| 1 | 9 METER WIDE ROADS |
| 2 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 3 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m. Transporting to site,spreading,grading to required slope and compacting to meet requirement of tables 300.1 and 300.2 with a lead upto 3000 mas per technical specification clause 301.5 (Including Costing Of Earth) |
| 4 | Construction of granular sub-base by providing close gradedMaterial,mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 |
| 5 | Providing laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub - base / base course on well prepared surface and compacting with vibratory roller to achive the desired density |
| 6 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom |
| 7 | Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H specification clause No. 505 complete in all respects. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. 1 : 3 : 6 ( 1 Cement : 3 Coarse Sand (zone-III) : 6 graded stone aggregate 20mm) |
| 9 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50 mmthick compacted bed of sand, compacting and proper embedding/layingof inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 10 | Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. |
| 11 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. |
| 12 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 13 | 12 METER WIDE ROADS |
| 14 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 15 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m. Transporting to site,spreading,grading to required slope and compacting to meet requirement of tables 300.1 and 300.2 with a lead upto 3000 mas per technical specification clause 301.5 (Including Costing Of Earth) |
| 16 | Construction of granular sub-base by providing close gradedMaterial,mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 |
| 17 | Providing laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub - base / base course on well prepared surface and compacting with vibratory roller to achive the desired density |
| 18 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom |
| 19 | Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRT&H specification clause No. 505 complete in all respects. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. 1 : 3 : 6 ( 1 Cement : 3 Coarse Sand (zone-III) : 6 graded stone aggregate 20mm) |
| 21 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 22 | Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete. |
| 23 | HUME PIPES |
| 24 | Excavation for depth upto 1.5m below ground level for laying sewers, manholes, gully pits,chambers,sumps etc. in ordinary soil (earth sand,loam and clay) including dressing,leveling,refilling of trenches in 20 cm. layers watering sand ramming the same including removal of surplus earth of other dismantled materials upto a distance of 50m. from the centre of trences. |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.1:5:10 (1 Cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) 450 mm. dia. |
| 26 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe |
| 27 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of NP-2 pipes including bed concrete as per standard design : 450 mm diameter NP-2 pipe (Both Sides) |
| 28 | SEWERAGE SYSTEM (9 Meter Road) |
| 29 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 300 mm to 600 mmdiameter |
| 30 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m to 3.00 m depthPipes 300 mm to 600 mmdiameter |
| 31 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 32 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth 1.5 to3.00meter |
| 33 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.150 mm. dia. DWC (SN8) Pipes |
| 34 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.250 mm. dia. DWC (SN8) Pipes |
| 35 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.300 mm. dia. DWC (SN8) Pipes |
| 36 | Providing and laying in Position cement concrete of specified grade ecluding the cost of centering and shuttering- All Work up to plinth level : 1:5:10 (1 Cement :5 Coarse sand (zone-iii) derived from natural sources :10 graded stone aggregate 40mm nominal size derived from natural sources) |
| 37 | Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks |
| 38 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75 (i) For Sewer Line |
| 39 | Extra for depth for manholes : Size 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 40 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 41 | Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 42 | Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 43 | SEWERAGE SYSTEM (12 Meter Road) |
| 44 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depthPipes 300 mm to 600 mmdiameter |
| 45 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m to 3.00 m depthPipes 300 mm to 600 mmdiameterPipes 300 mm to 600 mmdiameter |
| 46 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 47 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth 1.5 to3.00meter |
| 48 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.150 mm. dia. DWC (SN8) Pipes |
| 49 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.250 mm. dia. DWC (SN8) Pipes |
| 50 | Providing and layingDWC (SN8)pipes conforms the IS 16098 (Part 2): 3013 Structured-Wall plastics piping systems for NON- Pressure drainage and sewerage –Specificationincluding jointing with seal ring conforming.300 mm. dia. DWC (SN8) Pipes |
| 51 | Providing and laying in Position cement concrete of specified grade ecluding the cost of centering and shuttering- All Work up to plinth level : 1:5:10 (1 Cement :5 Coarse sand (zone-iii) derived from natural sources :10 graded stone aggregate 40mm nominal size derived from natural sources) |
| 52 | Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks |
| 53 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75 (i) For Sewer Line |
| 54 | Extra for depth for manholes :Size 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 55 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 56 | Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |