
| 144 | Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed. |
| 145 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & ramming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface soft/loose soil complete all as specified and directed. |
| 146 | M&L for cement concrete1:4:8, type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 147 | Dismantling of PGI/CGI/Galvalume sheets asin roof coverings complete all as specified and directed. |
| 148 | S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 149 | S&F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 150 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cant area, complete all as specified and directed. |
| 151 | M&L forpreparation of existing surfacesof walls/chajjas/facia etc in patches to remove all dirt, mildew and other contaminants. Treating areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width shall be filled up with Dr. Fixit Crack-X.Cracks or its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. Separation gaps more than 5 mm should be filled up with Dr. Fixit Pidicrete URP modified mortaror its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP. Priming shall be done using Dr. Fixit Prime sealor its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2parts Prime seal diluted with 1 part water) @ rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. It shall be allowedto dry for 6-8 hrs. One coat ofDr. Fixit Raincoat Waterproof Coatingor its techno commercial equivalent in BASF/FORSOC/CICO/MC-BAUCHMIE/STP shall be coated without dilution by brush or roller for rain lashing walls at the thickness of 120 – 130 microns all as specified and directed .Note: All above treatment shall be measured as one unit of square metre and paid accordingly. |
| 152 | Gl wire netting 0.90mm dia & 12mm mesh in patches of lathing to wood or metal studding, joists, etc. in walls. Ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified and directed. |
| 153 | 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces in patches finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 154 | M&L for rendering 5 mm thick using CM (1:3) on ceiling surfaces in patches finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 155 | 15 mm thick renderingon fair faces of brick work or concrete surfaces of walls in patches etc 10 mm thick in CM 1:6 and 5 mm thick inCM 1:4incl water proofing compound as per manufacturers instruction & finished the surfaces even and smooth without using extra cement, complete all as specified and directed. Note : WPC WILL BE MEASURED AND PAID SEPERATELY |
| 156 | Supply only Liquid water proofing compound (Make SIKA/FOSROC/CHOKSEY) complete all as specified and directed. |
| 157 | Preparation of new plasters surfaces of wall and applying plaster of Paris putty of 1 mm thickness over newly plastered surface to prepare the surface even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification and asdirected. |
| 158 | Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 159 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge. Make: APEX ofAsian or equivalent of Shalimar / Nerolac/ Berger. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail